| 1 | 1 | Design, drawing, Supplying inculding cost of transportation to the site with prior submission and approval of pump performance Data sheet and curve with Pump & Motor GA Drawing, Installation over 16meter Intake well & Preparation of RCC Base with MS Joist/Plate arrangement with necessory modification required in the existing platform and all other ancilary work as per the site condition with Testing and commissioning with authorised technician of 2 number 75 HP = 150 HP Three Phase Vertical Turbine Pump Set for Total Suspension Length inculding Strainer = 15.00 Meter with bronze bowl & impeller assembly, 1.50 meter each column pipe (i.e. Transmission Bearing maximum span - 1.50 meter), Stainless steel Shaft, discharge header, motor, Pressure Gauge, companion flanged having Discharge of 55 LPS at a Total Head of 75.00 Mtr. with Strainer inculding fittings etc. complete with one year free maintenance by agency and as per direction of Engineer-in-charge. (Delivery Challan, Warrenty card cum Testing certificate, Invoice of authorised supplied company and Detail list for tools & accessories to be submitted at the time of delivery) Make : Kirlosker/Cromption Greaves/wilo | BI01010001010000000000000515BI0100001112 | 150 | HP |
|---|
| 2 | 2 | Supplying with prior permission, Installation with MS Joist/Plate arrangement with necessory modification required in the existing platform and all other ancilary work as per the site condition with Testing and commissioning with authorised experts of 2 number Air Compressor of 10 HP Motor Make : Cromption Greaves / SIEMENS / ABB having 1500 RPM speed, IE-2, 4 Pole, Discharge Pressure 0.30 Kg/Cm², Capacity 473 M³/Hr, Model M5175 Air Blower, mounted on a common MS Frame with companion flanges, suction silencer, suction air filter, pressure gauge, spring loaded type pressure relief valve, Blower & Motor Pulley, Coupling with Guard, V-Bels, Non return valves, 32mm Gun Metal Full Way Valve, Interconnecting line with flanges, inculding fittings etc. all complete with one year free maintenance and as per direction of Engineer-in-charge. (Delivery Challan, Warrenty card cum Testing certificate, Invoice of authorised supplied company and Detail list for tools & accessories to be submitted at the time of delivery) | BI01010001010000000000000515BI0100001113 | 2 | Each |
|---|
| 3 | 3 | Dismantling and removing cement concrete including stacking the useful materials for reuse and removing the debreis within 50 M lead. | BI01010001010000000000000515BI0100001114 | 1.62 | Cum |
|---|
| 4 | 4 | Filling foundation and plinth with sand well watered and rammed. | BI01010001010000000000000515BI0100001115 | 0.324 | Cum |
|---|
| 5 | 5 | Cement concrete (1:3:6) with 4cm size hard granite crusher broken metal. | BI01010001010000000000000515BI0100001117 | 0.324 | Cum |
|---|
| 6 | 6 | Cement concrete (1:1.5:3) with 12mm size hard granite crusher broken chips for RCC work including cost , conveyance, royality all taxes but excluding cost of MS rod and binding wire etc as per direction of EIC for | BI01010001010000000000000515BI0100001118 | 0.972 | Cum |
|---|
| 7 | 7 | Rigid & smooth centering & shuttering for RCC work including false works and dismantling them after casting including cost of materials complete in ground floor. (RCC foundation, plinth band and footing bases of columns mass concrete pre-cast slab etc.) | BI01010001010000000000000515BI0100001120 | 1.08 | Sqm |
|---|
| 8 | 8 | Labour for M.S reinforcement for R.C.C work including cutting , bending , binding and tying the grills and placing the position including cost of bending wire 18 to 20 gauge and including cost conveyance and royality of material etc. all complete as per direction of EIC | BI01010001010000000000000515BI0100001121 | 0.5832 | Qntl |
|---|
| 9 | 9 | Supply, Installation, Testing & Commissioning of Auto Transformer Starter Control (ATS) pannel premium version as with MCCB as incomer, Super Heavy Duty Transformer with copper winding, 3 No. power contractor of suitable rating, Citation over load relay, electronic SPP, Ammeter and Voltmeter with selection switch, RYB Indication lamp and motor on, off, trip indication lamp. The ATS enclosure is with 10 tank pretreated and boiled construction with PU door gasket. ATS control panel will provide short circuit, under voltage, over load & single phasing protection to motor as standard etc. all complete with necessary fittings and all other ancilary work as per the site requirement in complete manner and as per direction of Engineer-incharge. For 2 No 75 HP VT Motors, 2 No 10 HP Air Compressors, Total 4 Number (170 HP) (Make : BCH / L&T / Seimens) | BI01010001010000000000000515BI0100001122 | 170 | HP |
|---|
| 10 | 10 | Supply, Installation, Testing and Commissioning of 62.50 KVA Three Phase (Silent and out door type) DG set with water cooling facility having 3 cylinder, in-line, 4 stroke, 1500 RPM, conforming to ISO 3046 / BS 5514, 12V, 88AH Battery and standard manual control panel and fitting over Cement concrete base with shed with all required spares and materials handling, loading and unloading at site with Hydra support etc all complete at Jogeswar Mandir Pump House and as per direction of Engineer-in-Charge. (Including One year free maintenance), Make : Jakson, / Kirloskar / Greaves cotton | BI01010001010000000000000515BI0100001123 | 1 | No |
|---|
| 11 | 11 | Earth work in excavation of foundation in all kinds of soil with50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth with cost of all labour& T&P required for the work etc. complete | BI01010001010000000000000515BI0100001124 | 8.21628 | Cum |
|---|
| 12 | 12 | Filling in foundation and plinth with sand well watered and rammed including cost of all materials with cost of all labour& T&P required for the work etc. complete | BI01010001010000000000000515BI0100001125 | 7.57422 | Cum |
|---|
| 13 | 13 | Cement concrete (1:4:8) with 4cm size hard granite crusher broken metal with cost conveyance royalties and taxes of all material with cost of all labour& T&P required for the work etc. complete | BI01010001010000000000000515BI0100001126 | 2.69352 | Cum |
|---|
| 14 | 14 | Cement concrete (1:2:4) with 12mm size HGCB chips | BI01010001010000000000000515BI0100001127 | 0.97614 | Cum |
|---|
| 15 | 15 | Flyash Brick work in cement mortar (1:6) in F&P ( 23 x 11 x 8 ) | BI01010001010000000000000515BI0100001129 | 3.08256 | Cum |
|---|
| 16 | 16 | 16mm thick cement plaster (1:6) over brick or stone masonary | BI01010001010000000000000515BI0100001130 | 44.854 | Sqm |
|---|
| 17 | 17 | Priming wall surface One coat with water bound or wall primer on plastered surface | BI01010001010000000000000515BI0100001132 | 21 | Sqm |
|---|
| 18 | 18 | Wall painting Two coats with weather coat paint of approved shade on new work | BI01010001010000000000000515BI0100001133 | 21 | Sqm |
|---|
| 19 | 19 | Providing and fixing to wall or celing and floor galvanised mild steel tubes (Medium Grade 32mm Dia.) | BI01010001010000000000000515BI0100001135 | 85 | Mtr |
|---|
| 20 | 20 | Flame cutting and facing of MS plate up to 8mm thick as per specification complete | BI01010001010000000000000515BI0100001136 | 3 | Mtr |
|---|
| 21 | 21 | Supplying all labour T&P, providing joints by welding with two welding beads / pass, conforming to IS-816-1998 (Fillet weld) to MS pipes and fittings at site by using welding ,generator including testing of joints, as per specification complete. | BI01010001010000000000000515BI0100001137 | 3 | Mtr |
|---|
| 22 | 22 | Fitting and fixing of 0.40mm thick G.C.I. Sheet in roof drilling hole in wind ties including fixing of ridges valleys wind ties etc. all complete | BI01010001010000000000000515BI0100001138 | 15 | Sqm |
|---|
| 23 | 23 | Supplying with prior submission and approval of pump performance Data sheet, Installation, Testing and commissioning of 3 HP Three Phase Sewage De-watering Submersible Pump Set with accessories having Discharge of 550.00 LPM at a Total Head of 10.00 Mtr. inculding fittings etc. complete without control Panel and as per direction of Engineer-in-charge. Make : KSB/Kirlosker/ABB | | 3 | HP |
|---|
| 24 | 24 | Supplying with prior submission and approval of pump performance Data sheet, Installation, Testing and commissioning of 5 HP Three Phase Sewage De-watering Submersible Pump Set with accessories having Discharge of 625.00 LPM at a Total Head of 16.00 Mtr. inculding fittings etc. complete without control Panel and as per direction of Engineer-in-charge. Make : KSB/Kirlosker/ABB | | 5 | HP |
|---|
| 25 | 25 | Supplying with prior submission and approval of pump performance Data sheet and curve with Pump & Motor GA Drawing, Installation, Preparation of RCC Base with MS Joist/Plate arrangement with necessory modification required in the existing platform and all other ancilary work as per the site condition, Testing and commissioning of 7.5 HP (Total 2 number with standby - 2 x 7.50 = 15 HP)Three Phase Star Delta 150mm Borewell Submersible Pump Set with accessories having Discharge of 583.00 LPM at a Total Head of 37.00 Mtr. inculding fittings etc. complete without control Panel and as per direction of Engineer-in-charge. Make : KSB/Kirlosker/ABB | | 15 | HP |
|---|
| 26 | 26 | Supplying of Three Phase Star Delta Economy Submersible Pump starter 1 Number for 3 HP De-Watering Submersible Pump with 3 position selection, Relay Range 3.8 to 6.0 Amp, with Volt Meter, Amp Meter, Single Phase Preventer, Short Circuit Protection through MCB, Contractor protection etc. Quantity - 1 Number for 3 HP Motor, Make - BCH/C&S, Contractor Rating-16A | | 3 | HP |
|---|
| 27 | 27 | Supplying of Three Phase Star Delta premium Submersible Pump starter 1 Number for 5 HP De-Watering Submersible Pump with 3 position selection, Relay Range 6.0 to 9.3 Amp, with Volt Meter, Amp Meter, Single Phase Preventer, Short Circuit Protection through MCB, Contractor protection etc. Quantity- 1 Number for 5 HP Motor, Make - BCH/C&S, Contractor Rating-16A | | 5 | HP |
|---|
| 28 | 28 | Supplying of Three Phase Star Delta premium Submersible Pump starter 2 Number for 7.5 HP = 15 HP, 150mm Bore Well Submersible Pump with 3 position selection, Relay Range 13.2 to 20.0 Amp, with Volt Meter, Amp Meter, Single Phase Preventer, Short Circuit Protection through MCB, Contractor protection etc. Quantity- 2 Number for 7.50 HP Motor = 15 HP, Make - BCH/C&S, Contractor Rating-16A | | 15 | HP |
|---|
| 29 | 29 | Supplying, fitting and fixing of 75mm Heavy Duty PVC Suction (POLYMER REINFORCED FLEXIBLE PIPES) pipes for Sewage De-watering Submersible Pump Set. Make : Oriplast / Sudhakar / Finolex | | 15 | Mtr. |
|---|
| 30 | 30 | Supplying, fitting and fixing of 25mm Heavy Duty PVC Suction (POLYMER REINFORCED FLEXIBLE PIPES) pipes for Sewage De-watering Submersible Pump Set. Make : Oriplast / Sudhakar / Finolex | | 15 | Mtr. |
|---|
| 31 | 31 | Supplying, fitting and fixing of Hand operated Single Girder 3 Ton capacity Hot Crane over 10 Lakh liter UGR for placing of Vertical Turbine Motor and pump set | | 1 | No |
|---|
| 32 | 32 | Supplying, fitting and fixing of 3 Ton capacity mild steel manual operated chain Pulley block with lifting hooks, chains and clamps | | 2 | No |
|---|
| 33 | 33 | Supplying, fitting and fixing of 200mm Dia. (8\") C.I. Foot Valve with M.S. Plate for existing motors | | 1 | No |
|---|
| 34 | 34 | Supplying, fabricating, Fitting, Fixing of 3 number Stainless Steel Ladders inside 1 Lakh liter UGR, 3 Lakh liter UGR and 0.50 Lakh Back wash ESR at WTP site and as per the direction of engineer in-charge in complete manner | | 450 | Kg |
|---|
| 35 | 35 | Design, Drawing, Construction of 3.00mtr. Height, 1 Number watchmen shed of size 6.00mtr..X 3.00mtr. = 18Sqm at Intake well and 1 number Chemical house at WTP of size 6.00mtr. X 3.00mtr. = 18.00Sqm with door, windows, Chajj, Shelve, column and beam, Internal and external painting, etc. complete and all other ancilary work required as per the site requirement in complete manner and as per direction of Engineer-in-charge. (Detail estimate attached as Annexture - 'A' + 'B') | | 1 | Job |
|---|
| 36 | 36 | Opening, fabricating, Fitting and Refixing of 4 number MS Gates of 2 number Filter Beds and 4 number MS Gates of 2 number settling tanks of WTP. The gates, Flow meter and fitting shall be painted with two coats of anticorrosive paint over a coat of primer and as per the direction of engineer in-charge in complete manner. Total 8 number MS gates | | 700 | Kg |
|---|
| 37 | 37 | Removing old lime or cement plaster from walls | | 273.851 | Sqm |
|---|
| 38 | 38 | Fixing tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles compelte including cost of ceramic floor tiles of approved shade | | 183.826 | Sqm |
|---|
| 39 | 39 | Fixing tiles in dados skiring and risers of steps on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigments to match the shade of the tiles including cost of ceramic wall tiles of approved shade | | 80.185 | Sqm |
|---|
| 40 | 40 | Fixing tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including cost of chquared floor tiles of approved shade | | 14.21 | Sqm |
|---|
| 41 | 41 | Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 Mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffinhg, polishing etc. with cost, conveyance, taxes of all materials, labour, T&P etc. required for the work complete in all respect. | | 200 | Rmt. |
|---|
| 42 | 42 | Supplying, fitting & fixing of Stainless Steel Gate of 2.00 Nos x 2.50m x 2.40m @ (25Kg/Sqm) as per specification including cost of all materials, fabrication, conveyance & labour cess etc. all complete as per specification and direction of Engineer-in-charge. | | 300 | Kg |
|---|
| 43 | 43 | Providing and fixing to wall or celing and floor 50mm diameter ASTM - D 1785/2004 Schedule 80 PVC plastic pipe 6 Kg/cm2 | | 60 | Mtr. |
|---|
| 44 | 44 | Earth work in all kinds of soil within 50 M initial lead and 1.5 M initial lift including rough dressing and breaking clods to maximum 5cm to 7cm. And laying in layers not exceeding 0.3 M in depth and as per direction of the Engineer-in-charge. For laying of 50mm dia. PVC pipe | | 12.6 | Cum |
|---|
| 45 | 45 | Providing and laying in trenches 50mm diameter PVC plastic pipe Sch-80 confirming to ASTM - D 1785/2004 6 Kg/cm2 | | 70 | Mtr. |
|---|
| 46 | 46 | Filling foundation & plinth with sand well watered and rammed | | 6.3 | Cum |
|---|
| 47 | 47 | Filling foundation and plinth with excavated Earth inluding watering and ramming | | 6.3 | Cum |
|---|
| 48 | 48 | Fixing of UPVC 50mm dia. Ball Valve of the following nominal sizes and as per spaecification complete. | | 22 | No |
|---|
| 49 | 49 | Dismantling and removing RCC columns, beams slab staircase, landing, lintels including stacking the useful materials for reuse and removing the debreis within 50 M lead. | | 2.284 | Cum |
|---|
| 50 | 50 | Removing old lime or cement plaster from walls including racking out joints 12mm deep and removing the debreis within 50 M lead. | | 35.48 | Sqm |
|---|
| 51 | 51 | Cement concrete (1:1 ½:3) with 12mm. size chips. | | 3.8292 | Cum |
|---|
| 52 | 52 | Supplying fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification. | | 2.68044 | Qntl |
|---|
| 53 | 53 | Rigid & smooth centering & shuttering for RCC work including false works and dismantling them after casting including cost of materials complete in ground floor. (RCC foundtion, plinth band, footing base, columns bass) | | 47.452 | Sqm |
|---|
| 54 | 54 | 12mm. Thick cement plaster (1:4) over brick work with cement punning | | 56.4 | Sqm |
|---|
| 55 | 55 | Opening, fitting and refixing, commissioning and testing of 6 number 0.75 HP existing motors with joist (Electrician High Skilled) | | 10 | No |
|---|
| 56 | 56 | Earth work in all kinds of soil within 50 M initial lead and 1.5 M initial lift including rough dressing and breaking clods to maximum 5cm to 7cm. And laying in layers not exceeding 0.3 M in depth and as per direction of the Engineer-in-charge. | | 3.645 | Cum |
|---|
| 57 | 57 | Filling foundation & plinth with sand well watered and rammed | | 0.6075 | Cum |
|---|
| 58 | 58 | Cement concrete (1:3:6) with 4cm size Hard Granite Crusher Broken Metal | | 0.6075 | Cum |
|---|
| 59 | 59 | Cement concrete (1:1 ½:3) with 12mm. size chips.for R.C.C work including cost of Centering & shuttering charges (Colum base & Plinth bend) | | 2.41438 | Cum |
|---|
| 60 | 60 | Cement concrete (1:1 ½:3) with 12mm. size chips.for R.C.C work including cost of Centering & shuttering charges (Beams and columns) | | 2.36313 | Cum |
|---|
| 61 | 61 | Cement concrete (1:1 ½:3) with 12mm. size chips.for R.C.C work including cost of Centering & shuttering charges (Roof Slab) | | 2.03 | Cum |
|---|
| 62 | 62 | Supplying fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification. | | 6.8075 | Qntl |
|---|
| 63 | 63 | Priming one coat with any approved primer (Plastered Surface) | | 67.0175 | Sqm |
|---|
| 64 | 64 | Wall painting Two coats with weather coat paint of approved shade on new work | | 67.0175 | Sqm |
|---|
| 65 | 65 | Dismantling and removing RCC columns, beams slab staircase, landing, lintels including stacking the useful materials for reuse and removing the debreis within 50 M lead. | | 0.36725 | Cum |
|---|
| 66 | 66 | Dismantling brick or stone masonary in lime or C.M. above 3 M. | | 0.645 | Cum |
|---|
| 67 | 67 | Cement concrete (1:1 ½:3) with 12mm size chips for RCC including Centering & Shuttering (Lintel) | | 5.73658 | Cum |
|---|
| 68 | 68 | Cement concrete (1:1 ½:3) with 12mm size chips for RCC including Centering & Shuttering (Roof Slab) | | 3.28 | Cum |
|---|
| 69 | 69 | Supplying fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification. | | 6 | Qntl |
|---|
| 70 | 70 | Brick work with Flyash bricks 23cm x 11cm x 8cm size having crushing strength not less than 75 Kg./Cm2 with dimentional tolerance + 8% in cement mortar (1:4) in super structure | | 41.69 | Cum |
|---|
| 71 | 71 | 16mm thick cement plaster (1:6) over brick or stone masonary | | 84.08 | Sqm |
|---|
| 72 | 72 | 12mm thick C.P. (1:4) Over brick masonary | | 77.63 | Sqm |
|---|
| 73 | 73 | 6mm thick cement plaster (1:4) finished smooth per 1Sqm Sand (Screened & Washed) | | 118.281 | Sqm |
|---|
| 74 | 74 | Cement punning. | | 85.4812 | Sqm |
|---|
| 75 | 75 | Cement concrete (1:1 ½:3) with 12mm size chips for RCC including Centering & Shuttering (Chajja) | | 8.28 | Sqm |
|---|
| 76 | 76 | Priming one coat with any approved primer (Plastered Surface) | | 161.71 | Sqm |
|---|
| 77 | 77 | Wall painting Two coats with weather coat paint of approved shade on new work | | 84.08 | Sqm |
|---|
| 78 | 78 | Distempering two coats | | 77.63 | Sqm |
|---|
| 79 | 79 | Supplying, fitting, fixing up window (sliding type) made up aluminium Section 151-154, 151 - 155, as windows frame Section No.151-155, 151-153 and 151-167 as shutter frame with 5mm thick black glass as panel lfitted with rubber beading including locking arrangment including all fitting including cost of materials, alll taxes, labour, T&P etc. complete as per direction of the Engineer-in-charge. | | 13.5 | Sqm |
|---|
| 80 | 80 | Providing fitting, fixing of AI door with OEL anodized AI door section of 9202 as verticl member, 9201 as topl member and 9200 as bottom and middle member and 6mm plain glass in top portion with 12mm thick pre-laminated board in bottom portion fixed on door frame by means of tapered clip No.4660 and the frame to be completed by means of jointing angle No.1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges etc complete. | | 24.1875 | Sqm |
|---|
| 81 | 81 | Removing old grading plaster from roof slab. | | 184.2 | Sqm |
|---|
| 82 | 82 | 4cm. thick grading concrete (1:2:4) on roof slab with 12mm. and down graded size black hard granite crusher broken chips for old work. | | 184.2 | Sqm |
|---|
| 83 | 83 | Supplying, Fitting and Fixing of Two number 150mm MS Joist for WTP and Sisumandir pump house | | 220 | Kg |
|---|
| 84 | 84 | Brick work with Flyash bricks 23cm x 11cm x 8cm size having crushing strength not less than 75 Kg./Cm2 with dimentional tolerance + 8% in cement mortar (1:4) in super structure | | 1.29 | Cum |
|---|
| 85 | 85 | 16mm thick cement plaster (1:6) over brick or stone masonary | | 10.32 | Sqm |
|---|
| 86 | 86 | 12mm thick C.P. (1:4) Over brick masonary | | 10.32 | Sqm |
|---|
| 87 | 87 | Cement concrete (1:2:4) with 12mm size Hard Granite Crusher Broken chips | | 0.11625 | Cum |
|---|
| 88 | 88 | Providing and fixing to wall or celing and floor galvanised mild steel tubes ( medium grade) ISI Marked of the following nominal boretube fittings and clamps including making good the wall celling and floor all complete as per specification in ground floor. 40 mm diameter | | 50 | Mtr |
|---|
| 89 | 89 | Fitting and fixing of 0.40mm G.C.I. Sheet in roof drilling hole in wind ties including fixing of ridges valleys wind ties etc. all complete | | 30 | Sqm |
|---|
| 90 | 90 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs (1200 cfm/ 300 psi) as required to suit the site condition as per the direction of Engineer-in-charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of 200 mm dia PVC/GI pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (GI/PVC casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the tube well). | | 60 | Mtr. |
|---|
| 91 | 91 | Labour for lowering of 200 mm dia PVC/GI Casing Pipes For soft, medium, hard rock formation | | 30 | Mtr. |
|---|
| 92 | 92 | Cleaning and developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Charge. | | 1 | No |
|---|
| 93 | 93 | Cost of 200mm Dia.PVC Schedule 80 Casing Pipes IS - 12818-2010 (ISI Marked) Make - Oriplast or Eqivalent | | 30 | Mtr. |
|---|
| 94 | 94 | Supplying, fitting and fixing of Two number Three phase 6.00 HP Motor = 12 HP 100mm (4\") Borewell submersible pump set having Discharge of 200 LPM at a Total Head of 76.00 Mtr. with Delivery size 65mm with stand by | | 12 | HP |
|---|
| 95 | 95 | Supplying, fitting & Fixing of Two Number Three Phase DOL Premium with short Circuit Protection Submersible Pump starter for 6 HP Motor - 2 x 6 HP = 12 HP, with 3 position selection, Relay Range 13.20 to 20.0 Amp, with Volt Meter, Amp Meter, Single Phase Preventer, Short Circuit Protection through MCB, Contractor protection etc. Make - BCH /L&T or equivalent, Contractor Rating-16A, Contract Type- COON, with standby | | 12 | HP |
|---|
| 96 | 96 | Supplying, fitting & Fixing of HDPE pipes confirming to IS 4984-2016 and specials of 75mm Dia HDPE- PN-10/PE-80 including jointing by Fusion Welding method including testing with cost of Pipe. | | 50 | Mtr. |
|---|
| 97 | 97 | Supplying, fitting & Fixing of 4 Sqmm Three core PVC insulated & PVC sheathed industrial cable for submersible motors | | 100 | Mtr. |
|---|
| 98 | 98 | Design, drawing, Supplying with prior submission and approval of pump performance Data sheet and curve with Pump & Motor GA Drawing, Installation, Testing and commissioning of 50 HP Three Phase Induction Motor with Horizintal Split Casing Pump with Tyre Coupling Set with accessories having Discharge of 75 LPS at a Total Head of 36.00 Mtr., Stainless Steel Impeller and Shaft inculding fittings etc. complete without control Panel and as per direction of Engineer-in-charge. Make : KSB/Kirlosker/Wilo | | 50 | HP |
|---|
| 99 | 99 | Supplying, fitting & Fixing of 2 Number Three Phase Star Delta Premium with short Circuit Protection Submersible Pump starter for 50 HP Motor with standby - 2 x 50 HP = 100 HP with 3 position selection, Relay Range 56.40 to 90.00 Amp, with Volt Meter, Amp Meter, Single Phase Preventer, Short Circuit Protection through MCB, Contractor protection etc. Make - BCH /L&T or equivalent, Contractor Rating-110A, Contract Type- Citation M-5 with standby | | 100 | HP |
|---|
| 100 | 100 | Dismantling & removing cement concrete | | 2.244 | Cum |
|---|
| 101 | 101 | Filling foundation and plinth with sand watered and rammed. | | 0.561 | Cum |
|---|
| 102 | 102 | Cement concrete (1:3:6) with 4cm size hard granite crusher broken metal. | | 0.561 | Cum |
|---|
| 103 | 103 | Flyash Brick work in cement mortar (1:4) in F&P ( 23 x 11 x 8 ) | | 0.2002 | Cum |
|---|
| 104 | 104 | Cement concrete (1:1.5:3) with 12mm size hard granite chips for RCC work including cost , conveyance , royality all taxes but excluding cost of MS rod and binding wire etc as per direction of EIC for | | 3.74 | Cum |
|---|
| 105 | 105 | Labour for M.S reinforcement for R.C.C work including cutting , bending , binding and tying the grills and placing the position including cost of bending wire 18 to 20 gauge and including cost conveyance and royality of material etc. all complete as per direction of EIC | | 1.62 | Qntl |
|---|
| 106 | 106 | Supplying all material, labour T&P & laying in trenches GI pipe Jindal/Tata 6mm thickness (Heavy C Class) of conforming to IS : 3589 GR 330 of the following diameter as per specification complete (earth work in excavation in trenches jointing of pipes & specials to be measured separately) 200mm Dia | | 23 | Mtr. |
|---|
| 107 | 107 | Supplying all material, labour T&P & laying in trenches GI pipe (Medium) of conforming to IS : 1239 (Part-1) of the following diameter as per specification complete (earth work in excavation in trenches jointing of pipes & specials to be measured separately) 100mm Dia. | | 78 | Mtr. |
|---|
| 108 | 108 | 150mm Dia. GI Pipe | | 60 | Mtr. |
|---|
| 109 | 109 | 200 mm dia 12 mm thick MS flange | | 20 | Each |
|---|
| 110 | 110 | 150 mm dia 10 mm thick MS flange | | 20 | Each |
|---|
| 111 | 111 | 100 mm dia 10 mm thick MS flange | | 30 | Each |
|---|
| 112 | 112 | Supply, Fitting and fixing of 200mm dia. Rubber expansion Joint with galvised fittings, Tie rod and companion flange | | 1 | Each |
|---|
| 113 | 113 | Supplying all labour T&P, providing Flanged Joints conforming to IS : 3114-1994 to flanged cast iron pipes and fittings of the following nominal diameter inculding testing of joints, cost of bolts and nuts and rubber insertations as per specifications complete \n200mm Dia. MS Flange | | 10 | Each |
|---|
| 114 | 114 | 150mm Dia. MS Flange | | 10 | Each |
|---|
| 115 | 115 | 100mm Dia. MS Flange | | 15 | Each |
|---|
| 116 | 116 | Flame cutting and facing of MS plate upto 8mm thick as per specification complete. | | 14.5 | Mtr. |
|---|
| 117 | 117 | Providing joints by welding with two welding beads / pass,conforming to IS-816-1998 (Fillet weld) to MS pipes and fittings at site by using welding, generator including testing of joints, as per specification complete. | | 15 | Mtr. |
|---|
| 118 | 118 | Providing & Fixing swing check type Cast Iron Reflux Valves (Non-return valves) Rating PN-1.6 with double flanged ends conforming to IS : 5312 (Part-I) - 2004 (Standard) for water works purposes for the following rating and nominal diameters as per specification complete | | 1 | Each |
|---|
| 119 | 119 | Providing & Fixing of Sluice Valve Rating PN-1.6 (IS:14846-2000) (Standard) with double flanged ends for water works purpose for the following rating & nominal dia. including cost of nuts & bolts, rubber insertation inculding cost of sluice valve as per specification complete. | | 1 | Each |
|---|
| 120 | 120 | Earth work in all kinds of soil within 50 M initial lead and 1.5 M initial lift including rough dressing and breaking clods to maximum 5cm to 7cm. And laying in layers not exceeding 0.3 M in depth and as per direction of the Engineer-in-charge. | | 234.25 | Cum |
|---|
| 121 | 121 | Filling foundation & plinth with sand well watered and rammed | | 93.7 | Cum |
|---|
| 122 | 122 | Cement concrete (1:4:8) with 4cm size Hard Granite Crusher Broken Metal | | 93.7 | Cum |
|---|
| 123 | 123 | Cement concrete (1:2:4) with 12mm size Hard Granite Crusher Broken Chips | | 93.7 | Cum |
|---|