Repair / Replacement Of Summer / Winter Appliances Old Unserviceable Wiring And Connected Items At Vikram Vihar Anuj Vihar Shankar Vihar And Tarapore Enclave Under Age E / M ( S ) Of Ge ( South ) Delhi Cantt-10 Repair / Replacement Of Summer / Win, Garrison Engineer South Delhi Cantt 110010-Delhi

Military Engineer Services-MES has published Repair / Replacement Of Summer / Winter Appliances Old Unserviceable Wiring And Connected Items At Vikram Vihar Anuj Vihar Shankar Vihar And Tarapore Enclave Under Age E / M ( S ) Of Ge ( South ) Delhi Cantt-10 Repair / Replacement Of Summer / Win. Submission Date for this Tender is 30-08-2021. Electrification Work Tenders in Garrison Engineer South Delhi Cantt 110010 Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

28659843
Corrigendum : Repair / Replacement Of Summer / Winter Appliances Old Unserviceable Wiring And Connected Items At Vikram Vihar Anuj Vihar Shankar Vihar And Tarapore Enclave Under Age E / M ( S ) Of Ge ( South ) Delhi Cantt-10 Repair / Replacement Of Summer / Win
Open Tender
Indian
Delhi
Garrison Engineer South Delhi Cantt 110010
30-08-2021

Tender Details

Repair / Replacement Of Summer / Winter Appliances Old Unserviceable Wiring And Connected Items At Vikram Vihar Anuj Vihar Shankar Vihar And Tarapore Enclave Under Age E / M ( S ) Of Ge ( South ) Delhi Cantt-10 Repair / Replacement Of Summer / Winter Appliances Old Unserviceable Wiring And Connected Items At Vikram Vihar Anuj Vihar Shankar Vihar And Tarapore Enclave Under Age E / M ( S ) Of Ge ( South ) Delhi Cantt-10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-08-2021
2 26-Aug-2021 Corrigendum01 Date 30-08-2021
3 27-Aug-2021 Corrigendum 02 Other 30-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 93800.0 /-
Tender Value
INR 46.90 Lakhs /-

BOQ Items

NAME OF WORK: REPAIR/ REPLACEMENT OF SUMMER/ WINTER APPLIANCES, OLD UNSERVICEABLE WIRING AND CONNECTED ITEMS AT VIKRAM VIHAR, ANUJ VIHAR, SHANKAR VIHAR AND TARAPORE ENCLAVE UNDER AGE E/M (S) OF GE (SOUTH) DELHI CANTT-10.
Sl. No. Item Description
1Taking down carefully the old U/S Aluminium / Copper point wiring (light, fan, socket or power) including fitting and fixtures (switch, socket, bell push, lamp holder, electric bell, ceiling rose, fan regulator) and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as specified and directed by Engineer-in-charge.
2M&L for point wiring complete, standard copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in and including concealed PVC conduit medium gradeand sunk in new pressed steel terminal boxes of required sizefactory made and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 Sqmm standard copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified and directed by Engineer-in-charge. Note:- The rate is inclusive cutting /chasing and making good the disturbed surface with cm 1:3 and same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash complete.
3All as per item No 2 but here-in-before One 3 pin socket outlet, 5/6 Amps, independent board.
4All as per item No 2 but here-in-before 5 Amp socket outlet on same board.
5All as Item No 2 but here-in-before for one socket outlet 5/15 Amps on Independent board with cables 2.5 sqmm size for phase and neutral and 2.5 Sqmm for earthing with through existing concealed PVC/MS conduit. Note:- New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
6All as Item No 2 but here-in-before for one One light controlled by 2-way switches using cable of 1.5 Sq mm for phase and neutral and 1.5 sqmm for earthingwith through existing concealed PVC/MS conduit. Note:- New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
7S&F switch piano flush type 5/6 Amps SP one way complete all as specified and directed by Engineer-in-Charge.
8S&F switch piano flush type 5/6 Amps SP two way complete all as specified and directed by Engineer-in-Charge.
9S&F bell push, flush type 5/6 Amps complete all as specified and directed by Engineer-in-Charge.
10S&F socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and directed by Engineer-in-Charge.
11S&F switch piano 15/16 Amps SP one way complete all as specified and directed by Engineer-in-Charge.
12S&F universal socket outlet 2-in-1 (multipurpose) 5pin 6/16 Amps flush mounted type complete all as specified and directed by Engineer-in-Charge.
13S&F 0-4 step type electronic fan regulators for ceiling fan 1200/1400 mm sweep, 240V complete all as specified and directed by Engineer-in-Charge.
14S&F lamp holder Angle/Batten Type bakelite insulated body with back plate suitable for batten fitting complete all as specified and directed by Engineer-in-Charge.
15S&F in replacement, Decorative wall light mounting suitable for LED lamp upto 15 Watt with all connections complete all as specified and directed by Engineer-in-charge. Make:- Havells Cat Part No. LHF0ECE1TZ10014/ Halonix Cat Part HLWB-01-B22/ Philips model-Comet.
16S&F electric bell (Buzzer) any type complete with including fliexble wirein complete all as specified and directed by Engineer-in-Charge.
17S&F electric bell ding dong any type complete with including fliexble wirein complete all as specified and directed by Engineer-in-Charge.
18S&F ceilingrose surface Bakelite 65x25 mm two to three terminalscomplete all as specified and directed by Engineer-in-Charge.
19S&F wall mounted LED Integrated batten T5 20Watt -4ft white , 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 36/40Watt FTL fitting any type, complete all as specified and directed by Engineer-in-Charge.
20S&F wall mounted LED Integrated batten T5 10Watt -2ft white , 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 18/14 watt FTL fitting any type, complete all as specified and directed by Engineer-in-Charge.
21S&F surface mounting Round/ Square shaped LED downlighter 6 Watt any typecomplete with including newfliexble wireas required on site including taking down of old unsv existing ceiling light fitting any type complete all as specified and directed by Engineer-in-Charge.
22S&F LED 10 watt white Bulk head any type including newfliexble wireas required on site including taking down of old unsv existing light fitting of any type complete all as specified and directed by Engr-in-charge.
23S&F in replacement of VTPN distribution board 4 way double door, for fixing MCCB up to 250 Amps asincommer andMCBs as out goings with metel door andIP 43 Protections complete all as specified and directed by Engineer-in-Charge. (Make: Cat No. 5077 47 of legrand or its equivalent as L&T/Havells/Indoasian/ Siemens)
24S&F in replacement of VTPN distribution board 8 way double door for fixing MCCB up to 250 Amps asincommer andMCBs as out goings with metel door andIP 43 Protectionscomplete all as specified and directed by Engineer-in-Charge. (Make : Cat No. 5077 47 of legrand or its equivalent as L&T/Havells/ Indoasian/Siemens)
25S&F in replacement ofMCCB 3 Pole 415V, "C" series 250 Amps with breaking capacity 36 KA including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engineer-in-Charge.
26S&F in replacement ofMCCB 3 Pole 415V, "C" series 160 Amps with breaking capacity 36 KA including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engineer-in-Charge.
27S&F in replacement MCB TP 63 Amps 415 volts, "C" Series 10 KA as per site requirement complete as per site requirement complete all as specified and directed by Engineer-in-Charge.
28S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-8 Way, 240V with 200 Amp rated busbar complete as per site requirement complete all as specified and directed by Engineer-in-Charge.
29S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-12 Way, 240V with 200 Amp rated busbar complete as per site requirement complete all as specified and directed by Engineer-in-Charge.
30S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-16 Way, 240V with 200 Amp rated busbar complete as per site requirement complete all as specified and directed by Engineer-in-Charge.
31S&F in replacement ofMCB SPN 63 Amps 240 volts, "C" Series with breaking capacity 10 KA including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engineer-in-Charge.
32S&F in replacement ofMCB SPN 40 Amps 240 volts, "C" Series with breaking capacity 10 KA including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engineer-in-Charge.
33S&F in replacement MCB SP 63 AMPs C curve complete all as specified and directed by Engineer-in-Charge.
34S&F in replacement MCB SP 40 AMPs C curve complete all as specified and directed by Engineer-in-Charge.
35S&F in replacement MCB SP 6 to 32 AMPs C curve complete all as specified and directed by Engineer-in-Charge.
36S&F in replacement Sheet metal enclouser with metal cladplug & socketandMCB SP 20Amps, 240 V complete all as specified and directed by Engineer-in-Charge. Make - Legrand / Havell"s / C&S
37M&L "in replacement" submain wiringPVC insulated FRLS single core with stranded copper cable of size 10 Sqmm in 2 runs and 10 Sqmm one run for earthdrawing through existing PVC conduit 25 mm dia complete all as specified and directed by Engineer-in-charge. Note:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
38M&L "in replacement" submain wiringPVC insulated FRLS single core with stranded copper cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earthdrawing through existing PVC conduit 25 mm dia complete all as specified and directed by Engineer-in-charge. Note:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
39Taking down old Submain wiring any type , keeping away from site and M&L for submain wiringPVC insulated FRLS single core with stranded copper cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earthdrawing through existing PVC/MS concealed conduit complete all as specified and directed by Engineer-in-Charge. Note:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
40M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to GI wire 4 mm as earthing lead by means of nut, bolts and check nuts and washers, GI light grade protection pipe 15 mm dia upto 7.5 M, GI watering pipe 20 mm dia medium grade, RCC cover with funnel, excavation in any type of soil, PCC pit charcoal, salt all as shown in electrical plate No 5 of SSR Part I, including earth test point upto panel board including testing on completion complete all as specified and directed by Engineer-in-Charge.
41Taking down of ceiling fan/ exhaust fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation with required cable and testing complete all as specified and directed by Engr-in-charge Note:- Rewinding will be measured and paid under respective item of this Schedule.
42M&L for Rewinding of ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush and Shaftwhere ever required complete all as specified and directed by Engr-in-charge.
43M&L for Rewinding of Exhaust Fan upto 300/450 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush & shaft where ever required complete all as specified and directed by Engr-in-charge
44S&F in replacement ceiling fan/ Exhaust fanBall bearing of suitable size & model (as per sample) complete all as specified and directed by Engineer-in-Charge. Make:- NBC/ SKF
45S&F in replacement of fan condenser 2.5 Mfd complete all as specified and directed by Engineer-in-Charge. Make :- Epcos/Tibcon/Havells
46S&F in replacement of fan condenser 3.15 Mfd complete all as specified and directed by Engineer in Charge. Make :- Epcos/Tibcon/Havells
47M&L for replacement of exhaust fan blades for size upto 450 mm sweep as per sample complete all as specified and directed by Engineer-in-Charge.
48M&L for replacement of MS louvers suitable for exhaust fan of sizeupto 450 mm sweep as per sample complete all as specified and directed by Engineer-in-Charge.
49S&Fin replacement of holder hook with rubber washer suitable for size 1200/1400 mm ceiling fan as per sample complete all as specified and directed by Engineer-in-Charge.
50S&F PVC canopy for ceiling fan of size 1200/1400 mm as per sample complete all as specified and directed by Engineer-in-Charge.
51Taking down geyser 25/35/50 ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank , themrostate pipe, base plate assembly carrying out minor repairs including replacement of gaskets testing and refixing in position and making electrical and water connection complete all as specified and directed by Engr-in-charge
52S&F in replacement heating element 1.5 KW for any make of geyser of 25/35 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge. Make:- Micronking/Theeta/Standard
53S&F in replacement heating element 2 KW for any make of geyser of 50 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge. Make:- Micronking/Theeta/Standard
54S&F in replacement thermostat ( 9/11 inch Long) for 25/35/50 ltrs capacity geysers complete all as specified and directed by Engineer-in-Charge. Make Micronking/Theeta/ Standard
55S&F in replacement indicating lamp round / flat type as required for geyser 25/35/ 50 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge.
56S&F in replacement safety valve ISI marked for geyser 25/35/50 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge.
57S&F in replacement safety plug for geyser 25/35/50 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge.
58S&F in replacement PVC connection with brass nipple 15 mm x 450 mm long with 2 Nos brass/ CP nuts and washer for hot water for geyser 25/35/50 ltrs capacity as per sample complete all as specified and directed by Engineer-in-Charge.
59S&F in replacement of geyser syphon assembly set complete with inlet, outlet and thermostat including rubber gasket for geyser of 25 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge.
60S&F in replacement base plate of geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket of geyser 35 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge.
61S&F in replacement base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket of geyser 50 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge.
62S&F in replacement inner stainless steel tank suitable for 25 Ltr storage water heater complete all as specified and directed by Engineer-in-Charge.
63S&F in replacement inner stainless steel tank suitable for 35 / 50 Ltr storage water heater complete all as specified and directed by Engineer-in-Charge.
64S&F in replacement FR PVC Sheathed Round , Copper conductor (Flexible) industrial cable , 1100 Volts , conforming to IS: 694 of size 2.5 Sqmm 3 core for connecting geyser ,complete all as specified and directed by Engineer-in-Charge.
65S&F in replacement Rubber gasket for Water heater storage type of any capacity as per the existing, complete all as specified and directed by Engineer-in-Charge.
66S&F in replacement MS fastner bolt 8 mm dia and upto 150mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and directed by Engineer-in-Charge.
67S&F in replacement of Metal Clad Socket 240 Volts , 20 Amps, 2P + E, upto 20 Amps capacity of Ovory or blue cap colour complete all as specified and directed by Engineer-in-Charge.
68S&F in replacement of Metal Clad Plug Top 240 Volts , 20 Amps, 2P + E, upto 20 Amps capacity of Ovory or Grey colour complete all as specified and directed by Engineer-in-Charge.
69S&F in replacement of Solar Flat Plate Collector of 300 LPD of 2.0 mm thick with heat Exchangerall as per site requirement Inter solar/Racold or equivalent complete all as specified and directed by Engineer-in-Charge.
70S&F in replacement of Hot water storage tank with heat exchanger type with low carbon steel having Epoxy enamel coated tank. Thickness 1.6mm with 50mm CFC free PUF insulation, covered of pre coated steel duly insulated of solar water heating system, connection, testing and commissioningas reqd of 300 LPD capacity complete all as specified and directed by Engineer-in-Charge. Make : Inter solar/Racold or equivalent
71S&F in replacement for Makeup tank of Heat Exchanger of Hot Solar water of capacity 300 LPD all as per site requirement complete all as specified and directed by Engineer-in-Charge.
72M&Lfor De-Scaling of Solar Flat Plate Collector by Chemical process upto capacity 300 LPD complete to clear the deposits of temperory hardness in sides of collector tubes including brazing of leaking joint all as per site requirement complete all as specified and directed by Engineer-in-Charge.
73Taking up and down 20mm bore steel water tubing including connections complete all as specified and directed by Engineer-in-Charge.
74Fixing only 20 mm bore steel water tubing medium gradewith all fittings and fixed complete to wall and ceiling or laid in floor comlete all as specified & direted by Engr-in-Charge.
75Taking up and down 25 mm bore steel water tubing including connections complete all as specified and directed by Engineer-in-Charge.
76Fixing only 25 mm bore steel water tubing medium gradewith all fittings and fixed complete to wall and ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge.
77S&F GI tube 20 mm bore medium grade with all fittings (such as bend, elbows, tee, short pieces, connectors, cap, plug and union etc) and fixed complete to wall and ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge.
78S&F GI tube 25 mm bore medium grade with all fittings (such as bend, elbows, tee, short pieces, connectors, cap, plug and union etc) and fixed complete to wall and ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge.
79S&F Hose pipe 25mmdia with adjustable clamp/nut/bolts etc laid intrenches fixed to wall, ceilings and floor for hot water complete all as specified and directed by Engineer-in-Charge.
80S&F in replacement for SS-304 Nuts and bolts 6 x 25 mm sizeall as per site requirement complete all as specified and directed by Engineer-in-Charge.
81S&F in replacement for Dead plug of Collector as per site requirement complete all as specified and directed by Engineer-in-Charge.
82S&F in replacement forGaskets of Collector as per site requirement complete all as specified and directed by Engineer-in-Charge.
83S&F in replacement for Washers of Collectoras per site requirement complete all as specified and directed by Engineer-in-Charge.
84S&F in replacement ofAir Release Valve of Hot solar water of capacity 300 LPD as per site requirement complete all as specified and directed by Engineer-in-Charge.
85S&F in replacement ofBall valve of Size20mm (NB) Bronze all as per site requirement complete all as specified and directed by Engineer-in-Charge.
86S&F in replacement ofBall valve of Size25mm (NB) Bronze all as per site requirement complete all as specified and directed by Engineer-in-Charge.
87S&F in replacement of building security light 45W LED 5000K new Powder coated pressure die cast aluminium compact LED Street light suitable for pole dia 40 mm of bracket duly fixed with clamps, nut, bolts & washers etc complete all as specified and directed by Engineer-in-Charge. (Make: Halonix HL-R or its equivalent Bajaj/CG/Havells/C&S)
88M&L for Gas welding (TIG/Argon Welding) for leakage Joint of Hot water storage tank of capacity 300 LPD / Flat plate collector as per site requirement complete all as specified and directed by Engineer-in-Charge.
89Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.