Repairs To Sewage Line Septic Tank And Cleaning Of Sewage Line At Arty Centre Under Ge Nasik Road. As Per Tender Documents

Tender Notice

28545653
Corrigendum : Repairs To Sewage Line Septic Tank And Cleaning Of Sewage Line At Arty Centre Under Ge Nasik Road. As Per Tender Documents
Indian
Maharashtra
06-08-2021
13-08-2021
16-08-2021

Tender Details

Repairs To Sewage Line Septic Tank And Cleaning Of Sewage Line At Arty Centre Under Ge Nasik Road. As Per Tender Documents

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.00 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work: REPAIRS TO SEWAGE LINE SEPTIC TANKS AND CLEANING OF SEWAGE LINE AT ARTY CENTRE UNDER GE NASIK ROAD
Sl. No. Item Description
1Excavation in trenches not exc 1.5m in width and not exc 1.5 in depth for foundation and getting out in any type soil including pipe lines
2All as per item No 1 above but depth exe 1.5 mtr and not exe.3 mtr
3Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soil.
4Removing excavated materialsto a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point
5Demolition of RCC in cover slab
6Demolition of brick work built in cement mortar (including coping)
7Demolition of breaking updrain pipes of RCC or salt glazed ware set in CM 300mm dia.
8All as per item No 7 above but Internal dia of pipe 200 mm
9All as per item No 7 above but Internal dia of pipe 150 mm
10Demolition of Cement Concrete of any description in ground floor & paving n.exc. 15 cm thick(below or above ground level)
11Taking down cement plaster of any description on brick or stone walls or concrete surfaces etc. incl raking out joints, hacking for key scrubbing down with water etc
12M&L cement concrete type C-21:3:6 ( 40 mm graded aggregate) as in foundation, filling and mass concrete.
13M&L PCC 1:2:4 type B2 as in surface channels and drains & benching of manholes and finishing even and smooth with out using extra cement.
14M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in coping
15M&L pre cast cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) asin manhole cover slabs set in cm 1:6 all s specified & directed
16M&L mild steelTMT bars 8mm dia cut to length bent to shape required and binding with ms wire anealed not less than 0.9mm dia, complete all as spacified and directed.
17M&L for brick work with fly ash brick straight or curved on plan exc. 6 mtr mean radius, built in CM 1:6 with old size bricks.
18All as per item No 17 above but except material.
19S&F MS rungs cut to length bend shape & embeded in concrete
20S&F reinforced concrete pipe, class NP2 laid and jointedcomplete with collers 300mm bore of pipe
21All as per item No 20.00 above but 200 mm bore of pipes
22All as per item No 20.00 above but 150 mm bore of pipes
23M&L for rendering 10mm thick in on fair faces of brick work or concrete surfaces in cement mortar(1:4) finishing even and smooth without using extra cement complete all as specifed and directed
24Taking down 100/75 mm dia CI/PVC and cast soil, waste and vent pipes, in any length with or without ears etc in any position
25S&F PVC(SWR) pipes single socketed 75 mm bore in any length with rubber ring joints fixed to walls and making good.
26S&F PVC(SWR) pipes single socketed 110 mm bore in any length with rubber ring joints fixed to walls and making good.
27S&F PVC (SWR) bends 75 mm bore any radius complete all as specified and directed.
28S&F in repairs of PVC (SWR) bends 110 mm bore any radiuscomplete all as specified and directed.
29S&Fin repairs of PVC(SWR) branch piece,single (single Y) equal or unequal 75 mm bore with access door all as specified and directed.
30S&Fin repairs of PVC(SWR) branch piece,single (single Y) equal or unequal 110 mm bore with access door all as specified and directed.
31S&F in repairs ofPVC (SWR) branch piece, double (double Y) equal or unequal 75 mm bore with access door all as specified and directed.
32S&F in repairs of PVC (SWR) branch piece, double (double Y) equal or unequal 110 mm bore with access door all as specified and directed.
33S&F in repairs ofPVC (SWR) junction (single "T") equal or unequal, bore 75 mm with access door, complete all as specified and directed.
34S&F in repairs ofPVC (SWR) junction (single "T") equal or unequal, bore 110 mm with access door, complete all as specified and directed.
35S&F in repairs PVC(SWR) floor trap 75 mm dia,plain with grating including jointing with solvent cement and making good
36S&F for PVC(SWR) 110 mm diavent cowl
37Cleaning of manholes of any size taking outsludge , effluent ,sand,, grit, ash, rags, fibre and string material etc complete and disposed as directed by Engr in-Charge
38Cleaning of septic tank by taking out of sludge, water, effluent etc and removing all loose sedinented sand sludge, grit, ash, rags fibre and stirringly material ans its removal to sewage treatment plant or as directed and emptying completely depth exc 1.00 M and n.ex 6.00 M all as directed by Engineer-in-Charge
39Cleaning of blocked WCs /nahani traps/floor traps/ urinalsof any dia by rodding only.
40Cleaning of existing sewage line of any diaby roding including removal of sludge andtaking out sewage water where required and finally flushing with clean water & The length will be measured from the first manhole to last blocked manhole including manhole in between.
41Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing(, removing serviceable tiles, to stone and rubbish off the premises
42M&L Non -skid coloured ceramic joint free tiles 7 to 8mm thick (square/retangular) tiles exc 0.06 Sqm but n.exc 0.11 Sqm each, in floors etc. laid over and including 15mm thick cement mortar screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match.
43S & F in repair Vitreous China water closet squatting pan, "Orrisa" pattern, size 580 x 440 mm white, with integral foot rests and P trap (excluding flushing cistern and flush pipe) complete including provision of lime concrete bedding.
44S & F in repairs 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including flush pipe and brackets fixed .
45S & F in repairs Vitreous china wash down water closet (pedestal pattern), white including plastic water closetseat, closed pattern with flat bottom , and cover and mild steel choromium plated or aluminium hinging device complete fixed.
46S & F in repairs hand shower (Health faucet) 1 mtr PVC tube with wall hook (CP) complete all as specified and directed.
47S & F in repairs stop valve, 15mm bore dia PTMT of any colour high pressure screwed for iron pipe and fixed (Minimum weight 90 gms) complete all as specified and directed.
48S & F in repairs PVC connections 15mm size with PTMT nuts of length 450mm
49Dismantling of stone slabs & tiles of any description or thickness (except ceramic tiles) in floors, aprons etc laid bedded & pointed in any mortar complete all as specified and directed.
50M & L 75mm thick cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) in sub base of flooring/hard standing.
51M & L for rubber moulded machine pressed precast interlocking paver block with gray cement any shape and size confirming to IS 15658-2006 of 60mm thickness, M-25 grade laid on 30mm thick stone dust cushioning laid dry to the profile complete all as specified and directed.
52M & L for Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concret 1:4:8 type D2 for 150 mm dia pipe
53M & L for Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concret 1:4:8 type D2 for 200 mm dia pipe
54M & L for Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concret 1:4:8 type D2 for 300 mm dia pipe
55NOTE : - AMOUNT OF SCHEDULE OF CREDITRS. 34,503.00WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2021 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail