Repairs And Maintenance Of Ceiling Fan, Exhaust Fan, Air Circulator And Internal Wiring At Hl Baroda As Per Boq, GE Army Baroda-Gujarat

Military Engineer Services-MES has published Repairs And Maintenance Of Ceiling Fan, Exhaust Fan, Air Circulator And Internal Wiring At Hl Baroda As Per Boq. Submission Date for this Tender is 17-08-2021. Electrification Work Tenders in GE Army Baroda Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

28676965
Corrigendum : Repairs And Maintenance Of Ceiling Fan, Exhaust Fan, Air Circulator And Internal Wiring At Hl Baroda As Per Boq
Open Tender
Indian
Gujarat
GE Army Baroda
17-08-2021

Tender Details

Repairs And Maintenance Of Ceiling Fan, Exhaust Fan, Air Circulator And Internal Wiring At Hl Baroda As Per Boq

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:REPAIRS AND MAINTENANCE OF CEILING FAN, EXHAUST FAN, AIR CIRCULATOR AND INTERNAL WIRING AT HL BARODA
Sl. No. Item Description
1S&F in replacement Switch piano flush type single pole, one way 5/6 Amp complete.
2S&F in replacement switch piano flush type single pole, two way 6amp complete.
3S&F in replacement switch piano flush type single pole, one way 15/16 Amp complete.
4S&F in replacement socket flush type 2 in 1,3 pin, 5 and15/16 Amp complete.
5S&F in replacement socketflush type 2 in 1,3 pin, 5 Amp complete.
6S&F in replacement switch socket combination 5 pin 6 amp complete.
7S&F in replacement Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete.
8S&F in replacementelectronic type fan rgulator,not less than 100 watt single phase 230Vcomplete.
9S&Fflush type bell push 6 amp duly marked for bell complete.
10S&F Electronic ding dong bellAC 230V single pole .
11S&F in replacement lamp holder, PVC / Polycarbonate type and back plate suitable for batten fitting complete.
12S&F in replacement capacitor electronic type suitable for ceiling fancomplete of 2.5 MFD capacity complete..
13S&F in replacement electronic ballast for FTL of capacity 36/40 W, 230 volt of Make Wipro or equivalent in other specified makes complete
14S&F in repair tube light 36W/40W tubular fluorescent lamp, Lumens 2425, 5 BEE star rating complete.
15S&F in replacementElectronic ballast 18/20 watt complete.
16S&F in replacementtube light 18W/20W tubular fluorescent lamp complete.
17S&F in replacementElectronic ballast 28 watt complete.
18S&F in replacementtube light 28W tubular fluorescent lamp complete.
19S&F in replacement 9W LED Bulb suitable for B22 holder complete.
20S&F in replacement 7W LED Bulb suitable for B22 holder complete.
21S&F in replacement 5W LED Bulb suitable for B22 holder complete.
22S&F in replacement 1x 4" feet 1X18 LED tube rod in lieu of existing 36/40watt tube rod, electronic ballast 230V 50 Hz,conforms to applicable IS 10322/EN 60598 and similar to Havells model No : CRYSTAL 1213T8DSTL18WLED865SGLASS complete.
23S&F in repair main terminal boxes made out of GI sheet, not less than 1.2 mm thick of existing size suitable for 8" x 12"bakelite sheet housingof fittings, switches, sockets outlets,regulators etc and making good to disturbed surface of wall to match with existing complete
24S&F in repair GI terminal boxes made out of GI sheet, not less than 1.2 mm thick of existing size suitable for 7" x 5" bakelite sheet mountinghousingof at least one switch sockets outlets 15 Amps etc and making good to disturbed surface of wall to match with existing complete
25S&F in repair GI terminal boxes made out of GI sheet, not less than 1.2 mm thick ofexistingsize suitable for 5"x 5" bakelite sheet mountinghousingof at least one switch sockets outlets 5 Amps etc and making good to disturbed surface of wall to match with existing complete
26S&F in repairbakelite laminated sheat top cover 3mm thick of 8" X 12" size for mounting of fittings, switches, sockets outlets, regulators etc including refixing seviceable switches, switch sockets and regulators etc complete
27S&F in repair bakelite laminated sheattop cover 3mm thick of7" X 4"sizeformounting of switch sockets outlets 15 amp, etc complete including refixing seviceable switch sockets etc complete
28S&F in repair bakelite laminated sheat top cover 3mm thick of5" X 4" size for mounting of switch sockets outlets 5 Amp etc complete including refixing seviceableswitch socketsetc complete
29Supply only1.5 sqmm PVC insulated overall PVC sheathed 3 core flexible cable for maintenance of tube lights and fans.
30Dismantling damaged wooden boards of Electric meter by disconnecting all electric connection and S&F rectangular teak wood board of size 30cm x 25cm x 5cm deep with smooth hylem sheet top 5mm thick for mounting Electric Meter including making holes for incomming and outgoing wires and making necessary electrical connections complete.
31Taking down existing UNSV copper/aluminium point wiring (light, fan, socket or power) and M&Lforconcealed point wiring with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLS cable 1100 volts grade, conforming IS 694 & color code in conduit system of wiring, drawn in & including medium grade PVC conduit not less than 20 mm dia concealed, including cutting chases,sunk in pressed steel terminal boxes of required size not less than 1.6mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet & fixed with brass screw and washer with all accessories including single core solid conductor copper 1.5 sqmm size solid PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit and making good disturbed surfaces of walls, floors, etc to match with existing by means of finising of slote with cement mortor & touching with the existing colour of wall with three coats complete for One light point controlled by one switch 6 Amp one way complete .
32All as per above Item no 31 but for One fan point controlled by one switch 6 Amp one way complete.
33All as per above Item no 31 but for One bell point controlled by one switch 6 Amp one way complete.
34All as per above Item no 31 but for One 3 pin switch socket combination 6 amp on the independent board complete.
35All as per above Item no 31 but for One 3 pin switch socket combination on same board with other switches complete.
36All as per above Item no 31 but for One light point controlled by two way switches
37All as described as per item No 31 above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathedFRLS cable 1100 volt grade and 2.5 sqmm PVC insulated and unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
38S&F in repair TPN DBs4 way with provision for FP as incomer and SP as outgoing IP 43-IK 09 with metal double door complete
39S&F in replacement Distribution board SPN 12 way Double door including fixing and connectingof mounting MCBs isolator, ELCBs etc factory made, confirming to IS:13032 fabricated out of CRCA sheet. The DBs shall be of same make as MCBs /Isolator. DB shall also be provided with lable marking indicating the incoming and outgoing circuits on all way complete.
40All as per described in Item no 33 above but for SPN 8 way
41All as per described in Item no 33 above but for SPN 4 way
42S&F in replacement MCB"s TPN 63 Amps 10 KA rupturing capacityconforming to IS-8828
43All as per described in Item no 34 above but for MCB SPN 5 to 40 Amps.
44All as per described in Item no 34 above but for MCB SP 5 to 40 Amps
45M&L in repairs Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor complete. NOTE : Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
46M&L in repairs Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor complete. NOTE : Two runs of single core 4.0 sqmm and one run of 4.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
47Supply, Fixing, Testing and commissioning of 4" LED fitting not less than 1X18W LED Batten with LED tube rod not less than 18 watt. Similar to Batten cat Part No.REGALBATTEN8UPTO1X22wSSBSWH and LED tube light cat part No.CRYSTAL1213T8DSTL18WLED865SGLASS of Make- Havells or equivalent in Make: Philips/Wipro/CG/Bajaj
48Supply, Fixing, Testing & Commsioning in replacement ofIP65 integral LED Bulk Head luminaire. Power Consumption should not exceed 10W (Including Driver Loss) and Similar to cat Part No. RUGBYNEONFT10WLED760SSYMBOPC of Havells complete.
49Supply, Fixing, Testing & Commisioning in repairs of 2" not less than 10W Mirror LED Battenmounting on two PVC square boxes of size not less than 75mm X 75mm and connecting fitting with not less tha 0.5 sqmm 3 core flexible stranded copper conductor wire upto ceiling rose and similar to Havells, Model-ENDURALINEARNEOBS10W LED 830SPCWH complete.
50S&F in replacement wall security light LED type not less than 25W and connecting with not less tha 0.5 sqmm 3 core flexible stranded copper conductor wire upto ceiling rose and similar toHavells, Model-ENDURAPEARLSL25WLED757SASYTOPC complete
51M&L in replacement of 25 mm bore light grade GI pipe fixed as bracket, on wall any type, not less than 1.0 m long and bent to shape as required complete with sutiable clamp made out of 25 x 4mm Flat iron dulyfixed 12mm dia nuts, bolts, washers etc. suitable for steel tubular / PCC pole complete.
52Supply, laying or fixing or passing through pipe in replacement XLPE insulated armoured heavy duty electric cable withaluminium conducto1100 volts grade cross sectional area16 sq. mm 4 Core complete.
53Supply, laying or fixing or passing through pipe in replacement XLPE insulated armoured heavy duty electric cable withaluminium conducto1100 volts grade cross sectional area25 sq. mm 3.5 Core complete.
54Supply, installaing, connecting and testing in replacement electronic single phase AC energy (kWh) meter of accuracy class 1.0, Rating 10-60Ams, 240 volt, 50Hz, tamper proof type, 2 wire, with LCD Display, conforming IP54, including pilfer proof meter box with sealing screw provision and electric connection with existing cable and duly sealed similar to as per model No SPPB15100000020C00 of HPL complete. Note :Old unserviceable meter shall be deposited to AGE E/M store yard through RV.
55M&L for opening covers of ceiling fan, remove the burnt winding, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bearings No 6201/6202 for 1200mm sweep, greasing, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan, replace of fan capacitor 2.5mfd and making connection with fan capacitor and connector block, transoporting back after repair, assembling the blades, painting and hanging the fan in its own position to existing fan clamp and down rod with necessary Nut, bolt and washer and testing for smooth functioning after finishing repair complete. Note :Quoted rate deems to inclusive of labour charges and items/jobs of fan rewinding, capacitor, fan bearing, servicing, painting, wire and transporatation charges.
56M&L for opening covers of Exhaust fan 225/250/300mm, remove the burnt winding, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bush/bearings, greasing, replace of armature coil with shaft, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan and making connections, transoporting back after repair, assembling the blades, painting and fixing the fan in its own position with existing clamp with necessary Nut, bolt and washer and testing for smooth functioning after finishing repair complete. Note :1.Quoted rate deems to inclusive of labour charges and items/jobs of fan rewinding, fan bearing, servicing, painting, wire and transporatation charges.
57M&L for opening covers of Air circulator of any size remove the burnt winding, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bush/bearings, greasing, replace of armature coil with complete shaft, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan and making connections, transoporting back after repair, assembling the blades, painting and fixing the fan in its own position with existing clamp with necessary Nut, bolt and washer and testing for smooth functioning after finishing repair complete. Note :1.Quoted rate deems to inclusive of labour charges and items/jobs of fan rewinding, fan bearing, servicing, painting,wire and transporatation charges.
58Supply, fixing, testing & commissioning of exhaust fan 300 mm sweepwith minimum airflow/air delivery 1710 Cmh, totally enclosed heavy duty motor, die cast aluminium rotor mounted on double ball bearing, IP-55,polarity-4,230 Volt AC supply (single phase), rated power input not more that 90watt, with louvers and connecting up including provison of PVC insulated overall PVC sheathed copper conductor cable from ceiling rose to fan and Similar to Crompton Greaves model No Transair 12" - Reversible complete. Note: Old UNSV ceiling fans will be deposited to AGE E/M office through RV.
59Supply, fixing and testing ceiling fan of 1200mm sweep, 230 Volts, single phase, 50 Hz 3 blades, double ball bearing, 5 star BEE rating connection up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 sqmm from ceiling rose / connector, including extra GI / MS pipe down rode, as per site requirement (approximate length 01 Mtr) complete.
60S&F in replacement Sheet Metal Enclosure with socket plug top and MCBs double pole and neutral enclosure with a two pin and earth plug and socket with one single pole 20 Amps MCB 240V complete
61S&F in replacement PVC casing and casingwith accessories fixed on surface on walls/ceiling by means of PVC sleeves, Dash fastners and cadmium plated screws including putting in existing copper/aluminium cables complete
62S&F in replacement 1x 4" feet 1X22 LED Decorative ultra slim aluminium square profile LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack in lieu of existing 36/40watt tube rod, electronic ballast 230V 50 Hz and conforms to applicable IS 10322/EN 60598 and similar to Havells model No : LHEXBTP7IN1S022 complete.