| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m deep foundation and getting out in hard/dense soil. |
| 2 | Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar for 150mm bore complete all as specified & directed. |
| 3 | Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar for 100 mm bore complete all as specified & directed. |
| 4 | S&F PVC (SWR) pipes single socketed 160 mm dia in any length with rubber ring joints laid in trenches or floor complete all as specified and directed. |
| 5 | S&F PVC (SWR) pipes single socketed 110 mm dia in any length with rubber ring joints laid in trenches or floor complete all as specified and directed. |
| 6 | Removing excavated material n exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 7 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed. |
| 8 | M&L for PCC 1:3:6 type C2(using 40 mm graded aggregate) to bed of drain pipes including packing under and haunching against the sides of pipes, after they are laid and tested for 160mm bore pipe complete all as specified and directed. |
| 9 | M&L for PCC 1:3:6 type C2(using 40 mm graded aggregate) to bed of drain pipes including packing under and haunching against the sides of pipes, after they are laid and tested for 110mm bore pipe complete all as specified and directed. |
| 10 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20 mm graded completed) smooth finished, and reforming benching as required complete (Internal dia of pipe 160 mm) all as specified and directed. |
| 11 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20 mm grades complete) smooth finished, and reforming benching as required (Internal dia of pipe 110 mm) complete all as specified and directed. |
| 12 | M&L for cleaning of SGSW / PVC SWR pipe line 150/ 160 mm bore size by roding or by pressure pump completely excluding connected manhole, any depth and removal of sludge etc to a distance as specified under particular specification Note: Man holes measure and paid separately in respective schedule due to huge size of manholes Complete all as specified and directed. |
| 13 | M&L for cleaning of SGSW / PVC SWR pipe line 100/ 110 mm bore size by roding or by pressure pump completely including connected manhole, any depth and removal of sludge etc to a distance as specified under particular specification and directed. |
| 14 | M&L for dewatering of soak well or sewage pit of any size and depth upto 3.5m and manholes manually or by using pump and removal of sludge if any to a distance exc 1.5 Km but not exc 5 KM out of MD land complete all as specified and directed. |
| 15 | Cleaning of septic tank chamber by removing effluent water and sludge and buried the same in excavated pits, by digging pits in hard/dense soil including removing surplus earth to a distance not exceeding 50 mtr from starting point and filling up the top portion of pit by excavated soil and sprinkling bleaching powder @ 0.5 Kg per Sqm on excavated areas including temporary baricades complete all as specified and directed. |
| 16 | Demolition of brickwork or solid block / stone boulder masonry, built in cement mortar including all quoins, pillars, etcall as specified and directed. |
| 17 | M&L for providing pre-cast cement concrete block masonry 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) solid blocks, exc. 10 cm in width and setting in cement mortar (1:4), complete complete all as specified and directed. |
| 18 | Demolition of precast RCC in ground floor and pavings n exc 15 cm thickness (below or above ground complete all as specified and directed. |
| 19 | M&L for precast cement concrete type B1 1:2:4 (using 20mm graded aggregate) in cover slab for manholes and similar articles with plain faces and set in CM 1:6 complete all as specified and as directed. |
| 20 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 21 | Taking down of cement plaster of any description on brick including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 22 | M&L for 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 23 | Supply only integral water proofing compound complete all as specified and directed. |
| 24 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 25 | Demolition of cement conrete un reinforced in floors n exc 15 cm thickness in ground floor (below or above GL) completed all as specified and directed . |
| 26 | Material and labour for PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation filling and mass concrete etc complete all as specified and directed. |
| 27 | M&L for 15mm thick plaster on concrete surface in CM 1:4 usinf WPC @3% by weight of cement and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. (Note: WPC shall measured and paid seprately |
| 28 | M&L formwork to edges of concrete flats, n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or slooping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and directed |