| 1 | Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panelincluding bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work with inclosure box (HSR 23.22.1)23.22.1.8 TRIPLE POLE MCCB 600 to 800 Amp, 50 KA |
| 2 | SITC Four pole ON LOAD Manual change over switch in SS enclosureof following Ratings (HSR 23.22.8)23.22.8.5400 amp 415 volts |
| 3 | Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. (HSR 23.23.6)23.23.6.1 MS perforated cable tray painted with powder coating 100 X 50X2 mm |
| 4 | 23.23.6.2 MS perforated cable tray painted with powder coating 200 X 50X 2 mm |
| 5 | 23.23.6.3 MS perforated cable tray painted with powder coating 375 X 50X 2 mm |
| 6 | Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as requiredincluding erection of the same on existing cable trayduly pained as required includind with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. (HSR 23.23.7) 23.23.7.2 GI cable tray cover, suitable for cable tray200 X 50X2 mm |
| 7 | 23.23.7.3 GI cable tray cover, suitable for cable tray375 X 50X 2 mm |
| 8 | Supply and erection of suitable compression type brass cable glands for underground Cable :(HSR.24.2.7) 24.2.7.5120 sqmm to 185 sqmm Cable 3 to 3.5 Core |
| 9 | 24.2.7.6 240 sqmm to 185 sqmm Cable 3 to 3.5 Core |
| 10 | 24.2.7.7300 sqm to 400 sqmm cable 3 to 3.5 core |
| 11 | Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work .(HSR 24.2.8)24.2.8.9 95 sqmm |
| 12 | 24.2.8.10120 sqmm |
| 13 | 24.2.8.11150 sqmm |
| 14 | 24.2.8.13 240sqmm |
| 15 | 24.2.8.14300 sqmm |
| 16 | S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.(HSR 24.5.2)24.5.2.5DWC/HDPE pipe 120/105 mm outer dial inner dia |
| 17 | 24.5.2. 6 DWC/HDPE pipe 145/123 mm outer dial inner dia |
| 18 | 24.5.2. 7 DWC/HDPE pipe 180/150 mm outer dial inner dia |
| 19 | Supply and erection of underground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging andrefilling of trenches:- (NS)LT XLPE power cable (armoured) 150 sqmm 3.5 core Aluminum conforming to IS 7098 (Part-1) : 2021, IS:8130- 2013, IEC 60502, IS: 5831-1984 standard with latest amendment thereof |
| 20 | Supply and erection of underground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging andrefilling of trenches:- (NS)LT XLPE power cable (armoured) 240 sqmm 3.5 core Aluminum conforming to IS 7098 (Part-1) : 2021, IS:8130- 2013, IEC 60502, IS: 5831-1984 standard with latest amendment thereof |
| 21 | Supply and erection of underground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging andrefilling of trenches:- (NS)LT XLPE power cable (armoured) 300 sqmm 3.5 core Aluminum conforming to IS 7098 (Part-1) : 2021, IS:8130- 2013, IEC 60502, IS: 5831-1984 standard with latest amendment thereof |
| 22 | S/E of underground cable, loose in existing pipe or trenches complete with necessary connections:- (NS)LT XLPE power cable (armoured) 120 sqmm 3.5 core Aluminum conforming to IS 7098 (Part-1) : 2021, IS:8130- 2013, IEC 60502, IS: 5831-1984 standard with latest amendment thereof |
| 23 | S/E of underground cable, loose in existing pipe or trenches complete with necessary connections:- (NS)LT XLPE power cable (armoured) 150 sqmm 3.5 core Aluminum conforming to IS 7098 (Part-1) : 2021, IS:8130- 2013, IEC 60502, IS: 5831-1984 standard with latest amendment thereof |
| 24 | S/E of underground cable, loose in existing pipe or trenches complete with necessary connections:- (NS)LT XLPE power cable (armoured) 240 sqmm 3.5 core Aluminum conforming to IS 7098 (Part-1) : 2021, IS:8130- 2013, IEC 60502, IS: 5831-1984 standard with latest amendment thereof |
| 25 | S/E of underground cable, loose in existing pipe or trenches complete with necessary connections:- (NS)LT XLPE power cable (armoured) 300 sqmm 3.5 core Aluminum conforming to IS 7098 (Part-1) : 2021, IS:8130- 2013, IEC 60502, IS: 5831-1984 standard with latest amendment thereof |
| 26 | Distribution Transformer Supply and erection ,testing and commissioning of transformer 1000KVA 11 /0.433 KV 3 phase 50 cycle copper wound outdoor type confirming IS 1180-(Latest updated versions) Level -2 upto the entire satisfactionof the engineer of the work as per detail specification given as under with 6 year warranty:- Make Kirloskar/Crompton/Alstom. specified as below (NS)Output / capacity- 1000KVAas per detail specification given in DNIT ANX-A, Sr. No. 26 |
| 27 | LT POWER FACTOR PANEL:-Supply,installation ,testing & commissioning of cubical type panel dust & vermin proof.free standing floor mounting made out of 2MM thick CRCA sheet with 75mmx40mmx6mm chanel iron base frame painted with stove enamelled power coated paintL.T. automatic power factor control panel 360 KVAR capacity suitable for automatic operation & control of power factor within the set limits suitable for operation on 3 phase 4 wire 50 Hz 400/440 volt s A.C. supply. including the cost of following items. (NS)as per detail specification given in DNIT ANX-A, Sr. No. 27 |
| 28 | Supply and erection of outdoor type end termination jointing box heat shrinkable type suitable for 95 Sqmm3 core 11 K.V HT. XLPEcable with epoxy cast bushing including making necessary connection with all labour and material required to complete the job all in respect upto the entire satisfaation of the Engineer-in -charge of the work. Make: Denson/3M/ (NS) |
| 29 | Supply and erection of fencing for safety precaution made out with the help of50mm x 50mm x6mm angle iron(The distance shall not be max. 950mm Horizental and 25mm Vertical between to angle ) ,MS flate 50mm x 6mm ,(The distance shall not be max 800 mm verticalbetween to flate) MS jali wire gauge 3.5 mm duly painted with red enameled painti/c one coat of red oxide .The fencing angle shall be embeded in groundwith C:Cmixture at least 90 cm in ground level including all labour and material required to complete the jobat site. (NS) |
| 30 | Supply and laying crushed stone agreegate 25 mm gauge aroundthe D/TF (NS) |
| 31 | Supply,intallation, testing and commissioning of ACB1600 amp. 4 pole 50 KA of L&T C- POWER, SR18G MDO /HAVELLS/L&T / INDO ASIANmake in existing panel microprocessor based with L.S.I.G. protectionmanualydraw out type manually operated complete with under voltage trip & shunt-trip. ACB should have alarm for temp. rise 75 centigrate with LED indication so that ACB self trip more than at 95 centigrateand ICS =ICU =ICW 100% for 1 Second. Suitablefor operation on 400/440 volts 3 phase , 4 wire 50Hz AC supply with 4 Nos or 6 Nos.. (NC+No) auxilary contacts and comprising of :- (NS)as per detail specification given in DNIT ANX-A, Sr. No. 31 |
| 32 | S/E, testing and commissioning of indoorcubical type, dustand verman proof LT pannel free standing floor mounting made outof 16G. M.S. sheet with channel size 50 x 50 x 6mm iron base frame painted with strong synthetic light gray enamel paint suitable for operation on 3 phase 4 wire 50 cycles400/440 volts A.C. supply including the cost of following items (NS)as per detail specification given in DNIT ANX-A, Sr. No. 32 |
| 33 | S/E, testing and commissioning of indoorcubical type, dustand verman proof LT pannel free standing floor mounting made outof 16G. M.S. sheet with channel size 50 x 50 x 6mm iron base frame painted with strong synthetic light gray enamel paint suitable for operation on 3 phase 4 wire 50 cycles400/440 volts A.C. supply including the cost of following items (NS)as per detail specification given in DNIT ANX-A, Sr. No. 33 |