Certain Misc Repairs In Small Units Storm Water Drainage In Phasei And Certain Day To Day Repair To Internal Electrification With Rewinding Overhauling Of Fans Under Ge Narangi. Certain Misc Repairs In Small Units Storm Water Drainage In Phasei And C, GE NARANGI-Assam

Military Engineer Services-MES has published Certain Misc Repairs In Small Units Storm Water Drainage In Phasei And Certain Day To Day Repair To Internal Electrification With Rewinding Overhauling Of Fans Under Ge Narangi. Certain Misc Repairs In Small Units Storm Water Drainage In Phasei And C. Submission Date for this Tender is 23-08-2021. Electrical Maintenance Tenders in GE NARANGI Assam. Bidders can get complete Tender details and download the document.




Tender Notice

28647422
Corrigendum : Certain Misc Repairs In Small Units Storm Water Drainage In Phasei And Certain Day To Day Repair To Internal Electrification With Rewinding Overhauling Of Fans Under Ge Narangi. Certain Misc Repairs In Small Units Storm Water Drainage In Phasei And C
Open Tender
Indian
Assam
GE NARANGI
23-08-2021

Tender Details

Certain Misc Repairs In Small Units Storm Water Drainage In Phasei And Certain Day To Day Repair To Internal Electrification With Rewinding Overhauling Of Fans Under Ge Narangi. Certain Misc Repairs In Small Units Storm Water Drainage In Phasei And Certain Day To Day Repair To Internal Electrification With Rewinding Overhauling Of Fans Under Ge Narangi.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Jul-2021 BOQ BOQ 16-08-2021
2 06-Aug-2021 Other Other 16-08-2021
3 16-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work : CERTAIN MISC REPAIRS IN SMALL UNITS, STORM WATER DRAINAGE IN PHASE-I AND CERTAIN DAY TO DAY REPAIR TOINTERNAL ELECTRIFICATION WITH REWINDING/OVERHAULING OFFANSUNDER GE NARANGI.
Sl. No. Item Description
1SCHEDULE "A" PART-I
2Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed.
3S&F 6 mm thick asbestos cement corrugatedor semi corrugated sheetwith side lap, fixed with "L" or "J" type or cranked hook bolts, nuts & washers etc.complete all as specified and as directed.
4Refixing only asbestos cement corrugated or semi corrugated sheet as obtained from dismantling of old sheets with side lap, fixed with "L" or "J" type or cranked hook bolts, nuts and washers complete all as specified and as directed.
5S&F 6 mm thick asbestos cement two piece adjustable serrated ridge, corrugated or semi corrugatedsheetfixed with "L" or "J" type or cranked hook bolts, nuts & washers complete all as specified and directed.
6Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., completeall as specified and as directed.
7S&F 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugation side lap, fixed with "L" type or "J" type or cranked hook bolts and washers, in roof covering, walls cladding etc, with grade of zinc coating 275 complete all as specified and as directed.
8Refixing only galvanised corrugated mildsteel sheeting as obtained from dismantling of old sheets here in before with two corrugation side lap, fixed with & including "L" type or "J" type or cranked hook boltsin roof covering, wall cladding etc., complete all as specified and as directed.
9S&F 0.63 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed.
10M&L Pre- paintedhot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screwscomplete all as specified and as directed.
11M&L Pre- paintedhot dip aluminium Zinc alloy metalic coated plain steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws as specifiedcomplete all as specified and as directed. Note:To be executed for provision of ridges and hips.
12S&F in repairs, suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic)in & including a grid of GI system duly suspended with 4mmdia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid complete all as specified and as directed.
13S & F in repairs, Solid PVC Wall Lining consisting of 5 mm thick single side prelam wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all asspecified andas directed.
14S & F in repairs, 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame complete all asspecified anddirected.
15Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
16M & L for rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1998 grade St.-240 complete all as specified and as directed.
17S&F mild steelHand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 etc complete all as specified and as directed.
18M & L for preparation of new steel surface over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
19Demolition ofplain cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level)complete all as specified and as directed.
20M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
21M & L for PCC 1:3:6,type C2(using 40 mm graded stone aggregate) as in surface channel or drain including necessary form work complete all as specified and as directed.
22M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smoothwithout using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic jointfilling at every 3m length and at corners complete all as specified and as directed.
23M&L for 40mm thick PCC 1:2:4,type B1 (using 20mm graded stone aggregate) as in floor, finished the surface even and smooth with using extra cement complete all as specified and as directed.
24M & L for 100 mm thick PCC 1:2:4, type B2 (using 40 mm graded stone aggregates)as in path / paving / hard standing / floor and finished the surface even and smooth without using extra cement complete all as specified and asdirected.
25M & L for forming contraction (dummy) joints 65mm deep x10mm wide, filled with sealing compound Grade "A" complete all as specified and as directed.
26M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
27Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto complete all as specified and as directed.
28Demolition ofplain cement concrete of any description and in any position not otherwise specifically providedcomplete all as specified and as directed.
29M & L for PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in coping, cills, hold fasts, fixing of post, water trough etc. including necessary formwork (straight or curved) complete all as specified and as directed.
30Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for all as specified and as directed.
31M&L for Precast RCC 1:1.5:3, type A1 (using 20 mm gradedstone aggregate) as in cover slabwith plain fair faces including chamfers, weathering and setting in cement mortar 1:6 including form work complete all as specified and as directed. Note : Reinforcement will be measured and paid seperately.
32M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cutting, bending cranking, hooking end and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed
33M & L for mild steelTMT bars 8 mm dia cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed.
34Demolition of brick or stone masonry work built in cement mortarincluding all quoins, arches, pillars etc complete all as specified and as directed.
35M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
36All as per item No 34 here in before but except bricks. Note: Old serviceable bricks as obtained from demolitionhere-in-before shall be reused under this item complete all as specified and as directed.
37M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed.
38Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
39M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thickmixed with water proofing compound (@ 3% by weight of cement or as per manufacture"s instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note :Water proofing compoundwill be measured and paid separately as "Supply only".
40M&L for 15mm thick rendering in cement mortar (1:4),to fair faces of brick or concrete surfaces,finished the surfaceeven and fair complete all as specified and as directed.
41M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
42Supply only Integral water proofing compound ISI marked complete all as specified and as directed.
43M&L for water proofing treatment to RCC roof slab, including parapet comprising with the followingof treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish not exceeding 100 mtr distance from starting point. (ii) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 with mixing of WPC and surface finished fare and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum),weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall beapplied over bituminous primer as specified above overby torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying two coat of aluminium paint over theAPP modified membrane @ 0.11Kg/sqm.
44M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat ofprimer complete all as specified and as directed.
45M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed.
46Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm including builders hardware complete all as specified and as directed.
47Taking down chowkats or frames with shutters(without taking off shutters from the frame) area exceeding 1.5 Sqm but not exceeding 4 Sqm each including builders hardware complete all as specified and as directed.
48Taking down shutter of any descriptionarea n.exc 1 sqmeach including builders hardware complete all as specified and as directed.
49Taking down shutter of any descriptionarea exc 1 sqm but n exc 2 Sqm each including builders hardwarecomplete all as specified and as directed.
50M & L for 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinnedat joints complete all as specified and as directed.
51M&L formild steel flat iron in bands, straps, supports or stays for pintle hinge, hand made sliding bolts, hold fast etc conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
52S&F 30mm thick flush shutter, solid core construction with particle board core and plywood face panel, commercial type on both side complete all as specified and directed.
53S&F 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etcwith plain, chamfered or rounded, mitred beads (without sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (a) complete all as specified anddirected.
54S&F 30mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etcwith plain, chamfered or rounded, mitred beads (with sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (b) complete all as specified and directed.
55M&L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed.
56S & F anodized aluminium push pull type glazed door shutter single leafincluding necessary jointing cleats, glazing clips, rubber packing, snap beading, screws, handle, locking arrangement, 5 mm thick float glass tinted quality on both panels complete all as specified and as directed.(Refer Jindal Cat M-2016)Aluminium sections : "A" series (i) Shutter top, bottom & middle rails :- 85.00 mm x 44.45 mm x 1.40 mm thick (19600) (ii) Shutter vertical rail: 47.62 mm x 44.45 mm x 1.35 mm thick ( (iii) Frame top and sides :- 63.50 mm x 38.10 mm x 1.31 mm thick (20027) Note: Door closer shall be measured and paid separately
57S & F two track aluminium sliding window with approved make of following extruded section of anodised glazed shutter as per Standard Engineering practices including all other accessories complete like 5.00 mm thickglass panes, rubber beading, etc. complete all as specified and as directed.(Refer Jindal Cat M-2016) Aluminium sections : "A" series (i) Shutter bottom &top :- 43 x 14.7 x 1.2 mm thick (20688) (ii) Shutter interlock :- 37.50 x 20.5 x 1.5mm thick (20655) (iii) Shutter side (Handle) :- 43 x 14.7 x 1.2 mm thick (20688) (iv)Frame bottom:- 50.3 x 26 x 1.2 mm thick (20669) (v)Frame top and sides :- 50.3 x 26 x 1 mm thick (20670)
58S&F three track aluminium sliding window with approved make of following extruded section of anodised glazed shutter as per Standard Engineering practices including all other accessories complete like 5.00 mm thickglass panes, rubber beading, etc. complete all as specified and as directed.(Refer Jindal Cat M-2016 )Aluminium sections : "A" series (i) Shutter bottom &top :- 37.50 x 15 x 1.3 mm thick (20690) (ii) Shutter interlock :- 37.50 x 23 x 1.3 mm thick (20689) (iii) Shutter side (Handle) :- 37.50 x 23 x 1.3 mm thick (20689) (iv) Frame bottom:- 75 x 26 x 1 mm thick (20671)(v)Frame top and sides :- 75 x 26 x 1 mm thick (20672)
59S&F in repairs, Aluminium chequered grill with aluminium anodized of diamond shape with 6 mm dia section and mesh of size 75 x 75 mm in aluminium "Y" channel and aluminium flat 25 mm wide fixed with aluminium screws complete all as specified and as directed.
60S & F 100 mm size stainless steel butt hinges, complete all as specified and as directed.
61S & F 75 mm size stainless steel butt hinges, complete all as specified and as directed.
62S & F 200 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed.
63S & F 150 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed.
64S & F 150 mm extruded aluminum alloy handles, fabricated type, anodized complete all as specified and as directed
65S & F 100 mm extruded aluminum alloy handles, fabricated type, anodized complete all as specified and as directed
66S & F 300 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionor cast aluminum alloy complete all as specified and as directed.
67S & F in repairs, aluminium door closer (Diecast) bodyhydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and complete all as specified and as directed.
68S & F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
69S & F in repair, floor door stopper of aluminium alloy body and tongue, overall length of cover plate 140 mm anodised with hard drawn steel spring, fixed in floors complete all as specified and as directed.
70S & F stain less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
71S & F in repairs 25mm to 30mm dia stainless steel tubular curtain rod fancy type including brackets, stops, rollers etc complete all as specified and as directed.
72S & F in repairs, 25mm dia anodised aluminium tubular curtain rod including brackets,stops, rollerscomplete all as specified and as directed.
73Hacking out old broken glass of any thickness, size quality or description from wooden frames glazed with putty or fixed with bead complete all as directed.
74S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding0.50sqm ineach pane complete all as specified and directed.
75S & F 4 mm thick figured glass, pin head type and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed.
76S & F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane complete all as specified and as directed.
77Dismantling floor, hearth and wall tiling including cement mortar bedding (but excluding backing), removing rubbish off the premises complete all as directed.
78M & L for coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
79M & L for vitrified ceramic tiles, light shade, 10mm thick (square/rectangular) area of each tile notexceeding 0.36 sqm, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
80M & L for vitrified ceramic tiles, light shade, 10mm thick (square/rectangular) area of each tile notexceeding 0.36 sqm, in skriting dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
81M&L for glazed light coloured/printed ceramic tiles 300x200x7mm/350x250x7mm/450x350x7mm thick in vertical surfaces such as skirting, dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match colour of tiles, over and including 10 mm thickrenderingincement mortar 1:4 complete all as specified and as directed.
82S & F 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismantling of old Granite of any description complete all as specified and as directed.
83M&L for pre polished chequered cement concrete tiles in floor, area exc 0.06 Sqm but not exc 0.11 Sqm, 25 mm thick with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with colour pigment to match with the tiles over and including screed bed of 20 mm thick cement mortar (1:4) including dismantling of old tiles of any description complete all as specified and as directed.
84S & F in repair 60 mm thick machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006M-35 Grade over and including 30 mm thick sand bed complete all as specified and as directed.
85Taking up or down 15 mm bore GI water tubing and connections including cleaning for re-fixing to storecomplete all as specified and as directed.
86S & F GI tubing15 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
87Refixing only old serviceable15 mm bore Steel tubing and connections as obtained from taking up/down old steel tubingincluding provision of new fittingsin new or old position to walls,ceiling, flooring etc. complete all as specified and as directed.
88Taking up or down 20 mm bore GI water tubing and connections including cleaning for re-fixing to storecomplete all as specified and as directed.
89S & F GI tubing 20 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
90Refixing only old serviceable20 mm bore Steel tubing and connections as obtained from taking up/down old steel tubingincluding provision of new fittingsin new or old position to walls,ceiling, flooring etc. complete all as specified and as directed.
91M & L for Cutting chases, pinning in, making good to facing where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunsheds, shelves, lintel etc and cutting chases for concealed water tubing or concealed conduit wiring etc n. exc. 10 cm width or girth complete all as specified and as directed.
92S & F 500 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc including dismantling of old tank of any description complete all as specified and as directed.
93S & F 1000 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixedincluding dismantling of old tank of any description complete all as specified and as directed.
94S & F in repairs, 20mm bore, gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for union complete all as specified and directed.
95S&F in repairs, bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed.
96S&F in repairs, 15mm bore pillar taps, cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered "HOT" or "COLD" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed.
97S&F in repairs,stop valves/ angular stop valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directe.
98S&F in repair, 15mm bore dia stop valves cast copper alloy fancy type chromium plated with long shank and cup(conceled type) complete all as specified and as directed.
99S & F in repairs, 125 mm, dia chromium plated, swivel type shower rose with 190 mm long chromium plated shower arm and wall flange suitable for fixing 15 mm bore iron pipe complete all as specified and as directed.
100S&F in repair, tubular towel Rail of 20mm dia and 60cm in length, D shaped, with brass chromium platedbrackets complete all as specified and as directed.
101S & F in repairs, 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6mm thck AC board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.
102S&F in repairs, cabinet mirror rectangular shape 450 x 350 mm with selected quality mirror and PTMT frame with openable door shutter with PTMT frame outside mirror as framed complete all as specified and as directed. Make : Prayag, Cat No 557 or equivalent in Jaquar / ESS
103S & F in repairs, sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortat to dwarf wall or including fixing cantiliver brackets and connecting union to pipe overall size 914 mm x 460 mm x 203 mm bowl size 405 mm x 354 mm x 203 mm complete all as specified and as directed.
104S & F in repairs, 10 Litres capacity PVC valveless syphonic action type, flushing cistern, low level, white or coloured, with inlet, ball valve, float and handle including brackets etc complete all as specified and as directed.
105S & F in repairs, PVC connection pipe 15mm bore and450mm long with PVC PTMT nuts at each ends with rubber washers complete all as specified and directed.
106S & F in repairs, vitreous china, wash hand basin, white, flat back size 550 mm x 400 mm including brackets including pillar tap, 15 mm bore chromium plated, cast copper alloy with capstan heads, 32 mm waste coupling brass chromium platedsuitable for wash hand basins, with long screwed shanks and fly nuts andPVC waste pipe,15mm dia PVC connection pipe complete all as specified and as directed
107S & F in repairs, vitreous china wash down water closet (pedestal pattern) including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, trap set and including white or black seat cover for pedestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws etc complete all as specified and as directed
108S & F inrepairs, Vitreous China SquattingPan"Orissa pattern" size 580 mmx440 mm white with integral foot rest etc. ( excluding cistern and flush pipe) including S or P Trap and provision of concrete bedding and making good to floor complete all as specified and as directed.
109S&F in repairs, Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed.
110S&F in repairs, 110mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
111S&F in repairs, 75mm bore PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
112S&F in repairs, 75 mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
113S&F 110mm dia PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specifiec and as directed.
114S&F 75mm dia PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specifiec and as directed.
115S & F in repairs,110 mm bore PVC (SWR)vent cowl. complete all as specified and directed.
116S & F in repairs,stainless Steel Grating doom 110 mm dia complete all as specified and as directed.
117Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but includingswitches, ceiling roses, pendants, regulators, sockets, etc.and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
118M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLS cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
119Allas per item serial No 117 here-in-before butfor One light point controlled by 2- two way5 Amps switch
120Allas per item serial No 117here-in-before butfor One 3 pin 5 Amp switch socket outlet on independent board
121Allas per item serial No 117 here-in-before but for One 3 pin 5 Ampsocket outlet on same board with other switches.
122Allas per item serial No 117 here-in-before butfor One bell point controlled by one switch 5 Amps bell push.
123All as per item serial No 117 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
124M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLS cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC rigid conduit on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
125Allas per item serial No 123 here-in-before butfor One light point controlled by 2- two way5 Amps switch
126Allas per item serial No 123 here-in-before butfor One 3 pin 5 Amp switch socket outlet on independent board.
127Allas per item serial No 123 here-in-before butfor One 3 pin 5 Amp switch socket outlet on same board with other switches.
128Allas per item serial No 123 here-in-before butfor One bell point controlled by one switch 5 Amps bell push.
129All as per item serial No 123 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
130S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
131S&F in repairs, switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
132S&F in repairs, modular switch , flush type single pole one way 6 Amps 240 volt complete all as specified and as directed.
133S&F in repairs, switch piano, flush type single pole one way 15 Amps 230 volt complete all as specified and as directed.
134S&F in repairs, modular switch , flush type single pole one way 16 Amps 240 volt complete all as specified and as directed.
135S & F switch piano, flush type single pole two way 5 Amps 230 volt complete all as specified and as directed.
136S&F in repairs, switch piano, flush type single pole two way 5 Amps 230 volt complete all as specified and as directed.
137S&F bell push, flush type, 5 Amps complete all as specified and as directed.
138S&F in repairs, bell push, flush type, 5 Amps complete all as specified and as directed.
139S & F in repairs, modular Bell push 6 Amp 240 volts, flush typecomplete all as specified and as directed.
140S&F socket outlet 3 pin, 2-in-1, 5 Amps, flush typecomplete all as specified and as directed.
141S&F in repairs, socket outlet 3 pin, 2-in-1, 5 Amps, flush typecomplete all as specified and as directed.
142S&F in repairs, modular Socket outlet 2 in 1, 3 Pin 6 Amp flush type 240 volts complete all as specified and as directed.
143S&F in repairs, socket outlet 3 Pin 15 Amp 240 volts complete all as specified and as directed.
144S&F in repairs, modular Socket outlet 2 in 1, 3 Pin 6 Amp/16Amp flush type 240 volts complete all as specified and as directed.
145S & F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
146S&F in repairs, switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
147S & F switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
148S&F in repairs, switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
149S & F lamp holder, insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
150S&F in repairs, lamp holder, insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
151S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
152S&F in repairs, ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
153S & Fstepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
154S&F in repairs,stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
155S&F in repairs, modular stepped type electronic fan regulator, two module size, flush typecomplete all as specified and as directed.
156S & F call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed.
157S&F in repairs, call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed.
158S&F in repairs,white cover plate with frame ,1 module complete all as specified and as directed.
159S&F in repairs,white cover plate with frame ,3 module complete all as specified and as directed.
160S&F in repairs,white cover plate with frame ,4 module complete all as specified and as directed.
161S&F in repairs,white cover plate with frame ,6 module complete all as specified and as directed.
162S&F in repairs, modular metal flush box 3 module complete all as specified and as directed.
163S&F in repairs, modular metal flush box 4 module complete all as specified and as directed.
164S&F in repairs, modular metal flush box 6 module complete all as specified and as directed.
165Dressing of pre-wired casing caping /PVC conduit of One light /fan/ exhaust fan point controlled by one number one way 5 Amp switch by changing Casing caping /PVC conduit and necessary connecting items (such as flexiable conduit , screws etc) complete all as specified and directed.
166Taking out existing unserviceable switch board plates any type, dismantling switches carefully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 6 inch x 10 inch MS box with brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with1.5 sqmm single core copper multistranded cable complete all as specified and as directed. (Note :New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items).
167Allas per item No165 here-in-above but new 3mm thick masonite laminated sheet top cover white or ivory fixed on 4 inch x 8 inch MS box.
168Taking down carefully by unscrewing from board/outlet boxes, fitting and fixturessuch as switches, sockets,ceiling rose, lamp holders, brackets ceiling fitting ,bulkhead fitting, tube light fitting and regulator etc for reuse at site or carring to the store ( To be measured only when found in all respect complete for reuse) and making good disturbed surface of wall, flooretccomplete all as directed by Engineer-in-Charge.
169Refixing serviceable fittings/ fixtures as obtained from serial item no 167 here in before and connecting up with suitable size cableinlocation as directed by the Eng In charge .
170S&F in repairs, LED box type fitting of regal batten pre-wired including LED tube 1x20W ,fixed on PVC block connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cablecomplete all as specified and as directed. Make:- Havells Model-REGALBATTENT8UPTO1X22WDSBSWH +CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Philips /GE/Crompton
171S&F in repairs LED box type fitting pre-wired including LED tube 1x10W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable and fix on 2 no ofPVC blockcomplete all as directed. Make:- Jaguar Model-LGLZ01X010XC/ LGLZ01X010XN/LGLZ01X010XWor Make:- Havells Model-LUMILINEPLUSBS10WLED865SPCSS or equivalent model of make Philips /GE/Crompton
172S&F in repairs wall mounteddecorative luminaire in design mesh suitable for 9W LED lampB22 base ,including lamp15watt complete all as specified and as directed. Make -Havells, cat no-LHDL07150099 or equivalent in crompton, Bajaj, Jaquar
173S&F in repairs Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed. Make:- HavellsModel HEXAFT10WLED857SSYMBOPC or equivalent Model of make : Philips /Crompton /GE.
174S&F in repairsLED (double sided connection) ) ultra bright polycarbonate tube light 18/20 watt retrofit in existing flourescent tube light. Make Havells/crompton/Bajaj/Jaquar or euivalent.
175S&F in repairs LED building security luminaries 35 Watts energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device including testing on completion complete all as specified and as directed. Make: HavellsCAT No. ENDURACITYLITEPLATPLUSSL35WLED757SASYBOPC or equivalent of Philips/Wipro/CG
176M&L forGI bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 2.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed.
177S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 11 or equivalent model in Siemens / Schneider
178S & F in repairs, single pole & neutral DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 10 or equivalent model in Siemens / Schneider/L&T
179S & F in repairs, factory made, sheet steel distribution boards, TPN, 4 Way,protection class IP-43with min 100 Amp rating copper bus bar, provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed . Make :- Legrand Cat No 5076 70 or equivalent. model in Siemens / Schneider
180S&F in repairs,MCB TPN40 to 63Amps, 415V,50 HZ,C series breaking capacity 10KA complete all as specified and as directed. Make- Legrand ,cat part no-4086 81 to 83 equivalent model of make Siemens/Schnider.
181S&F in repairs, MCBs, SPN 6 to 32 Amps, 10 KA,"C" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4086 09 to 17 or equivalent model in Siemens / Schneider/L&T
182S&F in repairs, MCBs, SP 6 to 32 Amps, 10 KA, "C" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :-Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T
183Disconnecting the main power supply to distribution box and make a proper dressing of SPN/TPN/VTPN MCB/MCCB DBs ofpre-connected MCBsby changingscrew of DB cover ,earth wire and other necessary connecting items and dressing of wires with the help of cable tie inside the distribution box after completion supply power complete all as specified and directed.
184Dismantling old electric kWH meters carefully by disconnecting all electric connection and re-fixing after necessary repair of electric energy KWH meter single phase 05 to 60 Amps, including making connection of incomming and outgoing wiring circuits and submission of KWH reading details of old unserviceable taken down meter complete all as directed.
185Supply,installing,connecting and testing AC single phase static energy meter of Accuracy class 1.0, 240V,50Hz with backlit LCD display,of rating 10 to 60 Amp(Measure and displays in kWhV,I,kW,PF Last month history of kWh & Md in kW) with special features like TOD, Tamper logging,Optical communication port & display in absence of power with transparent hinge type box including taking dowm old meter and depositing the same in MES store yard of AGE E/M complete all as specified and directed. Make- HPL/L&T/SECURE .
186S & F in repairs, SMC Mild steel (Deep Drawn & Fabrication ) Polycarbonate meter box of suitable size accommodate 4 nos of three phase meter per box ,anticorrosive ,dust proof,rust proof ,shock proof self extinguishing property .resistance to heat,vermin & water proof ,ultra voilet stabilized and pilfer resistance including push fit locking system conforming to SMC materials ,IS: 14772 complete all as specified and as directed. Make -RMC/Sintex
187M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.)
188M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.)
189Taking down fan of any type/make and size of AC ceiling fan, carefully from fan hook,and transportingto MES E/M store yard,and refixing on same location or other locationcomplete all as specified and as directed.( Cost of repairing including replacement of spares if any will be measured and paiid seperatelyunder relevent items of this schedule.
190Strip opening of ceiling fan1200 /1400 mm sweep, cleaning thoroughly bush & ball bearing by petrol, washing/cleaning fan blades with caustic soda thoroughly, provision of fresh greasing, replacement of worn out/defective unserviceable parts (wherever necessary) reassembling the same and testing the fan on full load to entire satisfaction of Engineer-in-Charge. Note:- Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only.
191Cutting the existing copper winding of AC ceiling fan1200 mm//1400mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size includingprovision of twisted twin core flexible wire upto 0.7 metres long size 24/0, 020 (ISI marked) all insulating materials including varnishing, heating and drying complete includingsatisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
192Supply only condenser ISI marked 230/240/250 volts AC 2.5 Mfd suitable for ceiling fan. (Make : Usha/Asian/EPCOS/Universal).
193Supply only ball bearing of size 6201/6202 suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed. Make : NBC/SKF/SBBI
194Supply only rubber reels including shackle clamp, bolts, nuts, washers split pins of appropriate size as required complete all as specified and as directed.
195Supply only down rod 15mm dia GI pipe heavy duty 45 cm long including machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan complete all as specified and as directed.
196Supply only plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws complete all as specified and as directed.
197Taking down exhaust fan of size 200mm to 300mm sweep of any make and transporting from any locationto MES E/M store yard, and refixing on same location or other location carefully after repairing,washing by petrol ,greasing, replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same includingprovisionof twisted twin core flexible wire upto 0.7 meterslong size 24/0, 020 (ISI marked) and testing the fan on full load to entire satisfaction of Engineer-in-Chargecomplete all as specified and as directed. Note:- Cutting the existing copper winding, rewinding, Replacement of defective/ unserviceable parts if required shall be measured and paid separately under respective items .
198Cutting the existing copper winding of AC exhaust fan200mm to 300mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size includingprovision of twisted twin core flexible wire upto 0.7 mtrs long size 24/0, 020 (ISI marked) all insulating materials incl varnishing, heating and drying complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
199Supply only ball bearing suitable for exhaust fan 300 mm sweep complete all as specified and as directed.Make : NBC/SKF/SBBI
200Supply only condenser ISI marked 230/240/250 volts AC 4.0 Mfd suitable for exhaust Fans complete all as specified and as directed.(Make : Usha/Asian/EPCOS/Universal).
201M & L for painting of ceiling/exhaust fan complete with blades ,in situ with synthetic enamel paint Duco by spraying including filling cavities with filler ,ones coat after cleaning all dust etc.complete all as specified and as directed.
202S&F in repair telephonic wire used in home unit for smart meter ,4 wire RJ11 complete all as specified and as directed.
203S&F in repairs,ventilating fans AC single phase 230/ 240 V of size 250 mm sweep with louver shutter with frame and necessary fixing accessories , writing MES No. with black synthetic enamel paint2 cm high in letter complete with necessary connection upincluding provision of three core copper flexiblecable with flexible wire cover of plastic white in colourand connection from ceiling rose to exhaust fan terminaletc complete all as specified and as directed. Make-Usha, Model-CRISP AIR LX EXHAUST FAN or equivalent make in Crompton, Bajaj
204M&L for plate earthing completewith galvanizedmild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrodeat one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm boreGIpipe medium gradewith all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-Iincluding demolition of old earthing complete all as specified and directed.