Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #28574833

Annual Electric Repairs Stage Work 2021 And 2022 Annual Electric Repairs Of Staff Quarters Vc Lodge Gils Hostels Faculty Transit House At Lower Residential Area Etc At Old University Campus Stage 2021 And 2020

Issued by Boards / Undertakings / PSU · University of Jammu, Jammu And Kashmir
Tender Value
7 Lakhs
Estimated cost
Bid Submission
28 Jul 2021
0 days left
EMD
14000
Bank guarantee accepted
Document Fee
100
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
University of Jammu → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Annual Electric Repairs Stage Work 2021 And 2022 Annual Electric Repairs Of Staff Quarters Vc Lodge Gils Hostels Faculty Transit House At Lower Residential Area Etc At Old University Campus Stage 2021 And 2020

BOQ

Name of Work: Annual Electric Repairs of Staff Quarters, V.C Lodge, Girls Hostels, Faculty Transit House at Lower Residential Area of New Campus and Repair of Street Lights/Flood Lights/Post Lights/Bollard Lights/Gate Lights/Landscaping & Garden Lights and Boys Hostel & Staff Quarters at Old University Campus, Canal Road, Jammu (Stage 2021-22)
Sl. No. Item Description
1Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic, laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable etc. as required. (WireMake ISI Marked Havells/Anchor /HPL /KEI/Polycab) (Conduit Make - ISI Marked Anchor/High Power /AKG) Group ‘A’
2-------------do-----------------do-----Group \"B\"
3-------------do------------------do----- Group \"C\"
4Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. (WireMake ISI Marked Havells/Anchor/HPL/KEI/polycab)2 x 1.5 + 1 x 1.5 Sqmm earthwire
5------------do------------- 2 x 2.5 + 1 x 2.5 Sqmm earthwire
6------------do------------- 2 x 4 + 1 x 4 Sqmm earthwire
7------------do------------- 2 x 6 +1 x 6 Sqmm earthwire
8Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required-ISI Marked Anchor/High Power /AKG)25 mm dia
9Supplying and fixing 5 amp to 32 amps rating, 240/415 volts, 10 KA \"C\" curve miniature circuit breaker of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make Havells/Anchor/C&S//HPL)Single pole
10Earthing with Copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required.
11Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing as required.
12Supply and fixing of metal Box of following size on the surface/recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 100mm x 100mm x 60mm deep
13-----------do------------------do------ 200mm x 125mm x 60mm deep
14Supply & fixing 15/16 amp piano type switch on the existing switch box or cover including connection as required. (Make:Anchor /Havells/ HPL/ Great White/Sanchi major)
15Supply & fixing 6 pin 15/16 amp socket outlet on the existing switch box or cover including connection as required (Make: Havells/HPL/Anchor/Great White/Sanchi major)
16Supply & fixing 5/6 amp piano type switch on the existing switch box or cover including connection as required (Make :Havells/ HPL/Anchor/Great White Sanchi major)
17Supply & fixing 3 pin 5/6 amp socket outlet on the existing switch box or cover including connection as required (Make: Havells/ HPL /Anchor /Sanchi major/Great white)
18Supplying and fixing following ways and poles, plain/horizontal sheet steel MCB Distribution Board on surface/in recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections including powder painted earthing etc. as required (But without MCB/RCCB/Isolators) (Havells /Anchor /I.A /HPL)8 way, 240 volts, single pole and neutral Double Door
19----do---- ---do----8 way (4+24), 415 volts, three pole and neutral Double Door
20Supplying and fixing DP sheet steel enclosure on the surface/ recess along with 25/32 Amp 240 volts ‘C’ curve DP MCB complete with Connection testing and commissioning etc.as reqd. (Make Havells/HPL /Anchor)
21Supply & fixing piano type Telephone socket outlet on the existing Switch Box or cover including connection as required (Make Havells/HPL/Anchor)
22Supplying & drawing 2 pair (0.50)sqmm FR PVC insulated annealed copper conductor un armoured telephone cables in the existing surface/recessed steel or PVC Conduit as required (Make ISI Marked Havells/Anchor/ KEI/HPL)
23Supply & fixing two module stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. as required. (Make Havells/ HPL /Anchor /SSK/ C&S/Great White/Sanchi Major)
24Supplying and fixing brass batten/Angle holder including connection etc. as required. (Make Havells/ HPL /Anchor / C&S/Great White/ Sanchi Major)
25Supplying and fixing 3 pin, 5 A Ceiling Rose on the existing junction box/wooden block including connection etc. as required. (Make Havells/ HPL /Anchor /SSK/ C&S/Great White/ Sanchi Major)
26Providing and fixing following rating and breaking capacity MCCB with Thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make Anchor /Havells /HPL/I.A)125 AMP 36K FP MCCB
27----------do------------200 AMP 36KFP MCCB
28----------do------------400 Amp 50 K FP MCCB
29aying of one number PVC Insulated and PVC sheathed/XLPE power cable 1.1 KV grade of following size cables direct in ground including excavation, refilling the trench etc as required but excluding sand cushioning and protective covering. UPTO 35 sq mm
30Supply and fixing of Piano type TV Antenna Socket outlet on the existing switch box/cover including connection as reqd. (Make ANCHOR/ HPL/ HAVELLS/ C&S)
31Supply and drawing co-axial TV cable RG-6 grade,0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/Recessed steel/PVC conduit as Reqd. (Make ANCHOR/HPL/HAVELLS/C&S)
32Supply and drawing UTP 4 Pair Cat 6 LAN Cable in the existing surface/recessed steel/PVC conduit as required (Make Legrand /Havells / Anchor/D Link /HPL/L&T) 1 run of cable
33Re-wiring for light point/fan point/call bell point exhaust fan point with 1.5 Sqm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (WireMake ISI Marked Havells/Anchor/HPL/KEI/Polycab) (Conduit Make -ISI Marked Anchor/High Power /Finlox/National Gold/Shalimar /Ravindra) Group ‘A’
34------------do----------------------------do----------Group \"B\"
35Supplying and fixing of following ratings and poles 240/415 volts SPN/Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required (Make Havells /Legrand /Anchor/ C&S/L&T/ Siemen/IA/HPL/Standard) 40 Amp, 240 volt, Double Pole
36------------do---------------- 63 Amp,240 volt, Double Pole Isolator
37-------------do---------------- 63 Amp,415 volt, Four Pole Isolator
38Supplying and drawing of following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (WireMake ISI Marked Havells/ Bonton /Anchor /Grandley/L&T/HPL/Shalimar/KEI/Polycab)1 x 1.5 sqmm
39------------do----------- 2 x 1.5 sqmm
40------------do------------2 x 2.5 sqmm
41------------do-------------- 2 x 6.0 sqmm
42------------do------------- 4 x 4 sqmm
43------------do--------------4 x 6 sqmm
44P/F M.V danger plate of (200x150) mm made of mild steel at least 2mm thick and vitreous enameled white on both side and with inscription in single red colour on front side as reqd.
45Supply/Installation testing and commissioning of following type of surface mounted/recessed mounted decorative Indoor Linearwith extruded Al. heat sink, environmental friendly energy efficient LED tube Light decorative energy efficient square moulded LED energy saving type. Make (Halonix/ Havells/Bajaj/Greatwhite/ Philips/ HPL/Compact/Anchor/C&S)4 feet 18 to 22 watt ,230 volts LED batten type tube light fitting complete
46--------do-------12 To 18 Watt LED recessed/surface mounting down, 6500 K, 240 Volts as per cat : GARNET Slim Panel Light square./ Round. 225 x 225 mm to 300 x 300 mm dimension
47Supply/installation of the following type of outdoor decorative faced light, bollard light, flood light/gate lights and Street lights luminaries complete with all accessories connection testing and commissioning as required including making the PCC foundation with nut and bolts where required as per following.Make (Bajaj/Legrand /Surya /Havells/Hager/ C&S/ HPLwipro/ compact/ Halonix) 45 to 60 watt, 230 volts IP 66/IP65 LED
48Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, bus bar support and terminations, interconnection between bus bars & switch gear with auxiliary bus bars/insulated conductors/strips etc. The panel shall be fabricated out of CRCA not less than 2.00 mm thick for the load bearing members and 1.6mm for doors of L.T Panels. The frame work may be Agle Iron/Channel/Bolted type construction should be arrangement for I/C/O/G. Cable termination with 2 Each. 20x5mm cu. Strip fixed all around the panel connected to 2 Each. earth bars cu-strips connected to incoming earth conductor.(Make Electric Field/ Bharti Engineers/Gupta & Friends/ Semon/ Jai maa/U.S.Electrical works) MAIN OUTDOOR /BUILDING CONTROL PANEL a. INCOMING Space for 1 No. 200 to 630 Amp TPN Al. Bus bar of equal cross section for Main Power connection to Main MCCB.Space for 1 No. 200 to 630 Amp 4 pole MCCB of 35 KA Space for 1 no. 3-phase 5-wire Progdy type electronicmeter.b. INDICATING PANELThe indicating panel of the incomer shall be provided with the following:i. Ammeter of required range with ASS, CT\"s.ii.Voltmeter of required range with VSS.c.OUTGOINGSpace for1 No. 200 to 630 Amp TPN Al. Bus bar of equal cross section for power load/light load.Dimensions = 2’x 2’ x 1’6”
49-------------do-----------MAIN NORMAL CUM EMRENGECYa. INCOMING Space for 1 No. 100-630 Amp MCCB 35 KAb. INDICATING PANELThe indicating panel of the incomer shall be providedwith the following:i. Ammeter of required range with ASS, CT\"s.ii.Voltmeter of required range with VSS.c.BUS BARSpace for 1 No. 100-630 Amp TPN Al. Bus bar of equal cross section for power load.d.OUTGOINGSpace for 2 to 4No. 63-200Amp4 pole MCCB Dimensions = 3’ x2 x 1’6”
50Supply, testing and commissioning of PVC sheathed Aluminum conductor 1100 volts graded PVC AA Armoured/unarmoured XLPECable including end termination, crimping, cost of thimbles, nuts bolts, glands, connection, testing and commissioning complete job. (Make Havells /CCI/ Grandley /Finlox /Plaza / General/Polycab/Gloster) 2 core 16 sq mm armoured cable
51---------do---------- 3 ½ core 35 sq mm armoured cable
52---------do--------- 3 ½ core 120 sq mm armoured cable
53Supply, installation, testing, commissioningof 1200 mm sweep ceiling fans complete with bladesBEE 4 to 5 star rated energy efficient .(Make: Havells /Anchor/Bajaj /Compact)
54Supply /Installation testing and commissioning of 450 mm sweep wall mounted fan including the electronic regulators and connection with testing and commissioning etc complete JobBEE 4 to 5 star rated energy efficient. Make: (Anchor /Bajaj /Havells )
55Supply, installation, testing, commissioning of heavy duty 300 mmsweepBEE 4 to 5 star rated energy efficient exhaust fan. Make: ( Usha / Orient /Anchor/Havellls)
56Supply & installation of CAT 6 2 module toll lessinformation outlets complying fully or exceeding with category 6 connecting hardware specifications for all pair combinations upto 250 MHz. Outlets shall use lead frame technology, non PCB pyramid type complete as required. (Make Legrand/Delton/Systemax /Penuit/ Havells/HPL/Anchor)
57Supply and installation of Singlex Face Plates along with clearly printed labels and holders complete as required (Make Legrand /Havells / Anchor/D Link /HPL/L&T/G.E)
58S/F of 32mm dia G.I pipe for flood light bracket including bending to shape, (40x3)mm flat iron clamp and wiring with 1.5 sqmm PVC insulated wire complete wire complete as reqd.
59P/F following rating 230 volts energy saver LED Lamps and LED Tubes 4’ long (Make :Philip /Havells/Bajaj/ Surya/ Crompton/ Wipro/Compact/Halonix)8 to12 watt LED
60-------------------do--------------------18 to 25 Watt LED
61-------------------do-------------------- 18 to 22 Watt LED 4’ long tube rod
62--------------------do-------------------11 to 18 Watt 2pin/4pin type LED
63Supplying and fixing bus bar chamber with 4 strips bus bar of following size, made of the copper, suitable for following capacity complete with all accessories including connections, earthing the body as required.450mm 100 Amp
64-------------------do-------------------450mm 200 Amp
65Providing/fixing following way PVC gang box suitable for following socket and switches.(Havells/Anchor/SSK make)3 pin 5 Amp socket with switch
66-------------------do--------------- 6 pin 15 amp socket with switch
67Providing/fixing 40 amp rating , 230 volts SPN MCB in the existing MCB DB or enclose complete with connection testing and commissing complete Job. (Havells/Anchor/SSK make)
68Providing/fixing Ding Dong wall bell including connection as required (Anchor/SSK/Klick)
69Providing/fixing following rating plug tops (Anchor/Sanchi major/SSK make) 3 pin 5 Amp
70---------------do----------------3 pin 15 Amp
71P/F of 3mm thick phenolic laminated sheets of following size. Crown /Hylam. 5\" x 5\"
72--------------do-----------------9\" x 6\"
73---------------do----------------- 11\" x 13\"
74--------------do------------------- 3\" Round
75-------------do------------------- 5\" Round
76Providing and fixing of PVC/Wooden boards of following size. Crown/Hylam. 4\" x 4\"
77----------------do------------------ 8\" x 5\"
78----------------do------------------ 8\" x 10\"
79-----------------do---------------- 11\" x 13\"
80Supplying and fixing Post Lantern fittings as per CAT No: BMGSCFL Retrofit with globe cover mounted on Aluminum capsule suitable for 20 watt energy saver CFG including cost of 2.5\" x 2\" size G.I reducer for fixing on existing pole wherever required(Make Bajaj /Glomac /Havells/Wipro).
81P/laying of 100 mm dia heavy duty PVC pipe in ground including digging the pit and refilling complete job. (prince/supreme/Astral/Uniplas)
82Supply and fixing of following rating onload I-O-II Four pole with advanced neutral on load change over switch confirms to IS 13947 (Part-3) IEC:609473) (Make Legrand/ I.A/Havells /Siemen/HPL) 100 Amp
83-----------------do---------------- 200 Amp
84-----------------do-------------- 315 Amp/400 Amp

AI Tender Summary

OUR REF NO 28574833
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 7 Lakhs
LAST DATE 28-07-2021
Authority
Authority Name University Of Jammu
Work Description Annual Electric Repairs Stage Work 2021 And 2022 Annual Electric Repairs Of Staff Quarters Vc Lodge Gils Hostels Faculty Transit House At Lower Residential Area Etc At Old University Campus Stage 2021 And 2020
Basic Detail
Tender No enit 510 dated 8-7-21
Bidding Type Tender
Location
City University of Jammu
State Jammu And Kashmir
Key Dates
Publish Date 19 Jul 2021
Submission Date 28 Jul 2021
Open Date 30 Jul 2021
Finance
Tender Value 7 Lakhs
Tender Fee 100
EMD 14000
Exemption Not Available
Document List
Tendernotice_1.pdf
62cca065-b660-4203-be39-4282f4c57d95.html
BOQ_260554.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 19, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 30, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

62cca065-b660-4203-be39-4282f4c57d95.html

xls

BOQ_260554.xls

Disclaimer