Military Engineer Services-MES has published Repair And Maintenance Of Summer Appliances And Connected Equipment At Mil Stn Dappar Under Ge ( P ) Dappar. Submission Date for this Tender is 09-08-2021. Air Conditioner Tenders in GE (P) Dappar Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 02-Aug-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-08-2021 |
Name of Work: Repair and Maintenance of summer appliances and connected equipment at Mil Stn Dappar under GE (P) Dappar | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Servicing of solar water heating plant at site complete, opening of all tubes descaling and replacing broken/ u/s panel making good surface and fixing in original position, opening of water heating tank cleaning, replacing heating element of 2x 3KW as per existing model/size and making leak proof and testing to the entire satisfaction of Engr-in-Charge all as specified and directed by Engr-in-Charge. | 2 | Each Job | |
2 | 2 | M&L for MS pipe 40mm dia connecting, welding , smoothing and making leak proof and including insulation with puff slab 30mm thick with wire mesh to bound the puff and including applying CRPX compound and cladding with 24 gauge aluminium super quality sheet including clamping/ binding material as per site requirement/directed and testing entire work to be carried out providing material strictly of existing specifications and to the entire satisfaction of Engineer-in Charge, including dismantling of old MS pipe complete all as specified and directed by Engr-in-Charge. | 50 | RM | |
3 | 3 | Taking down carefully ceiling/ exhaust/ wall mounted fans (of any size/make) from site, transporting the same to the store for repair complete all as directed by Engineer-in-charge. Note :-Repairs will be measured and paid separately under respective items. | 360 | Each | |
4 | 4 | Hanging / fixing only ceiling fan and connecting including provision of cable from ceiling rose or connector to fan all as specified and directed by Engr-in-Charge. | 340 | Each | |
5 | 5 | Fixing only exhaust fan/ wall mounted fan and connecting including provision of cable from ceiling rose or connector to fan all as specified and directed by Engr-in-Charge.. | 20 | Each | |
6 | 6 | Strip opening to ceiling fan of any make / type / size for repair, re-assembling after replacement of defective parts and testing after repair Complete all as specified and as directed by Engineer-in-charge Note :-Parts will be measured and paid for separately as supply only under respective items repair shall and light shall be done at the MES store yard. | 280 | Each | |
7 | 7 | M&L for rewinding to ceiling fan motor of 1200mm sweep winded with winding machine with super enameled copper winding wire of existing size gauge & design including insulated sleeves & paper , varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cable of copper conductor of size 23/.0076 upto connector block ( winding wire exc 300 gm and n-exc 350gm ) Complete the above work shall be done at the MES store yard all as specified and as directed by Engineer-in-charge. | 260 | Each Job | |
8 | 8 | M&L for rewinding to ceiling fan motor of 1400/ 1500mm sweep winded with winding machine with super enamelled copper winding wire of existing size gauge & design including insulated sleeves& paper, varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cable of copper conductor of size 23/.0076 upto connector block ( winding wire exc 350 gm and n-exc 400gm ) Complete all as specified and as directed by Engineer-in-charge. The repair shall be carried out at the MES store yard. | 60 | Each Job | |
9 | 9 | Supply only the under mentioned Ball bearing suitable for 1200/ 1400/ 1500 mm sweep ceiling fans and sweep Exhaust / Padestal/ Wall mounting fan :-(a) Ball Bearing No 6201 Make : SKF/NBC/TATA. | 60 | Each | |
10 | 10 | (b) Ball Bearing No 6202 Make : SKF/NBC/TATA | 80 | Each | |
11 | 11 | (c) Ball Bearing No 6203 Make : SKF/NBC/TATA | 80 | Each | |
12 | 12 | (d) Ball Bearing No 6204 Make :SKF/NBC/TATA | 80 | Each | |
13 | 13 | Supply only gun metal bush suitable for 1200/1400/1500 mm sweep ceiling fans, all as specified and as directed by Engineer-in-charge. | 50 | Each | |
14 | 14 | Supply only Mild steel shaft of existing specifications suitable for 1200/1400/1500 mm sweep ceiling fans all as specified and as directed by Engineer-in-charge. | 30 | Each | |
15 | 15 | Strip opening to exhaust fan/padestal fan / wall mounted fan of any size / make / sweep to carry out repairs from store yard of AGE E/M to contractor’s workshop and vice vrsa and re-assembling and testing after the repairs in store yard of AGE E/M Complete all as specified and as directed by Engineer-in-charge. The above shall be done at the MES store yard | 20 | Each Job | |
16 | 16 | M&L for rewinding to Exhaust / Padestal/ Wall mounting fan motor of 225mm to 300mm sweep winded with winding machine with super enamelled copper winding wire of existing size gauge & design including insulated sleeves , paper , varnishing with ‘B’ class insulation varnish, thimbles, connection with flexible cable of copper conductor of size 23/.0076 up to connector block(winding with exc 400 gm and n-exc 450 gm) Complete all as specified and directed by Engineer-in-charge. the above shall be done at the MES store yard. | 10 | Each Job | |
17 | 17 | Description all as per Srl item No 16 here-in –before but Exhaust Fan 350/450 mm sweep Notes :- For Srl item No 1.16 & 1.17 here-in before -(i) The cost of cutting & taking out to existing old winding wire shall be deemed to be included in the unit rate of these items. Nothing extra shall be entertained on this account (ii) Spare parts like as Ball bearings , Bush & shafts etc shall be measured & paid as Supply only separately under respective items. Fixing charges of these spare parts shall deemed to be included in the unit rate quoted for these items. | 10 | Each Job | |
18 | 18 | Supply only gun metal bush of existing specifications suitable for 225/300/350/450 mm sweep Exhaust / Padestal/ Wall mounting fan all as specified and as directed by Engineer-in-charge. | 5 | Each | |
19 | 19 | Supply only Mild steel shaft of existing specifications suitable for 225/ 300/ 350/ 450 mm sweep Exhaust / Padestal/ Wall mounting fan all as specified and as directed by Engineer-in-charge.. | 4 | Each | |
20 | 20 | M&L for lath work to any type of fan for taking out bush from the lower body part of ceiling fan and replacing it with suitable size of ball bearing as per matching size to shaft making necessary bearing boring, cutting, greasing, polishing of shaft Complete all as specified and as directed by Engineer-in-charge.Note : - Supply & fixing to Bearing shall be measured and paid separately under respective item of this Schedule. | 20 | Each Job | |
21 | 21 | Replacement of unserviceable capacitor 4 MFD suitable for 415 volt AC Complete all as specified and as directed by Engineer-in-charge. Make :- DENFOS/ INDOFOS | 40 | Each | |
22 | 22 | Replacement of unserviceable capacitor 2.5/3.15 mfd suitable for 415 volt AC Complete all as specified and directed by Engineer-in-charge. Make :- DENFOS/ INDOFOS | 250 | Each | |
23 | 23 | M&L for painting to ceiling fan complete, with synthetic enamel paint by spray painting including filling cavities with filler, one coat after cleaning all dust painting with MES NO /SM NO on fans etc , complete all as specified and directed by Engineer-in-charge. | 200 | Each | |
24 | 24 | Replacement of fan blades (set of three blades) suitable for 1200/1400/1500mm sweep fan Complete all as specified and as directed by Engineer-in-charge. | 20 | Each SET | |
25 | 25 | Supply and fix in replacement M.S rod of length of 450 mm and dia 15 mm including clamp , nut & split pin suitable for 1200/1400/1500mm sweep fan Complete all as specified and directed by Engineer-in-charge. | 20 | Each | |
26 | 26 | Supply and fix in replacement rubber real suitable for 1200/1400/1500mm sweep fan complete all as specified and directed by Engineer-in-charge. | 25 | Each | |
27 | 27 | Supply and fix in replacement PVC canopy suitable for 1200/1400/1500mm sweep fan complete all as specified and directed by Engineer-in-Charge. | 20 | Each | |
28 | 28 | Supply and fix in replacement of unserviceable electronic regulator suitable for 1200/1400/1500mm sweep fan complete all as specified and directed by Engineer-in-Charge. | 40 | Each | |
29 | 29 | Supply and fix in replacement fan blade set suitable for Exhaust fan 300 to 450 mm sweep complete all as specified and directed by Engineer-in-charge. | 5 | set of three | |
30 | 30 | Taking down desert cooler of any make & size at different site / location and carrying out necessary repairs as to stop leakage and replacement of rusted nuts bolts washers etc and scrapping of old paint and removing scales from internal & external surfaces top and bottom complete and providing two coats of synthetic enamel (hammer tone) paint by spray machine over one coat of red oxide primer including writing of MES/SM NO in 3 cm height and re fixing in existing position after greasing ,oiling and servicing of fan motors pumps and making good and serviceable condition all as specified and directed by Engineer-in -Charge. | 80 | Each Job | |
31 | 31 | Supply and fix in replacement fan motor blades of capacity 1/6 HP 50HZ 220/230Volts AC Make: Orient,Khetan | 30 | Each | |
32 | 32 | Supply and fix in replacement pump 18 watt 220 volts AC electric driven suitable for 4 meter head all as specified and directed by Engineer-in -Charge. .Make : Usha/Khetan | 40 | Each | |
33 | 33 | Supply and fix in replacement dusty/worn out wool/grass pad (set of 3 nos) all as specified and directed by Engineer-in -Charge. | 80 | Set | |
34 | 34 | Supply and fix in replacement polyethylene pipe of 15mm bore high density of existing specifications all as specified and directed by Engineer-in -Charge. | 10 | RM | |
35 | 35 | Supply and fix in replacement selector switch (3 speed) of existing specifications & make | 20 | Each | |
36 | 36 | Supply and fix in replacement PVC ELBOW right angle of existing specifications all as specified and directed by Engineer-in -Charge. | 10 | Each | |
37 | 37 | Supply and fix in replacement PVC top plug 3 pin 5Amp 230 Volts all as specified and directed by Engineer-in -Charge. Make : Anchor/ SSK. | 20 | Each | |
38 | 38 | Supply and fix in replacement flexible copper conductor size 23/0.0076 3 core pvc insulated sheet | 200 | RM | |
39 | 39 | Supply and fix in replacement of worn out capacitor 4MFD , 230volts, 50Hz all as specified and directed by Engineer-in -Charge. | 20 | Each | |
40 | 40 | Taking out to unserviceable MS part body of any capacity including existing fan, motor, blades, water lifting pump and electric wiring, fitting switches etc complete all as specified and directed by Engineer-in –Charge | 20 | Each | |
41 | 41 | M& L GI steel body of desert cooler of capacity 3000cum duly painted with two coats synthetic enamelled paint on external surface and black painting with MES NO /SM NO on internal surface over one coat of red oxide primer with spray gun machine.The body of desert cooler will be fabricated as under mentioned complete all as specified and directed by Engineer-in –Charge (a) Top and bottom made out of 1.25 mm thick GI sheet. (b) side panels(set of 3) made out 1.00 mm thick GI sheet with wood wool pads and wire mesh of GI wire 1.4 mm dia 2.5 mm mesh for holding pads. (c) Front grill of suitable size and approved quality GI sheet. (d) Re fixing serviceable existing fan water lifting pump, fan, motor, blades, wiring, fittings etc\n. NOTE: Unserviceable parts shall be replaced with new serviceable parts and shall be paid as supply only under respective items of this schedule. | 25 | Each Job | |
42 | 42 | Supply and fix in replacement desert cooler side panels(set of 3) as per existing approx. size 60x70 cm made out of 22 SW9 GI sheet with handle all as specified and directed by Engr - in Charge. | 60 | Set | |
43 | 43 | M&L in replacement front show grill approx. size 55x60 cm for any make type of desert coolers having provision for rotary selector switch and toggle switch complete all as specified and directed by Engineer-in -Charge. | 30 | Each | |
44 | 44 | Disconnecting to unserviceable sealed compressor of 1.5 Ton capacity window type AC and M& L replaced with new company sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system & testing the leaking with gas charging etc complete all as specified and directed by Engineer-in-charge. Make : LG / Hitachi/ Voltas | 2 | Each job | |
45 | 45 | Description all as per above item No 44 here-in-before but 1.5 Ton capacity split type AC. Make : LG / Hitachi/ Voltas. | 1 | Each job | |
46 | 46 | M& L Recharging of gas R-22 in air conditioner unit window type 1.5/2 ton complete including testing of leakage and testing & servicing the unit for satisfactory performance Complete all as specified and directed by Engineer-in-Charge. | 4 | Each Job | |
47 | 47 | Supply and fix in replacement thermostat switch suitable for window type AC 1.5/2 Ton capacity. Complete all as specified and as directed by Engineer-in-Charge. Make : Renutrol/ Indfos | 1 | Each | |
48 | 48 | Supply and fix in replacement starting capacitor 100-200 mfd suitable for window/split type AC of any capacity complete all as specified and as directed by Engineer-in-Charge. Make : Usha / SIEMEN | 4 | Each | |
49 | 49 | Supply and fix replacement running capacitor 36 MFD suitable for window/ split type AC of any capacity complete all as specified and directed by Engineer-in-Charge.Make : Usha / SIEMEN | 1 | Each | |
50 | 50 | Supply and fix in replacement thermo-stat switch suitable for split type AC 1.5/2Ton capacity complete all as specified and as directed by Engineer-in-Charge.Make : Rentrol/ Indfoss. | 2 | Each | |
51 | 51 | Supply and fix in replacement over load protector suitable for split type AC 1.5/2Ton capacity complete all as specified and directed by Engineer-in-Charge Make : Renutrol/ Indfoss. | 2 | Each | |
52 | 52 | Disconnecting and taking out worn out/unserviceable sealed compressor of water cooler of capacity 40/80 ltrs and M& L replacing with new sealed compressor of existing capacity and size including soldering of suction and discharge line gas pipe and flushing the complete system and making leak proof all as specified and directed by Engineer-in-charge. Make : LG/ HITACHI/ VOLTAS. | 2 | Each job | |
53 | 53 | Cleaning the system with CRC and charging the refrigerant gas R-22/M22 including replacement of strainer filter suitable for water cooler of 40/80 litres capacity complete all as specified and directed by Engineer-in-charge. | 2 | Each Job | |
54 | 54 | Supply and fix in replacement Starting relay assembly suitable for water cooler of 40/80 liter capacity Complete all as specified and directed by Engineer-in-Charge | 2 | Each | |
55 | 55 | Material & Labour internal wiring for water coolers 80/40 ltr capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers etc required for fastening with body etc complete all as specified and directed by Engineer-in-charge.Make : Kalinga/Finolex/Plaza. | 1 | Each job | |
56 | 56 | Supply and fix in replacement Starting capacitor 40-60 mfd assembly all as specified and directed by Engineer-in-Charge | 2 | Each | |
57 | 57 | Supply and fix in replacement Running capacitor 10 mfd assembly all as specified and directed by Engineer-in-Charge. | 2 | Each | |
58 | 58 | Supply and fix in replacement over load protector complete all as specified and directed by Engineer-in-Charge Make :-- Renutral/ Indfos | 1 | Each | |
59 | 59 | Supply and fix in replacement drain hose pipe 40mm dia suitable for water cooler of 40/80 liter capacity complete all as specified and directed by Engineer-in-Charge Make : Renutral/ Indfos | 2 | Each | |
60 | 60 | Supply and fix in replacement clamp for fan motor of 1/16 to 1/32 hp hose pipe complete all as specified and directed by Engineer-in-Charge Make : Renutral/ Indfos | 1 | Each | |
61 | 61 | Supply and fix in replacement fan blade plastic for fan motor 1/32 hp complete all as specified and directed by Engineer-in-Charge. | 1 | Each | |
62 | 62 | Supply and fix in replacement clamp for hose pipe complete all as specified and directed by Engineer-in-Charge. | 2 | Each | |
63 | 63 | Supply and fix in replacement fan motor with new one suitable for water cooler of capacity 40/80 ltrs complete all as specified and directed by Engineer-in-Charge. Make : Cool home/ AUE | 1 | Each | |
64 | 64 | Supply and fix in replacement self closing tap push type 15 mm bore of cast copper alloy chromium plated fixed to water cooler as in repair complete all as specified and directed by Engineer-in-Charge. | 2 | Each | |
65 | 65 | Supply and fix in replacement thermo-stat switch with new one complete all as specified and directed by Engineer-in-Charge. Make :-- Renutral/ Indfos/Dasspass | 20 | Each | |
66 | 66 | Disconnecting to unserviceable sealed compressor for 330 ltr capacity of refrigerator and M & L replaced with new company sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system arresting the leaking etc complete all as specified and directed by Engineer-in-charge Make : Godrej/ LG/ VOLTAS. | 1 | Each job | |
67 | 67 | Disconnecting to Unserviceable Freezer door of capacity 300 ltr refrigerator and M & L Replace the Freezer door plastic with tension spring of existing model suitable 300 liter cap refrigerator. | 1 | Each | |
68 | 68 | Dismantling of unsv float valve assy and supply and fixing PVC float valves complete assy 15 mm size complete all as specified and directed by Engr-in-Charge. | 2 | Each | |
69 | 69 | Supply and fix in PVC connection pipe with male female sockets 45 cm long for water cooler 40/80 ltr capacity complete all as specified and directed by Engineer-in-charge. | 2 | Each | |
70 | 70 | M & L Cleaning the system with CRC and charging the refrigerant gas R-134 including replacing strainer and rectification of leakage in the system from refrigerator 330 litres capacity complete all as specified and directed by Engineer-in-charge. | 2 | Each Job | |
71 | 71 | Supply and fix in replacement starting relay assembly suitable for refrigerator 330 litres capacity complete all as specified and directed by Engineer-in-Charge. | 1 | Each | |
72 | 72 | Supply and fix in replacement Starting capacitor 40-60 mfd assembly suitable for refrigerator 330litres capacity Complete all as specified and directed by Engineer-in-Charge | 1 | Each | |
73 | 73 | Supply and fix in replacement over load protector suitable for refrigerator 330 litres capacity Complete all as specified and directed by Engineer-in-Charge Make : Renutral/ Indfoss. | 1 | Each | |
74 | 74 | Supply and fix in replacement thermo-stat switch suitable for refrigerator any capacity Complete all as specified and as directed by Engineer-in-Charge. Make :-- Renutral/ Indfoss | 20 | Each | |
75 | 75 | Supply and fix in replacement heating element with capacity 2KW suitable for geyser 50ltrs all as specified and directed by Engineer-in-charge. | 30 | Each | |
76 | 76 | Supply and fix in replacement heating element with capacity 1KW suitable for geyser 25ltrs all as directed by Engineer-in-charge. | 6 | Each | |
77 | 77 | Supply and fix in replacement Thermostat suitable for geysers 25 to 50 Ltrs complete all as specified and directed by Engineer-in-charge. | 30 | Each | |
78 | 78 | Supply and fix in replacement Pressure release valve of existing specification & make for geysers of cap 25 to 50 Ltrs complete all as specified and directed by Engineer-in-Charge. | 20 | Each | |
79 | 79 | Preparation surface for painting and painting of geysers cap 25/50Ltrs with 2 coats of synthetic enamel painting with MES NO /SM NO in situ complete all as specified and directed by Engineer-in-Charge | 20 | Each Job | |
80 | 80 | Supply and fix in replacement copper tank of existing specifications & make suitable for cap of 25 ltrs geyser complete all as specified and directed by Engineer-in-Charge. | 10 | Each | |
81 | 81 | Supply and fix in replacement copper tank of existing specifications & make suitable for cap of 50 ltrs geyser complete all as specified and directed by Engineer-in-Charge. | 1 | Each | |
82 | 82 | Supply and fix in replacement Gun Metal non return valve size of 15 mm of existing make for geysers of cap 25 / 50 Ltr complete all as specified and directed by Engineer-in-Charge. | 30 | Each | |
83 | 83 | Supply and fix in PVC connection pipe with male female sockets 45 cm long for geyser 25/50 ltrs capacity complete all as specified and directed by Engineer-in-charge. | 80 | Each Set | |
84 | 84 | Supply and fix in replacement Sheet metal enclosure with socket plug top and MCB SPN cap 32 Amps with a 2 pin, earth plug and socket complete all as specified and directed by Engineer-in-Charge. Make : Indo Asian/ Havells/ Legrand | 40 | Each Point | |
85 | 85 | Dismaintling of voltage stablizer and various components of automatic voltage corrector of any rating but cap not exceeding 5 KVA, single phase , 50 Hz including locating the faults complete all as specified and directed by Engineer-in-Charge. | 6 | Each Job | |
86 | 86 | Dismaintling of burnt U/S main transformer copper wound and stamping and material and labour for re-assembling the stemping and re-winding of main transformer, single phase, 50 Hz with super enamelled copper winding wire of existing size, design & weight SWG turns / tapping and varnishing complete of voltage stablizer cap up to 4 KVA, complete all as specified and directed by Engineer-in-Charge. | 2 | Each Job | |
87 | 87 | Description all as per Ser item No 86 here-in-before but 5 KVA all as specified and directed. | 3 | Each Job | |
88 | 88 | Description all as per Ser item No 86 here-in-before but 3 KVA all as specified and directed Engineer-in-Charge. | 1 | Each Job | |
89 | 89 | S&F (in replacement) voltage regulator PCB for voltage stabliser for power rating 5KVA complete all as specified and directed by Engr -in-Charge. | 2 | Each Job | |
90 | 90 | Description all as per Ser item No 89 here-in-before but for power rating 4 KVA all as specified and directed by Engr -in-Charge. | 2 | Each Job | |
91 | 91 | Description all as per Ser item No 89 here-in-before but for power rating 3 KVA all as specified and directed by Engr -in-Charge. | 1 | Each Job | |
92 | 92 | Material & Labour PVC cable flexible 3 core size 70 / 0.0076 all as specified and directed by Engr -in-Charge. | 100 | RM | |
93 | 93 | Material & Labour 3 pin plug top 15 Amp, 250 Volt, complete all as specified and directed by Engr -in-Charge. Make : Anchor / SSK / Fine. | 15 | Each | |
94 | 94 | Disconnecting to unserviceable sealed compressor of deep freezer of capacity 300 liter and M& L replaced with New sealed compressor of existing capacity & model including soldering of liquid /gas pipeline,cleaning the system arresting the leaking etc complete all as specified and directed by Engineer-in-charge Make :-- Sri-Ram/ Tikamshah/ Kirloskar | 1 | Each job | |
95 | 95 | M& L Cleaning the system with CRC and charging the refrigerant gas R-134 including replacing strainer and rectification of leakage in the system from deep freezer of 300 litres capacity complete all as specified and as directed by Engineer-in-charge. | 1 | Each Job | |
96 | 96 | M& LCleaning to internal surfaces of deep freezer of 300 litres capacity suitable repairs to body to stop leakage etc, replacing unserviceable nuts bolts & washers etc including preparation of external surfaces of body and painted with anticorrosive synthetic enamel paint with help of spray gun machine over a coat of red oxide and writing SM / MES No in 3cm height Complete all as specified and as directed by Engineer-in-Charge. | 1 | Each job | |
97 | 97 | S&F in replacement starting relay assembly suitable for deep freezer of 300 litres capacity complete all as specified and as directed by Engineer-in-Charge | 2 | Each | |
98 | 98 | Material & Labour internal wiring for deep freezer of 300 litres capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers etc required for fastening with body etc complete all as specified and as directed by Engineer-in-charge.Make :-- KALINGA/ FINOLEX/PALAZA | 1 | Each job | |
99 | 99 | Supply and fix in replacement Starting capacitor 40-100 mfd assembly suitable for deep freezer of 300 litres capacity Complete all as specified and as directed by Engineer-in-Charge | 1 | Each | |
100 | 100 | Supply and fix in replacement Running capacitor 10-20 mfd suitable for deep freezer of 300 litres capacity Complete all as specified and as directed by Engineer-in-charge | 1 | Each | |
101 | 101 | Supply and fix in replacement over load protector suitable for deep freezer of 300 litres capacity Complete all as specified and as directed by Engineer-in-Charge Make :-- Renutral/ Indfoss | 1 | Each | |
102 | 102 | Supply and fix in replacement Drain hose pipe 40mm dia suitable for deep freezer of 300 litres capacity Complete all as specified and as directed by Engineer-in-Charge Make : Renutral/ Indfoss | 1 | Each | |
103 | 103 | Supply and fix in replacement Clamp for fan moter for 1/16 to 1/32 hp hose pipe suitable for Clamp for hose pipe deep freezer of 300 litres capacity Complete all as specified and as directed by Engineer-in-Charge Make :-- Renutral/ Indfos | 1 | Each | |
104 | 104 | Supply and fix in replacement fan blade plastic for fan moter 1/32 hp suitable for fan blade plastic for fan moter 1/32 hp deep freezer of 300 litres capacity Complete all as specified and as directed by Engineer-in-Charge Make :-- Renutral/ Indfos | 1 | Each | |
105 | 105 | Supply and fix in replacement clamp for hose pipe suitable for clamp for hose pipe deep freezer of 300 litres capacity complete all as specified and as directed by Engineer-in-Charge Make :-- Renutral/ Indfoss | 1 | Each | |
106 | 106 | Supply and fix in replacement fan motor suitable for deep freezer of 300 litres capacity Complete all as specified and as directed by Engineer-in-Charge.Make :-- Cool home/ AUE | 1 | Each | |
107 | 107 | Supply and fix in replacement condensor coil suitable for deep freezer of 300 litres capacity complete all as specified and as directed by Engineer-in-charge. | 1 | Each | |
108 | 108 | Supply and fix in replacement thermostat switch with new thermostat switch suitable for deep freezer any capacity complete all as specified and as directed by Engineer-in-charge. Make :-- Renutral/ Indfoss | 1 | Each | |
109 | 109 | Supply and fixing in replacement MCB SP 6 -32 Amps,10 KA, 'C' series 240 V ISI marked complete all as specified and directed by Engineer-in-charge. MAKE : Legrand/ABB/Schenider | 30 | Each | |
110 | 110 | Supply and fixing in replacement MCB SPN 06-32 Amps,10 KA 'C' series 240 V ISI marked.complete all as specified and directed by Engineer-in-charge. Make: Legrand/ABB/Schenider | 20 | Each | |
111 | 111 | Supply and fixing in replacement MCB TPN 63 Amps,10 KA 'C' series 240 V ISI marked.complete all as specified and directed by Engineer-in-charge. Make: Legrand/ABB/Schenider | 15 | Each | |
112 | 112 | Taking down existing old unserviceable puf insulation from MS pipe and Material and labour for insulation over a existing MS pipe of size 80mm dia with puff slab 30mm thick with wire mesh to bound the puff and including applying CRPX compound and cladding with 24 guage alluminium super quility sheet including clamping/ binding material, testing as per site requirment and directed by Engr-in-charge. | 30 | RM |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail