Health and Family Welfare Government Departments Closing in 0 days TDR #28582287

Rate Contract Of Radiotherapy Goods (Group-13) For The Year 2021-2023

Issued by Government Departments · , Gujarat
Tender Value
75 Lakhs
Estimated cost
Bid Submission
10 Aug 2021
0 days left
EMD
2.25 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Rate Contract Of Radiotherapy Goods ( Group-13 ) For The Year 2021-20231 Thermoplastic Mask 4 Clamp Head And Neck 2 Thermoplastic Mask 3 Clamp Brain 3 Thermoplastic Mask 4 Clamp Pelvis 4 Thermoplastic Mask 6 Clamp Pelvis 5 Thermoplastic Mask 5 Clamp Head And Neck ( Push Pin ) 6 Thermoplastic Mask 3 Clamp Brain ( Push Pin ) 7 Thermoplastic Mask 4 Clamp Pelvis ( Push Pin ) 8 Thermoplastic Mask 6 Clamp Pelvis ( Push Pin ) 9 Pushpin For Thermoplastic Mask 10 Vaccum Bags ( Vaclok ) Radiolucent Nylon Bags Filled With Low Density Polystyrene Balls 11 Base Plate 12 Indexer Bar 13 Breast Board 14 Belly Board 15 Foot Fix And Knee Rest 16 Shoulder Retraction 17 Head Rest Set 18 Bolus Material 19 Brain Thermoplastic Mask Dsps 20 Gel Bolous 21 Volumetric Bar ( V-Bar ) 22 Tungsten Eye Shield 23 Testicle Shield

BOQ

S.NOTenderItemIDSr. No.Name of ItemSpecificationApprox. requirement for Two yearsUnit of measurement
1 . 171THERMOPLASTIC MASK 4 CLAMP HEAD AND NECK1) EXCELLENT QUALITY THERMOPLASTIC MATERIAL2) COMPATIBLE WITH ACRYLIC BASE PLATE/CARBON FIBRE BASE PLATE FOR SYNERGY (UNIVERSAL MULTI-BOARD)3) SHOULD NOT OBSTRUCT PATH OF BEAM4) UNIFORM THICKNESS AND UNIFORM CONTRACTION DURING COOLING5) COMFORTABLE TO PATIENT6) REPRODUCABLE WITH A PRECISE POSITION7) EASY TO MOLD8) CAN BE SHAPED VERY CLOSELY TO PATIENT ANATOMY PROVIDING EXCELLENT REPRODUCIBILITY9) NON-STICKY MATERIAL10) NON PERFORATED EDGE OFFERING COMFORT AROUND NECK AND NOSE11) MOVEMENT OF PATIENT CONSTRAINED12) USEBALE ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMS13) SURFACE DOSE SHOULD NOT BE ALTERED14) RIGID AND SHOULD HOLD ITS SHAPE OVER TREATMENT PERIOD TIME15) SOFTENS ON 69 DEGREE CELSIUS TEMPERATURE16) RE-USABLE FOR 2-3 TIMES17) THICKNESS FOR HEAD AND NECK-3.2 mm18) THICKNESS FOR BRAIN – 2.4 mm19) DEMONSTRATION IS MUST1400-
2 . 182THERMOPLASTIC MASK 3 CLAMP BRAINAs Above400-
3 . 193THERMOPLASTIC MASK 4 CLAMP PELVISAs Above200-
4 . 204THERMOPLASTIC MASK 6 CLAMP PELVISAs AboveAs and when required-
5 . 215THERMOPLASTIC MASK 5 CLAMP HEAD AND NECK (PUSH PIN)As Above800-
6 . 226THERMOPLASTIC MASK 3 CLAMP BRAIN (PUSH PIN)As Above200-
7 . 237THERMOPLASTIC MASK 4 CLAMP PELVIS (PUSH PIN)As Above200-
8 . 248THERMOPLASTIC MASK 6 CLAMP PELVIS (PUSH PIN)As AboveAs and when required-
9 . 259PUSHPIN FOR THERMOPLASTIC MASK-1000-
10 . 2610VACCUM BAGS(VACLOK) RADIOLUCENT NYLON BAGS FILLED WITH LOW DENSITY POLYSTYRENE BALLS1) RADIOLUCENT2) COMFORTABLE CUSHION3) ENTIRELY RIGID4) REUSABLE5) CONFORMS WELL TO GROSS SURFACE CHANGE6) ALMOST AIR EQUIVALENT7) WASHABLE8) NON PERMEABLE NYLON SHELLS THAT PREVENT PUNCTURE AND TEARS9) LEAK PROOF AND AIR TIGHT10) INDEXING BAR11) REPLICABLE VALVE OR VALVE COVER12) IT SHOULD MINIMALLY ATTENUATE PADIATION BEAM13) SIZE : 50x70,70x70,100x70,200x100(cm 2)14) DEMONSTRATION IS MUST15) COMPATIBLE ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMSAs and when required-
11 . 2711BASE PLATE1) CARBON FIBRE MATERIAL2) STRONG3) SHOULD FIX Thermo plastic mask PROPERLY4) MINIMALLY ATTENUATE RADIATION BEAM5) DEMONSTRATION IS MUST6) COMPATIBLE ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMSAs and when required-
12 . 2812INDEXER BAR1) TWO PIN INDEXER BAR2) CARBON FIBRE OR ANY OTHER SUITABLE MATERIAL WITH MILLIMETER PRECISION3) SHOULD BE ABLE TO PRODUCE STABLE FIXATION OF BASE PLATE TO FIXATION COUCH4) IT SHOULD BE LOCKED BY ROTATING PIN FOR PRECISE REPRODUCTION5) DEMONSTRATION IS MUST6) COMPATIBLE ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMSAs and when required-
13 . 2913BREAST BOARD1) CARBON FIBRE MATERIAL2) WIDE RANGE OF INDEXED TILT ANGLES Rigid and easy to handle inclination brackets providing breast board angles from 5º - 45º in 2.5º steps, the brackets should fold in the bottom plate for easy handling. ALLOWS CHEST WALL POSITION HORIZONTALLY3) ADJUSTABLE ARM SUPPORT TO BRING ARM ABOVE THE SHOULDER AND OUT OF TANGENTIL FIELD: ADJUSTABLE FEATURES TO ALLOW FOR MANIPULATION OF PATIENTS ARM,WRIST,HEAD AND SHOULDERS BACK SUPPORT:4) LIGHT WEIGHT DURABLE TO PREVENT INTERFERENCE WITH TANGENTIEL FIELD5) DEMONSTRATION IS MUST6) Compatible ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMSAs and when required-
14 . 3014BELLY BOARD1) THICK MATTRESS FOR SUPPORTING PATIENT’S PRONE POSITION WITH A WINDOW CUTOUT FOR PATIENT’S BELLY2) PROVIDES MORE COMFORT AND STABILITY IN PRONE POSITION FOR OBESE PATIENT3) REDUCE AMOUNT OF INTESTINE IN LATERAL RADIATION FIELD4) ABLE TO FIX WITH TREATMENT COUCH/MULTI- BOARD WITH INDEXER BAR5) DEMONSTRATION IS MUST6) Compatible ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMSAs and when required-
15 . 3115FOOT FIX AND KNEE REST1) STABILIZES PELVIS2) CARBON FIBRE3) ABLE TO FIX WITH MULTI-BOARD/TREATMENT COUCH WIYH INDEXER BAR4) KNEE REST WITH COMBINED ADJUSTABLE FOOT FIX5) DEMONSTRATION IS MUST6) Compatible ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMSAs and when required-
16 . 3216SHOULDER RETRACTION1) EASY REPRODUCIBILITY2) COMPATIBLE WITH ACRYLIC BASEPLATE AND MULTIBOARD3) FOR HEAD AND NECK PATIENTS4) DEMONSTRATION IS MUST5) Compatible ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMSAs and when required-
17 . 3317HEAD REST SET1) CARBON FIBRE Or MINIMALLY ATTENUATED FOAM MATERIAL2) ANGLES OF 25, 35 AND 45 DEGREE3) FOR SUPINE AND PRONE4) ANGLED WEDGES(5,10 AND 15 DEGREE)5) PEDIATRIC HEAD REST6) COMPATIBLE WITH ACRYLIC BASE PLATE/MULTI- BOARD(SYNERGY)7) DEMONSTRATION IS MUST8) Different Types ACCORDING TO HEAD AND NECK CURVATURE (ABCDE) 9) Compatible ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMSAs and when required-
18 . 3418BOLUS MATERIAL1) HOMOGENOUS WAX MATERIAL2) COMPATIBLE ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMS3) DEMONSTRATION IS MUSTAs and when required-
19 . 3519BRAIN THERMOPLASTIC MASK DSPS1) DOUBLE CELL POSITIONING SYSTEM BRAIN Thermo plastic mask WITH PUSHPIN(DSPS) RAINFORCED THERMOPLASTIC AVAILABLE WITH / WITHOUT PUSHPIN TO BE USED WITH CLAMP SYSTEM2) Compatible ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMS3) DEMONSTRATION IS MUSTAs and when required-
20 . 3620GEL BOLOUS1) 30 CM X 30 CM X 1 CM2) Compatible ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMS3) DEMONSTRATION IS MUSTAs and when required-
21 . 3721Volumetric Bar (V-Bar)1) Should be able to produce stable fixation of the vac-lock to the AlO couch2) Made up of Carbon fibre material.3) Minimally attenuate radiation beam4) Compatible for all in one (AIO) Carbon fibre couch of POCL company in Varian Vital Beam machine.5) Compatible ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMS6) Demonstration is mustAs and when required-
22 . 3822TUNGSTEN EYE SHIELD1) PROTECTION OF OCULAR STRUCTURE FOR ELECTRONS UPTO 9-12 MeV2) EYE SHIELD IS COATED WITH DENTAL ACRYLIC MATERIAL TO REDUCE ELECTRON BACK-SCATTER TO AN ACCEPTABLE LEVEL3) SMALL, MEDIUM AND LARGE SIZE4) DEMONSTRATION IS MUST5) Compatible ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMSAs and when required-
23 . 3923TESTICLE SHIELD1) REDUCE SCATTER RADIATION TO TESTICLE TO AN ACCEPTABLE LEVEL2) MADE UP OF LEAD MATERIAL3) OPEN SECTOR TO ALLOW COMFORTABLE ATTACHMENT TO THE PATIENT AND UNITE TOGETHER PROPERLY4)ALL SURFACES ARE COATED WITH POLYURETHANE PAINT5) SMALL, MEDIUM AND LARGE SIZE6) WITH ADJUSTABLE STAND OFFERS INCREASED COMFORT TO THE PATIENT WHILE RAISING AND LOWERING THE SHIELD7) MANNUAL ADJUSTMENT KNOB ALLOWS FOR EASY VERTICAL POSITIONS FROM 1-10 INCH8) Compatible ON CONVENTIONAL SIMULATOR, CT/MRI AND OTHER PLANNING SYSTEMS9) DEMONSTRATION IS MUSTAs and when required-
S.NOTenderItemIDSr. No.Name of ItemSpecificationApprox. requirement for Two yearsUnit of measurement
1 . 124High density head rest (timo head rest)(1) Made up of durable polyurethane foam with washable coating. (2) Required head rests for CT Compatibility only.(3) Strong and comfortable to patient’s head & neck(4) Compatible for all in one (AIO) Carbon fibre couch(board) of POCLCompany in Varian Vital Beam machine.(5) M.nimaIly attenuate radiation beam(6) Different sizes is required A,B,C,D,E,F(7) Demonstration is must.(8) Quantity : 2 Sets of each sizes2Per Each
2 . 225V-Bar (Volumetric Bar)(1) CT Compatible(2) Made up of Carbon fibre material(3) Should minimally attenuate radiation beam(4) Should be able to produce stable fixation of the Vac-lock to theAiO couch (Board)(5) Compatible for all in cne (AIO) Carbon fibre couch(Board) of POCL Company in Varian Vital Beam machine.(6) Demonstration is must.(7) Quantity : 2 Piece2Per Each
3 . 326Head & Neck SClamp mask(1) Excellent Quality thermoplastic material, Non-Sticky material, CT Compatible(2) Uniform thickness and uniform contraction during and after cooling, head and neck mask thickness 3.2mm(3) Non perforated edge offering comfoil around neck and nose Usable on conventional simulator, CT/MRI and other planning system(4) frigid and should hold its shape over treatment period(5) Reproducible with precise position(6) Re-usable for 2-3 tim°s(7) Easy to mould, Comfortable to Patient(8)Can be shaped very closely to patient’s anatomy(9) Should not obstruct path of Beam.(10) Surface dose should not be altered(11)Movement of patient constrained.(12)Compatible for all in one (AIO) Carbon fibre couch(board) of POCL Company in Varian Vital Beam machine.(14)Demonstration is must.100Per Each
4 . 427Pelvis 6 clamp• As described above50Per Each
5 . 528Pelvis 4 clamp• As described above40Per Each
6 . 629Belt for brain patient• Used for patients with brain Mets/brain tumour to prevent accident (fall)2Per Each
7 . 730Secondary base plate(1)Made up of carbon fibre, strong, CT Compatible.(2)Should fix thermoplastic mask properly(3) Without secondary base plate, neck & thorax 4 clamp mask cannot be used in Carcinoma Lung and Carcinoma Breast cancerpatients.\"(4)Minimallv attenuate radiation beam.(5) Compatible for all in one (AIO) Carbon fibre couch(board) ol POCL company in Varian Vital Beam machine.(6) Demonstration is must.(7) Quantity : 2 Piece2Per Each
8 . 831Storage cabinet(AIO)• To protect accessories from damage we put in storage cabinet2Per Each
9 . 932Water Bath cIean=r• To avoid damage from dust in water bath.2Per Each
10 . 1033Ink for Tattoo• Used in thorax & pelvis patients for reference marking1 Box (50)Per Each
11 . 1134Copper wire• Used in immobilization for patient.20 meterPer Each
12 . 1235Plastic wrapping• Couch shielding purpose1Per Each
13 . 1336rone breast accessoryTo treat the bulky breast patient in prone position1] Caudal cushion standard 15 cm clearance2] Cushion standard 15 cm clearance3) Caudal cushion elevation to 23 cm clearance4] Cushion elevation to 23 cm clearance5) support cushion for contra lateral breast carbon fibre insert6) lateralâ€

AI Tender Summary

OUR REF NO 28582287
AUTHORITY Government Departments
TENDER VALUE 75 Lakhs
LAST DATE 10-08-2021
Authority
Authority Name Gujarat Cancer And Research Institute
Work Description Rate Contract Of Radiotherapy Goods ( Group-13 ) For The Year 2021-20231 Thermoplastic Mask 4 Clamp Head And Neck 2 Thermoplastic Mask 3 Clamp Brain 3 Thermoplastic Mask 4 Clamp Pelvis 4 Thermoplastic Mask 6 Clamp Pelvis 5 Thermoplastic Mask 5 Clamp Head And Neck ( Push Pin ) 6 Thermoplastic Mask 3 Clamp Brain ( Push Pin ) 7 Thermoplastic Mask 4 Clamp Pelvis ( Push Pin ) 8 Thermoplastic Mask 6 Clamp Pelvis ( Push Pin ) 9 Pushpin For Thermoplastic Mask 10 Vaccum Bags ( Vaclok ) Radiolucent Nylon Bags Filled With Low Density Polystyrene Balls 11 Base Plate 12 Indexer Bar 13 Breast Board 14 Belly Board 15 Foot Fix And Knee Rest 16 Shoulder Retraction 17 Head Rest Set 18 Bolus Material 19 Brain Thermoplastic Mask Dsps 20 Gel Bolous 21 Volumetric Bar ( V-Bar ) 22 Tungsten Eye Shield 23 Testicle Shield
Basic Detail
Tender No 2021-2023
Bidding Type Tender
Location
City
State Gujarat
Key Dates
Publish Date 20 Jul 2021
Submission Date 10 Aug 2021
Open Date 11 Aug 2021
Finance
Tender Value 75 Lakhs
Tender Fee 5900
EMD 2.25 Lakhs
Exemption Not Available
Document List
09d89ea4-fb8c-4fd9-beab-ac23dfabc463.html
Terms and Conditions Radiotherpay 2021.pdf
Commercial RT.pdf
Technical RT.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 20, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 11, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

09d89ea4-fb8c-4fd9-beab-ac23dfabc463.html

pdf

Terms and Conditions Radiotherpay 2021.pdf

pdf

Commercial RT.pdf

pdf

Technical RT.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders