| 1 | M&L Point wiringwith 1.5 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade drawn through and incl PVC rigid concealed conduit (ISI Marked) suitable size with allaccessories having thickness not less than 1.8mm incl sheet steel/ CI terminal box of adequate size having thickness not less than 2mm including 3mm thick hylem/masonite sheet including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor multistranded cable of green colour as earth conductor connected to common earth dolly complete all as specified and directed for one light / fan point controlled by one switch 5 Amp, SP, one way, 240 Volts.Note: 1. Connections of cable with MCBs/Switch Sockets shall be done through proper size copper/brass thimbles. 2. Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduitin not feasible.3. Proper colour code will be used for wiring as per the electrical rule and as directed. |
| 2 | S & F switch piano flush button single pole one way5 Amp AC 240 volts, all as specified and as directed. |
| 3 | M & L for ceiling rose, PVC/Polycarbonate, insulated body, surface Bakelite 65mm dia three terminals all as specified and as directed. |
| 4 | Supply and fixingof ceiling fanregulator electronicsocket type 5 stage speed variation ISI marked complete all as specifiedanddirected. |
| 5 | Supply, fixing, testing and connecting the BEE rated 5 star ceiling fan 230 volts, single phase of 1200 mm sweep double bearing type, copper winding, Air delivery 230 m3/min including down rod, canopy cover etc and connecting with flexible copper conductor of 1.50 sq mm 3 CORE and including writing of MES No with black enamelled paint complete all as spd and directed. |
| 6 | S&f of GI pipe 40mm medium grade along with ceiling fan hook clamped by nuts and bolts,fixing in both side of wall along the ceiling by providing hole for inserting GI pipe and plastering the same with matching the existing surface |
| 7 | M & L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable with in and including PVC concealed conduit heavy duty 20mm dia having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface tomatch with the existingsurface complete all as specified and directed.Note: (a) Insulation test of point wiring (b) colour coding is to bemaintained |
| 8 | S & F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed. |
| 9 | S & F socket outlet 2 in 1, 3 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed. |
| 10 | S&F Storage type Electric water heater (Geyser)capacity 25 litrsBEE 5 Star rating with complete accesoiries complete all as specified and directed. |
| 11 | S&F fancy type stop valves, cast copper alloy, screwed down, high pressure with crutcher butterfly handle, screwed both ends for 15mm bore dia of pipe complete all as specified and directed. |
| 12 | S& F fancy type Bib taps cast copper alloy, with crutch of butter fly handle, screwed for 15mm dia pipe complete all as specified and directed. |
| 13 | S&FGI pipe 15mm (1/2\") dia, medium Grade complete including fittings laid in floor, along with wall/ceiling etc complete all as specified and directed. |
| 14 | S&F PVC connection for hot & cold water 15mm dia 450 mm long with brass adaptors complete all as specified and directed. |
| 15 | M & L for providing/ cutting the round/ square hole of required size in wall finishing the same for distrubed surfaces complete all as spd and supply and fixingPlastic Ventillation fans, Single phase, 230 volts 300 mm sweep complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed. |
| 16 | S & F of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge. |
| 17 | S&F MCB SP 240V, 50Hz, 10 KA, \"B\" curve of rating 6 to 32 Amp all as specified and directed. |
| 18 | S&F MCB SPN 240V, 50Hz, 10 KA, \"B\" curve of rating 6-32 Amp all as specified and directed. |
| 19 | Design,Supply,Installation.testing and commissioning of 12 KW Solar off Grid Power Plant with 20 KVA Power conditioning unit (PSU) Single Phase 230V,Battery Bank of 240 V150 Ah Tubular LMLA Solar Battery, all fitting fixing,Mounting Structure and Chemical Earthing with Lighting Arrestor.(i) Solar modules(330Wp) 38 Nos with 25 Years warranty(ii) 16 KW/20 KVA 230 V AC Single Phase Power Conditioning Unit(Inverter) 01 Nos with two years warranty(iii) Battery Bank -Tubular LMLA 240 V 150 Ah C@10( 12 V 150 Ah x 20 nos ) with five years warranty(iv) DC Distribution Box-2 in 2 out (1 X 15Amp Fuses plus SPD Class II) with DC Switch 01 No with five years warranty(V) Chemical Earthing set of three 01 set and Lighting Arrestor 01 NoNote :- The Quoted rate deemed to be inclusive of PV modules,module mounting structures,inverters,batteries,monitoring devices and connected items |
| 20 | Note: (i)The Quoted rate deemed to be inclusive of PV modules, module mounting structures, inverters, batteries, monitoring devices and connected items.(ii)The make of solar panel and solar inverter shall be from same OEM and shall be indigenous & MNRE approved.Certificate for the same along with technical specification shall be produced before placing order.Makes of solar panel and inverter TATA/HAVELLS/PANASONIC/BOSH or equivalent approved makes of HQ CE/WC.(iii)Plant shall be installed and the roof of existing structure and equipment etc will be fixed on roof and in the rooms of existing structure any damage caused to the existing structure during the execution of work shall be made good by the contracvtor at his own cost to the entire satisfaction of Engr-n-Charge. |
| 21 | S& F SinglephaseElectronic Meter (LCD) Display Multy Function Type All as Specified and directed by Engineer In charge |
| 22 | S&F sub main wiringcomplete with two runs of 4 sqmmPVC insulatedunsheathed single core multistrand copper conductorcable of 1100 volts grade drawnthrough includingnon metalic rigid PVC conduit pipe alongwith accessories fixed on walls/floors/ceilingetcwith one run of 4 sqmm PVC insulatedunsheathed copperconductorcable of green colouras earth continuity conductor all as specified and directed by Engr-in-Charge. |
| 23 | M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.25 metre deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as showin in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust, common salt all around Earth plate upto 150 mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40 mm thick RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregrate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including test on completion. (Note :- The rate quoted include cost of min 7.5 metre earthing wire) |
| 24 | Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (NIL). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249)The performance security for an amount equivalent to 5% (Five percent) of the acceptedcontract sum shall be delivered by the successful bidder immediately after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249. |