| 1 | Dismantling/taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling rosees, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc, complete all as specified and directed. |
| 2 | Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic,medium grade PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flushboxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paintincluding modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed.NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately.2. All chases will be cut by chase cutter only. |
| 3 | Description all as per item No 2.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed. |
| 4 | Description all as per item No 2.00 here in before but for socket out let point 5 Amps on independentboard complete all as specified and directed. |
| 5 | Description all as per item No 2.00 above but point wiring for one socket out let 15&5 Amps (independent) controlled by one switchwith using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed. |
| 6 | Material and labour for point wiring in existing conduit using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSHPVC insulated and unsheathed stranded cable drawn through inexisting non metallic/mettalicmedium grade concealed/Surface conduit and including replacement of its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paintincluding modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathedFRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/Bell Point controlled by one switch complete all as specified and as directed.NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately.2. All chases will be cut by chase cutter only. |
| 7 | Description all as per item No 6.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed. |
| 8 | Description all as per item No 6.00 here in before but for socket out let point 5 Amps on independentboard complete all as specified and directed. |
| 9 | Description all as per item No 6.00 here in before but point wiring for onesocket out let 15&5 Amps (independent) controlled by one switchwith using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed. |
| 10 | Supply and fixing in repair modular switches, one way,6 amps one module, 230V, 50 Hz supply, complete all as specified and directed. |
| 11 | Supply and fix in repair modularswitches, oneway, 20 Amps, one module, 230 volt , AC supply, complete all as specified and directed. |
| 12 | Supply and fixing in repair modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed. |
| 13 | Supply and fixing in repairmodular socket outlet 16 amps,2/3 pin , combined 2 module, complete all as specified and directed. |
| 14 | Supply and fixing in repairfan regulator / Dimmer step type one module / 2 module, 120w 230 Volts, 50 Hz, AC complete all as specified and directed. |
| 15 | Supply and fixing in repair modular switches, bell push,6 amps one module, 230V, 50 Hz supply, complete all as specified and directed. |
| 16 | Supply and fixing in repair modular blanking plate 1 module complete all as specified and directed. |
| 17 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm diaand its fittings including all tees, bell mouth and fixing accessories such as couplers ,saddlers, pipe hooks etcconcealed on wall/ceilingand including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existing for one light/fan/Bell point controlled by one switch.NOTE: - Switch, socket and fan regulators to be measured and paid for separately . |
| 18 | Description all as per item No 17.00 here in before but for socket out let point 5 Amps on same board,complete all as specified and directed. |
| 19 | Description all as per item No 17.00 here in before but for socket out let point 5 Amps on independentboard,complete all as specified and directed. |
| 20 | Description all as per item No 17.00 above but with 2.5 Sqmm cable for 3pin 15 Amps switch socket outlet (Power Point), complete all as specified and directed. |
| 21 | Supply and fixing in repair switch piano 5 Amps, flush type, single pole, one way,230 volt , AC supply,ISI Marked, complete all as specified and directed. |
| 22 | Supply and fixing in repairswitch piano 15 Amps flush type one way 230 Volts,50 Hz , AC supply, ISI Marked, complete all as specified and directed. |
| 23 | Supply and fixing in repair bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed. |
| 24 | Supply and fixing in repair socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as speciied and directed. |
| 25 | Supply and fixing in repair socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified and directed. |
| 26 | Supply and fixing in repair ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed. |
| 27 | Supply and fixing in repairfan regulator/ Dimmer electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and directed. |
| 28 | Supply and fixing in repair door bell electric ,ding dong /musical| type, single phase 230 volts, ISI marked complete all as specified and directed. |
| 29 | Supply and fixing in repair lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 30 | Supply and fixingchannel for fixing of LED tube rod, aluminium housing body Double end contact in CRCA body suitable for 18/20 watt LED tube, high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.(Tube rod shall be measured and paid for separately). |
| 31 | Supply and fixing 18 W/ 20W Polycarbonate LED tube light, environment friendly, high efficient, T8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed.NOTE:- Tube rod must be get approved from Engr in charge to check fesibilty i.e. two end contact for fixing in existing LED fittings. |
| 32 | Supply and fixing LED luminaries of capacity 20 watt integrated aluminium batten with including Oppel diffuser complete including removing of unservicable fitting of any type in any position complete all as specified and directed. |
| 33 | Supply and fixing in repair LED luminaries midbay light of capacity 50 to 60 watt , environment friendly , aluminium die cast , IP-65 protected with high power LED as lightin any position complete all as specified and directed. |
| 34 | Supply and fixing decorative surface mounted LED tube light fitting with high efficient diffuser mirror light, aluminium housingin CRCA body suitable and including 10 watt LED tube high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. |
| 35 | Supply and fixing bulk head light fitting, 10 watt, energy efficient withlamp 10 watt with provision of TWO core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting completeincluding disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. |
| 36 | Supply and fixing in repair in replacement bracket for security light made up of 25mm dia suitable for security light, 0.9 metre long GI pipe,light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed. |
| 37 | Supply and fixing LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W eachand having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed. |
| 38 | Supply and fixingLED security light luminaire 45 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W eachand having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed. |
| 39 | Supply and fixingpost top lantern LED 30W , cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessoriesinternally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed. |
| 40 | Supply and fixingLED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W eachand having optical grade polycarbonate lens with 4 hours battery back up all accessories internally pre wired and including connecting up with Two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed. |
| 41 | Supply and fixing recess/ surface mounted LED flat panel 2\" x 2\" with high efficient LEDs and glare free full decorative light fitting, 36 watt, energy efficient provided withincluding LED36 watt withprovision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and completeincluding disconnecting and taking down existing light fitting and removal complete all as specified and directed. |
| 42 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium, stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sqmm 2 core complete all as specified and directed. |
| 43 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium, stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm2 core complete all as specified and directed. |
| 44 | Labour Onlyfor repair/replacement of unserviceable elctrical fitting and fixture and emergent fault rectification in elctrical circuit inclno light , earth leakage, short circuit, neutral break mains /sub mains/internal circuits of existing system of main building / block ,making continious electric supply including carrying out minor repairs etc as required to make system in order / functional by replacing, copper cable , copper thimbles ,glands , earthing wire complete all as specified and directed.as reqd at site by Engr-in-Charge.NOTE: - (a) Items reqd for replacemen such as switchs, sockets for power/light/ fan/ bell/geyser points including security lights complete will be measured and paid under respective items of Sch \"A\". (b) Contractor rep/supervisor will report to MES Service Centrealongwith reqd sufficient skilled/unskilled manpower between 930 Hrs to 1030 Hrs on all working days. for carrying out necessary execution.(c) Contractor will attend emergent nature of work i.e. no light, short circuit after working hours/holiday. The rate of the is deemed to be included in above quated rates.(d) Switch/sockets/regulators all as per sample since being used in existing inner and outer plated box. |
| 45 | Supply only switch piano 5 Amps, flush type, single pole, one way,230 volt , AC supply,ISI Marked, complete all as specified and directed. |
| 46 | Supply onlyswitch piano 15 Amps flush type one way 230 Volts,50 Hz , AC supply, ISI Marked, complete all as specified and directed. |
| 47 | Supply onlybell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed. |
| 48 | Supply only socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as speciied and directed. |
| 49 | Supply only socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified and directed. |
| 50 | Supply onlyceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed. |
| 51 | Supply onlyfan regulator/ Dimmer electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and directed. |
| 52 | Supply only door bell electric ,ding dong /musical| type, single phase 230 volts, ISI marked complete all as specified and directed. |
| 53 | Supply onlylamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 54 | Supply only Fan condenser 2.5 mfd complete all as specified and directed. |
| 55 | Supply onlymodular switches, one way,6 amps one module, 230V, 50 Hz supply, complete all as specified and directed. |
| 56 | Supply only modularswitches, oneway, 20 Amps, one module, 230 volt , AC supply, complete all as specified and directed. |
| 57 | Supply only modular socket outlet 6 amps, 2/3 pin combined two module, 230 volt, complete all as specified and directed. |
| 58 | Supply onlymodular socket outlet 16 amps,2/3 pin , combined two module, complete all as specified and directed. |
| 59 | Supply only fan regulator / Dimmer step type 1 / 2 module, 120w 230 Volts, 50 Hz, AC complete all as specified and directed. |
| 60 | Material and labour for replacement PVC insulated, unsheathed cable 4.00 Sqmm single core 1100 volt grade with multi stranded copper conductor ISI marked complete all as specified and directed. |
| 61 | Material and labour for replacement PVC insulated, unsheathed cable 2.5 Sqmm single core 1100 volt grade with multi stranded copper conductor ISI marked complete all as specified and directed. |
| 62 | Material and labour for replacement of Cable PVC copper conductor flexible twin core 0.75mm complete all as specified and directed. |
| 63 | Supply and fixing in repair sheet metal enclosure SP with two pin and earth plug and socket with one single pole, MCB 32 Amps, \"C\" curve, 240 volts complete all as specified and as directed. |
| 64 | Material and labour for sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 4 sqmm drawnin and including rigid non metallic PVC medium grade 25 mm dia new concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSHof 4.00 sqmm,green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete,all as specified and directed.Note- 3 run of 4.00 sqmmcable with concealed conduct shall be measured as 1 unit. |
| 65 | Material and labour for sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 6sqmm drawnin and including rigid non metallic PVC medium grade 25 mm dia new concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSHof6sqmm,green colourfor earthcontinuity conductor includingtaking down old unserviceable sub main wiringand making good the disturbed surface complete,all as specified and directed.Note- 3 run of 6.00 sqmmcable with concealed conduct shall be measured as 1 unit. |
| 66 | Material and labour for sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 2.50 sqmm drawnin and including rigid non metallic PVC medium grade 25 mm dia new concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSHof 2.50 sqmm,green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete,all as specified and directed.Note- 3 run of 2.5 sqmmcable with concealed conduct shall be measured as 1 unit. |
| 67 | Taking down old unserviceable MCB DBs any type including MCB SP/SPN and removing unserviceable materials incl debris from site and keeping unserviceable DB/MCCB/MCB in safe custody for taking credit complete all as specified and as directed. |
| 68 | Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 250 amps rated bus bar IP 43 protection, with shrouded neutral bar and insulated bus bar and earth link, with and includingMCCB 4 pole Thermal release release type,160 AMPS ,25 KAas incomer and MCB sas out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed. |
| 69 | Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 43 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole Thermal release release type,125AMPS ,25 KAas incomer and MCB sas out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed. |
| 70 | Supply and fixing in repair sheet metal enclosures distribution board for TPN, (MCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 43 protection, with shrouded neutral bar and insulated bus bar and earth link, suitable forMCB 4 poleas incomer and MCB sas out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed. |
| 71 | Supply, installation, testingof SPN distibution board 12 way,double door , IP 43, as per IS 8623including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles complete all as specified and directed. |
| 72 | Supply, installation, testingofSPN distibution board 8 way,double door , IP 43 , as per IS 8623including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles complete all as specified and directed. |
| 73 | Supply, installation, testingof SPN distibution board 4 way,double door , IP 43 , as per IS 8623including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles complete all as specified and directed. |
| 74 | Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, \"B\" curve 6 to 32 Amps, ISI marked complete all as specified and directed. |
| 75 | Supply and fixing in repair MCB single pole and neutral 240 volts, 16 to 32 Amps,10KA, 50 Hz,\"B\" Series complete all as specified and as directed. |
| 76 | Supply and fixing in repair MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, \"B\" Series complete all as specified and as directed. |
| 77 | Supply and fixing in repair MCCB 4 pole Thermal release release type, 240 volts, 50Hz , breaking capacity 25KA, 125 Amps, complete all as specified and as directed. |
| 78 | Supply and fixing in repair MCB four pole, 240 volts, 50Hz , breaking capacity 10KA, 100 Amps, C curve, complete all as specified and as directed. |
| 79 | Supply and fixing in repair MCB four pole, 240 volts, 50Hz , breaking capacity 10KA, 40A to 63 Amps, C curve, complete all as specified and as directed. |
| 80 | Taking out old unserviceable earthing and material & labour for earthing with Galvanised Steel earth plate electrode 60cmx 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers and electrode connections by usingGalvanised Iron wire 4mmas earthing lead(upto terminal point) by means ofbolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm diaGI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6)type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type ofsoil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 ofSSR 1991(Part-I) complete all as specified and as directed by Engineer-in-charge. NOTE: - The rates for earth work, GI protection pipe, funnel, wire wesh, CI cover, etc shall be deemed to beincluding in quoted rates. |
| 81 | Material and labour for Preparing Old surfaces plastered or unplastered on wall surface and applying two coats of white wash including finishing complete all as directed and specified. |
| 82 | Material and labour for Preparing Old surfaces plastered or unplastered on wall surface and applying two coats of applying two coatswith cement base paint in patches on walls surface with including finishing and matching with existing complete all as specified and as directed. |
| 83 | Disconnecting and taking down old existing wall fitting of any description and in any position and Supply and fixing surface mounting type LED round type Decorative ,wall mouting ,brushed nickel with 9W LED capacity B22 Lamp & clear diffuser Oval/ round type with IP 20 Protection including connecting up with two core 0.5 sqmm flexible copper conductor cablecomplete all as specified and directed. |
| 84 | Material and labour for disconnecting all loose wiring / cable in hanging position and Supply and fixing PVC conduit pipe medium duty of Nominal Dia 25mmwith suitable clamps after passing all loose wiring / cable through pipe complete all as specified and directed. |
| 85 | Supply and fixing in repair PVC cable tray / casing capping of size 50mm X 50mmincluding disconnecting all loose wiring / cable in hanging position and clamping them on a tray complete all as specified and directed. |
| 86 | Material and labour for disconnecting all loose wiring / cable in hanging position and supply and fix in repair flexible PVC conduit pipe medium duty of Nominal Dia 20mmwith suitable clamps after passing all loose wiring / cable through pipe complete all as specified and directed. |
| 87 | Supply and fixing House service bracket (hook type completewith 3.0m long G.I. pipe 40mm dia Med.grade, two nos 90 Degreebends. M.S. hook and stay or guy complete all as specified and directed. |
| 88 | Supply and fixingPVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed. |
| 89 | Supply and fixing PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep complete all as specified and directed. |