| 1 | Surface excavation in hard / dense soil n.exc 30cm deep and averaging 15cm deep and getting out all as specified and directed by Engr-in-Charge. |
| 2 | Removing excavated materials to a distance exc 1.5km but not exc 5.0km and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed by Engr-in-Charge. |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; forfoundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed by Engr-In-Charge. |
| 4 | M&L for Cement concrete Type D2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L for precast cement concrete block masonry with solid block, Type C1 1:3:6 (using 20mm graded crushed stonevaggregate) exc 10 cm in width and setting in cement mortar 1:6 extra, complete all as specified and directed by Engineer-in-Charge. |
| 6 | M&L in RCC (nominal mix) Type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 7 | M&L in RCC (nominal mix) Type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge. |
| 8 | M&L in RCC (nominal mix) Type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge. |
| 9 | M&L in RCC (nominal mix) Type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings,balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge. |
| 10 | M&L for flat rough finished surfaces of concrete Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engineer-in-Charge. |
| 11 | M&L for flat rough finished surfaces of concrete Formwork to sides of pillars, posts, struts, piers, columns and stanchions; square or rectangular complete all as specified and directed by Engineer-in-Charge. |
| 12 | M&L for flat rough finished surfaces of comcrete Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams complete all as specified and directed by Engineer-in-Charge. |
| 13 | M&L for flat rough finished surfaces of concrete Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge. |
| 14 | M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, binding spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) n. less than 0.9mm dia complete all as specified and directed by Engr-in-Charge. |
| 15 | All as per BOQ Srl item No. 14.00 above but 6 mm to 8mm dia, quality conforming to complete all as specified and directed. |
| 16 | All as per BOQ Srl item No. 14.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for Internal rendering 15 mm thick in cm 1:6 on fair faces of block masonry /brick work surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L for External rendering 20 mm thick in cm 1:4 on fair faces of block masonry /brick work surfaces finished even and smooth without using extra cement, complete all as specified and directed. |
| 19 | M&L for 2nd class hardwood exc 13 Sqcm but n.exc. 25 Sqcm plain fillets square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L for 2nd class hardwood of size 50mm x 75mm in scantlings clean sawn, secured with nails or brads complete all as specified and directed by Engr-in-Charge. |
| 21 | S&F 4mm Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with nails to timber frame work in walls complete all as specified and directed by Engr-in-Charge. |
| 22 | S&F 4mm Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with nails to timber frame work in ceilings complete all as specified and directed by Engr-in-Charge. |
| 23 | M&L 75 mm thickPCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in plinth protection, floor, coping etc complete all as specified and directed by Engr-in-Charge. |
| 24 | M&L for 30mm thick 2nd class hardwood as in flooring planed one side, with butt joints and fixed with nails supplied and fixed complete all as specified and directed by Engr-in-Charge. |
| 25 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed of 15mm thick in CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 26 | M&L for Glazed ceramic coloured tiles in vertical surface 300x 200x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over screed bed of 10mm thick in CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 27 | M&L for preparation of newly plastered surfaces and applying three coats of white wash over a coat of chalk whitning as primer as in walls complete all as specified and directed by Engr-in-Charge. |
| 28 | M&L for preparation of newly plastered surfaces and applying two coats of cement base paint as in walls in camouflage pattern complete all as specified and directed by Engr-in-Charge.Note: The pattern of camouflage shall be approved by GE. |
| 29 | S&F Anodised aluminium window shutters with frames, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed by Engr-in-Charge. |
| 30 | S&F Anodised aluminium ventilator louvers with frames, without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. and including all necessary fittings complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-Charge. |
| 32 | M&L for 1st class hardwood plain, solid, straight chowkats and frames, brought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints and including all necessary fittings complete all as specified and directed by Engr-in-Charge. |
| 33 | S&F 30mm 1st class hardwood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers to chowkats complete all as specified and directed by Engr-in-Charge. |
| 34 | S&F 150mm long aluminium handles, cast type, anodised complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed by Engr-in-Charge. |
| 36 | S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed by Engr-in-Charge. |
| 37 | S&F aluminium (extruded section) door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 800 to 1200 mm in width and of weight between 61 to 80 kg complete all as specified and directed by Engr-in-Charge. |
| 38 | S&F 75mm long butt hinges, heavy weight, cold rolled mild steel, complete all as specified and directed by Engr-in-Charge. |
| 39 | M&L for preparation of new untreated surface and applying two coats of synthetic enamel paint over a coat of pink primer on woods complete all as specified and directed by Engr-in-Charge. |
| 40 | S&F vitreous china urinal, bowl type, size 465x355x265 mm complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe.(exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed by Engr-in-Charge. |
| 41 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engr-in-Charge. |
| 42 | S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) for fixing of WC and making good floor to match the existing surface complete all as specified and directed by Engr-in-Charge. |
| 43 | S&F Vitreous China wash basin, flat or angle back type, size 600x480mm, white, including cutting for and pinning in ends of brackets or erecting stand, waste coupling 32 mm PTMT, PVC waste pipe excluding taps, chain and plug and porcelain stopper but including brackets, Low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to walls complete all as specified and directed by Engr-in-Charge. |
| 44 | S&F PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cisternscomplete all as specified and directed by Engr-in-Charge. |
| 45 | S&F towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms)complete all as specified and directed by Engr-in-Charge. |
| 46 | S&F stainless steel soap dish any type fixed to plugs with chromium plated brass screws complete all as specified and directed by Engr-in-Charge. |
| 47 | S&F PVC connections 15mm size with PTMT nuts of length 300mm complete all as specified and directed by Engr-in-Charge. |
| 48 | S&F cast iron nahani trap 100 mm dia with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4, using 20mm graded crushed stone aggreagte) complete all as specified and directed by Engr-in-Charge. |
| 49 | S&F 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed by Engr-in-Charge. |
| 50 | S&F 15mm dia galvanised steel tubes, \"medium grade\" , with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engr-in-Charge. |
| 51 | S&F curtain rods, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed by Engr-in-Charge. |
| 52 | S&F 150 x 100 mm Salt-glazed stoneware gully traps, square or round mouthed, type \"P\" complete all as specified and directed by Engr-in-Charge. |
| 53 | M&L for providing Type B1 1:2:4 (20mm graded crushed stone aggregate) cement concrete as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engr-in-Charge. |
| 54 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed, in hard/dense soil complete all as specified and directed by Engr-in-Charge. |
| 55 | S&F 1000 ltrs PUF insulated water storage tanks (cyclindrical vertical with closed top) incl connecting up pipes securing access covers incl ball brass valves 20 mm, high pressure with polythene float and flynut etc complete all as specified and directed by Engr-in-Charge. |
| 56 | M&L steel work in tubular trusses as in post, trussess, purlin etc, incl special shaped washer etc, complete using ERW or induction butt welding tubes confirming to IS 1161-1998 grade St-240, complete all as specified and as directed by Engr-in-Charge. |
| 57 | M&L for 0.63mm thick Galvanised corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in lieu of screws complete all as specified and as directed by Engr-in-Charge. |
| 58 | S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, bearing plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engr-in-Charge. |
| 59 | S&F 20mm dia mild steel rag or lewis bolts screwed one end with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 15cm long but n.exc 30cm long complete all as specified and directed by Engr-in-Charge. |
| 60 | M&L for new untreated steel surface of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide/zinc chrome primer in camouflage pattern complete all as specified and directed by Engr-in-Charge.Note: The pattern of camouflage shall be approved by GE |
| 61 | M&L for 20 mm thick compressed foam filling in walls before wall panelling complete all as specified and directed by Engr-in-Charge. |
| 62 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness M-40 grade with grey cment and pigment complete all as specified and directed by Engr-in-Charge. |
| 63 | M&L for 2.5cm mouldings n. exc 75mm girth, on softwood complete all as specified and directed by Engr-in-Charge. |
| 64 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-Charge. |
| 65 | Excavation in post holes (or similar holes) each n exc 0.5 cu.m, getting out, returning, filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface in hard/dense soil, complete all as specified and as directed by Engr-in-Charge. |
| 66 | M&L for plain cement concrete type B2 1:2:4 (40 mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge. |
| 67 | M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed by Engr-in-Charge |
| 68 | Excavation over area n. exc. 1.5m depth and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge. |
| 69 | Excavation over area exc. 1.5m depth but n. exc 3.0m depth and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge |
| 70 | M&L for removing excavated materials exc. 250m but n.exc. 500 m and depositing where directed, complete all as specified and directed by Engr-in-Charge. |
| 71 | M & L Cement concrete in surface channel and drains intype C2 1:3:6 (40 MM graded aggregate) in manholes all as specified and as directed by Engr-in-Charge. |
| 72 | M & L for block masonry with solid pre-cast cement concrete blocks made out of cement concrete 1: 3: 6 type C-1, using 20 mm graded stone aggregate, 10 cm in width and setting in cement mortar 1 : 4 complete all as specified and directed by Engr-in-Charge. |
| 73 | M&L for Type 1:2:4 using (20mm graded aggregate) Precast cement concrete hollow block masonry exc. 10 cm in width and setting in mortar complete all as specified and directed by Engr-in-Charge. |
| 74 | M & L for Formwork to soffits of suspended slabssuch as roof slabs, floor slabs landings and similar work not exc.200 mm thick complete all as specified and directed by Engr-in-Charge. |
| 75 | M & L for Formwork to edges of concrete flats, breaks in floors, Window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc. 10 cm but n exc 20 cm wide all as specified and as directed by Engr-in-Charge. |
| 76 | M&L for rendering 20 mm thick in cm 1:3 on fair faces of block masonry /brick work surfaces complete all as specified and directed by Engr-in-Charge. |
| 77 | M&L for rendering 15 mm thick in cm 1:4 on fair faces of block masonry /brick work surfaces complete all as specified and directed by Engr-in-Charge. |
| 78 | Supply only for integral water proofing compound all as specified and as directed by Engr-in-Charge. |
| 79 | S&F Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; in CM 1:3:6 type C2 nominal mix (using 40mm graded aggregate) for 150 dia pipe complete all as specified and directed by Engr-in-Charge. |
| 80 | S&F Salt-glazed stoneware drain pipes 150 mm laid in trenches and jointed as specified as directed by Engr-in-Charge. |
| 81 | M&L for on site conventional LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete for 20 users all as specified and as directed by Engr-in-Charge. |
| 82 | Supply, laying and testing cable XLPE insulated , screened, PVC bedded galvanized steel strip or wire armoured,1100volts grade with stranded aluminum conductor of size 120 Sqmm 3.5 Core complete all as specified and as directed by Engr-in-Charge. |
| 83 | Excavation, in trenches not exceeding 1.5 mtr wide and not exc1.5 mtr in depth for layingunder ground cable n.exc 10 Sqm on plan and n.exc 1.5m in depth in in soft / loose soil and getting out complete all as specified and directed by Engr-in-Charge. |
| 84 | Removal of surplus excavated material to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 85 | Sand cushioning to under ground cable with dry sand locally available 8cm thick before laying the cable and 15 cm above the cable, stretching and testing of cable complete all as specified and directed by Engr-in-Charge.Note:-(i) Excavation and earth work to be measured and paid for separately(ii) Thickness of 18 cms after punning shall be considered for payment |
| 86 | M&L for PCC cable coverClass LV, Type I,flat,size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specified and directed.Note:-Excavation and earth work to be measured and paid for separately |
| 87 | Supply and laying pipe galvanized Medium grade including fitting 40 mm dia GI Pipe complete all as specified and directed by Engr-in-Charge. |
| 88 | Supply and laying pipe galvanized Medium grade including fitting 25 mm dia GI Pipe complete all as specified and directed by Engr-in-Charge. |
| 89 | Supply and laying pipe galvanized Medium grade including fitting 20 mm dia GI Pipe complete all as specified and directed by Engr-in-Charge. |
| 90 | Making branch connection of existing GI pipe of any size up to 40 mm GI pipe of any size including drilling of holesof suitable size welding and using clamps and other necessary materialscomplete all as specified and directed by Engr-in-Charge. |
| 91 | M&L for point wiring with 1.5 sqmm copper conductor FRLS (multistranded) PVC insulated and sheathed electric cable 1100 volt (ISI Marked) with proper color coding in and incl PVC concealed conduit with all accessories (ISI Marked) with all fittings/accessories and incl PVC insulated and unsheathed electric cable 1100 volt 1.5 Sqmm FRLS (multistranded) copper conductor cable(green color) as continuous earth wire connected to common earth dolly incl hard PVC boards of required size and shap and fiitings etc covered with 3mm thick Hylum sheet for one light point controled by one way switch complete all as specified and directed by Engr-in-Charge. Make of wire: Anchor/Polycab/Finolex/ Havells |
| 92 | All as per BOQ srl item no. 91.00here in before, but for one 3 pin socket outlet 5 Amp on independent board all as specified and directed by Engr-in-Charge. |
| 93 | All as per BOQ srl item no 91.00 here in before but 4 Sqmm copper conductor FLRS (Multistranded) PVC insulated and unsheathed electric cable 1100 volt (ISI marked) andd 4 Sqmm copper conductor as continuous earth wire for 3 pin socket multipurpose 5/15 Amps on indipendent board all as specified and directed by Engr-in-Charge. |
| 94 | All as per BOQ srl item no 91.00 here in before, but for One 3 pin socket outlet, 5 Amps on the same board with other switches,and completeall as specified and directed at site by Engr-in-charge. |
| 95 | S&F of Switchpiano,flushtype single pole, one way 5 Amp, and completeall as specified and directed at site by Engr-in-charge. all as specified and directed. |
| 96 | S&F 3 pin socket outlet,flushtype 5 Amp, and completeall as specified and directed at site by Engr-in-charge. all as specified and directed. Socketoutlet 3 pin, 5A, flush type |
| 97 | M&L forSwitch socket combination 2 in 1,5A flushtype, ( Box Type)and completeall as specified and directed at site by Engr-in-charge. |
| 98 | M&L for Switch socketcombination 2 in 1, 3 pin 5 and 15 Amps, 240 volts flush typeand completeall as specified and directed at site by Engr-in-charge. |
| 99 | Supply and fix energy efficient, environment friendly, LED tube light fittings surface/pendent mounting complete with white powder coated slim box batten of formed CRCA with snap on installers suitable for 1200 mm long T8 tubular LED lamp incl linear 1x20 W LED tubular lamp with PC body, diffuser and inbuilt driver, 220-240 V, 50 Hz, 6500K for white illumination including surge protection device all accessories and connectionwith flexible copper conductor three core cable from ceiling rose to connector all as specified and directed by Engr-in-Charge. |
| 100 | Supply and fixing ceiling fan1200mm sweep BEE 5star rated including electronic regultor with provision of cord flexible copper conductor 23/0.0076 three core from ceiling rose to connector complete all as specified and as directed by Engr-in-Charge.Make: Usha/Bajaj/Crompton Greaves/Almonard/Orient/Luminous/Havells |
| 101 | S&F sheet metal enclosure (factory made) for distribution boarddouble door TPN DB (MCBs are to be used) Triple pole and neutral 240 volt 4 way with 200 Amps reted bus bar all as specified and directed by Engr-in-Charge. |
| 102 | S&F MCCB TPN 40 Amps, incomer with breaking capacity 16 KA complete all as specfied and directed by Engr-in-Charge. |
| 103 | S&F MCB SP 6-32 Amps, 240 Volts with breaking capacity of 10 KA, C curve complete all as specfied and directed Engr-in-Charge. |
| 104 | Supply and fixing exhaust fan heavy duty steel body with louvers complete of 300mm size with bolts,nuts and washers, size of the bolt 15 cm long embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan for giving connection complete all as specified and directed bu Engr-in-Charge. Note: Cost of opening in wall and grouting of mild steel work shall be deemed to be included in quoted price by contractor.Make: Usha/Bajaj/Crompton Greaves/Almonard/Orient/Luminous/Havells |
| 105 | Supply and fix energy efficient LED, environment friendly LED street light B1 class for area/path illumination as per National lighting code ( SP 72:2010( by using security light of 35/36 W (total input power) CCT-5000-5500K CRI>67, PF>0.95, rated out put lumens not less than 100 Lumen per Watt, operating performance temp-30 degree centigrade +45 degree centigrade LED module life span 50000 burning hrs, with toughened glass, external surge and over voltage protection device up to 440V along with connection 3 core copper flexible cable of size 0.75 sqmm to be provided with weather proof connector. LED module & Driver IP-66 rated duly ISI marked IS:16103 part (1&2) 2012 : efficiency 85% constant current Vtd<10%, lthd<15% complete with 40 mm dia GI pipe light gde 1.5 mtr long bracket and Flat Iron 40x6mm clamp 2 Nos with nut bolts etc including painting of clamps with two coats of Aluminium paint over a coat of primer complete all as specified and as direcetd by engr-in-Charge. |
| 106 | Earthing complete with copper plate electrode 600x600x3.15mm thick electrode burried directly in ground not less than 3.0 mtr deep below normal ground level with top edge of earth plate not less than 2.5 mtr below normal ground level connected to and including and 20x3 mm copper strip as earth lead by means of bolt ,nuts, check nuts, and washers of stainless steel and duly welded incl PCC pit in PCC 1:2:4 type B-I angle iron 40x40x3mm frame, pit in PCC 1:2:4 type B-I cover 40mm reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20mm bore with funnel and wire mashand medium grade GI protectionpipe 40mm boreand earth wire up all as shown in electrical plate No 3 of MES SSR- Part-I all as directed and specified by Engineer-in-charge. Note:- (i) Water pipe shall be provided in slanting position.(ii) On testing after completion of the job if the desired earth resistance is not obtained then the contractor shall redo the earthing without incurring any extra cost to the government. No claim whatsover shall be admissible to the contractor on this account. |
| 107 | Supply, laying and testing of cable XLPE insulated , screened, PVC bedded galvanized steel strip or wire armoured,1100volts grade with stranded aluminum conductor of size 16 Sqmm 4 Core complete all as specified and as directed by Engr-in-Charge. |
| 108 | Supply installation testing and commissioning of LT control panel outdoor type factory made cubical totally enclosed type with front and rear door opening as per engineering practice provided with locking arrangement for opening. Size of panel having dimension not less than 150cm x 100cm x 50cm provided with footing 30 cm clear space between bottom of panel and flooring embedded in 40 mm thick PCC 1:2:4 type B -1 ( using 20 mm graded aggregate), panel made out of 2.0mm mild steel sheet and painted with powder coated paint over a coat of red oxide primer on angle iron of size 40x40x6mm with accessories prewired with insulated copper wire of suitable size complete all as specified and as directed by Engr-in-Charge. Make : Jaima Electrical/L&T The panel shall compromise of the following fittings and fixture :- (a) Aluminium busbar 250 amps for phases and neutral with colour code -04 Nos(b) MCCB 200amps 36 KA 415 volts - 01 No (Incoming)(c) MCCB 63amps 16 KA 415 volts - 02 No (out going)(d) MCB 32 amps 240 volts - 02 No (out going)(e) Digital volmeter 0-500V(f) Digital Ampere meter 0-400 A with suitable rating CTs(g) LED Neon indication lamp - 01 set |