Construction Of G 3 Storied Peb Qtr For Accomodation Of Family Of Police Personal Of 16 Unit / 1 Bldg At 10Th Apbn Complex, Kahilipara Under Mpf Scheme 2014-15 Construction Of G 3 Storied Peb Qtr For Accomodation Of Family Of Police Personal Of 16 Unit, 10th APBn Complex, Kahilipara-Assam

Assam Police Housing Corporation Ltd has published Construction Of G 3 Storied Peb Qtr For Accomodation Of Family Of Police Personal Of 16 Unit / 1 Bldg At 10Th Apbn Complex, Kahilipara Under Mpf Scheme 2014-15 Construction Of G 3 Storied Peb Qtr For Accomodation Of Family Of Police Personal Of 16 Unit. Submission Date for this Tender is 04-08-2021. PEB Tenders in 10th APBn Complex, Kahilipara Assam. Bidders can get complete Tender details and download the document.




Tender Notice

28558036
Construction Of G 3 Storied Peb Qtr For Accomodation Of Family Of Police Personal Of 16 Unit / 1 Bldg At 10Th Apbn Complex, Kahilipara Under Mpf Scheme 2014-15 Construction Of G 3 Storied Peb Qtr For Accomodation Of Family Of Police Personal Of 16 Unit
Open Tender
Indian
Assam
10th APBn Complex, Kahilipara
04-08-2021

Tender Details

Construction Of G 3 Storied Peb Qtr For Accomodation Of Family Of Police Personal Of 16 Unit / 1 Bldg At 10Th Apbn Complex, Kahilipara Under Mpf Scheme 2014-15 Construction Of G 3 Storied Peb Qtr For Accomodation Of Family Of Police Personal Of 16 Unit / 1 Bldg At 10Th Apbn Complex, Kahilipara Under Mpf Scheme 2014-15

Key Value

Document Fees
INR 15000 /-
EMD
INR 653476.0 /-
Tender Value
INR 3.26 Crore /-

BOQ Items

Name of Work: Construction of G+3 Storied PEB Quarter for accomodation of family of Police Personnel of 16 unit/1 Bldg. at 10th APBn. Complex, Kahilipara under MPF Scheme 2014-15.
Sl. No. Item Description
1EARTHWORK IN EXCAVATION:Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground levela) In ordinary soil
2Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.(b) With hill sand obtained by truck carriage loading and unloading, and carriage to the site of work.
3Raising low site around the building with approved soil obtained from outside by truck carraige including breaking clods, dressing etc complete including paying necessary forest royelty , sales, tax, land compensation, municipal gate fees, if any monopoly duty etc, (a) WithinGuwahati city only
4PLAIN CEMENT CONCRETE WORKS: Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(b) In prop 1cement: 4 sand :8 coarse aggregate by volume
5Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
6REINFORCED CEMENT CONCRETE WORKS: Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine. (A) In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser. c) M25 grade concrete
7(B)In super structure from plinth level up to 1st floor level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser. c) M25 grade concrete
8Extra over item Nos. 2.2.1 (I) (B),above for each subsequent floor or part thereof above the 1st floor level.(B)In super structure from 1st Floor to 2nd Floor level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser. c) M25 grade concrete
9(B)In super structure from 2nd Floor to 3rd Floor level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser. c) M25 grade concrete
10(B)In super structure from 3rd floor to roof level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser. c) M25 grade concrete
11TIMBER SHUTTERING (FORMWORK): Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
12Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank
13Vertical Surfaces such as walls. (i)Using 25mm thick plank
14PLYBOARD SHUTTERING (FORMWORK): Plinth level to 1st floor level Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Sides and Sofits of Beams, beam hauchings, cantilever girders, bressumers, lintels and horizontal tiles (a) For depth not exceeding 1.0 M
15Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
16Vertical Surfaces such as walls (any thickness)
171st floor level to 2nd Floor Sides and Sofits of Beams, beam hauchings, cantilever girders, bressumers, lintels and horizontal tiles. (a) For depth not exceeding 1.0 M
18Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
19Vertical Surfaces such as walls (any thickness)
202nd floor level to 3rd Floor Sides and Sofits of Beams, beam hauchings, cantilever girders, bressumers, lintels and horizontal tiles. (a) For depth not exceeding 1.0 M
21Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
22Vertical Surfaces such as walls (any thickness)
233rd floor level to Roof Level Sides and Sofits of Beams, beam hauchings, cantilever girders, bressumers, lintels and horizontal tiles. (a) For depth not exceeding 1.0 M
24Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
25Vertical Surfaces such as walls (any thickness)
26MASONARY WORK: Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete. (a).Brick on flat soling.
27Brick work in cement morter with 1st class brick including racking out jointsand curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary. (c) In proportion 1:5.
28AUTOCLAVED AERATED CONCRETE BLOCK Superlight Weight Autoclaved Aerated concrete block using Grade-IAAC block of compressive strength 40kg/cm2 having drydensity 550 to 650 kg/cum conforming to IS-2185 pt-3 or pt-4 in cement morter of prop 1:4 including racking out joints and curing complete as specified & directed (ii) In superstructure above plinth level up to 1st floor level.
29Extra for concrete block wall for each subsequent floor or part thereof above the 1st floor level. 1st floor to 2nd Level. (a) 150 mm thick block wall
302nd floor to 3rd Level. (b) 150 mm thick block wall
313rd to Roof Level. (c) 150 mm thick block wall
32FLOORING AND FLOOR FINISH: Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).a) Normal range Somany/ Orient/Nitco/Asian Make ii) Of size 200mmx300mm and above
33A) ONFLOOR Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base ofcement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed.(Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make ii) Of size 600mmx600mm and above
34KOTA STONE SLAB / SAND STONE FLOORING: Kota stone slab of 18 mm thick in riser of steps, skirting, dado and pillars laid with 10mm thickcement plaster 1:3 (1 cement : 3 coarse sand)and jointedwith grey cement slurry mixed with pigment to match theshade oftheslabsincludingrubbing and polishing complete.(1) 550mm x 550mm
35Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. (A) CERAMIC ii)Executive range-1 (Sizes 400 mm x 400mm and abov
36PLASTERING AND HERITAGE FINISHES: 10 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.A) On rough side c) In cement mortar 1:5
37B) On fair side c) In cement mortar 1:5
38From 1st floor level to second floor level A) On rough side c) In cement mortar 1:5
39B) On fair side c) In cement mortar 1:5
40From second floor level to third floor level A) On rough side c) In cement mortar 1:5
41B) On fair side c) In cement mortar 1:5
42From third floor to roof level A) On rough side c) In cement mortar 1:5
43B) On fair side c) In cement mortar 1:5
44Ceiling with Exposed Metal (G.I.) Frame work with E-Grid - 2430: Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm . Using 4mm/6mm thick High Pressure Steam Cured Non Asbestos Fibre CementBoard as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm/1200mmx600mm grid, all complete as per the drawing & directions of engineer-in-charge. (A) Standard Ceilings of Everest make or equivalent as directed by the departement. (i) Using 4 mm thick FC Board
45ROOFING: Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) Dyna roof/Wonder Roof/JSW Steel/Spectrum or equivalent as directed by the department. (i)0.40 mm thick
46Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross brands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frame(chowkath)with necessary hinges, screws, bolts etc as specified and directed at all levels (Door fixures and fittings to be measured and paid seperately.) (a) 30mm thick
47GRILLS: Providing, fitting and fixingM.S.grillof required pattern for windows/ clerestory windows/ openingwith M.S. flatsat required spacingin frame all round,squre or round M.S.bars with round headed bolts and nuts or screws. II .Ornamental Grill (c) Fixed to Brickwork/P.C.C/R.C.C.
48WINDOWS: Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections having thickness atleast 1.9mm of approved brand (HINDALCO/JINDAL/BHAGWATI SAI (with proof of purchase of ingot from primary producer)/Other equivalent without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (a) 2 Track Sliding Window (i) 6mm clear glass
49PAINTING: Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)
50Wall painting (two coats) with acrylic emulsion paint approvedbrand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Acrylic Emulsion Paint approvedbrand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
51Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.
52b) Finishing wall with water proofing cement paint of approvedbrand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
53Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
54Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. b). High gloss(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
55DOOR AND WINDOW FITTINGS: Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.(bright natural matt & satin finished ). a) Sliding door bolts i) 300mm x 16mm
56b) Tower bolts iii) 200mm x 10mm
57c)Door handles iii) 150mm
58d) Mortice lock vertical type (ii)75mm
59e)Butt Hinge (i)125mm x 50mm x 2.5mm
60(f) Flush bolts (i) 250mm x 20mm x 4mm
61g) Door stopper with rubber stopper
62STEEL AND IRON WORKS: Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars
63DOOR FRAMES: Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately). (i) Size 90mm x 60mm (Single rebate)
64PEB STRUCTURE:-Designing including vetting of design, fabrication, supplying, erection and installation / fixing in position of Pre-Engineered building G+3. Complete as per specifications approved drawings or instruction of the consultant architect. Pre-engineered Building" Super structure with structural steel work riveted , bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a primary coat of approved steel primer & epoxy painting two or more coats including all holding down bolts, baseplates, gussetplates, nuts,bolts, washers, packings, rivets etc. complete. along with attachment / provision for fixing E&M, OHE and S&T equipments in the building steel roof structures.Work to include all intermediate stages of activities not defined herein, but otherwise implied for total completion of work.The rate shall be inclusive of cost of all the materials, factory fabrication, loading,transportation,unloadingatsite,erection,fixinginposition, welding, grinding etc.complete. Thegaps betweenbase plates/ other gapswillbefilledupwith‘ForceRock’Chemical.Theratewillbe inclusiveofdesigningofthestructurewithstructuresteeltakinginto considerationthe load of total 04storeys i.e. G+3 building and vetting will be got done by the contractor within 10 days of award of work from reputed instituteslike IITs/NITs/Govt. Engineering Colleges. Charges of designing & vetting of steel structure will be included in the quoted & accepted rates, nothing extra will be paid on this account. Pre-engineered Building" Super structure with structural steel work will be designed taking into consideration all loads, pressures, wind pressures,localconditions,relevantearthquakezone,typeanduseof building, as per the standards, codes of practices etc. complete. Accessories that are required to be embedded in concrete work by other agencies are included in the rate quoted by the tenderer
65MACHINE DRIVEN PILES: Providing cast in-situ machine driven reinforced cement concrete piles of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings including using of Bentonite solution. (Reinforcement to be measured and paid seperately as per item no. 21.4.1) C) UNIFORM PILE (II) Concrete Grade M25 iv) Pile dia 400 mm
66Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc) (B) TMT bar of other ISI marked (From Secondary producer)
67FIRE FIGHTING: HYDRANT SYSTEM: Providing,Fixing, testing &Commissioning of Single Headed Gun Metal ISI Marked oblique pattern Hydrant Landing Valve with 80 mm dia, flanged inlet & 63 mm dia instantaneous type female outlet complete with cap and chain, twist release lug and all accessories as per IS:5290-19833 (Type-"A") and specifications complete as reequired . (MAKE:ESSEL/WINCO/NEWAGE)
68Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE)a)200 mm dia
69Supplying & Fixing Cast iron body Non Return valves complete with matching flanges, rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd. (Make:Koley/Kalpana/Audco)(a) 150 mm dia
70Providing ,Fixing,Testing & Commissioning of G.M. Stop Valve ISI Marked screwed type tested to 30Kg/cm2 pressure as per IS:778-1984 of following sizes complete as reqd.(a)50 mm dia
71Providing ,erection,Testing & Commissioning of Pressure Switch (MAKE:INDFOSS)
72Supplying, Installation, Testing & Commissioning of First Aid Hose reel drawn with 30 Mtrs. Long rubber hose and G.M shut off nozzle, 25mm dia Gate valve, Union pipe complete set confirming to IS: 884.
73Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI Mark, and CO2 Cylinder will be confirming to IS: 4947 with ISI Mark, Powder will be confirming to IS: 2878 with ISI Mark (Extinguisher will be TROLLEY MOUNTED)(25 KG) BRAND : FIRESTOP / FIREND / FIRE SHIELD
74Providing AUTOGLOW Signages in Block / Small Letters of Specified Sizes: a) Emergency exit size: 4" X 12"
75b) Fire Hydrant: 4" X 12"
76c) "DCP" Extinguisher: 8" X 8"
77d) "CO2" Extinguisher: 8" x 8"
78e) In case of Fire, do not use lift, use staircase: 8" x 8"
79Supply, Installation, Testing and Commissioning of Cast Iron 2 Way Fire Brigade Inlet as per IS: 904 having 63 mm dia inlet with blank cap and chain with necessary fittings, flanges, nut bolts etc.
80Providing, Fixing, Testing and commissioning of Electric driven main fire pump (Terrace Pump) suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal, centrifugal, back pullout pump to ensure a minimum pressure of 3.5 kg/cm² at highest and farthest outlet at specified flow of 900 lpm at 40 m. head conforming to IS standards. b) Squirrel cage induction motor with suitable HP with synchronous speed 1500/2900 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. c) Common Base plat for Pump and motor and coupling, coupling guard and other accessories as required for complete installation of pump set. d) Suitable cement concrete foundation with cementconcreteplaster complete with anti-vibration arrangement.
81Supplying, installing, testing and commissioning of Control Panel suitable for automatic operation of fire fighting pumps consisting. (a) Necessary cabling, wiring, earthing from panel to individual equipment shall be included in the quoted price. (b) Facility for more selections i.e auto or manual. (c) Protection failure and control cabling. (d) interlocking of pressure switch with pumps
82Construction of Sub-grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts & leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2 (including compensation of earth ). (Including cost of testing of materials at site and laboratory as directed by the deptt.) b) from Government land
83Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause 401 of MoRTH specifications (with an initial lead of 5 km) (including cost of testing of materials at site and laboratory as directed by the deptt.)(a)Using Grading I material
84Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 30 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and Technical specification clause 1504 of MORD.
85Providing fitting and fixingVitreous china wall hang water closet (European type W.C pan 400mm high)with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately).c) Parryware make i)white (v) Elite S Trap (Cat. No. C0297) (inclusive of seat cover)
86Supplying, fiting and fixing PVC flushing cisternwith all internal fittingswith CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make a) White viii) Tiger (CAt No.C8260)
87Providing vitreous China wall hang wash basin with CP brass waste coupling of standard pattern, C.P. brass chain with plug, PVC waste pipe including painting of fittings and brackets , cutting and making good the walls and slabs wherever required. (Pillar cock,stop cock, waste coupling are to be paid separately) (B) Hindware Make (a) White (ii) Cute (Cat No. 10053)
88Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
89Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. (i) Jaquar Make (a) Continental (Cat.No.ACN-1331N)
90Providing, fitting and fixingCP towel ring of Jaquar make complete as specified and directed (b) Sona make(i) Towel ring round (Cat.No.TR-06051)
91Providing, fitting and fixing CP toilet paper holder of Jaquar make complete as specified and directed (d) Sona make(i) Super (Cat. No.AL-1001)
92Providing, fitting and fixing CP Waste Coupling ( half thread HT and Full Thread FT) complete as directed and specified. (b) Sona (i)Rupa 32mm (HT/ FT) (Cat.No.WS-0801)
93Providing, fitting and fixing CP bottle trap J type with outlet pipe and wall flange of following size (b) Sona make for basin etc. complete as directed and specified ii) Bottle trap Indian 40 mm (Cat. No. BT- 0752)
94Supplying, fitting and fixing C.P. bib cock 15 mm dia of approved brand directed and specified. Iv) Agmeco brand (i) Bib Cock without Flange CAT No.CC 00204/CAT No.CN 00204
95Supplying and fitting, fixingChrome plated (CP) stop cock of approved brand of size as mentioned below and directed and specified (G.I. and CP pipes will be measured and paid separately) IV) Sona (a) 15mm dia Stop cock male-female /Angle stop cock
96Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. i) SONA make (b) Heavy type
97Supplying, fitting and fixing Chrome Plated (C.P.)divertor of approved brand complete as directed. Jaquar makea)Continental/ Clarion - 4-way divertor for concealed fitting with built in non return valves with divertor handle Cat No.421
98Providing fitting & fixingstainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipeetc. complete includingpainting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately(B) Nirali (iii) Glister Small (Bowl Size - 410 x 330 x 150) Glossy
99Supplying fitting and fixing overhead adjustable Chrome Plated (C.P.) spray shower 15mm dia. of Sona make with wall flange as directed and specified.(pipes will be measured and paid separately)Jaquar make a) Continental (i) Shower ram 190mm long light body with wall flange
100Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes 2000 Lt capacity (b)Polycon make
101Labour for erectingand placing PCVC Tank over the stagging up to a height of 5.00m complete as directed.(b) 1500 litre capacity
102Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISIapproved including joining ,fitting and fixing wiyh clamps etc.as necessary completeat all levels including below G.L as directed and specified.(Soil + Waste + Rain Water) a) In exposed surfaces or in trenches. (ii) 75mm dia.
103(ii) 110mm dia.
104b) Concealed by chiselling or breaking brick wall/C.C./R.C.Cand making good to the damages. (ii) 110mm dia.
105(iv) 75mm dia.
106(vi) 50mm dia
107Providing fitting and fixing PVC cowel of ISI make completeas directed and specified. (ii) 110mm dia. PVC cowel of ISI make
108Providing fiting & fixingC.I. Grating to the floors complete asdirected and specified. (a) 110mm dia
109(b) 75mm dia
110Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories) (i) exposed on wall & Terrace (FOR DOMESTIC & HOT WATER) (b) 20 mm OD
111(c) 25 mm OD
112(d) 32 mm OD
113(e) 40 mm OD
114(f) 50 mm OD
115(g) 65 mm OD
116(ii) Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to damages (FOR DOMESTIC & HOT WATER) (a) 15 mm OD
117(b) 20 mm OD
118(c) 25 mm OD
119Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed C) CPVC pipe with CPVC fittings FOR EXTERNAL USE (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe) v) 32 mm(OD) diameter
120v) 40 mm(OD) diameter
121vi) 50mm(OD) diameter
122Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Makeas specified and directed. a) 50mm dia
123b) 40 mm dia.
124c) 25 mm dia.
125Supplying and fitting ball valve as specified and directed. a) 25 mm dia. (gun metal)
126Supplyingfitting and fixing G.I. Foot valve with strainer including cutting necessary threads to pipes. a) 50 mm dia (Heavy type)
127Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes. 2000 Lt capacity. (a)Sintex make
128Labour for erectingand placing PCVC Tank over the stagging up to a height of 5.00m complete as directed. (a) 2000 litre capacity
129Labour for erectingand placing PCVCTankover the stagging of 5.00m up to 8.00m complete as directed. (a) 2000 litre capacity
130SEPTIC TANK: Providing fitting & installational at site BIO= Septic Tanks for UP TO 100 users as per specification provided by the department
131Labour for sinking tube well with 40mm (internal) dia G.I. Pipes up to having strata, having potable water including fitting and fixing strainer hand pump and other accessories as directed complete as in any soil.
132Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container(container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).
133Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. vi) Bore hole of 200mm diameter
134Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. G.I. pipe. a) TATA / SAIL (Medium) socket should be welded to the pipes. vi) 150mm diameter
135Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. A) G.I. Pipe. a) TATA / SAIL (Medium)socket should be welded to the pipes. iv) 50mm diameter
136Supplyingfitting and fixing ISI approved PVC filter 3.00 metre long. ii) 50mm diameter
137Supplyingfitting and fixing check valve (non return valve) including thread to pipes. iv) 50mm diameter
138Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
139Flushing, clearing, washing and watering of the tube well
140Providing & erecting open well type horizontal mono block pump set withstainless steel body having following specification [D] For 5 HP 3 phase open well horizontal mono block pump set suitable for 1350 LPM to 310 LPM @ 10 to 42 Mtr head suitable for 50/65 mm dia delivery pipe (Cat.I)
141Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: Non Sor 150 x 100 mm size P type Non Sor
142Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 60x60 cm
143Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885
144Supplying and fixing C.I. cover without frame for manholes : 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg
145Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg 300 x 300 mm
146Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :As per DSR - 2016 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
147Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
148Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : For Drainage 150 mm dia. R.C.C. pipe
149200 mm dia. R.C.C. pipe
150Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : For Storm Water 150 mm dia. R.C.C. pipe
151300 mm dia. R.C.C. pipe
152Construction of Percolation well as per below detail.Making of 12" size bore in ground by machine at the site shown up to 200 ft with or up to water level all development and testing the same for specified percolation rate etc comp as directed & as per detail specifications. Providing and lowering 6" Dia PVC ISI marked Heavy duty stainer pipe plain or slotted 6 kg/cm sq capacity in bore as directed & as per detail specification incl.all taxes etc comp as direction.Gravel packing of suitable size from bottom of bore to ground level as directed as per detail specification.Mud pit arrangement if necessary etc comp as direction. Air compressor work making top line arrangement. Providing, Supplying, laying and lowering and jointing ISI mark 6" Dia rigid unplasticised standard length 6 kg/cm sq PVC pipe suitable for portable water with including all taxes with jointing material etc comp as dire and detail specifications.Carting of surplus earth lime, murrum, building rubbish earth manure or sludge and exacavated rock and fly ash etc. up to 5 km lead incl. Loading & unloading the same.
153Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail