Construction Of Dr. Rajendra Parsad Govt. Medical College At Tanda In Distt Kangra (Hp) (Sh-Providing And Fixing Bedhead Panel In Trauma Centre, Burn Unit And Pulmonary Unit.) Construction Of Dr. Rajendra Parsad Govt. Medical College At Tanda In Distt Kan
Tender Overview
Project Description
Construction Of Dr. Rajendra Parsad Govt. Medical College At Tanda In Distt Kangra (Hp) (Sh-Providing And Fixing Bedhead Panel In Trauma Centre, Burn Unit And Pulmonary Unit.) Construction Of Dr. Rajendra Parsad Govt. Medical College At Tanda In Distt Kangra (Hp) (Sh-Providing And Fixing Bedhead Panel In Trauma Centre, Burn Unit And Pulmonary Unit.)
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing wall Mounted imported medical Vertical Column with all relevant Hospital Technical Memoranda (HTM), Hospital Building Notes (HBN) and British Standards (BS)/Equivalent as well as ISO11197:2009. /Equivalent. It shall be CE marked/Equivalent with the notified body number specified provided with a copy of the certificate of origin constructed from extruded aluminium alloy 6063 T6, aluminium extrusions usedbe of approximate wall thickness not less than 3.5 mm. with antibacterial paint ensuring 100% shield against infectious agent. The lids shall be removable to allow access to the aluminium sections. Segregation shall be provided within the side sections to ensure that services are not accessible when removing the lids,supplied as a fully wired and tested module, compliance with EC CERTIFICATE/Equivalent / medical directive 93/42/EEC, equipment should be considered class II b. It should be IP 20 Classification according to the degree of protection against penetration of liquids and external agents, protection provided on external power circuit which provides adequate protection with circuit breakers or fuses dimensioned according to the power indicated on the label.Accessories must be provided with EACH vertical column (wall mounted)/Pendent as ) 1 No. Vertical pole made of stainless steel with support of aluminium and IV stand with 4 Hooks,6 nos. antibacterial 6/16amp sockets of Indian origin multipin. (Pre wired), 6 nos. ear thing bonding sockets, 2 Nos. RJ 45 Data sockets of Indian origin multipin., 2 monitor stand, Stainless steel Basket and illumination light (LED), 6 nos. Imported NFPA-99 PB type gas outlets points ( 2 oxygen, 2 Air 4 bar & 2 Vacuum) as per technical specifications 1 no. Imported Oxygen Flow Meter (0-15 l/pm) as per technical specifications attached, 1no. Imported Oxygen Flow Meter (0-70lpm) 1no. Imported Oxygen Flow Meter (0-70lpm) as per technical specifications attached, Humidifier Bottle 250cc Imported as per technical specifications attached, 2 Vacuum (Suction) Regulator with PB Adaptor as per technical specifications attached, 2 No Suction stainless steel adaptor/probe compatible with gas outlets connections complete set, 2 No Oxygen stainless steel adaptor/probe compatible with gas outlets connections complete set, 2 No Air 4 Bar stainless steel adaptor/probe compatible with gas outlets connections complete set,2 No Vacuum (Suction) connection jar (Polysulphone) 1000ml with lid, clamp and connecting rubber pipe Imported. ) 3nos. [IN TOTAL FOR ALL 28 WALL PENDENT THAT IS ONE EACH FOR ONE CABIN] Imported ISO VALVE - SINGLE PORT/LOCKING 3/4\" --> 22mm Ball Valve with Pipe line assembly (pre piped) as per technical specifications attached.Samples of mentioned life saving products should be submitted with tender bid or demonstration should be provided in Tanda within 24hours of intimation such as 1) Oxygen Flow Meter 0-15 lpm, 2] Oxygen flow meter0-70 lpm, 3) Polysulphone or Polyproplyene Humidifier Bottle, 4) Vacuum Regulator 0-1000m/bar, 5) Polysulphone 1000ml Vacuum Collection Jar, 6)Stainless Steel Probe/Adaptorfor PB Outl forall outlets, 7) Outlets of Oxygen/Vacuum/Air, LED light, monitor stand, 8) Electrical sockets/RJ 45 Socket and other all accessories. Bidder must submit chnical Compliance from original manufacturer for each line item with all certificates and data sheet, r must submit letter of authorization from original manufacturer for each line item. c) Bidder must submit copy of valid certificate of origin.Bidder must submit undertaking from the original manufacturer for after sales support and spares. Bidder must submit copy of valid UL Listed or ETL Listed or USFDA Certificate/Equivalent issued by notified body for gas outlet points and digital vacuum regulator and copy of valid CE certificate/Equivalent issued by notified body with 4 digit notified body number for oxygen flow meter and vertical wall mounted column (medical supply unit) completeIncluding 5 years maintenance along with Guaranty/warranty of materialas per direction of Engineer- Incharge, including carriage of materials within all leads, lifts and other incidentals. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender