Civil Work Of Ogp Room At Janana Hospital, Distt. Alwar 2 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides a, alwar-Rajasthan

Medical Health And Family Welfare has published Civil Work Of Ogp Room At Janana Hospital, Distt. Alwar 2 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides a. Submission Date for this Tender is 02-08-2021. Earth Moving Machinery Tenders in alwar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

28638001
Civil Work Of Ogp Room At Janana Hospital, Distt. Alwar 2 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides a
Open Tender
Indian
Rajasthan
alwar
02-08-2021

Tender Details

Civil Work Of Ogp Room At Janana Hospital, Distt. Alwar 2 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils. 3 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 4 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). 5 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 6 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix 7 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 8 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 9 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) 10 Random rubble dry stone Kharanja under floor. 11 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) 12 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick 13 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20 mm nominal size). 14 Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 15 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. 16 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work 17 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable) 18 Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 19 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 20 Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 25 mmx 25 mm x 2.1 mm 21 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.3.0mm thick (Wt. 5.0 Kg./Mtr. Sq.) 22 Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: 23 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint. Extra for double leaf shutters. 24 Part B : Electrical Work 25 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked medium duty PVC conduit & its accessories, round tiles,Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch,Modular plate with grid plate,screws,making connections, testing etc. as required.Gr 1 26 Short point (up to 3 mtr.) 27 Medium point (up to 6 mtr.) 28 Long point(up to 10 mtr.) 29 Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved makein surface / recessed ISI marked medium duty PVC conduit & its accessories, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal, 6 A modularswitch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required.Gr 1 30 On board 31 Supplying and fixing of power plug point Modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost ofmodular 16 amp. Switch and socket outlet, making connection , testing , etc. as required.Gr 1 32 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required.G1 33 2 x 2.5 sq. mm. + 1x1.5sqmm 34 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 35 P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar, conforming to IS13032 & IS8623 including making internal DBterminations with copper lugs , testing etc. as required.G1 36 Double door (single phase) 37 12 way 38 P&F 240/415 V MCB of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required.GROUP 1 39 Single pole MCB 40 6 A to 32 A rating 41 Double pole MCB 42 40-63 A 43 S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall and making good the same as required.GROUP 1 44 25 mm 45 P & F phenolic laminated sheet 2.0 mm thick of size 75 mm dia. Including screws, cup washer as required. 46 P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required 47 5 step fan regulator 2 ModuleGr 1 48 P & F 18 swgM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . 49 P&F of Heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaustfan,IS:2312 marked in existing opening including making connections testing etc. as required.GROUP 1 50 450 mm sweep(900/1400 RPM) 51 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd. 52 Up to 380 mm size 53 P & F of IP 20 LED tube light 20 watt with external batten made from CRCA sheet steel suitable to replace T-B/T-12 tube light, integral driver, 2000 luman + 5olo tolerarrce system luman efficiacy of 100 Lm/ watt minimum expected life time of 25000 burning hours, CCT 5700 I( ANSI, CRI 80, driver efficiency >850/o, Life expectancy of driver rnin 30000 hrs. PF 0,95 at full load/ 230 volt AC.Gr 1 54 P & F double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 1200 mm sweep Gr 1 55 P/Laying P.V.C. insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I of Group2of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.GROUP 1 (armoured) In existing RCC/HUME/STONEWARE PIPE 56 70.0 Sq,mm 57 3 core 58 S & Laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 59 8 SWG copper wire 60 25 mm Dia. 61 Supplying and drawing PVC/ Polythene insulated and PVC sheathed unarmoured/ armoured telephone cable with 0.5 mm dia. Tinned /annealed copper conductor taped &confirming to ITD specification S/WS -113C ofapproved make in existingsurface or recessed conduit/casing capping. 62 Unarmoured Telephone cable in existingsurface or recessed conduit/casing capping. 63 2 pair 64 P & F ISI markedflush type single line telephone jack including making connection testing etc. as required. 65 Supply , Drawing and Testing of 4 pair, 24 AWG UTP Cat 6 Cable as per latest ammendments of TIA /EIA 568 B.2-1 Specifications in existing MS/PVC Conduits including making connections to Information outlets and Patch Panels with ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing required 66 Supply and Installation of Information outlets made of high impact plastic body ABS FR Grade with spring loaded collapsible shutters in jack Recess, suitable for Cat 6 application complying to latest ammendments EIA/ TIA 568 B.2-1 Specifications in existing modular /MS Boxes along with necessory connections as required 67 Supply & fixing of Faceplate for Flush / SurfaceMount Information Outlets Single Aperture with screw hole covers & Icon Tree Size 86mmX86mm 68 Single Aperture

Key Value

Document Fees
INR 500 /-
EMD
Refer document
Tender Value
INR 9.70 Lakhs /-

BOQ Items

Name of Work: Civil work of OGP Room at Janana Hospital, Distt. Alwar
Sl. No. Item Description
1PART-A (CIVIL WORK)
2Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils.
3Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.
4Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand).
5Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
6Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
7Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc.
8Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc.
9Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)
10Random rubble dry stone Kharanja under floor.
11Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand)
12Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick
13Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20 mm nominal size).
14Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ).
15Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.
16Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work
17Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable)
18Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.
19Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
20Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 25 mmx 25 mm x 2.1 mm
21Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.3.0mm thick (Wt. 5.0 Kg./Mtr. Sq.)
22Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:
23Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint. Extra for double leaf shutters.
24Part "B" : Electrical Work
25Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked medium duty PVC conduit & it"s accessories, round tiles,Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch,Modular plate with grid plate,screws,making connections, testing etc. as required.Gr 1
26Short point (up to 3 mtr.)
27Medium point (up to 6 mtr.)
28Long point(up to 10 mtr.)
29Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved makein surface / recessed ISI marked medium duty PVC conduit & it"s accessories, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal, 6 A modularswitch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required.Gr 1
30On board
31Supplying and fixing of power plug point Modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost ofmodular 16 amp. Switch and socket outlet, making connection , testing , etc. as required.Gr 1
32Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required.G1
332 x 2.5 sq. mm. + 1x1.5sqmm
342 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
35P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar, conforming to IS13032 & IS8623 including making internal DBterminations with copper lugs , testing etc. as required.G1
36Double door (single phase)
3712 way
38P&F 240/415 V MCB of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required.GROUP 1
39Single pole MCB
406 A to 32 A rating
41Double pole MCB
4240-63 A
43S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall and making good the same as required.GROUP 1
4425 mm
45P & F phenolic laminated sheet 2.0 mm thick of size 75 mm dia. Including screws, cup washer as required.
46P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required
475 step fan regulator 2 ModuleGr 1
48P & F 18 swgM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side .
49P&F of Heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaustfan,IS:2312 marked in existing opening including making connections testing etc. as required.GROUP 1
50450 mm sweep(900/1400 RPM)
51P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.
52Up to 380 mm size
53P & F of IP 20 LED tube light 20 watt with external batten made from CRCA sheet steel suitable to replace T-B/T-12 tube light, integral driver, 2000 luman + 5olo tolerarrce system luman efficiacy of 100 Lm/ watt minimum expected life time of 25000 burning hours, CCT 5700 I( ANSI, CRI 80, driver efficiency >850/o, Life expectancy of driver rnin 30000 hrs. PF 0,95 at full load/ 230 volt AC.Gr 1
54P & F double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 1200 mm sweep Gr 1
55P/Laying P.V.C. insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I of Group2of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.GROUP 1 (armoured) In existing RCC/HUME/STONEWARE PIPE
5670.0 Sq,mm
573 core
58S & Laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.
598 SWG copper wire
6025 mm Dia.
61Supplying and drawing PVC/ Polythene insulated and PVC sheathed unarmoured/ armoured telephone cable with 0.5 mm dia. Tinned /annealed copper conductor taped &confirming to ITD specification S/WS -113C ofapproved make in existingsurface or recessed conduit/casing capping.
62Unarmoured Telephone cable in existingsurface or recessed conduit/casing capping.
632 pair
64P & F ISI markedflush type single line telephone jack including making connection testing etc. as required.
65Supply , Drawing and Testing of 4 pair, 24 AWG UTP Cat 6 Cable as per latest ammendments of TIA /EIA 568 B.2-1 Specifications in existing MS/PVC Conduits including making connections to Information outlets and Patch Panels with ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing required
66Supply and Installation of Information outlets made of high impact plastic body ABS FR Grade with spring loaded collapsible shutters in jack Recess, suitable for Cat 6 application complying to latest ammendments EIA/ TIA 568 B.2-1 Specifications in existing modular /MS Boxes along with necessory connections as required
67Supply & fixing of Faceplate for Flush / SurfaceMount Information Outlets Single Aperture with screw hole covers & Icon Tree Size 86mmX86mm
68Single Aperture
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail