Construction Of 02 Nos Oxygen Manifolds Space At Gb Pant Hospital Aniims Port Blair , GB Pant Hospital, Port Blair-Andaman And Nicobar Islands

Andaman And Nicobar Islands Medical Education and Research Society-ANIMERS has published Construction Of 02 Nos Oxygen Manifolds Space At Gb Pant Hospital Aniims Port Blair . Submission Date for this Tender is 26-07-2021. Building Work Tenders in GB Pant Hospital, Port Blair Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

28561296
Construction Of 02 Nos Oxygen Manifolds Space At Gb Pant Hospital Aniims Port Blair
Open Tender
Indian
Andaman And Nicobar Islands
GB Pant Hospital, Port Blair
26-07-2021

Tender Details

Construction Of 02 Nos Oxygen Manifolds Space At Gb Pant Hospital Aniims Port Blair

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 7.50 Lakhs /-

BOQ Items

Name of Work: Construction of 02 Nos. Oxygen manifolds space at G.B.Pant Hospital, ANIIMS, Port Blair.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2All kinds of soil.
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
51:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources).
61:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
7Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, ifnishing and reinforcement- All work up to plinth level :
81:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived fromnatural sources: 3 graded stone aggregate 20 mm nominalsize derived from natural sources).
9Reinforced cement concrete work in walls (any thickness), including attachedpilasters,buttresses,plinthandstring courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement
101:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources).
11Reinforcedcementconcreteworkinbeams,suspended floors,roofshaving slopeup to 15°landings,balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement,with 1:1.5:3 (1cement: 1.5coarsesand (zone-III)derivedfromnaturalsources: 3gradedstone aggregate 20mm nominalsize derivedfrom natural sources).
12Centering and shuttering including strutting, propping etc. and removal of form for
13Foundations, footings, bases of columns, etc. for mass concrete
14Lintels, beams, plinth beams, girders, bressumers and cantilevers
15Columns, Pillars, Piers, Abutments, Posts and Struts
16Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
17Thermo-Mechanically Treated bars of grade Fe-500D or more.
18Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
19Electric resistance or induction butt welded tubes
2052 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer"s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
21Providing and fixing glass strips in joints of terrazo/ cement concrete floors.
2240 mm wide and 4 mm thickbes
23Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
24Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
25Ridges plain (500 - 600mm)
2612 mm cement plaster of mix :
271:4 (1 cement: 4 fine sand)
28Finishing walls with Acrylic Smooth exterior paint of required shade :
29New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
30Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :
31Two or more coats on new work
32Providing and laying hollow cement concrete block walling 150mm thick consisting of hollow blocks of size 400x150x200mm of mix 1:3:6 (1 cement, 3 coarse sand and 6 graded stone aggregate 10mm nominal and down size) laid in cement mortar 1:6 (1 cement and 6 coarse sand) upto five floor level.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail