Hindustan Prefab Limited has published Implementation Of Development Works At Shivrinarayan Implementation Of Development Works At Shivrinarayan, Distt. Janjgir-Champa Under Ram Van Gaman Path Project In Chhattisgarh. Submission Date for this Tender is 07-08-2021. Civil Work Tenders in Shivrinarayan, Distt. Janjgir-Champa Chhattisgarh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 02-Aug-2021 | Date Extension Corrigendum-I | Date | 07-08-2021 |
Sl. No. | Item Description |
1 | CIVIL WORKS |
2 | Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area). |
3 | Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.In all Type of Soil. |
4 | Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50M and lift upto 1.5M |
5 | Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete. |
6 | Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form wrok. 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 40 mmnominal size. |
7 | Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels,Foundations, footings, base of columns and plinth beam in any shape and size. |
8 | Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work. M-25 Grade |
9 | Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth |
10 | Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: Thermo-Mechanically treated bars |
11 | Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including formwork. |
12 | Extra for brick work in superstructure above plinth level for every floor or part therof in additional to rate for foundation and plinth: |
13 | 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m). |
14 | Providing and making 6mm thick cement plaster of mix: Slab area |
15 | Providing and making 12mm thick cement plaster of mix: in cement mortar 1:6(1 cement : 6 fine sand) |
16 | Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix In Cement Mortar 1:6 (1 cement : 6 fine sand) |
17 | Wall painting with acrylic premium emulsion (plastic) paint of required shade to give an even shade. On new work (Two or more coats |
18 | Wall painting with acrylic luxury emulsion (plastic) paint of Required Shade to give an even shade. On new work( two or more coats) |
19 | Applying one coat of cement primer on wall surface (applied @ 0.80litrs/10 sqm) complete. |
20 | Providing and applying 2mm thick ready mix exterior grade putty (Birla wall care, Alltek Superfine W/R of (NCL), J.K. wall putty) on walls to make the surface smooth and even. |
21 | Painting exterior surface with ATEXTURE exterior paints of required shades as per manufacture specification to give protective and decorative finish including cleaning washing of surface etc. complete with. on new work (two or more coats applied @ 3.28 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
22 | 25mm thick cement concrete flooring with 1:2:4 cement concrete (1 cement : 2 coarse sand:4 graded Stone aggragate 12.55 mm nominal size) finished with floating cost of neat cement |
23 | Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm Pigment Coloured (rubber mould) precast interlock concrete blocks |
24 | Dismantling rammed moorum and boulders or rammed moorum and silt in foundation or under floor including all lead and lifts. |
25 | Demolishing brick masonry including arches, stacking of serviceable material disposal of unserviceable material within 50 metres lead. In cement mortar. |
26 | Dismantling flag stone flooring laid in cement/lime mortar including stacking of serviceable material and disposal of unserviceable material within 50 metre lead. |
27 | Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material within 50 metre lead. |
28 | Demolishing cement concrete including disposal of material within 50metre lead. 1:3:6 or richer mix |
29 | Extra for cutting reinforcement bars in R.C.C. or R.B work. (Crosssectional area of RCC/RB work to be measured) |
30 | Trenching in ordinary soil upto a depth of 60cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly leveling with in a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). |
31 | Supplying and stacking sludge at site including royalty, loading, unloading and carriage upto 5 km (sludge measured in stacks will be reduced by 8% for payment). |
32 | Supplying and stacking at site well decayed cow dung manure from approved source, including loading, unloading and carriage upto 5 km (manure measured in stacks will be reduced by 8% for payment). |
33 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. |
34 | Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/ and good earth to be paid separately). |
35 | Grassing with ‘Doob’ grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed (the goodearth shall be paid for separately). In rows 7.5 cm apart in either direction. |
36 | Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). |
37 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 1.2 m dia and 1.2 m deep. each |
38 | Edging with modular well burnt clay bricks of crushing strength not less than 25kg/ sqcm laid dry length wise including excavation, refilling, consolidating with hand packing and spreading neatly surplus earth withina lead of 50 m : |
39 | Hedges like Alife, Dorenta, Tikoma etc |
40 | Furn like Arica, China etc (3 year old) |
41 | Providing and fixing sand cast iron S&S plain bend of required degree as per IS : 1729: 100 mm dia |
42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge 50 mm nominal outer dia pipes |
43 | Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
44 | Carrying out the resistivity survey by VES method using Schlumberger configuration for locating the proper spot for drilling of tube well within the selected habitation, including photography, interpretation of resistivity data and submission of report in the desired format along with resistivity readings, necessary graph and photographs. (only successful point is payable) : 1 pont |
45 | Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level.: 150 mm dia |
46 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 150 mm dia |
47 | Supplying, assembling, lowering and fixing in vertical position in bore well, ISI marked G.I. casing pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part-1&Part-2) 1992 with IVth revision (Up-to-date amendments), of reputed & approved make, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 150 mm nomial dia |
48 | Providing and fixing gunmetal single acting air release valve with screwed inlet 25 mm dia and with necessary G.I. coupling, valve to be fitted on top of Air vessel or on wet riser as per specification. |
49 | Providing& fixing butterfly valve with hand lever operationsuitable for working pressure of 15 Kg / Sqcm.Including rubber gasket, flanges, nuts, bolts, washers & painting complete as required. |
50 | Providing,fixing,jointingandtestinginposition the following heavy class G.I. pipes conformingto IS:1239. Including all necessary fittings such as bends, tees, union,reducers,flanges&plugs etc. Threading, flanged jointing, makingproper connections and 100mm thick fine sand around the pipes. Includingexcavation in all kind of soil upto required depth (minimum 0.6m depth), dewatering, refilling, watering, ramming & shifting of surplus excavated material by the contractor within the site limitasdirectedbythethesiteinchargeandmakinggoodthesame complete as required. 50 mm dia NB |
51 | Providing, Laying & fixing to wall, ceiling and floor, underground, HDPE pipes and fittings (PE-100) (10Kg/cm2 with working Pressure) of approvedqualitymakeAquaplast,open,concelled,includingjointing withbuttfusionwelding,withnecessary specials,elbow, equal& unequal tees, reducers, end cap, including all material andlabor, jointing and testing all Connectionetc., complete in all respectsof the following outer diameter(OD) size:90MM |
52 | Providing, Laying & fixing to wall, ceiling and floor, underground, HDPE pipes and fittings (PE-100) (10Kg/cm2 with working Pressure) of approvedqualitymakeAquaplast,open,concelled,includingjointing withbuttfusionwelding,withnecessary specials,elbow, equal& unequal tees, reducers, end cap, including all material andlabor, jointing and testing all Connectionetc., complete in all respectsof the following outer diameter(OD) size:90MM |
53 | Providing,installation,testingandcommissioningofdualplatenon- returnvalveoffollowingsizesconfirmingtoIS:5312completewith rubber gasket, GI bolts, nuts, washers etc. as required. 100 mm |
54 | Supply , installation of pump 3HP with panel & electrical cable |
55 | ELECTRICAL WORKS |
56 | WIRING IN CONCEALED PVC conduit Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point |
57 | WIRING IN CONCEALED PVC conduit Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5 )Medium Point |
58 | WIRING IN CONCEALED PVC conduit Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5 )Long Point |
59 | Extra for providing and fixing light plug point on board in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm)point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) |
60 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulatedcopper conductor, wire inconcealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 2.5 sq. mm in 20mm conduit |
61 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulatedcopper conductor, wire inconcealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 4 sq. mm in 25mm conduit |
62 | Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5/6 amps one way switch |
63 | Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 15/16 amps switch |
64 | Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 3 pin 5/6 amp socket outlet |
65 | Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 6 pin 15/16 amp socket outlet |
66 | Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Fan regulator Electronic, step type moving all round |
67 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification 100mmX75mm (3 Module) |
68 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification 200mmX75mm (6 Module) |
69 | Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm)along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5) 25 mm |
70 | Supplying and fixing on surface/ recess vertical type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, with 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland/ knock out plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door |
71 | Supplying and fixing SP MCB, 240 volts, "C" curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 6 amps to 32 amps |
72 | Supplying and fixing TP&N MCB, 440 volts, "C" curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 40 amps |
73 | Supplying and fixing TP&N MCB, 440 volts, "C" curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 63 amps |
74 | Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Seperate housing for driver etc complete as per specification and P.A. should be greater than 0.9. LED chip efficacy ratio = 120 lumens /watt. 30 watt |
75 | Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Seperate housing for driver etc complete as per specification and P.A. should be greater than 0.9. LED chip efficacy ratio = 120 lumens /watt. 50 watt |
76 | Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Seperate housing for driver etc complete as per specification and P.A. should be greater than 0.9. LED chip efficacy ratio = 120 lumens /watt. 200 watt |
77 | Supplying , installation , testing and commissioning of following type Recessed LED inground/pathway Lighting fixture with IP67 protected Die-Cast Aluminum housing and High purity Lenses for superior performance. LED shall having LM80 complied as per L70 standard LEDs minimum tested for 10,000 burning hours with 3000K CCT with minimum life cycle 50000 hrs burning hours at 50°C.Luminaire light should have secondary lenses. Driver shall be 3 stage Constant Current Constant Voltage with voltage range of 150-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60V DC. Driver Power factor shall be 0.95 and above and THD shall be less than 10%. 6 Watt |
78 | Supplying, installation, testing and commissioning of LED Neon Flex Strip220 V AC White /Warm White /Red /Blue /Pink / Yellow Coloured complete as per specification and IP65, P.F. should be greater than 0.75 |
79 | Supplying, installation, testing and commissioning of following LED Spike Light fitting complete withElectronic Driver Heat sink Capacitor and all other accessories, including connection, earthing etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio = 100 lumens /watt.IP-65 9watt |
80 | Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio = 120 lumens /watt. 60 watt |
81 | Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio = 120 lumens /watt. 90 watt |
82 | Supplying erection testing and commissioning of hot dipped galvanised (single dip 86 micron) 20 metre High mast pole on existing RCC foundation with all accessories and equipments, detailed as below to withstand wind pressure upto 180km/hr and minimum following specifications: a) HM shaft made of not more than 2 sections of suitable lengths with telescopic stressfit joints between sections without any circumpherencial welding, sheet thickness 4mm top and bottom sections, nominal dia 460mm on bottom and 150 mm on top, base plate 30mm thick 670mm dia, PCD of foundation bolts 650mm. b) Double drum winch for lowering & raising of lantern carriage on high mast with operatable with power tool/ manual handle attachment with a torque limiting device for safe locking of carriage. c) Raising/lowering type lantern carriage designed to carry specified nos of luminaries, control gear box, junction box. d) Top pulley assemble with weather proof cover. e) 3 Nos suitable length and size stainless steel wire ropes (minimum 6mm dia and 7/19 construction) for lowering & raising of lantern carriage. f) Suitable size and length multicore flexible copper power trailing cable (minimum 3 core 4 sqmm) g) Hinged service door in base section h) Base plate earthing terminal. i) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. j) Lightning conductor finial made of 25mm dia 300 mm long G.I. tube having single prong. k) Anchor plate of size 750x750x6mm, tem-plates 3mm thick, GI foundation bolts 12 Nos of 30 mm dia 850 mm long (EN 8 Grade) along with nuts washers etc. (RCC fooundation and luminaries will be paid separately) |
83 | Designing and providing suitable and approved size RCC foundation for 12-30 mere high mast including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as required including laying and fixing HM foundation bolts with tam plates but excluding the cost of foundation bolts with tam plates etc complete as per specification |
84 | Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. Upto 300 mm deep |
85 | Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 100 amp (20x5mm) |
86 | Providing and fixing metal clad, TP&N 4 pole automatic change over switch unit, 415/500 volts, including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. 250 amps |
87 | Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) Multi Function meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification. |
88 | Providing and fixing following Time switch (timer) in existing panel including connection, testing and commissioning as per specification. Astronomical type with year programmed |
89 | Supplying and fixing Low voltage (class -II) surge protection device (SPD) TP&N 440 volts, in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. |
90 | Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 3 pole MCCB, 320A, Adjustable Thermal - Magnetic Release, 35KA |
91 | Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 3 pole MCCB, 250A, Adjustable Thermal - Magnetic Release, 25KA |
92 | Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 3 pole MCCB, 25-100A, Adjustable Thermal Release, 18KA |
93 | Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 3 pole MCCB, 160A, Adjustable Thermal - Magnetic Release, 25KA |
94 | Supplying and fixing DP MCB, 240 volts, "C" curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 6 amps to 32 amps |
95 | Providing maintenance free earthing with following size GI pipeincluding making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: With 3 metre long GI Pipes and 50 kg back filling compound. |
96 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification. |
97 | Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification. |
98 | Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 3.5 x 150 sq. mm. |
99 | Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 3.5 x 300 sq. mm. |
100 | Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 4 x 10 sq. mm. |
101 | Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 4 x 16 sq. mm. |
102 | Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 4 x 25 sq. mm. |
103 | Supplying and laying following sizes one number FRLS PVC insulated, PVC sheathed, steel armoured, copper conductor control /power cable of 1.1 KV grade in exiting PVC/ GI pipe etc as per specification and IS: 694 (2010). 2 x 1.5 sq. mm |
104 | Supplying and laying following sizes one number FRLS PVC insulated, PVC sheathed, steel armoured, copper conductor control /power cable of 1.1 KV grade in exiting PVC/ GI pipe etc as per specification and IS: 694 (2010) .4 x 1.5 sq. Mm |
105 | Supplying and laying following sizes one number FRLS PVC insulated, PVC sheathed, steel armoured, copper conductor control /power cable of 1.1 KV grade in exiting PVC/ GI pipe etc as per specification and IS: 694 (2010) .6 x 1.5 sq. mm |
106 | Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 32 mm |
107 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 1 x 6 sq. mm |
108 | Supplying and laying HDPE pipe of 4kg/Sqcm in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 63 mm outer dia |
109 | Supplying and laying HDPE pipe of 4kg/Sqcm in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 110 mm outer dia |
110 | Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement ortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : |
111 | Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : |
112 | ABC Fire Extinguisher 2KG Nitrogen Store Pressure As per IS: 15683:2018 Body Sheet Not Less Then 2mm Thickness, CE Mark NRV Valve With ABC Powder 90% UL 299 FIRE RATING: 1A, 34B. With all accessories. |
113 | CO2 type Fire Extinguisher ISI marked confirming to IS:15683:2018 Capacity 4.5Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shall comply with IS 15222. FIRE RATING:- 55B. Complete with Hose Assembly and horn , locking arrangement, operation manual, bracket with two screw and sleeve |
114 | Supplying and drawing UTP 4 pair Cat 6 LAN wire in existing surface/ concealed Steel/FRLS PVC conduit as per specification |
115 | Supplying , installation , testing and commissioning of2 MP DOME Camera weather & dust proof IP based Fixed Lens day/night Camera (IP66) 2MegapixelCMOS Image Sensor,H.265 / H.264 triple-stream encoding ,WDR(120dB), Day/NightUL, CE, FCC Certified as per the specifications. |
116 | Supplying , installation , testing and commissioning of2 MP PTZ Camera of weather & dust proof IP based Dome PTZ (Pan Tilt & Zoom) true day& night camera ,1/2.8” 2MP PS CMOS Image sensor, Max. 50/60fps@1080P,Color: 0.005Lux@F1.6; 0Lux@F1.6 (IR on),Powerful 45x (3.95~177.7 mm) Optical and 16x Digital zoom, WDR(120dB), 3D DNR, Day/Night(ICR),Defog, ROI, EIS, AGC, BLC, HLC, Support Starlight Function, Up to 300 presets, auto scan, 8 tour, 5 pattern, auto pan, Tripwire, Intrusion, Abandoned/Missing , Face Detection, Heat Map,IR Range of 200 Mtr., Max 300° /s pan speed, 360° endless pan rotation,Built-in 7/2 alarm in/out,Micro SD card 256GB,IP67, IK10, Support PoE+,UL, CE ,FCCcertified as per the specifications. |
117 | Supplying , installation , testing and commissioningof 8 Channel NVR 2 Sata port Up to 16 channel IP camera input , Max 200Mbps incoming bandwidth ,Smart H.265+/H.265/Smart H.264+/H.264 dual codec decoding , Up to 8MP resolution preview and playback , Support 2 SATA HDDs up to 6 TB each,2 USB(1 USB3.0, 1 USB2.0) , 1 HDMI / 1 VGA simultaneous video output ,ONVIF Version 2.4 conformance , Alarm In / out4/2 , Two way talk 1 Channel Input, 1 Channel Output RCA ,1 RJ-45 port (10/100/1000Mbps) as per the specifications. |
118 | Supplying , installation , testing and commissioning of 16 Channel NVR 2 Sata port Up to 16 channel IP camera input , Max 200Mbps incoming bandwidth ,Smart H.265+/H.265/Smart H.264+/H.264 dual codec decoding , Up to 8MP resolution preview and playback , Support 2 SATA HDDs up to 6 TB each,2 USB(1 USB3.0, 1 USB2.0) , 1 HDMI / 1 VGA simultaneous video output ,ONVIF Version 2.4 conformance , Alarm In / out4/2 , Two way talk 1 Channel Input, 1 Channel Output RCA ,1 RJ-45 port (10/100/1000Mbps) as per the specifications. |
119 | Supplying , installation , testing and commissioning of2 TB Surveillance Hard disk drive Complete as required |
120 | Supplying , installation , testing and commissioning of8 Port Giga PoE Switch 10/100/1000 8 Port with 2 GigaJ 45uplink, PoE switch ,AI Extend , AI Vlan as per the specifications. |
121 | Supplying , installation , testing and commissioning of 6U IndoorRackWallmount 6U 450D With Front Glass Door Lock & Key 550 6U - loaded with cable manager + PDU + Fan complete as required. |
122 | Supplying, installation, testing and commissioing of following size LED Monitor, table/wall mount with inbuild speaker minimum 5Wx2,with minimum 1 No of HDMI and USBport including remote control, connecting cable, batteries, and all accessories, connection etc complete as per specification. 32 inch |
123 | Supply, installation and testing for HDMI cable. |
124 | Providing and supllying of SITC of Architecturalwall mounting / pole mounting Housing of the luminaire should be made of Synthetic, Metal with.Luminaire should be suitable for both wall mounting as well as pole mountingwith Filament lamp 6 W 3000K. (Philips-1738130PN or similar) PANEL |
125 | Fiber Components Supplying,installtion,testing & commsissioning of 6 Core OM3 Multimode Mode Fiber Armored (PC-0051, 06 FIBER SINGLE-MODE UNI-TUBE UNARMOURED OFC WITH 2 FRP HDPE) layed in 20 MM pipe in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe |
126 | Fiber Components Supplying,installtion,testing & commsissioning of OFC to cat 6 converter |
127 | Providing and plantingHeighted trees such as, Gulmohar, Badam, Neem etc. of minimum height required 3.5M in the digged pits including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: |
128 | 40-50mm thick Local Bilha/ Red Flag stone slab in riser of steps, skirting, dado and pillars laid on 12mm (Average) thick cement mortar 1:4 (1 cement : 4 coarse sand) and joint with grey cement slurry mixed with pigments to match the shade of the slab i/c grinding, rubbing and polishing, procured from Bilha querry Chhattisgarh, including chisling, shaping over 50mm cement-sand mortar with recess pointing with matching colour etc. |
129 | Supplying and fixing of FRP strips bench,PF 908 capacity-3 Adults, area 1.5MX0.61M, height 0.45M, Length 1.5M, Width 0.61M, Colour according to consultant requirement and departmental approval |
130 | Providing and fixing of fre-fabricated shop with adecorative elementry design as per specification of size 1500x3200x2500mm with a shop title and project logo provision and all electrical points in built as per drwaing A) Structure: - Structure ofpre-fabricated shop should be structurally tainless Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting,hoisting, fixing in position upto a height of 5m above baselevel, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer Including RAM GAMAN THEME.P/F HOLLOW TUBE 100 X 100X 5, TAKING TUBE WEIGHT = 14.70Kg/m And P/F HOLLOW TUBE 50 X 50 X 5, TAKING TUBE WEIGHT = 6.90Kg/mtake in base and colum B) Wall :- PUF PANEL dimensionhickness 50 mmUsage/Application WallPattern PlainMaterial PUFShape RectangularDensity 35-40 Kg/Sq mtrTensile Strength 3.7 kg/cm2Temperature -18 deg to +140 deg CAdhesion Strength 2.9 kg/cm2as per Drwaing and Engineer incharge C) Flooring: Base of the Modular Shopmade up of wooden frame and 18mm thick marine plywood.Flooring is of 120 x 12 Hard wood or Laminated wooden flooring. Whereas outdoor decking is 95 x 28 mm thermo treated decking as per Drwaing and Engineer incharge |
131 | Providing and Fixing of the information Pole made of Cast Iron Of height 3.2m fixed with a base plate of 8mm. Pole is made out of MS. Hollow circular pipe with a decorative moulds as per drawing mentioned with a bottom dia 300mm and top dia is 150 painted black with 2 coats of redoxide painthaving Two name boards back to back horizantally placed and fined facing with Radium letters ( IN HINDI AND ENGLISH) make 3M with fine art |
132 | Providing and fixing of the cantilever road signage pole made of cast iron of height 8.5 m fixed with a base plate of 8 mm over a RCC pedestal ,pole is made out of ms hollow circular pipe with a decorative moulde as per drawing mentioned with a dia 600 mm with 2 coat of redoxide paint having one name board at top cenatileaver with decorative cast iron jali with logo and CNC cit cast iron map wirh radium film over it vertically welded to the pole and fined facing with radium lettr ( In Hindi and English) |
133 | Providing and fixing of the welcome gate for 4 lane road made of cast iron of height 10.15 m fixed with a base plate of 8 mm over a RCC pedestal ,pole is made out of ms hollow circular pipe with a decorative moulde as per drawing mentioned with a dia 600 mm with 2 coat of redoxide paint having one name board at top cenatileaver with decorative cast iron jali with logo and CNC cit cast iron map wirh radium film over it vertically welded to the pole and fined facing with radium lettr ( In Hindi and English) |
134 | Providing and Fixing of the LED RAM VAN GAMAN PATH Letters of length 6M made and cut with CNC machine as per apporved drawng fonts and 8mm weather proof acrylic sheet internally fixed with a silicon and 3M adhesives and externally screwed in a MS frame with all needed accessories. |
135 | Stone work with SAND STONE exposed face fine dressing for making RAM BHAGWAN STATUE ,upto15 metre height including base platform upto 3 metre from G.L, backing filling with a grouting of 12 mm thik mortar 1:3 ( 1 cement :3 course sand) and approved stainless steel clam/pin etc shall be used to hold stone with necessory drilling. For joint fillied with a EPOXY basd adhesive pigment matching the stone shad as per approved drawing & Specification and under the overall direction of the Eingineer-in-charge. (The rate includes the neessary centring & shuttering ,transportation, installation and all required fixing arrangement). Complete in all respect as per drawing & design and instructions of Engineer-in-charge, the minimum quantity of sand stone to be used in Lord Rama Status should not be less than 80 cum. |
136 | Designing,Providing,installing and fixing factory finish GRC (Glass Fiber Reinforced Conctrete) cladding overSmal Entrance Gate.The minimum thickness of GRC panel 50mm thick @4.5Kg/sqft & approved texture and Colour. The framing of GRC Panel on primary structure by dry cladding method with S.S Screw, MS Angle,Plug and dowel pin proper allignment as per structural design at required location as per approved drawing & Specification and under the overall direction of the Eingineer-in-charge. (The rate includes the detailed design,fabrication of section,transportation, installation and all required fixing arrangement). |
137 | Providing and installing of AUTOMATIC TYPE PARKING BARRIER AT ENTRY AND EXIT POINT having ARM length 5.0 m ( 1 remote and push button) model no . CMP-100A |
138 | Providing and fixing of tensile fabric of saffron colour tied as per specification at the height of 5M from the road level in the geometric form as per drawing and following specification Weight: 700 g/m² Width: As per drawing length: As per drawing Type I-V: Type I Max. tensile strength: 3300/3000 N/5cm Tear strength: 375/325 N Application: Textile architecture Surface: high gloss, lacquered, PVDF weldable Properties: flame-retardant, fungicide finish, low-wick |
139 | Designing,Providing,installing and fixing factory finish GRC (Glass Fiber Reinforced Conctrete) cladding overMain Entrance Gate .The minimum thickness of GRC panel 50mm thick @4.5Kg/sqft & approved texture and Colour. The framing of GRC Panel on primary structure by dry cladding method with S.S Screw, MS Angle,Plug and dowel pin proper allignment as per structural design at required location as per approved drawing & Specification and under the overall direction of the Eingineer-in-charge. (The rate includes the detailed design,fabrication of section,transportation, installation and all required fixing arrangement). |
140 | Providing and installation of 6M high DEEP STAMBH as per enclosed design and photograph made out of Red/Yellow Sandstone with all finshes and sccafoldings. The work is artistic in nature , approx. 30 Cubic sandstone required /invoved including dressing, shaping, chissling, polishing, waxing and other related finishing with all required components of stone as per requirment |
141 | Providing and supplying of Central Gazzebo with decorative Cast iron pole Of 150mm dia with all decorative mouldings as per drawings with shingles of SAINT GOBAIN MAKE in roof profile on cemet noard of 12mm thicknessand wooden base of engineering wood on MS anlges of size 75mmx75mmx8mm |