}

2 Nos. Of 10 Kva Ups Purchase Of 2 Nos. Of 10 Kva Ups For Network Lab And Ccf Lab , 2 Nos.Of10kva Online Ups With 180 Mins Back Up , Capacity: 10 Kva True -Online Double Conversion Stand Alone Ups System, With Apfc Input Supply: 3 Phase + N 400 V ± 20%, Govt.Engineering college,Wayanad-Kerala

Directorate Of Technical Education-DTE has published 2 Nos. Of 10 Kva Ups Purchase Of 2 Nos. Of 10 Kva Ups For Network Lab And Ccf Lab , 2 Nos.Of10kva Online Ups With 180 Mins Back Up , Capacity: 10 Kva True -Online Double Conversion Stand Alone Ups System, With Apfc Input Supply: 3 Phase + N 400 V ± 20%. Submission Date for this Tender is 24-08-2021. UPS Tenders in Govt.Engineering college,Wayanad Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

28663517
2 Nos. Of 10 Kva Ups Purchase Of 2 Nos. Of 10 Kva Ups For Network Lab And Ccf Lab , 2 Nos.Of10kva Online Ups With 180 Mins Back Up , Capacity: 10 Kva True -Online Double Conversion Stand Alone Ups System, With Apfc Input Supply: 3 Phase + N 400 V ± 20%
Open Tender
Indian
Kerala
Govt.Engineering college,Wayanad
24-08-2021

Tender Details

2 Nos. Of 10 Kva Ups Purchase Of 2 Nos. Of 10 Kva Ups For Network Lab And Ccf Lab , 2 Nos.Of10kva Online Ups With 180 Mins Back Up , Capacity: 10 Kva True -Online Double Conversion Stand Alone Ups System, With Apfc Input Supply: 3 Phase + N 400 V ± 20% ( -40% @ 70% Of Nominal Load ) Input Power Factor & Harmonic Correction: ( 1 ) Power Factor = 0.99, Using Active Power Factor Correction System. Thdi Less Than 2.5 %, Using, Active Harmonic Conditioners. ( Offer Shall Contain Printed Manual Of The Model Showing The Above Parameter. If Not, Offer Will Not Be Considered ) Rated Output Power: 10 Kva / 9Kw ( Without De-Rating ) Output Supply: 1P + N: 230V ± 1% ( Configurable:208 / 220 / 230 / 240Frequency 50 / 60Hz ± 2 ( Upto ± 5 With Generator - Selectable Crest Factor Rating: 3: 1 Or Better Overall Efficiency ( Normal Mode ) Bypass Mode: Upto 95% For Ups Efficiency & Eco Mode 98%. =98% At Rated Load ( Offer Shall Contain Printed Manual Of The Model Showing The Above Parameter. If Not, Offer Will Not Be Considered ) Detailed Specifications And Others Entered In Nit Documents For Referance.

Key Value

Document Fees
INR 1770 /-
EMD
INR 10000.0 /-
Tender Value
INR 10 Lakhs /-

BOQ Items

Name of Work: PURCHASE OF 2 NOS. OF 5 KVA ONLINE UPS
Sl. No. Item Description
12 Nos.of10KVA ONLINE UPS WITH 180 MINS BACK UP
2Capacity: 10 kVA True -Online Double Conversion Stand Alone UPS system, with APFC Input supply: 3 Phase + N 400 V ± 20% (-40% @ 70% of Nominal Load) Input Power factor & harmonic Correction: (1) Power factor = 0.99, using active power factor correction system. THDI less than 2.5 %, using, active harmonic conditioners. (Offer shall contain printed manual of the model showing the above parameter. If not, offer will not be considered)Rated Output Power: 10 kVA /9KW (without de-rating) Output supply: 1P + N: 230V ± 1% (Configurable:208/220/230/240Frequency 50/60Hz ± 2 (upto ± 5 with generator - selectable Crest factor rating: 3: 1 or Better Overall efficiency (normal mode) Bypass mode: UPTO 95% FOR UPS EFFICIENCY & ECO MODE 98%. =98% at rated load (offer shall contain printed manual of the model showing the above parameter. If not, offer will not be considered) detailed specifications and others entered in NIT Documents for referance.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail