Gek-43 / 2021-22 Provn Apfc Panel At Various Electric Installations At 14 Gtc Subathu Under Ge Kasauli, SUBATHU-Himachal Pradesh

Military Engineer Services-MES has published Gek-43 / 2021-22 Provn Apfc Panel At Various Electric Installations At 14 Gtc Subathu Under Ge Kasauli. Submission Date for this Tender is 10-08-2021. Electrification Work Tenders in SUBATHU Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

28543613
Corrigendum : Gek-43 / 2021-22 Provn Apfc Panel At Various Electric Installations At 14 Gtc Subathu Under Ge Kasauli
Open Tender
Indian
Himachal Pradesh
SUBATHU
10-08-2021

Tender Details

Gek-43 / 2021-22 Provn Apfc Panel At Various Electric Installations At 14 Gtc Subathu Under Ge Kasauli

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-08-2021
2 04-Aug-2021 CERTAIN AMENDMENTS TO TENDER DOCUMENTS DUE TO ADMINISTRATIVE REASONS Other 10-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 19200.0 /-
Tender Value
INR 9.60 Lakhs /-

BOQ Items

Name of Work: PROVN APFC PANEL AT VARIOUS ELECTRIC INSTALLATIONS AT 14 GTC SUBATHU UNDER GE KASAULI.
Sl. No. Item Description
1Schedule "A" Section - I
2Supplying, fixing, connecting and commissioning and testing of 12 steps Microprocesser based Automatic Power factor improvement static condenser (cap banks) of capacity 300 KVARfor 750 KVA transformer indoor type panel compaly with 10 tank spray base tricationic phosphating treatment process for powder coating painted with RAL 7032& PU foam gasket without mannual pasting,joint less suitable for 1100V grade 3 phase 50 Hz AC supply.fully compartmentalized design, floor mounted,fabricated out of2.00 mm MS sheet ,having plinth of 100 mm front door and back opening having locking arrangement prewired with copper conductor PVC insulated cable/extension strips and connected withsuitable size thimbles/lugs duly suitable chemical treatment including locking arrangement suitable for mounting, with required sheet metal enclosures, thimbles , Fan 8"" (200mm) sweep 230V AC Axial, PVC flexible Cu wire 16 Sqmm stranded red, PVC CU wire 2.5mm dia Strd Flex Blk., PVC CU wire 1.5mm dia Strd Flex Blk, CT shorting terminals, Terminal block 2.5 Sqmmall as specified and directed, and all other electric incoming and outgoing connections with PVC insulated multi stranded copper wire of suitable size and PVC flexible conduit medium quality as required, comprising of following: (a) Bus bar Size: Bus bar of copper of500amps capacity three for phase and one for neutral of appropriate size fixed on insulators. (b) Incoming MCCB : (i) 500 Amp, 36 KA, 3 pole, 1 No (ii) Rotary Handle 630A frame MCCB Var Depth-01 No (iii) R, Y, B Phase indicating lamp-01 No (iv) Ammeter 0-600A CTR:5A 96x96mm-01 No (v) Ammeter Selector switch-01 No (v) Voltmeter 0-500V 96x96mm-01 No. (vi) Voltmeter selector switch- 01 No(vii) CT 15VA 600/5A BPL tape wound class-I - 03 Nos (viii) MCB,6A,SP-06 Nos. (ix) Disconnecting type neutral link 15/30A- 02 Nos. (x) APFC 144x144, 12 Steps, 230V- 01 No (xi) Off-delay timer BCR 240/24V- 01 No (xii) 240 VAC 2NO+2NC control realy- 05 Nos.(xiii) Aux cont. block ( topmtg) 4 NO for FS CR -02 Nos (xiv) Auto/manual selector switch- 01 No (xv) Contact Block 1 NO+1NV -01 No. (c) 50KVAR CAPACITOR BANKS: (I) MCCB 125A TP, 25kA- 05 Nos. (ii) 50 kVAR capacitor duty contactor 240V coil- 05 Nos (iii) 50kVAR ,440V,MPP,3Ph, Heavy duty capacitor cylindrical type- 05 Nos. (iv) ON push button flush- 05 Nos (v) Contact block 1 NO- 05 Nos (vi) Off push button flush red- 05 Nos (vii) Contact block 1 NO+1NC- 05 Nos. (viii) ON indication LED 240V VAC red- 05 Nos.(ix) MCB,6A,SP for control- 05 NOs. (d) 25KVAR CAPACITOR BANKS: (I) MCCB 63A TP, 10kA- 01 Nos. (ii) 25 kVAR capacitor duty contactor 240V coil- 01 Nos (iii) 25kVAR ,440V,MPP,3Ph, Heavy duty capacitor cylindrical type- 01 Nos. (iv) ON push button flush- 01 Nos (v) Contact block 1 NO- 01 Nos (vi) Off push button flush red- 01 Nos (vii) Contact block 1 NO+1NC- 01 Nos. (viii) ON indication LED 240V VAC red- 01 Nos.(ix) MCB,6A,SP for control- 01 NOs. (e) 10KVAR CAPACITOR BANKS: (I) MCB 32A TP, 10kA- 02 Nos. (ii) 10 kVAR capacitor duty contactor 240V coil- 02 Nos (iii) 10kVAR ,440V,MPP,3Ph, Heavy duty capacitor cylindrical type- 02 Nos. (iv) ON push button flush- 02 Nos (v) Contact block 1 NO- 02 Nos (vi) Off push button flush red- 02 Nos (vii) Contact block 1 NO+1NC- 02 Nos. (viii) ON indication LED 240V VAC red- 02 Nos.(ix) MCB,6A,SP for control- 02 NOs. (f) 5KVAR CAPACITOR BANKS: (I) MCB 16A TP, 10kA- 01 Nos. (ii) 5 kVAR capacitor duty contactor 240V coil- 01 Nos (iii) 5 kVAR ,440V,MPP,3Ph, Heavy duty capacitor cylindrical type- 01 Nos. (iv) ON push button flush- 01 Nos (v) Contact block 1 NO- 01 Nos (vi) Off push button flush red- 01 Nos (vii) Contact block 1 NO+1NC- 01 Nos. (viii) ON indication LED 240V VAC red- 01 Nos.(ix) MCB,6A,SP for control- 01 NOs.( Note :- Old APFC Panel will be deposited in MES Store Yard) Note for item No.1.00 : Panel drawing should be approved by Garrison Engineerbefore placing order.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail