}

Supply Of Medical Equipments Goods And Peripheral Items , Medical Equipments And Pheripherals Items , Electronic Digital Heamoglobinometer Should Be Ce / Usfda Approved Based On Principle Of Reflectance Photometry / Absorbance Photometry With Lcd, District Tehri Garhwal-Uttarakhand

Ministry Of Health And Family Welfare-MOHFW has published Supply Of Medical Equipments Goods And Peripheral Items , Medical Equipments And Pheripherals Items , Electronic Digital Heamoglobinometer Should Be Ce / Usfda Approved Based On Principle Of Reflectance Photometry / Absorbance Photometry With Lcd. Submission Date for this Tender is 12-08-2021. Coats and Jackets Tenders in District Tehri Garhwal Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

28668557
Corrigendum : Supply Of Medical Equipments Goods And Peripheral Items , Medical Equipments And Pheripherals Items , Electronic Digital Heamoglobinometer Should Be Ce / Usfda Approved Based On Principle Of Reflectance Photometry / Absorbance Photometry With Lcd
Open Tender
Indian
Uttarakhand
District Tehri Garhwal
12-08-2021

Tender Details

Supply Of Medical Equipments Goods And Peripheral Items , Medical Equipments And Pheripherals Items , Electronic Digital Heamoglobinometer Should Be Ce / Usfda Approved Based On Principle Of Reflectance Photometry / Absorbance Photometry With Lcd Display Result In G / Dl Measuring Range 0-20G / Dl Or Beyond Volume Of Sample Less Than 50 Micro Ml Sensitivity And Specificity More Than 80% Autocalibration Battery Operated Must Be A Serviceable Product With Minimum 1 Year Warranty And Service Network ( Chinese Parential Make Not Allowed ) , Electric Extension Board ( Should Be Iso / Ce Certified Co. ) , Episiotomy Scissser 6” ( Should Be Rust Proof And Fine Stainless Steel Instrument Tufft / Asco / Sisco Make Perferd ) , Large Tooth Forcep ( Should Be Rust Proof And Fine Stainless Steel Instrument Tufft / Asco / Sisco Make Perferd ) , Stethoscope ( Stainless Steel Dual Head Chest Piece Made From 303 Grade Stainless Steelpvc Tubing With Spare Diaphragm & Soft Ear Tips Minimum Diaphragm 4.5Cm ) , Mercury Thermometer ( Should Be Branded And Isi ) , Feotaldopler• Large And Clear Lcd Display With Backlight • Light Weight And Portable Device Ensures Ease Of Use • 3 Diffirent Methods Of Operation • 2.5Mhz Lightweight Water Proof Probe Fhr Range: 50-210Bpm • Built In Li-Ion Rechargeable Battery With Working Time Minimum 6 Hrs. • Ideal For Overweight Mothers, Can Be Used For Water Births Too. • Device Comes With Head Phone Socket And In Built Loudspeaker. • Product Should Be European Ce / Iso / Fda • Chinese Parentialmake Not Allowed , Room Heater Pillar ( Heat Piller 2 Carban Rod Aproxhight 2Ft 2000W Should Be Branded And Isi Marka Chinese Parential Make Not Allowed ) , Pulse Oximeter Spo2 And Pulse Rate Monitor Integrated Into Finger / Toe Clip. Required To Apply To Adults And Children, And All Skin Pigmentations. Spo2 Detection To Include The Range: 70–99%., Spo2 Resolution: 1% Or Less. Spo2 Accuracy ( In The Range At Least 70–99% ) : Within ± 3%., Capable Of A Wider Spo2 Detection Range, The Accuracy Over That Wider Range Shall Be Stated. Pulse Rate Detection To Include The Range: 30–240 Bpm. Pulse Rate Resolution: 1 Bpm Or Less. Accuracy Within ± 3 Bpm. Suitable For Detection In Low Perfusion Conditions ( As Per Iso 80601-2-61, Test Method Must Be Described ) . Design Must Enable Use In Demanding Environments, E.G. Shock, Vibration And Free Fall Tests As Per Tests In Iso 80601-2-61., Available Probe Sizes Must Accommodate Finger / Toe Thicknesses At Least Including The Range 8–25 Mm. Automatic Correction For Movement, Ambient Light Artefacts ( As Per Iso 80601-2-61, Test, Display Shows % Spo2, Pulse Rate, Signal Quality, Sensor Error Or Disconnect And Low Battery Status. Enclosure To Have Ingress Protection Level Ipx2 Or Better. , Any Aspects Of Usability As Per Iec 62366-1 Must Be Described. Disinfectable With Hospital Grade Detergents. Automatic Power-Off Should Be Ce / Iso / Fda Approved Chineesparentialmake Not Allowed , Digital Tharmometer ( Should Be Branded Iso / Ce Certified ) , Thermal Scanner ( Make In India Fda / Ce Approved: Measurement Mode – Non-Contact; Measuring Distance 5-10Cm; Measurement Range 32Degree C To 42.9 Degree C ( 89.6 Degree F To 109.2 Degree F ) . ; Dc3v ( 2X Aaa Battery ) ; Operating Temperature – 10-40 Degree C ( 50 To 104 Degree F ) ; Storage Conditions– ( -20 Degree C – 55 Degree C ) ( -4 Degree F- 131Degree F ) Rf93% ; Automatic Shut Off Time – Within 20 Seconds ; Working Conditions – ( 16 Degree C – 35 Degree C ) ( 60.8 Degree F – 95.0 Degree. Should Be Iso / Ce / Fda Approved Make In India. Chinese Parential Make Not Allowed ) , Baby Warmer ( Feature Available:- Display Skin Set, Friendlytouch Panel Control, Warmer Head Should Be Rotatable In Different Direction. So As To Allow Taking X-Ray, Observation Light Luminance And Color Temperature:- >=1000Lux, Colour Temperature Range From 3700K To 5100K, Battery Back Up Facility For Power Failure Indication During Power, Temperature Range 25 To 40 Degree C, Settable Temperature 32 To 38 Deg C, Facility To Lock The Keyboard, Separate Bassinet Trolley, X-Ray Cassette Holder, Touch Operation With Large Digital Display And Comprehensive Alarms, Control Panel Should Be Liquid Proof , Easy And Hygienic Disinfection, Overall Height Of Equipment 1800, Width 450, Length 600 Weight 45, Power 220 To240v, 50Hz Ac, + 10% Of Input, Certificates Ce European, Warranty 2 Years. Chineesparentialmake Not Allowed ) , Four Seater Bench ( Airport Type Chair Crome Finish With Stainless Steel Base Colour Silver Size: 64 X 180 X 80Cm ) , Examination Table Gyne ( Examination Tablegyne ( 183L X 51W X 81H ) Frame Work Of Crc Tubes Legs Fitted Pvc Stump. Crc Sheet Top In Two Section Back Rest Section Adjustable On Ratchet U-Cut On One Section With Lithotomy Poles Pre Treated And Epoxy Powder Coated Finish With Mattress ) , Instrument Bowel 12” ( Should Be 12” Stainless Steelaprox Weight 250Gm ) , Iucd Insertion Set ( Should Be Stainless Steelinstrument ) , Patientstool ( Patient Stool Revolwing S.S.Top Height 45Cm And Max 68Cm. M.S. Tubular Four Leg Fitted With Pvc Stumps Foot Ring Supports 18To 27 Adjustable Height S.S. Top Through Screw Pre Treated Epoxy Powder Coated Finish ) , Weighing Machine With Infantometer ( Scale. Table Top, Light And Portable. Digital Weighing Machine 2. Built In Rechargeable Battery. 3. Easy To Clean Baby Tray ( Acrylic ) . 4. Zero Weight Adjustment Facility. 5. Quick, Clear Digital Read Outs. 6. Measurement Does Not Change With Position Of Baby On The Pan. 7. Provision To Measure The Height Of The Baby In Its Laying Position. 8. Accuracy: 5G, Resolution: 1G, Limit: 10Gm To 15Kg. 2.2 Settings Auto Setting To Once A The Machine Is Switched On Or When No External Weight Has Been Put On. 2.3 Users Interface Lcd / Led Display 2.4 Software And / Or Standard Of Communication ( Where Ever Required ) In Built Physical Characteristics 3. 3.1 Dimensions ( Metric ) Base: 300Mm X 265Mm X 85Mm ± 20%, Pan: 510Mm X 300Mm X 85Mm ( Minimum ) . 2 Weight ( Lbs, Kg ) Na 3.3 Configuration N.A. 4 Noise ( In Dba ) N.A. 3.5 Heat Dissipation Na 3.6 Mobility, Portability Portable ) , Hub Cutter ( Manual Hub Cutter With Stand Or Table Top Model 3Ltr Capacity Made By Polycarbonate Material ) , Ticker Bag , Colour Coding Bucket Four Colour ( Made By High Grade Vergin Plastic Foot Operated 50Ltr Size: 42L X 47W X 65Hcm Material 100% Vergin Hdpe With Center Foot Pedal With Lid ) , Water Filter Purifier ( Should Be Branded ) , Bp Instrument Aneroidbp Instrument Aneroid Clock Type Corrosion Resistant Shock Proof Body, Chrome Plated Metal / Stainless Steel Pressure Control Valve, Scale 0-300 Mm Hg. Air Release At Closed Lap With Maximum 4Mmhg / Minute. Manual Setting Of Deflation Possible Upto 2 / 3Mm Hg / Sec. From 260Mmhg. To 15Mm Hg In A Maxium Deflation Time Of 10 Seconds. Gauge’S Background In White Colour. Graduated Scale For Ever / 2Mmhg, Every 10 Units And Every 20 Units. Nylon Straps Cuff With Pouch, Latex Bulb With Completely Chromium Plated Valve With Regulation Of Vent-Hole Air By Screw Valve. 2.2 Settings The Cuff Is Inflated Just To Fit In The Limb For Which An Inflation Bulb Is Used To Control The Air Pressure Within The Cuff. 2.3 3. 3.1 Dimensions ( Metric ) The Rubber Tubes Used Should Have An Internal Diameter Of 3 ± 0.5Mm And The External Diameter Should Not Be Less Than 8Mm; The Dial Mano Meter With Minimum 6” Should Be Branded Iso / Ce Approved Company Chineesparentialmake Not Allowed , Labour Table ( Obestetric Labour Table Hydraulic Telescopic Type ( 72 X 27 X 30 ) Complete Stainless Steel Obestetric&Labour Table With Three Section Table Top. Legend Section Can Slidecompletely Underthe Main Section, Facility For Trendelburg Position, Backrest Adjustable On Ratchet Systemcompletewith Side Railings, Hand Grips & Lithotomy Rods With Straps All Part S.S. ) , Suction Machine ( 0 To - 760 Mm Hg ± 10 Regulable, 1 / 2 Hp; Single Phase 1440 Rpm Motor; Flutter Free Vacuum Control Knob, ; Wide Mouthed 2 X 2 Litre ( Light Weight, Unbreakable And Clear ) With Self Sealing Bungs And Mechanical Over Flow Safety Device. 2.2 Settings Manual 2.3 Users Interface Manual 4 Software And / Or Standard Of Communication ( Where Ever Required ) Na Physical Characteristics 3. 3.1 Dimensions ( Metric ) Max: 43 X 30 X 68 Cms 3.2 Weight ( Lbs, Kg ) Max: 27Kg 3.3 Configuration Na 3.4 Noise ( In Dba ) 50 Db A ± 3 3.5 Heat Dissipation Should Maintain Upto 36.5 Deg Temp And The Heat Disbursed Through A Exhaust Fan 3.6 Mobility, Portability Yes Energy Source ( Electricity, Ups, Solar, Gas, Water, Co2 .... ) 4. 4.1 Power Requirements 220 V, 50 Hz, 2 ± 0.5 Amps, 370 Watts For Ac 4.2 Battery Operated Na 4.3 Tolerance ( To Variations, Shutdowns ) Voltage Corrector / Stabilizer To Allow Operation At ± 30% Of Local Rated Voltage. Use Of Smps To Correct Voltage. 4.4 Protection Electrical Protection By Resettable Overcurrent Breakers Or Replaceable Fuses, Fitted In Both Live And Neutral Lines. Power Consumption Should Run With Other Life Savingequipments Running Parallelly. 4.6 Other Energy Supplies Na Accessories, Spare Parts, Consumables 5. 5.1 Accessories & Spares Collection Container & Its Cap, Suctions Tube Tips, A Vacuum Gauge, Two Sets Of Moisture & Microbial Filters And Control Knob. 2 Consumables / Reagents ( Open, Closed System ) Siliconetubing:8 Mm Id X 2 Mtr ( Pvc ) , 2X2 Lt Jar ( One Set Extra ) Warranty And Maintenance 9.1 Warranty 3 Years 9.2 Maintenance Tasks Maintainance Manual Detailing Complete Maintaining Schedule. 9.3 Service Contract Clauses. ) , Otoscope Imported ( Should Be Imported Branded Welch Allin / Keeler / Heign Should Be Usfda Approved ) , Delivery Tray ( Should Be Seamless Stainless Steel Tray Size: 10’ X 12”, 12”X15” ) , Portablegenerator ( Should Be Branded ) , Oxygen Flow Meter ( Should Be Branded Iso / Ce Marka ) , Oxygen Mask ( Should Be Branded ) , Wheel Chair Folding ( Model Width Length Height, Folding Wheel Chair 600 Mm X 790 Mm X 870 Mm , Folding Wheel Chair With Cushion 600 Mm X 790 Mm X 870 Mm. Sturdy Structures. High Load Bearing, Foldable Designs For Space Optimization, Durable Wheels. Wheels, Brake Handles Provided. ) , Spray Machine ( Should Be Branded Aprox 20Ltr Hanging ) , Nebulizer ( Should Be Branded Iso / Ce Not China Make ) , Ecg Machine 3 Channel• Machine Recording Of Simullaneous 3 Channel Ecg Recording With 12 Lead Simultaneous Acquisition. • It Should 3.5” Colour Lcd Screen • It Should Have Built In Ecg Parameters Measurments And Interpretation Algorithm. • Machine Should Built In Thermal Dot Matrix Printer. • Print Mode: Pre Sample / Real Time Sample / Arrhythmia Triggered Sample. • Machine Should Store Up To 200 Ecgs In Internal Memory • Should Be Compact And Light Weight 2.5Kg. • Recording Speed Selection Of 2.5, 5, 10, 20 Mm / Mv+-5% ( Manual Mode ) • Sensitivity In Auto Mode Optimizes Automatically To 2.5, 5, 10-20Mm.Mv+-5% • Digitalyfiltring Remove Interference From Power Line Muscle Tremor, Etc With Automatic Base Line Correction. • Support External Archving: Usb Drive For Virtually Unlimited Ecg Data Storage: Usb Port Select Hp Printer Only. • Built In Rechargeable Lithium Ion Battery 3Hr Or 200 Continous Patient Recording • Recording Paper 80Mm Role Thermal Paper Lenth 20Mm • Equipment Should Be European Ce With Four Digit Notified Body No. / Ec Declration. Of Conformit / Usfda / Or Bis Approved • Manufacturer Should Have Iso 13485 • Copy Of The Certificate To Be Enclosed • Chinese Parential Make Not Allowed , Ecg Machine 12 Channel • Machine Recording Of Simullaneous 12 Channel Ecg Recording With 12 Lead Simultaneous Acquisition. • It Should 5.7” High Resulution Foldable Screen • Qwerty Alphanumeric Keyboard. • It Should Have Built In Ecg Parameters Measurments And Interpretation Algorithm. • Machine Should Built In Thermal Dot Matrix Printer. • Print Mode: Pre Sample / Real Time Sample / Arrhythmia Triggered Sample. • Machine Should Store Up To 100 Ecgs In Internal Memory • Should Be Compact And Light Weight 2.5Kg. • Recording Speed Selection Of 2.5, 5, 10, 20 Mm / Mv+-5% ( Manual Mode ) • Sensitivity In Auto Mode Optimizes Automatically To 2.5, 5, 10-20Mm.Mv+-5% • Digitalyfiltring Remove Interference From Power Line Muscle Tremor, Etc With Automatic Base Line Correction. • Support External Archving: Usb Drive For Virtually Unlimited Ecg Data Storage: Usb Port Select Hp Printer Only. • Built In Rechargeable Lithium Ion Battery 3Hr Or 200 Continous Patient Recording • Recording Paper 80Mm Role Thermal Paper Lenth 20Mm • Equipment Should Be European Ce With Four Digit Notified Body No. / Ec Declration. Of Conformit / Usfda / Or Bis Approved • Manufacturer Should Have Iso 13485 • Copy Of The Certificate To Be Enclosed • Chineesparentialmake Not Allowed , Iv Stand ( Saline Stand ( I.V.Stand ) Stainless Steel Tubular Pipe Five Leg Base With 5Cms Castor S.S.Adjustable Rod With Double Hook. ) , Paediatric Bp Cuff ( Should Be Branded ) , Glucometer ( Should Be Iso / Ce / Fda Approved Branded With Free Strip ) , Ambu Bag ( Should Be Branded Like Romsons Made By Best Quality Sililcon Base 500Ml, 750Ml, 1500Ml. ) , Oxygen Cylinder Trolly ( Cylinder Trolley Small Tubular Frame Work Two 10Cm Castor M.S.Sheet Base Plate Pretreated Epoxy Powder Coated Finish ) , Bed Side Locker Deluxe ( Bed Side Locker ( Deluxe ) 36L X 40W X 81Cms Made By Heavy Tubular Pipe Construction With Three Side Closed With Drawer And Cabinet Fitted Pvc Stumps Assembled To M.S. Cupboard Stainless Steel Top ) , Foot Step Double ( Foot Step Double ( 50X40X40 ) M.S.Tubular Legs Fitted With Pvc Stump M.S.Top Fixed With Rubber Matting ) , Vaccine Vial Opener ( Should Be Branded ) , Scisser Dressing 6” ( Should Be Rust Proof Tufts / Sisco / Asco Make ) , Multi Para Monitor 5 Para ( Patient Monitorwith Masimo Spo2·      Multiparameter Patient Monitor Which Is Suitable For Use In Adult, Paediatric& Neonate Applications·       Standard Configuration Of Ecg, Respiration, Masimo Spo2, Nibp, Temperature, Standard Configuration Of Ecg, Respiration, Masimo Spo2, Nibp, Temperature, Should Have Minimum 12-Inch Color Lcd Display ·  Ecg: ? Should Be Able To Monitor 12-Lead Ecg Of The Patient ? Monitor Should Have Arrythmia Analysis Function Which Should Detect Total Of 26 Different Types Of Arrythmia ? Should Have Advanced St-Segment Analysis Window • Spo2 Monitoring Should Be Of Masimo Technology • Nibp: ? Should Have Auto, ( Measurement Method- Automatic Oscillometry ) Manual And Continual Modes Of Operation For Nibp. ? Monitor Should Have Nibp Analysis Window. • Respiration: ? Should Follow Thoracic Impedance Method For Respiration. ? Should Have Respiration Rate Of 0-150 Rpm For Neonates And 0-120 Rpm For Adult / Children. ? Should Have User Selectable Apnea Alarm Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 1Min.Patient Monitorwith Masimo Spo2 • Multiparameter Patient Monitor Which Is Suitable For Use In Adult, Paediatric& Neonate Applications • Standard Configuration Of Ecg, Respiration, Masimo Spo2, Nibp, Temperature, • Should Have Minimum 12-Inch Color Lcd Display • Ecg: ? Should Be Able To Monitor 12-Lead Ecg Of The Patient ? Monitor Should Have Arrythmia Analysis Function Which Should Detect Total Of 26 Different Types Of Arrythmia ? Should Have Advanced St-Segment Analysis Window • Spo2 Monitoring Should Be Of Masimo Technology • Nibp: ? Should Have Auto, ( Measurement Method- Automatic Oscillometry ) Manual And Continual Modes Of Operation For Nibp. ? Monitor Should Have Nibp Analysis Window. • Respiration: ? Should Follow Thoracic Impedance Method For Respiration. ? Should Have Respiration Rate Of 0-150 Rpm For Neonates And 0-120 Rpm For Adult / Children. ? Should Have User Selectable Apnea Alarm Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 1Min. • Temperature: ? Should Have Dual Channel For Temperature Measurement. ? Should Have A Temperature Measurement Range Of 0-50 Degrees Celsius. ? Should Have An Accuracy Of ±0.1 Celsius. • Monitor Should Have Calculation Interfaces Like: Drug Dose Calculation, Hemodynamic, Ventilation, Oxygenation, Renal Calculation. Monitor Should Have Standard Hl7 Protocol, Integrate With Central Nursing Station, Nurse Call System, Slave Display And Has Defibrillator Synchronization Output Connector. Trend Data & Screen Shot Can Be Transfer To Usb • Should Have Work Mode Of Standby, Night Mode, Privacy Mode. • Monitor Should Have Extensive Data Storage Capabilities: 72 Hours Of Trend Data, 2000 Groups Of Nibp, 200 Alarm Review, 200 Arrhythmia Recall, Full Discloser Of All Leads Of Ecg For Min 1 Hr, . • Should Have Physiological And Technical Alarms. • The Monitor Should Have Advanced And Smart Alarm Management System For The User To Prioritize The Alarm Through 3 Levels Of Alarm. • Should Have Li-Ion Battery For Atleast 3.5 Hours. • Power Supply: 100-240 V, 50 Hz • Attached European Ce / Iso Certificates • Chinese Parential Make Not Allowed , Towel ( Towel Should Be Fine And Soft Hevy Quality Coloured & White Size: 27” X 54”. 400 To 600 Gsm ) , Blanket Green / Red / Camel ( Soft Woolen Blanket 80% Wool And Rest 20% Other Fiber, Size 60”X 90”. Weight 1500Gm, Stiching Hemmed Two Sides. ) , Bed Sheet Green ( Bed Sheet Green Cashment Cloth Heavy Fine Karoor Tamil Nadu ) , Dustbin 15Ltr Foot Operated ( Should Be Vergin Plastic Foot Operated 15Ltr Capacity ) , Patient Gown ( Made By Green Cashment Cloth Heavy Fine Karoor Tamilnadu ) , Foot Mats ( Size: 3Ft X2ft Should Fine With Juit Heavy Coverd With Leather Border ) , Duster 24” X 18” ( Should Be Pure Cotton Heavy And Soft ) , Bmw Garbaj Bag ( Should Be 100% Biodegradable Minimum 50Micron All Colourgarbaj Bag Should Be Iso / Ce Certified Co. ) , Bed Side Pan ( Stainless Steelbed Pan Male / Female ) , Autoclave12” X 20” Ss ( Stainless Steel Autoclave High Pressure Vertical Autoclave Triple Chamber With Inner Chamber And Steam Jacket Made Of Thick Stainless Steel Jacket. All Sterlizers Are Hydraulically Tested Upto 2.5 Times Of Working Pressure. Outer Chamber Made Of S.S.Sheet Reinforced With M.S.Sheet.Lid Is Made Of Thick Stainless Steel Plate Sigle Piece And Closed By Wing Nuts Arrangement Jointless Neoprene Gasket Does Not Allow Any Leakage.Fitted With Double Safety Valve, Water Level Indicator 12 X 20 2 Element Load 2Kwtotal Load 4Kw ) , Semi Fowler Bed With Mattress ( Hospital Semi Fowler Bed Deluxe ( Size:198L X 90W X 60H Cms. Frame Work Of Strong &Precis Steel Tubes Having H Type Legs On Rubber Stump. Having Two Section Top Of Perforated Crca Sheet Duly Machine Press Bent, With Mattress Guard. Absblue In Colourpannals Fitted With Detachable Foot And Bow. Backrest Section Maneuvered By Crank Mechanism From Foot End Provision For Four Location For I.V. Rod With Epoxy Powder Coated Finish. With Two Fold 4” Thick Mattress. ) , Infant Radiant Heat Warmer Open Care System ( Infant Radiant Warmer Open Care System With Servo / Air And Manual Mode A Big Lcd Is Provided For More Information And Visualizations Of The Heater Power In Manual And Servo Modes. A Full Complement Of Alarms Provides Safety And Convenience, With Both Audible And Visuals Indicators In The Events Of ( I ) High Temp / Low Temp ( Ii ) System Fail ( Iii ) Probe Failure ( Iv ) Power Failure Timer The Oval Round Heater Assembly Located Above The Centre Of The Support Structure Consists Of Dual Examination Light And A 650 Watts Heating System / Ceramic Heater ) For Quick Warning And Even Distribution Of Heat On The Baby Bed. The Heater Can Be Swiveled In Either Direction For Taking X-Ray And Doing Procedure The System Comes With Air Sensor. This Is Added Security Cover With Exclusive Feature Of Switching Off The Heater In Case The Air Temperature Goes 39°C Irrespective Of What The Skin Temperature At The Time Of Events. In Manual Mode Heating Starts From 40% In Manual Mode And The Same Can Be Change Through Settings Up To 100%. The System Automatically Converts From Servo Mode To Manual Mode In Case Of Probe Failure. Specious Oval Baby Bed Incorporates Easy Drop Down Glasses For Maximum Access To The Patient. With Inbuilt Pneumaticslow Suction, O2 Delivery , System The System Is Fitted 4” High Quality Castors Having Brakes In Front 2 Castors. Baby Bed Should Have Continuous Jerk Free Movement With Help Of Gas Spring. Should Be Fitted With Two Drawers System Which Slides Out For Keeping Consumables. With Undersurface Led Phototherapy Should Be All Series Ofiso 9000, 13485 Etceuropean Ce, Iso 13485, Iec 60601 Certificate Attached In Tender 2 Year Warranty Chineesparentialmake Not Allowed , Kelly’S Pad ( Should Be Branded Fine Rubber ) , Revolwing Chair ( High Back Ex Chair With Good Looking Fine Imported Leather Finish With Fine Imported Wooden Finish Crome Base And Good Lumber Supporthaving Socker Base Mechananism Push Back Chair ) , Plastic Chair ( Plastic Chair With Arm Should Be Branded Made By Vergin Plastic Colour Brown / Beige ) , Office Chair ( Ex Visitor Chair Made Of Heavy . Round Stainless Steelframe Imported Look Pu Seat & Back Frame Work With Fine Soft Handle And Frame Fine Italinan Leather Finish ) , Office Table 4Ft X 2.5Ft ( Frame Made Of Crca Ms Tubular F Rame Single Drawer Unit On Right Side Made Of Crca Ms Sheet Solid Wooden Top Aprox 1” Thick Top Powder Coated Finish Heavy ) , Steel Almirah Big ( Should Be Iso Certified Co. Ms Poweder Coated Finish With 5 Shelves Made By 22G Ms Sheet Size: 1980X860x485mm ) , Instrument Cabinet ( Instrument Cabinet Made From Crc Sheet Three Side Closed Front Glass Door And Glass Shelves Pretreated E.P.Coated 58 X 24 X 14 With 4 Glass Shelves ) , Celling Fan 48” ( Bajaj / Havels / Usha ) , Table Fan ( Bajaj / Havels / Usha ) , Electric Kettel ( Should 1.2Ltr Branded Isi ) , Invertor 1650 Kva ( Luminious Brand ) , Printer Laser ( Hp / Brother / Cannon ) , Sterilizer 18” ( Instrument Sterlizer Electrically Operated Stainless Steel Fine Quality 18 X 8 X 7.5 ) , Exhaust Fan ( Should Be Branded ) , Water Tank 1000 Ltr ( Triple Wall ) , Wall Clock ( Ajanta / Rikho ) , Dressing Trolly Ss ( Frame Work Of Stainless Steel On 10Cm Castor Two S.S. Shelves With Four Side Railings On Top Shelf Provision For Holding The 6 Two Bowel Push Handle At The One End Of The Trolley Size: 76L X 46W X 85Hcms ) , Syringe Infusion Pump ( Clinical Performances Should Accept All Internationally Produced / Marketedsyringes And Should Be Able To Detect It Automatically, Should Support The Bolus Supply Of Drug On Press Of Single Button, As Per Need And Should Be Able To Preset Different Range Of Bolus Supply. Preferably The Unit Should Be Of Bottom / Side Loaded To Avoid Accidental Spilling Of Drugs And Damage To The Machine. 2.2 Technical Characteristics ( Specific To This Type Of Device ) 1. Flow Rate Programmable Range At Least From 0.1 To 200 Ml / Hr, In Steps Of 0.1 Ml / Hr; And At Least From 100 To 1200 Ml / Hr In Steps Of 1 Ml / Hr. 2. Saves Last Infusion Rate Even When The Ac Power Is Switched Off. 3. Bolus Rate Should Be Programmable To Approx 500 Ml, With Infused Volume Display. 4. Selectable Occlusion Pressure Trigger Levels Selectable From 300, 500 And 900 Mmhg. 5. Must Work On Commonly Available 20, 30 And 50 Ml Syringes 6. Accuracy Of ±2% Or Better. 7. Maximum Pressure Generated = 20 Psi. 8. Automatic Detection Of Syringe Size And Proper Fixing. 9. Anti-Bolus System To Reduce Pressure On Sudden Release Of Occlusion. 10. Pause Infusion Facility Required. 11. Self-Check Carried Out On Powering On. 12. Comp Rehensive Alarm Package Required Including: Occlusion Alarm, Near End Of Infusion Pre-Alarm And Alarm, Volume Limit Prealarmand Alarm, Low Battery Pre-Alarm And Alarm, Ac Power Failure, Drive Disengaged, Syringe Loading Error, Maintenance Required. 13. Should Include Kvo ( Keep Vein Open ) Enabling Feature. 14. It Should Be An Open System Compliant. Settings Single Loadable With One Syringe Of Minimum 20Ml. 2.4 Users Interface Automatic 2.5 Software And / Or Standard Of Communication Inbuilt.Physical Characteristics 3. 3.1 Dimensions ( Metric ) Na 3.2 Weight ( Lbs, Kg ) Na 3.3 Configuration Tamper-Resistant Case Made Of Impact Resistant Material. Securely Mountable On Tabletop, Iv Stand Or Bed Fitting. 3.4 Noise ( In Dba ) Noise Free 3.5 Heat Dissipation 3.6 Mobility, Portability Yes Energy Source ( Electricity, Ups, Solar, Gas, Water, Co2 .... ) 4. 4.1 Voltage ( Value, Ac Or Dc, Monophase Or Triphase ) 220 To 240V, 50 Hz 4.2 Battery Operated Internal Rechargeable Battery Having At 4 To 6 Hours Backup For 10Ml / Hr Flow Rate With 50Ml Syringe. 4.3 Tolerance ( To Variations, Shutdowns ) 10% 4.4 Protection Battery Powered Alarm Forpower Failure Or Disconnection. 4.5 Power Consumption 25W 4.6 Other Energy Supplies Na Accessories, Spare Parts, Consumables 5. 5.1 Accessories ( Mandatory, Standard, Optional ) Clamp For Mounting Pump On Iv Stand. 5.2 Spare Parts ( Main Ones ) 5.3 Consumables / Reagents ( Open, Closed System ) Battery, Syringe Holder, Pmo Lines. Warranty And Maintenance 9.1 Warranty 3 Year 9.2 Maintenance Tasks Advanced Maintenance And Calibration Tasks Required Shall Be Documented. 9.3 Service Contract Clauses, Including Prices Local Clinical Staff To Affirm Completion Of Installation. Should Be European Ce / Usfda Approved Product Chinese Parential Make Not Allowed. ) , Gastric Lavage Tube ( Should Bebranded Co. Romsons, Polymed ) , Paediatric N.G. Tube ( Should Bebranded Co. Romsons, Polymed ) , Paediatric Nasal Prong ( Should Bebranded Co. Romsons, Polymed ) , Paediatric Drip Set ( Should Bebranded Co. Romsons, Polymed ) , Fully Automated Biochemistry Analyzer Fully Automated, Random Access Analyzer For Biochemistry &Immunoturbidimetry • Throughput Of 100-120 Tests / Hour In 1 Or 2 Reagent Assays • Innovative Drawer-Style Reagent & Sample Unit With On-Board Cooling And On-Line Inventory Management • 50 Reagent Positions And 22 Sample Positions Which Can Be Integrated Up To 71 Positions Each • Multi-Functional Probe For Aspiration, Dispensing, Mixing , Level Sensing And Collision Protection • 48Reusable Reaction Cuvettes • Equipped With 8 On-Board Wavelengths • Automatic 6 Stage Laundry Makes It A True-Walk-Away System With An Ability To Handle A High Work Load • Extremely Compact Footprint To Save Lab Space • Offered With A Range Of Ozosense System Packs With Excellent Onboard Performance • Extremely Powerful Yet Easy To Use Software • Two Year Warranty • Should Be Iso, Ce, Certified Product • Should Be European Ce Approved • Chineesparentialmake Not Allowed , Semi Automated Biochemistry Analyzer Testthroughput 60-85 Photometrictests / Hr 180 Isetests / Hr 60-100 Tests / Hr Photometric And Isemixed Sample Types Serum, Plasma, Urine, Whole Blood ( Hba1c ) Sample Input Continuous Loading Of Primary And Secondary Tubesinto 8 Samplepositions Priority Statsampling Time Of Firstresult 5-10 Min For Photometricmeasurements 2Min For Isemeasurements Sample Containertypes Primary Tubes 5-10Ml; 16X100, 16X75, 13X100, 13X75 Sample Cup2.5Ml Micro Cup1.5Ml Cup On Tube Cup On 16X75mmtube False Bottomtube Sample Volume Min. Sample Volume: Primary Tubes500µl Sample Cup75µl Micro Cup50µl Sample Barcodetypes Code 128, Codabar 2 Of 7, Interleaved 2 Of 5, Code 3Of0 9 Sample Dilution 1.2-100Times Photometer 12 Wavelengths, 20 W Halogen Lamp, Monochromaticand Bichromatic Measurement Measurementprinciples Absorbance Photometry ( Enzymens, Substrates, Specific Proteins ) Ion Selective Electrode, Indirect Measurement ( Dilution 1:6 ) Reagents Ise:Na+, K+, Cl- 2D Barcoded System Reagent Bottles, 50-200 Tests / Bottle Photometric: 27 Onboard Reagent Positions For Approx.14 Assays Up To 8 Exchangeable Reagent Discsavailable Reactioncells Disposablemicro-Cuvettes Controlunit 5.7 Color Touch-Screen Lcd ( 1 / 4Vga ) Systeminterfaes 2 X Rs 232 Serial Interface, Bi-Directional ( Astm Protocol ) Or Host And Barcodescanner 2 X Usb 1.1 / 2.0 For Modem And Memory Stick ( Data Loading Andbackup ) Electricalrequirements Line Voltage 100-125 V And 200-240 V Ac ( -15%, +10% ) Line Frequency 50 Hz ( ±5% ) And 60 Hz ( ±5% ) Power Consumptin 250 Va ( 320 Va Withise ) Installation Category Ii ( Iec61010-1 ) Physicaldimensions Width: 590 Mm ( 720Mm ) ( Withise ) Height: 480 Mm ( 480Mm ) Weight: 32.3 Kg ( 35Kg ) Externalprinter Printer Tool Software Available To Enabledata Transmission From The Instrument To Nearly Every Standardpersonal Computer Waterrequirements Up To 3 Litres / Day Nccls Type Ii ( Conductivity <1Μs / Cm At25°C ) Regulatoryrequirements Gs, Ce, Ul, C-Ul Opensystem Development Channel With 1, 3 Or 5 Channelsavailable Certification Should Be European Ce / Usfda Approved Product, Iso Chineesparentialmake Not Allowed, , 6-Part Haematology Analyzerfeatures • Compact, Powerful And Affordable • 29 Parameters, 6-Part Differentiation • Up To 80 Samples Per Hour • 20 Μl Sampling Volume • Whole Blood, Capillary Blood And Prediluted • Rack Closed Tubes / Manual Opened Tubes • Reagent Inventory Management Thru Rfid • Large Lcd Display ~ 15“ • Connectable To Lis Parameters • Wbc, Lym, Lym%, Mon, Mon%, Neu, Neu%, Eos, Eos%, Bas, Bas%, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Pdw, Mpv, Pct, P-Lcr, P-Lcc; • 4 Research Parameters: Aly, Aly%, Lic, Lic% • 1X 3D Scattergram, 3X 2D Scattergram • And 3 Histograms Methods Of Measurement • Impedance Method For Wbc, Rbc, Plt Counting; Independent Basophil Channel • Semiconductor-Laser-Based Flow Cytometry For White Blood Cells Differential • Colorimetric Method For Hemoglobin Using Cyanide-Free Reagent Calibration And Control • 3 Modes Of Calibration: Manual, Automatic Using Calibrator, Automatic Using Fresh Blood Samples • 3 Levels Of Control Blood ( Low, Normal, High ) For Daily Quality Control Measurement With Levey-Jennings Charts • User Definable Qc Range Should Be European Ce / Usfda Approved Product Chinese Parential Make Not Allowed , Full Automated Esr Analyzer ( Esr Analyzer Working On Infrared Kinetic Photometery, Capable Of Measuring Esr And Hct , 20 Test Channels With Random Loading Pattern, Through Put : 40 Test / Hr, Esr Measuring Range: 0- 160 Mm / Hr And With Accuracy Of +1Mm ( Cv < 3% ) , Lcd Screen With Real Time Result Display On It, Internal Thermal Printer, Instrument Should Be Easy To Learn And Operate, Rs232 Ports Supporting His / Lis, Continuous Accessories Availability For A Considerable Time Of Minimum Five Years, Warranty At Least For A Period Of Three Years , After Sales Service Availability For Minimum Period Of Three Years, Installation And Training By Authorized Service Engineer Should Be European Ce / Usfda Approved Product Chinese Parential Make Not Allowed ) , Incubatorshould Be Branded 14’ X14” Stainless Steel , Microscope With Computer Branded , Fully Automated Urine Analyzerurometer Having Wide Screen Display And Thermal Printer, Urometer With Testing Availability Of 4 - 11 Urine Chemistry Parameters, With Average Testing Output Of Approx 100 Test Per Hour, Instrument Should Be Easy To Learn And Operate, Rs232 Ports For Communicating With Pc ( Bidirectional Interface ) And Barcode System, Having Usb Port For Keyboard Connectivity, Continuous Accessories Availability For A Considerable Time Of Minimum Five Years, Warranty At Least For A Period Of Three Years , After Sales Service Availability For Minimum Period Of Threeyear Should Be Iso, Ce, Approved Machine Chinese Parential Make Not Allowed , Refrigrator ( Lengh 636.4 To 645 Mm, Width 545-560 Mm, Height 1270 Mm – 1470 Mm Wight 40- 45 Kg Single Door, 5 Star Raiting )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Aug-2021 Corrigendum Technical Bid 09-08-2021
2 09-Aug-2021 Corrigendum In Technical Bid Technical Bid 12-08-2021
3 09-Aug-2021 Extension In Dates Date 12-08-2021

Key Value

Document Fees
INR 590 /-
EMD
INR 100000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail