| 1 | Labour for checking of split type air conditioner of capacity 1.0/1.5/2.0 TR to find out the defect and regular servicing of air conditioner unit (i.e) washing of air filter, cleaning of surface of indoor unit, flushing of drainage system,cleaning of coils and fins etc complete all as specified and directed.Note : Replacement of spare parts shall be measured and paid for seperately. |
| 2 | Labour for checking of Cassette type air conditioner of capacity 2.0/3.0 TR to find out the defect andregular servicing of air conditioner unit (i.e) washing of air filter, cleaning of surface of indoor unit, flushing of drainage system,cleaning of coils and fins etc complete all as specified and directed.Note : Replacement of spare parts shall be measured and paid for seperately. |
| 3 | Supply and fix remote control suitable for 1.5/2.0/3.0 ton capacity Split type/Cassette AC including testing and commissioning etc and taking down unserviceable item and taken as credit complete all as specified and directed. Make:Carrier/Hitachi/voltas/Blue star/llyod |
| 4 | Description all as per Sl item No 3.00 herein before but Copper Condenser coil and including servicing complete unit as per existing make and model |
| 5 | Description all as per Sl item No 3.00 herein before but condenser fan motor of suitable capacity and including servicing complete unit. Make Frogmaster/AUE |
| 6 | Description all as per Sl item No 3.00herein before but Indoor unit blower motorfor 1.5/2.0/3.0 ton capactiy.Make:Frog master/AUE |
| 7 | Description all as per Sl item No 3.00 herein before but Indoor unit swing motor or 1.5/2.0/3.0 ton capactiy and including servicing complete unit |
| 8 | Description all as per Sl item No 3.00 herein before but fan blade set. Make:Arvind or equivalent |
| 9 | Description all as per Sl item No 3.00 herein before but PVC drain pipe flexible type of suitable size and including servicing complete unit |
| 10 | Description all as per Sl item No 3.00 herein before but wiring kit complete as per existing make and model |
| 11 | Description all as per Sl item No 3.00 herein before but Dual capacitor 50+ 6 MFD .Make:Keltron/usha/upron |
| 12 | Description all as per Sl item No 3.00 herein before but thermostat.Make : Indfoss /Renutrol/Sriram |
| 13 | Description all as per Sl item No 3.00 herein before but Contactor relay.Make:AE/Keltron/indfoss |
| 14 | Description all as per Sl item No 3.00 herein before but air filter |
| 15 | Description all as per Sl item No 3.00 herein before but suction valve, |
| 16 | Description all as per Sl item No 3.00herein before but discharge valve |
| 17 | Description all as per Sl item No 3.00 herein before but Outdoor unit wall mount powder coated metal brackets with accessories. |
| 18 | Supply and fix Copper Cooling coil suitable for 1.5/2.0 ton capacity Split type including testing and commissioning etc and taking down unserviceable item and taken as credit complete all as specified and directed. |
| 19 | Supply and fix Copper Cooling coil suitable for 2.0/3.0 ton Cassette typeincluding testing and commissioning etc and taking down unserviceable item and taken as credit complete all as specified and directed. |
| 20 | Supply and fix copper pipe for Suction line of size 1/2\" or 5/8\" with insulation and sleeve for all Split/cassette AC of any capacity including dismantling the unserviceable pipe and taken as credit complete all as specified and directed. |
| 21 | Supply and fix copper pipe for Discharge line of size 1/4\" or 3/8\" insulation and sleeve for all Split/cassette AC of any capacity including dismantling the unserviceable pipe and taken as credit complete all as specified and directed. |
| 22 | Supply and fix three core flexible cord copper wire of size 4 Sqmm complete all as specified and directed.Make:Finolex/KEI/Anchor |
| 23 | Dismantlingunserviceable uncut hermitically sealed compressor from the split type AC unit and replaced with newhermitically sealed compressor forsplit typeAir conditioner 1.5 Ton capacityincludingtransporting and including servicing complete unit all as specified and as directed.Note :- (i)Compressor test reports along with warranty shall be provided for record. (ii) Gas charging shall be measured and paid for separately.Make:Carrier/Hitachi/voltas/Blue star/llyod |
| 24 | Dismantlingunserviceable uncut hermitically sealed compressor from the split type AC unit and replaced with new hermitically sealed compressor forsplit/cassette typeAir conditioner 2.0 Ton capacityincludingtransporting and including servicing complete unit all as specified and as directed.Note :- (i)Compressor test reports along with warranty shall be provided for record. (ii) Gas charging shall be measured and paid for separately.Make:Carrier/Hitachi/voltas/Blue star/llyod |
| 25 | Dismantlingunserviceable uncut hermitically sealed compressor from the Cassette type AC unit and replaced with new hermitically sealed compressor for cassetee typeAir conditioner 3.0 Ton capacityincludingtransporting and including servicing complete unit all as specified and as directed.Note :- (i)Compressor test reports along with warranty shall be provided for record. (ii) Gas charging shall be measured and paid for separately.Make:Carrier/Hitachi/voltas/Blue star/llyod |
| 26 | Supply and fix single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with single pole MCB 20 Amps,240 V including taking down old item and taken as credit complete all as specified and as directed. Make : Indo Asian/L&T/Siemen |
| 27 | Dismantlingunserviceable Outdoor unit from the split/cassette type unit and replaced with new outdoor unit (Includes compressor,condenser coil, condenser fan motor etc.) with suitable refrigerant gas support(R32/R410A/R22) of BEE 3 star rating 1.5 ton capactiy complete all as specified and directed.Note : (i)Gas charging shall be measured and paid separately.(ii) Company warranty certificate shall be produced by the contractor.Make:carrier/Hitachi/Voltas/Blue star/llyod/ O general/LG |
| 28 | Description all as per Sl item No 27.00 herein before but of 2.0 Ton capacity. Note : (i)Gas charging shall be measured and paid separately.(ii) Company warranty certificate shall be produced by the contractor Make:carrier/Hitachi/Voltas/Blue star/llyod/ O general/LG |
| 29 | Dismantling the unserviceable Indoor unit of the split type unit and replaced with new indoor unit(Includes evaporator coil, PCB etc.) with suitable refrigerant gas support(R32/R410A/R22) for split type AC BEE 3 star rating 1.5 ton capactiy complete all as specified and directed.Make:carrier/Hitachi/Voltas/Blue star/llyod/ O general/LGNote : (i)Gas charging shall be measured and paid separately.(ii) Company warranty certificate shall be produced by the contractor Make:carrier/Hitachi/Voltas/Blue star/llyod/ O general/LG |
| 30 | Description all as per Sl item No 29.00 herein before but of 2.0 Ton capacity. Note : (i)Gas charging shall be measured and paid separately.(ii) Company warranty certificate shall be produced by the contractor Make:carrier/Hitachi/Voltas/Blue star/llyod/ O general/LG |
| 31 | Material and labour for pressure testing the Split AC 1.50/2.00TR capacity, with nitrogen gas after flushing out the system free from refrigerant ,checking for leakages if any in the refrigerant system making good the leaking spots with necessary brazing/welding, ensuring leak proof system charging the refrigerant gas including replacing the strainer & capillary etc with new items and testing for satisfactory performance complete all as specified and as directed Note:Refrigerant gas charged shall be measured and paid separately under relevant item mentioned below. |
| 32 | Description all as per Sl item No 30.00 herein before but for cassette AC 2.0/3.0 TR capacity |
| 33 | Taking down existing worn out winding from fan motor , rewinding the fan motorof Split ACof capacity 1.5 TR/2.00 TR with super enamelled copper wire of suitable gauge capacity, bringing back to worksite and refixing the same on its position including replacement of bushes complete all as specified andas directed. |
| 34 | Taking down the PCB control box assembly and check for the fault on electronic components such as Integrated circuits,diodes,resistors,capacitors,transformer,indoor fan motor capacitor,sensors,buzzer,relay,indicators etc and replaced the worn out component with new items for Fixed speed/Non inverter type Split type AC of capacity 1.5 TR/2.00 TR , bringing back to worksite and refixing the same on its position complete all as specified andas directed. |
| 35 | Description all as per Sl item No 33.00 here in before but for Inverter type split type AC of 1.5 TR/2.0 TR capacity. |
| 36 | Description all as per Sl item No 33.00 here in before but for Cassette type AC of 2.0 TR/3.0 TR capacity. |
| 37 | Labour for water leak arrest of split type AC of any capacity by unblocking the clogged drain pipe by removing dirt and debris and make smooth flow of condensate drain water complete all as specified and directed. |
| 38 | Description all as per item no:36 here in before but for cassette AC of any capacity. |
| 39 | Supply only Refrigerant Gas R-22 complete all as specified and directed |
| 40 | Supply only Refrigerant Gas R-410A /R-32 complete all as specified and directed |
| 41 | Shifting of split type Air conditioner any capacity including fixing only powder coated metal bracket support suitable to mount out door unit (one pair per AC) and indoor unit duly making holes into the wall for insertion of copper pipe,drain pipe and 3 core cable,and making good the distrubed surfaces complete and including servicing complete unit all as specified and as directed. |
| 42 | Matrial and labour for Spray painting to the whole out door unit of split type air conditioner 1.5/2.0 Ton with two coats of synthetic enamel paint after cleaning the unit assemblyand including servicing the entire unit complete all as specified and directed. |
| 43 | Dismantlingtheunserviceable uncut hermitically sealed compressor from the water coolerunit and replaced with new re-conditionedhermitically sealed compressor for water cooler any make 40/ 80 ltrs capacity and including servicing complete unit all as specified and as directed. Note :(i)Gas charging shall be measured and paid separately.(ii) Company warranty certificate shall be produced by the contractor. Make:Carrier/Hitachi/voltas/Blue star/llyod |
| 44 | Supply and fix Starting relay for 40 to 150 Ltrs water cooler including dismantiling the old unserviceable one and including servicing complete unitall as specified and directed. Make:AE/Keltron/Indfoss |
| 45 | Description all as per Sl item No 44.00 herein before but over load protector and including servicing complete unit. Make:Renutral/Annapurna |
| 46 | Description all as per Sl item No 44.00 herein before but thermostat.Make : Keil/Tiplon |
| 47 | Description all as per Sl item No 44.00 herein before but Fan blade assembly suitable.Make:Arvind or equivalent |
| 48 | Description all as per Sl item No 44.00 herein before but wiring kit |
| 49 | Description all as per Sl item No 44.00 herein before but push lock Brass chromium plated of size 15 mm dia |
| 50 | Description all as per Sl item No 44.00 herein before but branded new fan motor with base 1/10HP .Make:Frog master/AUE |
| 51 | Description all as per Sl item No 44.00 herein before but top lid gasket for 80/120 Litre capacity water cooler |
| 52 | Description all as per Sl item No 44.00 herein before but drain stainless steel tray with drain elbow and connector |
| 53 | Description all as per Sl item No 44.00 herein before but Gate valve brass screwed both ends of size 15mm bore .Make:Leader/Zoloto |
| 54 | Description all as per Sl item No 44.00 herein before but Float valves brass with PVC ball complete suitable for 15mm bore ISI marked. Make:Leader |
| 55 | Description all as per Sl item No 44.00 herein before but PVC hose connection pipe both ends having brass coupling threaded for 15mm GI tube of standard length |
| 56 | Dismantlingtheunserviceable uncut hermitically sealed compressor from the Refrigerator unit and replaced with newhermitically sealed compressor for refrigerator any make 165 litre to 310 litre capacity and including servicing complete unit all as specified and directedNote : Gas charging shall be measured and paid separatelyMake:Carrier/Hitachi/voltas/Blue star/llyod |
| 57 | Supply and fixrelay for 165 to 310 Litres Refrigerator including dismantling the old unserviceable one complete all as specified and directed.Make : Indofoss/Ranutral/Annapurna |
| 58 | Description all as per Sl item No 57.00 herein before butover load protector 1/6 HP .Make:Whrilpool/ Kelvinator/Godrej |
| 59 | Description all as per Sl item No 57.00 herein before butbulb pin/screw type 10/15 W capacity.Make : Philips/Bajaj/CG |
| 60 | Description all as per Sl item No 57.00 herein before butthermosat defrosting type Make :Keil/Tiplon |
| 61 | Description all as per Sl item No 57.00 herein before butlight switch for refrigerator |
| 62 | Description all as per Sl item No 57.00 herein before but cooling coil |
| 63 | Description all as per Sl item No 57.00 herein before butcondensor coil |
| 64 | Description all as per Sl item No 57.00 herein before butfreezer door |
| 65 | Description all as per Sl item No 57.00 herein before but vegetable tray with glass. |
| 66 | Description all as per Sl item No 57.00 herein before but PVC ice tray. |
| 67 | Description all as per Sl item No 57.00 herein before but new frost freezer motor |
| 68 | Renewal of entire portion of base plate and legs ,welding with proper gauge new MS sheet complete all as directed and specified of refrigerators capacity 165 litres to 310 litres complete all as specified and directed. |
| 69 | Dismantlingtheunserviceable uncut hermitically sealed compressor from the deep freezer unit and replaced with factory re-conditionedhermitically sealed compressor for deep freezer any make up to 425 litres capacity complete all as specified and directedNote :Gas charging shallbe measured and paidseparatly.Make:Carrier/Hitachi/voltas/Blue star/llyod |
| 70 | Supply and fixrelay boxtype deep freezerincluding dismantling the old unserviceable items complete all as specified and directed. |
| 71 | Description all as per Sl item No 70.00 herein before butoverload protector 1/6HP. .Make:Whrilpool/ Kelvinator/Godrej |
| 72 | Description all as per Sl item No 70.00 herein before butdoor magnetic gasket. |
| 73 | Description all as per Sl item No 70.00 herein before butcondenser coil |
| 74 | Description all as per Sl item No 70.00 herein beforebutbrand new fan motor with base 1/10HP Make Frogmaster/AUE |
| 75 | Renewal of entire portion of base plate and legs ,welding with proper gauge new MS sheet complete all as directed and specified for deep freezer of capacity 500 litres complete all as specified and directed. |
| 76 | Taking outvoltage stablizer of any make and ofcapacity 5 KVA from site and transporting to servicecentre to detect /identify the nature of defects/repairs and reassembling after repair/servicing commissioning at site and testing to the entire satisfaction of Engineer-in-Chargecomplete all as specified and directed. |
| 77 | Description all as per Sl item No 76.00 herein before but of capactity 4 KVA. |
| 78 | Dismantling the burnt out transformer fromthe5 KVA capacitystablizer of any make and rewinding the same with supper enameled copper wire including provision of all materials and refixing into the stablizer and testingand testing complete all as specified and directed. |
| 79 | Description all as per Sl item No 78.00 herein before but of capactity 4 KVA. |
| 80 | Supply and fix relay set of two for voltage stabilizer up to 5 KVA capacity complete all as specified and directed. |
| 81 | Description all as per Sl item No 80.00 herein before but PCB (printed circuit board) |
| 82 | Note:The contractor should maintain/replace defective items with new one spares installed at site for the defect liablility period of two years for item nos:23 TO 25,27 to 30,43,56,69 and 78. |