|
| 1 | Operation and maintenance of water supply installations daily (without any holidays) in two shifts of eight hours each with minimum one skilled persons/tradesman (FGM) including maintaining the installation premises neat and clean and closely monitoting the electrical and mechanical systems every one hour duly maintaining the record all as directed by the Engineer-in-charge for the following installations :Location :8 BRD Pump house and DG sets /shed no 59 DG set(a)Operating the valves in UG sump 30000 gallons - 01 No(b)Operating theBore well with submersible pump sets - 01 No.(c)Operating theOpen well submiersible pump set capacity 10 HP - 02 Nos(d) Operating the Chlorine solution dosing plant - 02 No(e)Operating the valves in Over head tank 50000 gallons- 01 No(f)Operating the DG sets at shed no: 59 ,100 KVAalong with control panel and distribution(g)Operating the DG sets at 8BRD set of capacity 100/160 KVA. 2 NosFirst Shift from 0600hrs to 1400 hrsNos of skilled persons for first shift-1 NoSecond shift fron 1400hrs to 2200hrsNo of skilled persons for second shift-1 NoTotal No of skilled persons required per day-2 Nos |
| 2 | Operation and maintenance of water supply installations daily (without any holidays) in single shift of eight hours with minimum one skilled persons/tradesman (FGM) including maintaining the installation premises neat and clean and closely monitoting the electrical and mechanical systems every one hour duly maintaining the record all as directed by the Engineer-in-charge for the following installations :Location : Engine Test Bed Pump House and MTTI Pump (a)Operating the Stand by DG set at MTTI HQ of capacity 100 KVA -01 No(b)Operating the Stand by DG set at Simulator Bldg of capacity 320 KVA -01 No (c)Operating the Stand by DG sets at old / new computer lab of capacity 63 KVA -02 Nos (d)Operating the Stand by DG set at Signal section of capacity 125 KVA - 01 Nos(e)Operating the Stand by DG set at (2) T Sqdn of capacity40 KVA -01 No(f)Monitoring of the LT panel board with control / distribution panels. Shift from 0600hrs to 1400 hrsNos of skilled persons for first shift-1 NoTotal No of skilled persons required per day- 1 No |
| 3 | Operation and maintenance of water supply installations daily (without any holidays) in single shift of eight hours with minimum one skilled persons/tradesman (Electrician) including maintaining the installation premises neat and clean and closely monitoting the electrical and mechanical systems every one hour duly maintaining the record all as directed by the Engineer-in-charge for the following installations :Location:- SPH,UCPH,DC-I and DC -II 11KV sub-station(a) Operating of Gang Operating Devices -04 Nos(b)Monitoring ofTransformer 250KVA - 01 No(c)Monitoring ofTransformer 200 KVA - 02 No(d)Monitoring ofTransformer 160KVA - 01 NoShift from 0600hrs to 1400 hrsNos of skilled persons for first shift-1 NoTotal No of skilled persons required per day- 1 No |
| 4 | FGM /Electrician (Skilled) per person as per existing rates. |
| 5 | Employees Provident Fund as per existing rates |
| 6 | Employees State Insurance as per existing rates |
| 7 | Over Head & Profit on total of Srl No. 4.00 to 6.00 |
| 8 | Labour Welfare Cess (LWC) on total of Srl No. 4.00 to 7.00 |
| 9 | GST as per existing rates on total of Srl No. 4.00 to 8.00 |
| 10 | Notes for BOQ Srl item No 1 to 9 :-(a) The rate quoted for items of Manning and Operation shall not be less than minimum fare wages as notified by Govt of India / State Govt whichever is higher and also not less than applicable rates for contribution of employer towards EPF, ESIC, LWC and GST under respective headings / sub items.In case the rates quoted are less than previling rates / instruction under any headings / sub items, the bid will be treated as non bonafied / invalid, shall be disqualified and such bids will not be consider for acceptance.In such case the lowest bidder shall be determined from amongst the valid / bonafidde bids only.(b) Employees will be trained and well acquainted with operation and maintenance of pump sets. (c) Comprehensive maintenance of sluice valves, Non return valves and replacement of rubber gaskets, leathers, to attend break down of pumping pipe lines, day to day complaints completely in the shifts all as specified and as directed. (d) The rate considered is deemed to include the consumables required for operation and normal maintenance of Pump Sets and all types of valves, cotton waste, grease, gland rope, fuse wire, insulation rape etc.(e) The rate considered is deemed to be includedthe cost towards uniform for the staff employed for wearing during working hours. The uniform shall be Pant and shirt and the colour and pattern shall be decided by the GE. |
| 11 | Notes for BOQ Srl item No 1 to 9 :-(f) The rate considered is deemed to be inclusive of the documents such as Log Book, Running & Maintenance Record Book, Attendance register, Misc Items etc.(g)General cleanliness and upkeeping existing plants and vegetation within the premises of the plant by deploying additional manpower with T&P if required at any time and all as directed by Engineer-in-Charge.(h) For the purpose of payment of minimum fair wages, FGM / Electrician shall be considered as skilled worker.(j) Contractor shall made payment through authorised bank and photocopy of receipt of payment from the employer as per the format as directed by the GE shall be attached with RAR/FB.(k) Contractor shall also submit proof of contributions made towards EPF & ESIC for the employees engaged at the time of claiming RAR/FB.(l) Duty roster will be submitted by the contractor before commencement of the month for obtaining the approval of JE and Engineer-in-charge. Any change the duty roster will be made by the contractor, only after approval of Engineer-in-charge.(m) Contractor shall monitor the duties of all FGMs/Electricians and submit report to concerned Engr-in-Charge/ JE E/M regarding availability of manpower and also monitor for watch and guard of installation. Any loss of damage to the plant equipment installed and Govt. property in the installation premises shall be made good by the contractor. Rates quoted by the contractor are deemed to include for this clause. |
| 12 | Notes for BOQ Srl item No 1 to 9 :-(n) Contractor should arrange proper uniform with name plate displayed in shirt for the mechanics and its cost shall be deemed to be inclusive in the quoted rate.(o) The rate quoted shall not be less than minimum wages as notified by Govt of India/ State Govt/ Local body whichever is higher including all statutory provisions such as EPF, ESIC, Taxes etc and rate of GST as applicable on the last due date of bid submission. (p) \"NIL\" or \"Zero\" Quoting against OH & Profit shall be render the bids as \"Non-bonafide\"(q) Contractor is required to quote upto two digit after decimal place or otherwise it will be considered by rounding off to two digits after decimal place. |
| 13 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, laying cables, pipes etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5m depthand getting out in any type of soil all as specified and as directed. |
| 14 | Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 15 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed. |
| 16 | Dry river sand laid to required width of trench at bottom and top forcable cushioning all as specified and as directed. |
| 17 | Burnt bricks sub class \"B\" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection all as specified and as directed. |
| 18 | Taking out existing cable any type / cross sectionand supply, laying, connecting and testing XLPE insulated, armoured,heavy duty electric cable with aluminium conductor of cross sectional area 95sqmm, 3 core, 11000 volts grade, in trenches / drawn through pipe / fixed on walls/ bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed. |
| 19 | Taking out existing cable any type / cross sectionand supply, laying, connecting and testing XLPE insulated, armoured,heavy duty electric cable with aluminium conductor of cross sectional area 120sqmm, 3.5 core, 1100 volts grade, in trenches / drawn through pipe / fixed on walls/ bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed. |
| 20 | Cablejointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm as in repairs complete all as specified and as directed. |
| 21 | Air break, gang operated switch, with current rating 200 Amps, HT, 11000 Volts, triple pole mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level as in repairs complete allas specified and as directed. |
| 22 | Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, \"two in series\" assembly for tension with cast aluminium, 4 U bolt tension hardware andtension clamps for conductors, working pressure 11000 volts as in repairs complete all as specified and as directed. |
| 23 | Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp 1100 Volts rating as in repairs complte all as specified and as directed |
| 24 | Supply and laying Synthetic rubber insulated mat 2 mm thick for voltage 11 KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of size 2mtrx1mtr as in repairs complete all as specified and as directed. |
| 25 | Supply and laying Synthetic rubber insulated mat 2.5 mm thick for voltage 11 KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of size 2mtrx1mtr as in repairs complete all as specified and as directed. |
| 26 | Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size |
| 27 | Removing of old earthing materials and taken on credit and provision of new earthing complete with galvanised iron earth plate electrode 600mm X600mm X minimum 6mm thick, with and including earthing of 25mm x 4mm GI strip protected by 40mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directlyin ground vertically to a depth not lessthan2.25 metres below ground level with top edge of the earth plateat a depth not less than1.5 metres belowgroundlevel, connectedto earth leadasdescribedhere-in-beforebymeansofbolts,nuts, washers and checknuts made out ofgalvanised iron or mild steel, earthingleadprotectedby asdescribedhere-in-beforeand connected to main switch board or main control board or electric poleall asshownonelectricalplate No.3of MES Sch Part-Iincluding necessaryearth work and excavation in any type ofsoil,plain cementconcrete1:3:6,typeC1 chamber,reinforcedcement concretecover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm diaTMT barsat140mmcentreto centrebothways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugsincluding testing complete all as specified and as directed. |
| 28 | Dismantling and taking down the unserviceable starter and supply and fix submerssible pump controller suitable for operation on three phase, 415 volts, 50 Hz of capacity upto 10 HP complete all as specified and as directed.Make : Cutler Hamme/L&T |
| 29 | Taking down the unserviceable cable and supply and fix submerssible cable, PVC insulated and sheathed, flat, 3 core 4 sqmm, 1100 volts grade with multi stranded copper conductor from starter to submerssible pump complete all as specified and as directed. |
| 30 | Cast iron sluice valve suitable for 200mm bore of pipe with flanged ends drilled with holes, Class PN 1.6 (conforming to IS 14846)with brass spindle and checknut, rubber gasket 3mm thick, nut, bolts and washers, necessary machining works as in repairs complete all as specified and as directed. |
| 31 | Supply only Sodium Hypochlorite solution with 10% concentration suitable to use in Chlorine Dosing Plant complete allas specified and as directed. |