Sub Work. Installation Of 50 Kw Genset In The Department Of Food And Drugs Testing Laboratory, Goriemedu, Puducherry. Sub Work. Installation Of 50 Kw Genset In The Department Of Food And Drugs Testing Laboratory, Goriemedu, Puducherry., Puducherry-Puducherry

Public Works Department-PWD has published Sub Work. Installation Of 50 Kw Genset In The Department Of Food And Drugs Testing Laboratory, Goriemedu, Puducherry. Sub Work. Installation Of 50 Kw Genset In The Department Of Food And Drugs Testing Laboratory, Goriemedu, Puducherry.. Submission Date for this Tender is 05-08-2021. Diesel Generators Tenders in Puducherry Puducherry. Bidders can get complete Tender details and download the document.




Tender Notice

28695758
Sub Work. Installation Of 50 Kw Genset In The Department Of Food And Drugs Testing Laboratory, Goriemedu, Puducherry. Sub Work. Installation Of 50 Kw Genset In The Department Of Food And Drugs Testing Laboratory, Goriemedu, Puducherry.
Open Tender
Indian
Puducherry
Puducherry
05-08-2021

Tender Details

Sub Work. Installation Of 50 Kw Genset In The Department Of Food And Drugs Testing Laboratory, Goriemedu, Puducherry. Sub Work. Installation Of 50 Kw Genset In The Department Of Food And Drugs Testing Laboratory, Goriemedu, Puducherry.

Key Value

Document Fees
INR 525 /-
EMD
Refer document
Tender Value
INR 7.06 Lakhs /-

BOQ Items

Name of Work: Construction of RCC Generator shed/Gas cylinders storage and up-gradation and renovation to the existing Laboratory for accommodating sophisticated instruments for the Departmentof Food and Drugs Testing, Puducherry. Sub-Work:Installation of 50 KW Genset in the Department of Food and Drugs testing Laboratory, Goriemedu, Puducherry.
Sl. No. Item Description
1Supplying of 3.5x95 sqmm underground cable (Paragon/suncab/Empire) complete.- suitable for (60HP to 75HP pumpset)/(above 40KVA to 75KVA Genset).
2Laying of UG cable and providing termination of cable joint with suitable cable gland,cable socket etc., complete - 3.5 x 95 sqmm cable
3Making earth pit of G.I. pipe for earthing in earth pit with 40mm dia. G.I. pipe medium class of length 3.05m perforated with 46 Nos of 12mm dia. holes, pipe lowered in bore holes of 150mm dia. and filled in with charcoal and salt in alternative layer of 300mm, the top of G.I. pipe shall be clamped. Earth pit shall be provided with 60cm dia precast ring with 60cm depth alround,covered with R.C.C. precast slab etc. as per I.E. standards.
4Supplying and fixing of copper flat (25 x 3mm) for earthing arrangements including bolts and nuts etc.
5Supplying of 3 phase, 415 volts, 50 cycles, 0.8 power factor for electric starting diesel generator comprising the following units:- (Kirloskar/Leyland/Ruston/Greaves Cotton / Cummins make) air cooled and shall be of multi stroke, multi cylinders, cold starting, developing not less than 83 BHP under normal temperature and pressure. The engine shall conform to I.S. 10002 with latest amendments. It shall be capable of taking 10% over load for one hour in every 12 hours of continous operation including 6 Nos. of anti vibration pads.The engine shall be complete with the following accessories:Electrical starting provision, engine cooling fan, fuel and lubricating oil filters, oil bath, air filter, lub oil pressure gauge140 litres capacity fuel tank mounted with engine, hour meter with exhaust manifold, flexible pipe, 12 /24 volts electric starting equipment complete with starter, alternator and one 12 volts with 21 plates battery of make AMCO/STANDARD/EXIDE/DAGANITE (with Guarantee cards) of adequate capacity and low lubricating oil pressure/high temperature varying engine shut down devices.The Acoustic enclosure shall have the following: Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Powder coating is done after seven tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam/Rock Wool as acoustic material. Four hinged doors shall be provided to canopy, one door shall have glass window for control panel.Base frame is fabricated either in ISMC channel or in sheet metal. The base frame is rugged in construction and designed for mounting engine and alternator, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure and it is having provision of lifting hook for convenient lifting of complete set, i.e. along with canopy, engine and alternator.Fuel tank shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet and outlet connections of suitable capacity.The Acoustic enclosure shall be Type test approved as per CPCB norms. The average sound level, when measure in green field condition (ISO m3744 OR 8528 PT 10) at 1-meter distance from all four sides shall be less than 75-dBA average or as per CPCB norms. The average stabilized hot air temperature rise with in the canopy is maintained with in 10 C over and above ambient temperature.Acoustic enclosure is suitable for Outdoor / Indoor installation. Lockable doors shall be provided. Lockable fuel filling arrangement to be provided external to the canopy. Residential Silencer is housed in the canopy. The exhaust gasses shall be taken out through a suitable flexible pipe to prevent any back pressure on the engine.Base frame sturdy, fabricated welded construction, channel iron / sheet metal base frame for mounting the above engine and alternator.Standard Tools and Spares:Double ended spanners complete set (small and big size sets) - 12 Nos. (TAPARIA/GEDORGE/EVEREST make) Screw driver (30cm long) Taparia make Screw driver (45cm long) Taparia make. Cutting plyer. Diesel filter with elements - 2 Nos. Oil filter with elements - 1 No.All the above accessories with complete set. AlternatorThe alternator shall be of Crompton/Kirloskar/ Stamford/ELGI make, self excited, self regulated, screen protected, drip proof alternator with static excitation system capable of developing 62.5 KVA at 0.8 power factor 415 volts, 3 phase, 50 cycles, generally conforming to I.S.4722 under normal condition, the voltage regulation will be plus or minus 5% of rated voltage. It shall be with end shield/ball roller bearings complete. Control PanelA wall/pedestal mounting (cubical type) fabricated sheet steel construction suitable for manual operation, rated for system output incorporating the following devices/instruments. The panel is made of 1.6mm sheet with one/two hinged front door, bolted back totally enclosed and vermine proof. It shall be with all electrical connections and internal copper wiring with proper color codings for internal wiring. All control equipments and indicating instruments shall be mounted on the control panel. The control panel shall have the following equipments:1 No. Amps/Volt/Frequency meter (96mm x 96 mm) 3 Nos. of suitable current transformers2 Nos. of suitable selector switches for voltmeter and ammeter main switch rotary type on/off pilot lamp (Standard make).1 No. input terminal board.1 No. out put terminal board1 No. Kilowatt hour meter (62.5 KVA and above)1 No. MCCB of suitable capacity (L&T/CROMPTON make)-62.5 KVA / 50 KW Generator set (Air cooled).
6Providing and fixing of suitable M.S.exhaust pipe including 2 Nos. of M.S. bends (long), 7 Nos. of M.S. flanges, M.S. pipe Class B - 5 Rm as flexible exhaust pipe. The rate is inclusive of transportation charges for shifting of welding machine and gas cutting set to site, consumption of welding rod 10 SWG and cutting gas, providing fasterners of 10mm bolts / nuts / washers and flange gaskets including labour charges etc. as per IE standard.-80 mm dia exhaust pipe (From 50 KVA to 100 KVA).
7Providing and laying of aluminium cladding with 50 mm thick glass wool slab with chicken mesh and covered with 24 SWG aluminium sheet (the rate includes double calculation for flanges & bends) as per I.E. standards.
8Providing and fixing of fire safety equipments comprising 1 No. of 4.5 kg of CO2 fire extinquisher 1m x 2m x6mm thick rubber mat shock proof of superior quality with two numbers of 10 litres capacity fire buckets (red colour) with M.S. stand arrangements etc.
9Providing and fixing of 4 pole change over switch of STANDARD/HAVELLS/KUNDAN/ GEM make including M.S. frame as per I.E. standard.-200 Amps(from 62.5/63 KVA to 100 KVA).
10Charges for transporting, erection, testing and commissioning of generator set excluding foundation,but including mechanical and other unskilled wages for installation of equipment, wiring from generator set to panel board and change over switches, handling charges, purchase of spares if any required for the installation and commissioning, the cost of fuel and other materials for a trial run of 6 hours. This rate also includes for testing and commissioning of generator set as specified, obtaining approval of Central Electricity Authority (CEA), payment for CEA inspection/Licence fees or any other charges and fulfilling other requirements and conditions laid down by CEA-From 62.5 / 63 KVA to 100 KVA.