| 1 | 1 | Taking down old unserviceable overhead ACSR conductors from existing overhead lines / poles and depositeion in store of KV, complete all as directed by Engineer-in-Charge. | 1 | 0.32 | Qtl |
|---|
| 2 | 2 | Excavation in trenches for foundations, erecting poles or laying of cable, not exceeding 1.5 mtr in depth and not exceeding 1.50 metre in width in hard / dense soil complete all as specified and directed. | 2 | 140 | Cum |
|---|
| 3 | 3 | All as per the description of serial item No 2 herein above but depth exe 1.5 mtr but not exe 3.0 mtr. | 3 | 0.18 | Cum |
|---|
| 4 | 4 | Returning filling in soil including spreading leveling, watering and well ramming in layer not exceeding 25 thick complete all as specified and directed | 4 | 114 | Cum |
|---|
| 5 | 5 | Removing excavated surplus soil to a distance exceeding 50 mtr and not exceeding 100 metre and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. | 5 | 26.18 | Cum |
|---|
| 6 | 6 | Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate), as in foundations, filling and mass concrete complete all as specified and as directed | 6 | 0.18 | Cum |
|---|
| 7 | 7 | Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate), as in foundation filling and mass concrete complete all as specified and as directed | 7 | 2.7 | Cum |
|---|
| 8 | 8 | Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate), as in coping benching, bed plate and like with slightly rounded or chamfered angles including necessary form work as required complete all as specified and as directed | 8 | 1 | Cum |
|---|
| 9 | 9 | Material and labour for supply, erection and fixing in position 9.00 metre long, Steel tubular swaged poles complete with mild steel base plate, flat top welded type 410, SP-31 IS 2713 marked, drilling of necessary holes including bolts, nuts and washers as requried and painted with two coats of Aluminium paint over a coat of red oxide primer on exposed surfaces of poles and two coats of black bituminous paint throughout internally and externally upto the planting depth including painting 30 cm wide strips upto 1.20 m height from ground level in yellow and black colour synthetic enamel paint in alternate and marking numbering of pole at height and pattern as directed by Engineer-in-Charge complete all as specified and directed. Note : Excavation and earth work and concrete work shall be measured and paid for seperately. | 9 | 5 | Each |
|---|
| 10 | 10 | Street light mounting bracket suitable for LED fittings of length 1.50 mtre, mde out of light grade GI pipe of 50mm bore, bent to shape (120 degree ) as directed by Engineer -in-Charge complete with two Nos GI clamp made to shape out of 50mm X 6mm flat iron with GI nuts, bolts and washers of suitable size for fixing on pole/wall, fixed to pole/ wall complete all as specified and as directed including taking down old damaged bracket and remving from site of work complete all as directed. | 10 | 14 | Each |
|---|
| 11 | 11 | S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending (cold or hot) drilling holes for bolts bent to any shape or size as indicated or directed and inclusive of one primer coat of red oxide zinc chromate one under coat and one finishing coat of aluminium paint complete all as specified and as directed. | 11 | 0.1 | Qtl |
|---|
| 12 | 12 | Non metallic Junction box made out of PVC sheet of thickness of size not less than 240mm x130mmx110mm hinged with lockable arrangement with and including aluminium bus bar TPN capacity 200 Amp with one No MCB 2.5 Amp SP 10 KA 'C' curve with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole or grouting in PCC muff complete all as specified and directed. | 12 | 19 | Each |
|---|
| 13 | 13 | S&L cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core laid in tranches or under floors or fixed along pole or passing through ducts complete all as specified and directed. \nNote : Excavation and earthwork, if any, shall be measured and paid for seperately. | 13 | 600 | RM |
|---|
| 14 | 14 | All as per the description of serial item No 13 herein above but size 240.00 Sqmm 3.50 Core. \nNote : Excavation and earthwork, if any, shall be measured and paid for seperately. | 14 | 200 | RM |
|---|
| 15 | 15 | Dry coarse sand in trenches as cushion to cable complete all as specified and as directed | 15 | 12 | Cum |
|---|
| 16 | 16 | Supply and laying unreinforced precast concrete cable cover (ISI marked) class LV, type-1, flat size 250mmx150mmx40mm in trenches over sand as protection to cable complete all as specified and as directed. | 16 | 900 | Each |
|---|
| 17 | 17 | Supply and laying double walled corrugated HDPE duct pipe of 40mm outer dia confirming to IS 14930 Pt II with antirodent and non flame propergating properties of approved colour complete with fitting for cable protection complete all as specified and as directed. | 17 | 550 | RM |
|---|
| 18 | 18 | Multi stranded copper cable PVC insulated unsheathed 1100 volts grade of size 2.50 sqmm 3.00 core for connection from junction box to light fitting and making connections and testing for functioning of light fitting complete all as directed | 18 | 150 | RM |
|---|
| 19 | 19 | Supply and fix high power LED street light fittings energy saving luminaire, with system wattage 90 watt with system efficacy (lm/w) not less than 100 lumens per watt, total system lumen not less than 9000 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5700K +300K, high pressure die cast aluminium alloy LM6 housing heat sink for better heat transmission with epoxy powder coated IP-66 class 1 protection, toughened glass cover, well designed thermal management system , driver efficiency > 85% with constant output of current and voltage against input voltage variation 100 to 270 volt at 50 Hz ( + 5%), THD< 10%. The driver should bebe potted with electrolytic capacitor of min 105 degrees ratings and must be with phase protection, external SPD should be of minimun 10 KV capacity, complete including taking down old unserviceable CFL/T-5/HPSV lights of any size/type all as directed. | 19 | 20 | Each |
|---|
| 20 | 20 | Supply and fix LED post top lantern Light fitting with Maximum system wattage of 40 Watt, system lumen efficacy not less than 80 lumens per watt, total system lumens not less than 3200 lumens , PF>0.90 ,CRI not less than 70, THD not more than 20%, surge protection not less than 5 KV, colour temp 5700 k to 6500k, operating voltage ranging from less than 120V to more than 270 V at 50 Hz AC frequency, glare free elagently designed highly efficient Pressure die cast aluminium housing cum heat sink circular conpoy and clear acrylic cover for 360 degree indirect, uniform light disribution, Delivers high light output. IP 66 Class -I, complete all as specified and directed . | 20 | 2 | Each |
|---|
| 21 | 21 | Supply and fix LED Flood Light luminaire with lens Maximum system wattage of 150 Watt, system lumen efficacy not less than 90 lumens per watt, total system lumens not less than 13500 lumens , PF>0.90 ,CRI not less than 70, THD not more than 20%, surge protection not less than 5 KV, colour temp 5700 k to 6500k, operating voltage ranging from less than 120V to more than 270 V at 50 Hz AC frequency, glare free elagently designed highly efficient Pressure die cast aluminium housing in powder coated finish heat resistant toughened glass , gasket provides high degree of protection . Delivers high light output. Fins provided on housing for better dessipation luminaire IP 66 Class -I, complete all as specified and directed . | 21 | 10 | Each |
|---|
| 22 | 22 | Supply and fixing in replacement of 63 amp automatic street light switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of Natural light. Sensor alongwith suitable power coontactors and incoming - outgoing MCB should be enclosed and supported terminal should be enclosed in pole/wall mountable enclousure made of rust proof, electric shock proof, terminal proof and FR grade special moulding compound conforming to IP 66 protection class 2 enclosure made of thermoplastic polycarbonate and protected against weather influences all as specified and directed. Make of switch and MCB : Siemens/L&T/ ABB/Schenider/Legrand/Hager/Havells/Crompton Greaves/HPL/ Standard Electricals or equivalent. (a) Three phase load of 5 KW with : 3 Nos Contactors, 3 Nos incoming MCBs & 3 Nos outgoing MCBs of 16-20 Amps each & circuit wiring (copper) of min 10 sqmm. (b) Earth terminals - 02 Nos. | 22 | 1 | Each |
|---|
| 23 | 23 | M&L for painting of steel poles 9 m long with two coats of aluminium paint including cross arms , clamps & brackets fitted on pole all as directed by Engineer-in-Charge including providing reflective strips of width 10cm, upto1.20 meter height from ground level, of colour green and white in alternate complete all as specified and directed. | 23 | 14 | Each |
|---|