}

Tender Enquiry For In Asset Erdd Of In Asset - 1.0001 Sow- In Asset - 1 ( 05X02x01 Mtrs ) 001 Docking- Vesse, NAVAL DOCKYARD VISAKHAPATNAM-Andhra Pradesh

Indian Navy has published Tender Enquiry For In Asset Erdd Of In Asset - 1.0001 Sow- In Asset - 1 ( 05X02x01 Mtrs ) 001 Docking- Vesse. Submission Date for this Tender is 05-08-2021. Footwears Tenders in NAVAL DOCKYARD VISAKHAPATNAM Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

28542449
Tender Enquiry For In Asset Erdd Of In Asset - 1.0001 Sow- In Asset - 1 ( 05X02x01 Mtrs ) 001 Docking- Vesse
Open Tender
Indian
Andhra Pradesh
Naval Dockyard Visakhapatnam
05-08-2021

Tender Details

Tender Enquiry For In Asset Erdd Of In Asset - 1.0001 Sow- In Asset - 1 ( 05X02x01 Mtrs ) 001 Docking- Vessel To Be Docked In Both Versions. Note 1:- Firms Not To Quote View Docking, Undocking And Dock Blocks Preparation Will Be Done By Navy And The Job Is Required To Be Carried Out In Navy Premises ( I.E Nd ( V ) Slipway ) . 1.0002 002 Hull Cleaning Under Water And Boot Top Area Hp Jet Clean Entire Under Water Area And Boot Top Area ( With A Pressure Not Exceeding 3000 Psi ) Including Ship Side And Remove The Marine Growth / Barnacles Andpresent For Survey ( Approx Weight Of Pontoon - 10 Tons ) . ( A ) U / W Area: 15 Sqm ( B ) Boot Top Area: 5 Sqm 1.0003 002 Hull Cleaning Above Water Area ( A ) Clean The Entire Above Water Area With Hp Jet Washing ( With A Pressure Not Exceeding 3000 Psi ) To Remove Salts And Contaminants From The Surface I.A.W. No 01 / 15 And Present For Survey 1.0004 002 Hull Cleaning Weather Deck ( B ) Clean The Entire Weather Deck Including Fittings Area With Hp Jet Washing ( Not Exceeding 3000 Psi ) To Remove Salts And Contaminants From The Surface. I.A.W. No 01 / 15 And Present For Survey 1.0005 002 Hull Cleaning Tanks ( C ) Manually Clean Internal Tanks I.A.W. No 01 / 15 And Present For Survey. The Tanks Should Be Washed Out With Fresh Water And Soap Water To Remoeve Any Sediment Or Dirt Present In The Tank 1.0006 003 Hull Survey External And Internal Hull Survey. Hull Survey. Carry Out Visual And Hammer Survey / Utg Survey In Accordance With No 19 / 06 Of Under Water Hull, Boot Top, Above Water Hull, Weather Decks And All Internal Tanks Etc, All Stiffeners And Deck Fittings Including Lifting Hooks / Eyes. All Manholes To Be Inspected And Repaired To Ensure Water Tightness, Chalk Impression Test To Be Carried Out. Approx Area: 100 Sqm 1.0007 004 Utg Survey . Quote For Utg Survey Points At U / W Hull, Above Water, Weather Deck And Covering Entire Part Of Hull. 1.0008 005 Steel Renewals Quote For Steel Renewal At Various Locations As Per Survey Report. Note 1:- Quoted Repair Cost Shall Include Cost Of Both Sides Blasted And Primed Grade `A’ Quality Ship Building Steel For Shell And Is 2062 Grade `B’ Quality Steel For Non Structural Works, Renewal Of All Obstructions In Way Of Steel Renewals Including Minor Fittings With Their Foundations, Etc., As Indicated By Survey Team / Rmt, Proving Of The Weld Runs By Non-Destructive Tests And By Hose Test On Completion Of Welding, Pressure Testing And Proving Of Tanks Where Steel Renewal Undertaken Etc. 1.0009 006 Build Ups ( A ) Carry Out Build Ups As Indicated By The Hull Survey Team / Surveyor Approx Size 25X25 Mm-100 1.001 006 Build Ups ( B ) Carry Out Build Ups As Indicated By The Hull Survey Team / Surveyor Approx Size 50X50 Mm-100 1.0011 006 Build Ups ( C ) Carry Out Build Ups As Indicated By The Hull Survey Team / Surveyor Approx Size 100X100 Mm-100 1.0012 007 Draught Marks Draught Marks Corroded / Eaten Away, To Be Renewed And Painted. Both Roman And Numeric. 1.0013 008 Sacrificial Anodes Renew Sacrificial Anodes ( Mk Ii ) Those Consumed More Than 50% Note:- Anodes Navy / Coy Supply. 1.0014 009 Surface Preparation With Grit Blasting Under Water Area Including Boot Top Area Spot Blasting To Sa 2.5 On Paint Damaged Areas / Renewed Plate Areas As Per The Paint Oem Rep Recommendation For Paint Application. 1.0015 009 Surface Preparation With Grit Blasting Under Water Area Including Boot Top Area Sweep Blasting To Sa 1 On Paint Damaged Areas / Renewed Plate Areas As Per The Paint Oem Rep Recommendation For Paint Application. 1.0016 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( A ) 1St Coat: Primer - Penguard Primer - 50 Microns 1.0017 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( B ) 2Nd Coat: Anti Corrosive - Jotacote Universal ( Aluminium ) - 150 Microns 1.0018 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( C ) 3Rd Coat: Anti Corrosive - Jotacote Universal ( Grey ) - 150 Microns 1.0019 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( D ) 4Th Coat: Tie Coat: Safeguard Es - 125 Microns 1.002 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( E ) 5Th Coat: A / F: Sea Quantum Pro U And Spectrum 150 Microns ( Light Red / Dark Red ) 1.0021 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( F ) 6Th Coat: A / F: Sea Quantum Pro U And Spectrum 150 Microns ( Light Red / Dark Red / Black ) 1.0022 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( G ) 7Th Coat: A / F: Seaquantum Specturm ( Black ) - 2 X 150 Microns 1.0023 011 Surface Preparation Above Water Area ( A ) Carry Out Surface Preparation With Mechanical Cleaning On Above Water Area To St 3 Standard Under The Suprvision Of Paint Oem. 1.0024 011 Surface Preparation Above Water Area ( B ) Carry Out Surface Preparation With Mechanical Cleaning On Above Water Area To St 1 Standard Under The Suprvision Of Paint Oem. 1.0025 012 Painting - Jotun Scheme. Above Water Area Paint Above Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( A ) 1St Coat: Penguard Primer - 50 Microns Dft 1.0026 012 Painting - Jotun Scheme. Above Water Area Paint Above Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( B ) 2Nd Coat: Jotamastic ( Grey / Red Brown ) - 125 Microns Dft 1.0027 012 Painting - Jotun Scheme. Above Water Area Paint Above Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( C ) 3Rd Coat: Jotamastic ( Grey / Red Brown ) - 125 Microns Dft 1.0028 012 Painting - Jotun Scheme. Above Water Area Paint Above Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( D ) 4Th Coat: Hard Top Xp Grey - 60 Microns Dft 1.0029 013 Surface Preparation Weather Decks And Fittings ( A ) Carry Out Spot Blasting To Sa 2.5 Standards As Per Survey Report Of Paint Oem For Paint Application For Entire Weather Deck. 1.003 014 Painting - Jotun Scheme Weather Decks And Fittings Paint Weather Decks And Fittings With Following Paint Scheme:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( A ) 1St Coat: Primer - Penguard Primer -50 Microns Dft 1.0031 014 Painting - Jotun Scheme Weather Decks And Fittings Paint Weather Decks And Fittings With Following Paint Scheme:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( B ) 2Nd Coat: Jotamastic 87 Of 200 Microns 1.0032 014 Painting - Jotun Scheme Weather Decks And Fittings Paint Weather Decks And Fittings With Following Paint Scheme:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( C ) 3Rd Coat: Jota Armour Dark Grey Of 800 Microns 1.0033 015 Surface Preparation Internal Tanks ( A ) Carry Out Mechanical Cleaning To St3 Standard At Paint Defective Area / As Survey Report Of Paint Oem For Paint Application. 1.0034 015 Surface Preparation Internal Tanks ( B ) Carry Out Mechanical Cleaning To St1 Standard At Paint Defective Area / As Survey Report Of Paint Oem For Paint Application. 1.0035 016 Painting - Jotun Scheme Paint All Internal Tanks With Following Paint Scheme Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( A ) 1St Coat: Primer - Penguard Primer -50 Microns Dft 1.0036 016 Painting - Jotun Scheme Paint All Internal Tanks With Following Paint Scheme Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( B ) 2Nd Coat: Anticorrosive Balloxy ( Hb Light ) - 150 Microns 1.0037 016 Painting - Jotun Scheme Paint All Internal Tanks With Following Paint Scheme Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( C ) 3Rd Coat: Anticorrosive Balloxy ( Hb Light ) - 150 Microns 1.0038 017 Deck Fitting ( A ) Twin Bollards On Weather Deck Corroded / Thinned / Perished , To Be Repair / Renewal As Per Survey Reports ( Mat. - Ms ) 400Mmx800mmx08mm Base, 600Mmx200mmx08mm U Plate, 250Mmx160mmx06mm Pipes, 400Mmx25mm Stag Horns ( Rods ) 1.0039 017 Deck Fitting ( B ) Ms Cleats On Weather Deck Including Locking Pins Perished / Uprooted To Be Repaired / Renewed ( Mat Ms ) As Per Survey Reports. Mat-Ms. 1.004 017 Deck Fitting Carry Out Load Testing Of Twin Bolllrads ( C ) Load Testing Of Securing Eyes Post Welding ( Test Load To Be Applied 7.5 T, Swl 3.0T ) 1.0041 018 Manhole Cover ( A ) Manhole Cover Neoprene Rubber Joints Perished, To Be Renewed ( Rubber Joint Size: - 520Mm X 760Mm X08 Mm ) 1.0042 018 Manhole Cover ( B ) Manhole Cover Including Coamings Perihsed / Thinned To Be Renewed As Per Survey Report ( Approx Size - 3X18 ) 1.0043 018 Manhole Securing Arrangment C ) Manhole Stud Nut And Bolts With Washers Corroded / Perished To Be Renewed. ( Size Of Stud Bolt -16 Mm X 50Mm Length, 32 Nos On Each Manhole, Mat Ss ) . 1.0044 019 Manhole Cover Handle Of Manhole Covers Corroded / Thinned, To Be Renewed, ( Mat-Ms Rod, 12 Mm Thick 1.0045 020 Apt Air Pressure Test The Following Tanks And Rectify The Defects Any Observed During Pressure Testing And Prove To 0.14 Kg / Cm2. Note:- Apt And Proving Of Those Tanks Wherein Steel Renewal Undertaken As Part Of Steel Renewal Dl. 0003 ( C ) Above Is That Of Firms Liability With No Additional Cost And Those Tanks Where No Steel Renewals Undertaken Only Would Be Considered For Payment As Per The Indicated Rates Under This Dl. Serial. Internal Tank 1.0046 021 D Type Rubber Fenders -Horizontal Fenders D Shaped Rubber Fenders Perished / Cracked, To Be Renewed As Per Nes170 ( A ) Fenders Details Are As Follows - Mat-Epdm, Colour-Black Rubber 1400 Mm ( 03 + 03 Both Side ) In 5.0 Mtrs Length And 1400 Mm ( 1+1 Both Side ) In 2.0 Mtrs Width 1.0047 021 D Type Rubber Fenders -Vertical Fenders D Shaped Rubber Fenders Perished / Cracked, To Be Renewed, As Per Nes 170 ( B ) Fenders Details Are As Follows - Mat-Epdm, Colour-Black Rubber Size -850 X250 X70 Mm 1.0048 022 Fenders Brackets - Horizontal Horizontal Fender Securing Brackets ( Flat Bars Including Ms Pad Of Both Ends, Mat- Ms ) Corroded / Thinned / Perishe , To Be Renewed Thickenss Of The Brackets 12 Mm, 1400 X 130Mm 1.0049 022 D Type Rubber Fenders -Vertcal Fenders D Shaped Rubber Fenders Perished / Cracked, To Be Renewed As Per Nes170 Fenders Details Are As Follows - Mat-Epdm, Colour-Black Rubber 800 Mm At Corner 1.005 022 Fenders Brackets -Vertical Vertical Fender Securing Brackets ( Flat Bars Including Ms Pad Of Both Ends, Mat- Ms ) Corroded / Thinned / Perishe , To Be Renewed Thickenss Of The Brackets 12 Mm, 1000 X 130Mm 1.0051 023 Lifting Eye Lifting Eye Corroded / Thinned / Perished To Be Renewed As Per Survey Reports ( A ) Thickness Of Rod 40Mm, Outer Dia Of Ring 07 Seven, Base Size 9X5X12mm Doubler Plate Size 14X11X20mm 1.0052 023 Lifting Eye ( B ) Load Testing Of Lifting Eyes Is To Be Carried Out Post Renewel / Repaired If Any ( Test Load To Be Applied 7.5 T, Swl 3.0T ) 1.0053 024 Dead Weight Renew Damaged Dead Weights Approx Size 350X350x350 Mm Weight 40 Kgs Each / Mat Cement 1.0054 Sow- In Asset - 2 ( 04X03x01 Mtrs ) 001 Docking- Vessel To Be Docked In Both Versions. Note 1:- Firms Not To Quote View Docking, Undocking And Dock Blocks Preparation Will Be Done By Navy And The Job Is Required To Be Carried Out In Navy Premises ( I.E Nd ( V ) Slipway ) . 1.0055 002 Hull Cleaning Under Water And Boot Top Area Hp Jet Clean Entire Under Water Area And Boot Top Area ( With A Pressure Not Exceeding 3000 Psi ) Including Ship Side And Remove The Marine Growth / Barnacles Andpresent For Survey ( Approx Weight Of Pontoon - 10 Tons ) . ( A ) U / W Area: 15 Sqm ( B ) Boot Top Area: 5 Sqm 1.0056 002 Hull Cleaning Above Water Area ( A ) Clean The Entire Above Water Area With Hp Jet Washing ( With A Pressure Not Exceeding 3000 Psi ) To Remove Salts And Contaminants From The Surface I.A.W. No 01 / 15 And Present For Survey 1.0057 002 Hull Cleaning Weather Deck ( B ) Clean The Entire Weather Deck Including Fittings Area With Hp Jet Washing ( Not Exceeding 3000 Psi ) To Remove Salts And Contaminants From The Surface. I.A.W. No 01 / 15 And Present For Survey 1.0058 002 Hull Cleaning Tanks ( C ) Manually Clean Internal Tanks I.A.W. No 01 / 15 And Present For Survey. The Tanks Should Be Washed Out With Fresh Water And Soap Water To Remoeve Any Sediment Or Dirt Present In The Tank 1.0059 003 Hull Survey External And Internal Hull Survey. Hull Survey. Carry Out Visual And Hammer Survey / Utg Survey In Accordance With No 19 / 06 Of Under Water Hull, Boot Top, Above Water Hull, Weather Decks And All Internal Tanks Etc, All Stiffeners And Deck Fittings Including Lifting Hooks / Eyes. All Manholes To Be Inspected And Repaired To Ensure Water Tightness, Chalk Impression Test To Be Carried Out. Approx Area: 100 Sqm 1.006 004 Utg Survey . Quote For Utg Survey Points At U / W Hull, Above Water, Weather Deck And Covering Entire Part Of Hull. 1.0061 005 Steel Renewals Quote For Steel Renewal At Various Locations As Per Survey Report. Note 1:- Quoted Repair Cost Shall Include Cost Of Both Sides Blasted And Primed Grade `A’ Quality Ship Building Steel For Shell And Is 2062 Grade `B’ Quality Steel For Non Structural Works, Renewal Of All Obstructions In Way Of Steel Renewals Including Minor Fittings With Their Foundations, Etc., As Indicated By Survey Team / Rmt, Proving Of The Weld Runs By Non-Destructive Tests And By Hose Test On Completion Of Welding, Pressure Testing And Proving Of Tanks Where Steel Renewal Undertaken Etc. 1.0062 006 Build Ups ( A ) Carry Out Build Ups As Indicated By The Hull Survey Team / Surveyor Approx Size 25X25 Mm-100 1.0063 006 Build Ups ( B ) Carry Out Build Ups As Indicated By The Hull Survey Team / Surveyor Approx Size 50X50 Mm-100 1.0064 006 Build Ups ( C ) Carry Out Build Ups As Indicated By The Hull Survey Team / Surveyor Approx Size 100X100 Mm-100 1.0065 007 Draught Marks Draught Marks Corroded / Eaten Away, To Be Renewed And Painted. Both Roman And Numeric. 1.0066 008 Sacrificial Anodes ( A ) Renew Sacrificial Anodes ( Mk Ii ) Those Consumed More Than 50% Note:- Anodes Navy / Coy Supply. 1.0067 009 Surface Preparation With Grit Blasting Under Water Area Including Boot Top Area ( A ) Spot Blasting To Sa 2.5 On Paint Damaged Areas / Renewed Plate Areas As Per The Paint Oem Rep Recommendation For Paint Application. 1.0068 009 Surface Preparation With Grit Blasting Under Water Area Including Boot Top Area ( B ) Sweep Blasting To Sa 1 On Paint Damaged Areas / Renewed Plate Areas As Per The Paint Oem Rep Recommendation For Paint Application. 1.0069 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( A ) 1St Coat: Primer - Penguard Primer - 50 Microns 1.007 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( B ) 2Nd Coat: Anti Corrosive - Jotacote Universal ( Aluminium ) - 150 Microns 1.0071 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( C ) 3Rd Coat: Anti Corrosive - Jotacote Universal ( Grey ) - 150 Microns 1.0072 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( D ) 4Th Coat: Tie Coat: Safeguard Es - 125 Microns 1.0073 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( E ) 5Th Coat: A / F: Sea Quantum Pro U And Spectrum 150 Microns ( Light Red / Dark Red ) 1.0074 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( F ) 6Th Coat: A / F: Sea Quantum Pro U And Spectrum 150 Microns ( Light Red / Dark Red / Black ) 1.0075 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( G ) 7Th Coat: A / F: Seaquantum Specturm ( Black ) - 2 X 150 Microns 1.0076 011 Surface Preparation Above Water Area ( A ) Carry Out Surface Preparation With Mechanical Cleaning On Above Water Area To St 3 Standard Under The Suprvision Of Paint Oem. 1.0077 011 Surface Preparation Above Water Area ( B ) Carry Out Surface Preparation With Mechanical Cleaning On Above Water Area To St 1 Standard Under The Suprvision Of Paint Oem. 1.0078 012 Painting - Jotun Scheme. Above Water Area Paint Above Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( A ) 1St Coat: Penguard Primer - 50 Microns Dft 1.0079 012 Painting - Jotun Scheme. Above Water Area Paint Above Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( B ) 2Nd Coat: Jotamastic ( Grey / Red Brown ) - 125 Microns Dft 1.008 012 Painting - Jotun Scheme. Above Water Area Paint Above Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( C ) 3Rd Coat: Jotamastic ( Grey / Red Brown ) - 125 Microns Dft 1.0081 012 Painting - Jotun Scheme. Above Water Area Paint Above Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( D ) 4Th Coat: Hard Top Xp Grey - 60 Microns Dft 1.0082 013 Surface Preparation Weather Decks And Fittings ( A ) Carry Out Spot Blasting To Sa 2.5 Standards As Per Survey Report Of Paint Oem For Paint Application For Entire Weather Deck. 1.0083 014 Painting - Jotun Scheme Weather Decks And Fittings Paint Weather Decks And Fittings With Following Paint Scheme:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( A ) 1St Coat: Primer - Penguard Primer -50 Microns Dft 1.0084 014 Painting - Jotun Scheme Weather Decks And Fittings Paint Weather Decks And Fittings With Following Paint Scheme:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( B ) 2Nd Coat: Jotamastic 87 Of 200 Microns 1.0085 014 Painting - Jotun Scheme Weather Decks And Fittings Paint Weather Decks And Fittings With Following Paint Scheme:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( C ) 3Rd Coat: Jota Armour Dark Grey Of 800 Microns 1.0086 015 Surface Preparation Internal Tanks Carry Out Mechanical Cleaning To St3 Standard At Paint Defective Area / As Survey Report Of Paint Oem For Paint Application. 1.0087 016 Painting - Jotun Scheme Paint All Internal Tanks With Following Paint Scheme Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( A ) 1St Coat: Primer - Penguard Primer -50 Microns Dft 1.0088 016 Painting - Jotun Scheme Paint All Internal Tanks With Following Paint Scheme Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( B ) 2Nd Coat: Anticorrosive Balloxy ( Hb Light ) - 150 Microns 1.0089 016 Painting - Jotun Scheme Paint All Internal Tanks With Following Paint Scheme Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( C ) 3Rd Coat: Anticorrosive Balloxy ( Hb Light ) - 150 Microns 1.009 017 Deck Fitting ( A ) Twin Bollards On Weather Deck Corroded / Thinned / Perished , To Be Repair / Renewal As Per Survey Reports ( Mat. - Ms ) 400Mmx800mmx08mm Base, 600Mmx200mmx08mm U Plate, 250Mmx160mmx06mm Pipes, 400Mmx25mm Stag Horns ( Rods ) 1.0091 017 Deck Fitting ( B ) Ms Cleats On Weather Deck Including Locking Pins Perished / Uprooted To Be Repaired / Renewed ( Mat Ms ) As Per Survey Reports. Mat-Ms. 1.0092 017 Deck Fitting Carry Out Load Testing Of Twin Bolllrads ( C ) Load Testing Of Securing Eyes Post Welding ( Test Load To Be Applied 7.5 T, Swl 3.0T ) 1.0093 018 Manhole Cover ( A ) Manhole Cover Neoprene Rubber Joints Perished, To Be Renewed ( Rubber Joint Size: - 520Mm X 760Mm X08 Mm ) 1.0094 018 Manhole Cover ( B ) Manhole Cover Including Coamings Perihsed / Thinned To Be Renewed As Per Survey Report ( Approx Size - 3X18 ) 1.0095 018 Manhole Securing Arrangment C ) Manhole Stud Nut And Bolts With Washers Corroded / Perished To Be Renewed. ( Size Of Stud Bolt -16 Mm X 50Mm Length, 32 Nos On Each Manhole, Mat Ss ) . 1.0096 019 Manhole Cover Handle Of Manhole Covers Corroded / Thinned, To Be Renewed, ( Mat-Ms Rod, 12 Mm Thick 1.0097 020 Apt Air Pressure Test The Following Tanks And Rectify The Defects Any Observed During Pressure Testing And Prove To 0.14 Kg / Cm2. Note:- Apt And Proving Of Those Tanks Wherein Steel Renewal Undertaken As Part Of Steel Renewal Dl. 0003 ( C ) Above Is That Of Firms Liability With No Additional Cost And Those Tanks Where No Steel Renewals Undertaken Only Would Be Considered For Payment As Per The Indicated Rates Under This Dl. Serial. Internal Tank 1.0098 021 D Type Rubber Fenders -Horizontal Fenders D Shaped Rubber Fenders Perished / Cracked, To Be Renewed As Per Nes170 ( A ) Fenders Details Are As Follows - Mat-Epdm, Colour-Black Rubber 1400 Mm ( 02 + 02 Both Side ) In 3.0 Mtrs Side And 1400 Mm ( 3+3 Both Side ) In 4.0 Mtrs Side 1.0099 022 Fenders Brackets - Horizontal Horizontal Fender Securing Brackets ( Flat Bars Including Ms Pad Of Both Ends, Mat- Ms ) Corroded / Thinned / Perishe , To Be Renewed ( A ) Thickenss Of The Brackets 12 Mm, 1400 X 130Mm 1.01 022 D Type Rubber Fenders -Vertcal Fenders D Shaped Rubber Fenders Perished / Cracked, To Be Renewed As Per Nes170 Fenders Details Are As Follows - Mat-Epdm, Colour-Black Rubber 850 X250 X70 Mm At Corner 1.0101 022 Fenders Brackets -Vertical Vertical Fender Securing Brackets ( Flat Bars Including Ms Pad Of Both Ends, Mat- Ms ) Corroded / Thinned / Perishe , To Be Renewed Thickenss Of The Brackets 12 Mm, 1000 X 130Mm 1.0102 023 Lifting Eye Lifting Eye Corroded / Thinned / Perished To Be Renewed As Per Survey Reports ( A ) Thickness Of Rod 40Mm, Outer Dia Of Ring 07 Seven, Base Size 9X5X12mm Doubler Plate Size 14X11X20mm 1.0103 023 Lifting Eye ( B ) Load Testing Of Lifting Eyes Is To Be Carried Out Post Sunewel / Repaired If Any ( Test Load To Be Applied 7.5 T, Swl 3.0T ) 1.0104 024 Dead Weight Renew Damaged Dead Weights Approx Size 350X350x350 Mm Weight 40 Kgs Each / Mat Cement 1.0105 Sow- In Asset - 3 ( 04X03x01 Mtrs ) 001 Docking- Vessel To Be Docked In Both Versions. Note 1:- Firms Not To Quote View Docking, Undocking And Dock Blocks Preparation Will Be Done By Navy And The Job Is Required To Be Carried Out In Navy Premises ( I.E Nd ( V ) Slipway ) . 1.0106 002 Hull Cleaning Under Water And Boot Top Area Hp Jet Clean Entire Under Water Area And Boot Top Area ( With A Pressure Not Exceeding 3000 Psi ) Including Ship Side And Remove The Marine Growth / Barnacles Andpresent For Survey ( Approx Weight Of Pontoon - 10 Tons ) . ( A ) U / W Area: 15 Sqm ( B ) Boot Top Area: 5 Sqm 1.0107 002 Hull Cleaning Above Water Area A ) Clean The Entire Above Water Area With Hp Jet Washing ( With A Pressure Not Exceeding 3000 Psi ) To Remove Salts And Contaminants From The Surface I.A.W. No 01 / 15 And Present For Survey 1.0108 002 Hull Cleaning Weather Deck ( B ) Clean The Entire Weather Deck Including Fittings Area With Hp Jet Washing ( Not Exceeding 3000 Psi ) To Remove Salts And Contaminants From The Surface. I.A.W. No 01 / 15 And Present For Survey 1.0109 002 Hull Cleaning Tanks ( C ) Manually Clean Internal Tanks I.A.W. No 01 / 15 And Present For Survey. The Tanks Should Be Washed Out With Fresh Water And Soap Water To Remoeve Any Sediment Or Dirt Present In The Tank 1.011 003 Hull Survey External And Internal Hull Survey. Hull Survey. Carry Out Visual And Hammer Survey / Utg Survey In Accordance With No 19 / 06 Of Under Water Hull, Boot Top, Above Water Hull, Weather Decks And All Internal Tanks Etc, All Stiffeners And Deck Fittings Including Lifting Hooks / Eyes. All Manholes To Be Inspected And Repaired To Ensure Water Tightness, Chalk Impression Test To Be Carried Out. Approx Area: 100 Sqm 1.0111 004 Utg Survey .Quote For Utg Survey Points At U / W Hull, Above Water, Weather Deck And Covering Entire Part Of Hull. 1.0112 005 Steel Renewals Quote For Steel Renewal At Various Locations As Per Survey Report. Note 1:- Quoted Repair Cost Shall Include Cost Of Both Sides Blasted And Primed Grade `A’ Quality Ship Building Steel For Shell And Is 2062 Grade `B’ Quality Steel For Non Structural Works, Renewal Of All Obstructions In Way Of Steel Renewals Including Minor Fittings With Their Foundations, Etc., As Indicated By Survey Team / Rmt, Proving Of The Weld Runs By Non-Destructive Tests And By Hose Test On Completion Of Welding, Pressure Testing And Proving Of Tanks Where Steel Renewal Undertaken Etc. 1.0113 006 Build Ups ( A ) Carry Out Build Ups As Indicated By The Hull Survey Team / Surveyor Approx Size 25X25 Mm-100 1.0114 006 Build Ups ( B ) Carry Out Build Ups As Indicated By The Hull Survey Team / Surveyor Approx Size 50X50 Mm-100 1.0115 006 Build Ups ( C ) Carry Out Build Ups As Indicated By The Hull Survey Team / Surveyor Approx Size 100X100 Mm-100 1.0116 007 Draught Marks Draught Marks Corroded / Eaten Away, To Be Renewed And Painted. Both Roman And Numeric. 1.0117 008 Sacrificial Anodes ( A ) Renew Sacrificial Anodes ( Mk Ii ) Those Consumed More Than 50% Note:- Anodes Navy / Coy Supply. 1.0118 009 Surface Preparation With Grit Blasting Under Water Area Including Boot Top Area ( A ) Spot Blasting To Sa 2.5 On Paint Damaged Areas / Renewed Plate Areas As Per The Paint Oem Rep Recommendation For Paint Application. 1.0119 009 Surface Preparation With Grit Blasting Under Water Area Including Boot Top Area ( B ) Sweep Blasting To Sa 1 On Paint Damaged Areas / Renewed Plate Areas As Per The Paint Oem Rep Recommendation For Paint Application. 1.012 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( A ) 1St Coat: Primer - Penguard Primer - 50 Microns 1.0121 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( B ) 2Nd Coat: Anti Corrosive - Jotacote Universal ( Aluminium ) - 150 Microns 1.0122 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( C ) 3Rd Coat: Anti Corrosive - Jotacote Universal ( Grey ) - 150 Microns 1.0123 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( D ) 4Th Coat: Tie Coat: Safeguard Es - 125 Microns 1.0124 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( E ) 5Th Coat: A / F: Sea Quantum Pro U And Spectrum 150 Microns ( Light Red / Dark Red ) 1.0125 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( F ) 6Th Coat: A / F: Sea Quantum Pro U And Spectrum 150 Microns ( Light Red / Dark Red / Black ) 1.0126 010 Painting - Jotun Scheme Under Water Area Including Boot Top Area Paint Under Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( G ) 7Th Coat: A / F: Seaquantum Specturm ( Black ) - 150 Microns 1.0127 011 Surface Preparation Above Water Area ( A ) Carry Out Surface Preparation With Mechanical Cleaning On Above Water Area To St 3 Standard Under The Suprvision Of Paint Oem. 1.0128 011 Surface Preparation Above Water Area ( B ) Carry Out Surface Preparation With Mechanical Cleaning On Above Water Area To St 1 Standard Under The Suprvision Of Paint Oem. 1.0129 012 Painting - Jotun Scheme. Above Water Area Paint Above Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( A ) 1St Coat: Penguard Primer - 50 Microns Dft 1.013 012 Painting - Jotun Scheme. Above Water Area Paint Above Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( B ) 2Nd Coat: Jotamastic ( Grey / Red Brown ) - 125 Microns Dft 1.0131 012 Painting - Jotun Scheme. Above Water Area Paint Above Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( C ) 3Rd Coat: Jotamastic ( Grey / Red Brown ) - 125 Microns Dft 1.0132 012 Painting - Jotun Scheme. Above Water Area Paint Above Water Area With Following Paint Scheme As Per Oem Recommendations:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( D ) 4Th Coat: Hard Top Xp Grey - 60 Microns Dft 1.0133 013 Surface Preparation Weather Decks And Fittings ( A ) Carry Out Spot Blasting To Sa 2.5 Standards As Per Survey Report Of Paint Oem For Paint Application For Entire Weather Deck. 1.0134 014 Painting - Jotun Scheme Weather Decks And Fittings Paint Weather Decks And Fittings With Following Paint Scheme:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( A ) 1St Coat: Primer - Penguard Primer -50 Microns Dft 1.0135 014 Painting - Jotun Scheme Weather Decks And Fittings Paint Weather Decks And Fittings With Following Paint Scheme:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( B ) 2Nd Coat: Jotamastic 87 Of 200 Microns 1.0136 014 Painting - Jotun Scheme Weather Decks And Fittings Paint Weather Decks And Fittings With Following Paint Scheme:- Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( C ) 3Rd Coat: Jota Armour Dark Grey Of 800 Microns 1.0137 015 Surface Preparation Internal Tanks Carry Out Mechanical Cleaning To St3 Standard At Paint Defective Area / As Survey Report Of Paint Oem For Paint Application. 1.0138 016 Painting - Jotun Scheme Paint All Internal Tanks With Following Paint Scheme Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( A ) 1St Coat: Primer - Penguard Primer -50 Microns Dft 1.0139 016 Painting - Jotun Scheme Paint All Internal Tanks With Following Paint Scheme Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( B ) 2Nd Coat: Anticorrosive Balloxy ( Hb Light ) - 150 Microns 1.014 016 Painting - Jotun Scheme Paint All Internal Tanks With Following Paint Scheme Note:- Quoted Repair Cost Shall Be Inclusive Of Cost Of Paints Also. ( C ) 3Rd Coat: Anticorrosive Balloxy ( Hb Light ) - 150 Microns 1.0141 017 Deck Fitting ( A ) Twin Bollards On Weather Deck Corroded / Thinned / Perished , To Be Repair / Renewal As Per Survey Reports ( Mat. - Ms ) 400Mmx800mmx08mm Base, 600Mmx200mmx08mm U Plate, 250Mmx160mmx06mm Pipes, 400Mmx25mm Stag Horns ( Rods ) 1.0142 017 Deck Fitting ( B ) Ms Cleats On Weather Deck Including Locking Pins Perished / Uprooted To Be Repaired / Renewed ( Mat Ms ) As Per Survey Reports. Mat-Ms. 1.0143 017 Deck Fitting Carry Out Load Testing Of Twin Bolllrads ( C ) Load Testing Of Securing Eyes Post Welding ( Test Load To Be Applied 7.5 T, Swl 3.0T ) 1.0144 018 Manhole Cover ( A ) Manhole Cover Neoprene Rubber Joints Perished, To Be Renewed ( Rubber Joint Size: - 520Mm X 760Mm X08 Mm ) 1.0145 018 Manhole Cover ( B ) Manhole Cover Including Coamings Perihsed / Thinned To Be Renewed As Per Survey Report ( Approx Size - 3X18 ) 1.0146 018 Manhole Securing Arrangment C ) Manhole Stud Nut And Bolts With Washers Corroded / Perished To Be Renewed. ( Size Of Stud Bolt -16 Mm X 50Mm Length, 32 Nos On Each Manhole, Mat Ss ) . 1.0147 019 Manhole Cover Handle Of Manhole Covers Corroded / Thinned, To Be Renewed, ( Mat-Ms Rod, 12 Mm Thick 1.0148 020 Apt Air Pressure Test The Following Tanks And Rectify The Defects Any Observed During Pressure Testing And Prove To 0.14 Kg / Cm2. Note:- Apt And Proving Of Those Tanks Wherein Steel Renewal Undertaken As Part Of Steel Renewal Dl. 0003 ( C ) Above Is That Of Firms Liability With No Additional Cost And Those Tanks Where No Steel Renewals Undertaken Only Would Be Considered For Payment As Per The Indicated Rates Under This Dl. Serial. Internal Tank 1.0149 021 D Type Rubber Fenders -Horizontal Fenders D Shaped Rubber Fenders Perished / Cracked, To Be Renewed As Per Nes170 ( A ) Fenders Details Are As Follows - Mat-Epdm, Colour-Black Rubber 1200 Mm ( 02 + 02 Both Side ) In 3.0 Mtrs Side And 1200 Mm ( 3+3 Both Side ) In 4.0 Mtrs Side 1.015 022 Fenders Brackets - Horizontal Horizontal Fender Securing Brackets ( Flat Bars Including Ms Pad Of Both Ends, Mat- Ms ) Corroded / Thinned / Perishe , To Be Renewed ( A ) Thickenss Of The Brackets 12 Mm, 1400 X 130Mm 1.0151 022 D Type Rubber Fenders -Vertcal Fenders D Shaped Rubber Fenders Perished / Cracked, To Be Renewed As Per Nes170 Fenders Details Are As Follows - Mat-Epdm, Colour-Black Rubber 850 X250 X70 Mm At Corner 1.0152 022 Fenders Brackets -Vertical Vertical Fender Securing Brackets ( Flat Bars Including Ms Pad Of Both Ends, Mat- Ms ) Corroded / Thinned / Perishe , To Be Renewed Thickenss Of The Brackets 12 Mm, 1000 X 130Mm 1.0153 023 Lifting Eye Lifting Eye Corroded / Thinned / Perished To Be Renewed As Per Survey Reports ( A ) Thickness Of Rod 40Mm, Outer Dia Of Ring 07 Seven, Base Size 9X5X12mm Doubler Plate Size 14X11X20mm 1.0154 023 Lifting Eye ( B ) Load Testing Of Lifting Eyes Is To Be Carried Out Post Sunewel / Repaired If Any ( Test Load To Be Applied 7.5 T, Swl 3.0T ) 1.0155 024 Dead Weight Renew Damaged Dead Weights Approx Size 350X350x350 Mm Weight 40 Kgs Each / Mat Cement 1.0156 Dry Dock And Allied Services Work Package ( A ) Docking And Undocking Charges ( Both Versions ) Firm Not To Quote. Docking And Undocking Will Be Done By Navy In Navy Permises I.E Nd ( V ) / Slipway. 1.0157 ( B ) Dock Blocks Preparation & Laying Out As Per Docking Plan Firm Not To Quote. Job Will Be Done By Navy . 1.0158 Quote For Maintenance Of Two In No. Fire Lines For The Refit Duration . Firm To Quote. 1.0159 Provision Of Two Transports ( Cars ) For Entire Refit Duration ( One For Refit Co-Ordinating Staff And One For Nd ( V ) Monitoring Team ) For 12 Hrs Or 100Km / Day Whichever Is Less Firm To Quote. 1.016 Provision Of Stationory / Office Items For Nd ( V ) / Refit Monitoring Team For Entire Refit Duration Period. Cater Budget Of Rs 2000 / - Per Month. Requirement Will Be Intimated Rmt / Ndv On As Requirement Basis. Payment At Actuals. Note:- Firms To Quote. Firm To Quote. 1.0161 Qc Inspection For The Entire Scope Of Work By Third Party Irs / Lrs / Abs / Qc / Tpi For The Refit Duration As Per The Qis. Firm Not To Quote. Services Will Be Provided By Nd ( V ) / Qc

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 1.0 /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail