Repair Maintenance Of Lt Oh Lines Panels Switch Gears Like Apfc Panels And Ug Cable Including All Connected Works Under Age Em Ii Of Ge Nw Vasco Repair Maintenance Of Lt Oh Lines Panels Switch Gears Like Apfc Panels And Ug Cable Including All Connecte, CWE NAVY VASCO-Goa

Military Engineer Services-MES has published Repair Maintenance Of Lt Oh Lines Panels Switch Gears Like Apfc Panels And Ug Cable Including All Connected Works Under Age Em Ii Of Ge Nw Vasco Repair Maintenance Of Lt Oh Lines Panels Switch Gears Like Apfc Panels And Ug Cable Including All Connecte. Submission Date for this Tender is 31-08-2021. Switch Gear Tenders in CWE NAVY VASCO Goa. Bidders can get complete Tender details and download the document.




Tender Notice

28659623
Corrigendum : Repair Maintenance Of Lt Oh Lines Panels Switch Gears Like Apfc Panels And Ug Cable Including All Connected Works Under Age Em Ii Of Ge Nw Vasco Repair Maintenance Of Lt Oh Lines Panels Switch Gears Like Apfc Panels And Ug Cable Including All Connecte
Open Tender
Indian
Goa
CWE NAVY VASCO
31-08-2021

Tender Details

Repair Maintenance Of Lt Oh Lines Panels Switch Gears Like Apfc Panels And Ug Cable Including All Connected Works Under Age Em Ii Of Ge Nw Vasco Repair Maintenance Of Lt Oh Lines Panels Switch Gears Like Apfc Panels And Ug Cable Including All Connected Works Under Age Em Ii Of Ge Nw Vasco

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Aug-2021 DATECORRI Date 24-08-2021
2 16-Aug-2021 OTHERCORRI Other 24-08-2021
3 24-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 44000.0 /-
Tender Value
INR 22 Lakhs /-

BOQ Items

NAME OF WORK:REPAIR / MAINTENANCE OF LT OH LINES, PANELS, SWITCH GEARS LIKE APFC PANELS & UG CABLE INCLUDING ALL CONNECTED WORKSUNDER AGE EM-II OF GE (NW) VASCO
Sl. No. Item Description
1Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep in soft/disintegrated rock getting out and levelling of bottom surface to required level all as specified and as directed.
2Removing surplus excavated material of rock from site to a distance not exc 50m away and depositing where directed not exc 1.5m from the starting point all as specified and as directed.
3Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick all as specified and as directed.
4M & L for LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade 120 Sq mm, 3½ core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) completeincluding taking down old unserviceable cable all as specified and as directed.
5All as per item No 4 here in before, but of size 185 sqmm all as specified and as directed.
6All as per item No 4 here in before, but of size 240 sqmm all as specified and as directed.
7All as per item No 4 here in before, but of size 95 sqmm all as specified and as directed.
8All as per item No 4 here in before, but of size 70 sqmm all as specified and as directed.
9Supply and fixing of DWC pipe IS-14930, size inner dia 50mm, outer dia 63 mm for cable protection in wall /under ground for laying of UG Cables all as specified and as directed.
10Supply and fixing of DWC pipe IS-14930, size inner dia 80 mm, outer dia 100 mm for cable protection in wall /under ground for laying of UG Cables all as specified and as directed.
11S & F in repairs LT Control panel board, indoor type,double door, floor mounted, overall size not less than 1500 x 1200 x 500 mm,having independent compartment for bus bar, incoming feeder and each outgoing feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheetsuitable for 3 Phase, 4 wire,415 volts 50 Hz, AC supply, bus bar chamber with copper bus bar of 800 Amp rating for 3 phase and neutral4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Setincluding necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar ofGI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coatingin siemens grey colour and provision for the following incoming and outgoing accessories all as approved andcomprising as under : -
12Incoming :- a)Provision for MCCB 4 Pole,400 Amp415V - 01 No. c) Digital Volt meter 0 - 500V, size 96 x 96 mm square type with selector switch - 01 Set d) Digital Amp Meter 0 - 400 Amp, size 96x96 mm square type with selector switch - 01 Set. e) Copper wound with CTR 400/5 - 01 set. f) Indicator Lamps (LED type) showing R,Y, B phase - 01 set. Outgoing :- a)Provision for MCCB 4 Pole,250 Amp415V - 02 Nos. b)Provision for MCCB 4 Pole, 200 Amp415V - 03 Nos. c)Provision for MCCB 4 Pole, 160 Amp415V - 01 No. d) M & L for necessary fixing arrangements by drilling and provision of foundation bolts in the existing floor complete - 01 job
13S & F in repairsLT Control panel board, indoor type, double door, floor mounted, overall size not less than 1500 x 1500 x 750 mm, having independent compartment for bus bar, incoming feeder and each outgoing feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheetsuitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with copper bus bar of800 Amp rating for 3 phase and neutral4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Setincluding necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar ofGI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coatingin siemens grey colour and provision for the following incoming and outgoing accessories all as approved andcomprising as under :
14Incoming :- a)Provision for MCCB 4 Pole, 400 Amp415V - 01 No. b) Digital Volt meter 0 - 500V, size 96 x 96 mm square type with selector switch- 01 Set c) Digital Amp Meter 0 - 400 Amp, size 96x96 mm square type with selector switch - 01 Set. d) Copper wound with CTR 400/5 - 01 set. e) Indicator Lamps (LED type) showing R,Y, B phase - 01 set. Outgoing :- a)Provision for MCCB 4 Pole,200 Amp415V - 02 Nos. b)Provision for MCCB 4 Pole, 160 Amp415V - 02 Nos. c)Provision for MCCB 4 Pole, 100/63 Amp415V - 04 Nos. d)Provision for MCB 4 Pole, 32 Amp415V - 02 Nos. e) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legsand made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No. f) M & L for necessary grouting as required PCC 1:3:6 using 40 mm graded stone aggregate, Type C2 for foundation of angle iron legs frame work complete - 01 job
15Note for item Nos 11 & 12 : - (a) New MCCBs/ Change over switches are measured and paid seperately under relevent item of this schedule. (b) Rate for Interconnecting copper control cable along with necessary copper lugs are inclusive in the quoted rates. (c)The dimension of panel given in the schedule are approximate size only. The contractor should obtain necessary approval / layout /general arrangement for panel form Engg in Charge prior to commencement of work. (d)Cost for connecting of existing old UG cable of any size / type to new incoming / outgoing terminals by cutting to the required length, addn/altn and provision of necessary cable lugs, cable glands, nut, bolt and washers, etc., shall be included in the quoted rates.
16M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm in substation yard for laying all as directed and as specified.
17M & L for LT heat shrinkable cable Jointing kit suitable for 3.5 core 70 to 150 Sqmm aluminium cable all as directed and as specified.
18M & L for LT heat shrinkable cable Jointing kit suitable for 3.5 core 185 to 300 Sqmm aluminium cable all as directed and as specified.
19M & L for removing vegetation, grass, scrubs and bushes or any small tree branches growing in Sub station yard along with fencing, around the pole, under the HT / LT transmission lines, yards or any description by manually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning shall be measured and paid separately.
20M & L for Cutting and trimming of tree branches 3 m all around of any size obstructing lumination of street light and touching LT / HT Over head line and stay wire including removing trimmed tree branches all as directed and as specified.
21S & F in repairs MCCB 4 Pole, current rating 630 Amp, adjustable over load and short circuit with Microprocessor release setting , breaking capacity 36 kA at 415V, 50Hz, including necessary spreaders / cable lugs / nut, bolt and washers if required all as directed and as specified.
22All as per item No 18 here in before, but for 4 pole 400 A, having breaking capacity 36 kA.
23All as per item No 18 here in before, but for 4 pole 250 A, having breaking capacity 36 kA.
24All as per item No 18 here in before, but for 4 pole 200 A, having breaking capacity 36 kA.
25All as per item No 18 here in before, but for 4 pole 160 A, having breaking capacity 36 kA.
26All as per item No 18 here in before, but for 4 pole 100 /125 A, having breaking capacity 36 kA.
27All as per item No 18 here in before, but for 4 pole 63 A, having breaking capacity 36 kA.
28Material and labour for re filling of distilled water with electrolyte suitable for lead acid battery of different capacities all as directed and as specified.
29S & F in repairs of lead acid battery 12 Volt 180 AH all as directed and as specified.
30S & F copper bus bar of any size with necessary provision of hole with fixing of new nut, bolt and washers of existing size in the panel board for any addition / alteration all as directed and as specified.
31S & F in repairs Aluminium bus bar of any size with necessary provision of hole with fixing of new nut, bolt and washers of existing size in the panel board all as directed and as specified.
32S & F in repairs MCB TPN 63Amps, 415 V all as directed and as specified.
33S & F in repairs MCB TPN 32 amps 415 volts C series all as directed and as specified.
34S & F in repairs MCB DP 32 Amps 240 volts C seriesall as directed and as specified.
35S & F in repairs MCB SP "C" series 10 Amps, 230V all as directed and as specified.
36M & L for PCC 1:3:6 using 40 mm graded stone aggregate, Type C2 for foundation of garden lightsincluding frame work where required all as directed and as specified.
37Supply and fix in repairs cable junction boxes IP 66/69 protected “halogen free and weather proof” suitable for outdoor type ( with metric knockouts for cable entry) of size 155 x 210 x 92mm including necessary suitable size new backelite connecting terminals mounted on saddles suitable for 3 phase with neutral system - 04 Nos of suitable length and thickness and connecting the incoming & out going LT cable connections in the terminal block of junction box and fixing clamps made up of GI flat of size 32 x 6 mm of suitable length-02 Sets, including GI nut and bolt and washers on poles complete all as directed and as specified.
38M & L for Earthing complete with galvanised steel earth plate, electrode,600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to GI strip 32x 6 mm thick dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 5 of SSR Part-I Connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chamber be 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover , watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe medium grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and as directed including demolish existing earth pit taking out old materials. Note : GI earth wire upto 7.5 RM is included in the unit rate quoted.
39S & F in repairs Galvanised iron strip 32 x 6 mm buried in ground / fixed on walls / ceilings by using suitable size GI saddles etc including taking out old one all as directed and as specified.
40Supply and fix or laying in trenches / on wall / poles / structures in repairs GItubing light grade for road crossing for cable protection of the following sizes including necessary suitable size MS flat fixing clamps, fixing screws complete all as directed and as specified.
41(a)50 mm dia
42(b)40 mm dia
43Taking down carefully ACSR of any size from OH Lines (running on 9/11 poles) after unbinding from insulators for replacement of multijointed / undersize conductors. all as directed and as specified.
44Restringing and restretching aluminium conductor reterived under item above including necessary bindingwith insulators using alunimium binding wire, connections of incoming and out going cables complete all as specified and as directed.
45M&L for ACSR conductor of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables complete all as specified and as directed.
46Restretching aluminium conductor or GI wire on existing over head lines (running on 9/11 Mtrs pole) without removing including unbinding from insulator and rebinding to insulator using aluninium binding wire , connections of incoming and out going cables, binding with spacers where required, complete all as directed and as specified. Note ;- For measurement length of each conductor shall be taken seperately
47Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use complete all as specified and as directed.
48Fixing only cross arm with cross arm supports/ angle iron induct frame etc incl nut, bolt, washer, welding, bending, hot or cold drilling holes for insulators bolts in any size or shape all as directed and as specified.
49Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as directed and as specified.
50Dismantling and taking old/UNSV stay assembly including Stay wire and loop type insulator complete all as directed and as specified.
51M&L for stay assy complete with MS stay plate of size 300x300x6mm thick, stay rod 20 mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I or directed by Engineer-in-charge. Note : Excavation, PCC, saty wire and loop type insulators shall be measured and paid separately.
52M&L for repair and replacement of galvanized stay strand of size 7/4 mm complete all as specified and as directed.
53M&L in replacement of loop type insulator large size with overall dimensions (90 x140) mm with clearance of hole 25.5 mm vitreous white brown or green all as directed and as specified.
54Dismantling insulators of any type, any size all as directed and as specified.
55Fixing of Serviceable shackle type insulator retrieved against SI itemNo 49 above of 100mm high, 115mm dia porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified, required at site and as directed.
56Fixing of Serviceable pin type insulator retrieved against SI item No 49above ofPin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and onegalvanisedironnutall as directed and as specified.
57S&F for Pin type polymer insulator including one galvanised mild steel spindle two GI washers and one GI iron nut 150mm height, 150mm dia for 11 KV gradeall as directed and as specified.
58M&L for HT 11 KVDisc type insulator with hardware, single disc assembly, polymeric insulator, vitreous145mm high and 255 mm dia and socket type, all as directed and as specified.
59Supply and fix in repair aluminum strip 25x3.15mm as roof conductor or down conductor or along the pole/pipe complete with saddles/ insulators made out of porcelain or fiber and fixing screws all as required at site and asdirected.
Disclaimer :