Rejuvenation, Renovation, Modernization And Strengthening Of Various Units And Providing Functional House Water Connection With One Year Defect Liability Period At Wss 24 O Under Jjm In The Jurisdiction Of Sub Divison Srikaranpur Under Phed Distt. Div, Srikaranpur-Rajasthan

Public Health Engineering Department-PHED has published Rejuvenation, Renovation, Modernization And Strengthening Of Various Units And Providing Functional House Water Connection With One Year Defect Liability Period At Wss 24 O Under Jjm In The Jurisdiction Of Sub Divison Srikaranpur Under Phed Distt. Div. Submission Date for this Tender is 05-08-2021. Water Pipe Line Tenders in Srikaranpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

28486633
Rejuvenation, Renovation, Modernization And Strengthening Of Various Units And Providing Functional House Water Connection With One Year Defect Liability Period At Wss 24 O Under Jjm In The Jurisdiction Of Sub Divison Srikaranpur Under Phed Distt. Div
Open Tender
Indian
Rajasthan
Srikaranpur
05-08-2021

Tender Details

Rejuvenation, Renovation, Modernization and strengthening of various units and providing Functional House water connection with one year Defect Liability period at WSS 24 O under JJM in the jurisdiction of Sub Divison SriKaranpur under PHED Distt. Div. SriGanganagar

Key Value

Document Fees
INR 2000 /-
EMD
Refer document
Tender Value
INR 1.22 Crore /-

BOQ Items

Name of Work: Rejuvenation, Renovation, Modernization and strengthing of various units and providing Functional House water connection with one year Defect Liability period at WSS 24 'O' under JJM in the jurisdiction of Sub Divison SriKaranpur under PHED Distt. Div. SriGanganagar
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Repairing of existing Storage Tanks BI01010001010000000000000515BI0100001112
2 2 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. \nAll kinds of soils BI01010001010000000000000515BI0100001113 55 Cum
3 3 Silt clearance from Sedimentation cum storage tank with lift upto 4.5 Mtr. and lead upto 50 Mtr. Silt to be disposed outside of Headworks Boundaries. Disposed silt to be levelled and neatly dressed including stacking of useful material if any available during excavation for all kind of soil. Silt to be carried out by means of mechanical system i.e. Tractor craw/Trolly or any other mechanical system. No extra payment shall be done for lift of any limit. This work also involves dressing of bottom purposed which is to be done mannually to be maintained as per direction of Engineer In Charge. BI01010001010000000000000515BI0100001114 700 Cum
4 4 Add extra for every additional lead up to 500 mtr BI01010001010000000000000515BI0100001115 700 Cum
5 5 Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. BI01010001010000000000000515BI0100001116 500 Sqm
6 6 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand) : Flush / Ruled/ Struck or weathered pointing. \n BI01010001010000000000000515BI0100001117 2000 Sqm
7 7 “Preparing surface leveled and dressed to proper slope and lying over it tibba sand properly rammed and watered in to layers of 5cm each. Providing & lying ISI marked 250 micron LDPE film as per ISS : 2508-1984 including interlocking by using thermal welding or ultrasonic welding are sealing tapes on the finished surface compacted tibba sand. LDPE film to be anchored in parapet/Toe wall or any other structure etc as per direction. Over the LDPE film 15mm thick cement bajri mortar 1:3 shall be provided & laid. Over this mortar single layer Ist class flat brick lining in cement bajri mortar 1:3 shall be provided with joints not more than 8mm wide. It includes providing weedicides and anti-termite treatment as per specification “ and curing. Measurement of lining area will be payable. (Film used in anchoring is not payable) BI01010001010000000000000515BI0100001118 1500 Sqm
8 8 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar. BI01010001010000000000000515BI0100001119 50 Cum
9 9 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 meters (stacks of cleaned bricks ahall be measured): From brick work in Cement mortar. BI01010001010000000000000515BI0100001120 14400 Nos
10 10 Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in foundation and plinth with Cement mortar 1 : 6 (1 cement : 6 coarse sand) BI01010001010000000000000515BI0100001121 140 Cum
11 11 Plaster on new surface on walls in cement sand mortar 1:4 including raking of joints etc. complete fine finish: 12 mm thick. BI01010001010000000000000515BI0100001122 800 Sqm
12 12 Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 20mm thick . BI01010001010000000000000515BI0100001123 750 Sqm
13 13 Finishing wall with water proffing cement paint of approved brand and manufacture and of required shade to give an even shade including all scaffolding new work 3 or more coals. BI01010001010000000000000515BI0100001124 800 Sqm
14 14 Recovery of old Bricks BI01010001010000000000000515BI0100001125 14400 Nos
15 15 Providing and Fixing of PVC float arm with PVC flexible hose pipe 7.5 Mtr long and 150 mm dia. This also included tail pieces 150 mm dia on pipe's side and tail piece of required shape and 150 mm dia as hose pipe end for fixing float arm. All material should be confirming to relevant IS code. PVC float should be of capacity 100 Ltr. minimum. This job also includes dismantling of old system from storage tank. supply and fixing complete work in all respect. BI01010001010000000000000515BI0100001126 3 Job
16 16 Providing and fixing in position CI Puddle collar (approx. 1m length) inside the wall including all material labour as per Technical Specification of concerned IS Code 210-1978 (IS 1538:1993) and as per direction of Engineer:- 150 mm dia BI01010001010000000000000515BI0100001127 3 Each
17 17 Providing, Laying, Jointing & Commissioning of Rising Mains BI01010001010000000000000515BI0100001128
18 18 Providing , supplying, lowering and laying instandard lengths HDPE PE-80 PN-6 pipes conforming to IS 4984 :1995 with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ Compression fitting joint or flanged joint and specials jointing pipes by butt fusion welding method, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/unloading charges, stacking the same in closed shade duly protecting from sunrays and rains, including cost of labour and material, specials tee, bends etc., satisfactory hydraulic testing etc., complete as per technical speciafications and directions of Engineer-In-Charge (excluding earthwork) PE-80/PN-6, for internal village distribution network\n110 mm BI01010001010000000000000515BI0100001129 5250 Mtr.
19 19 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. BI01010001010000000000000515BI0100001130 5250 mtr
20 20 Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. '---------------------- do --------------- 100mm\nNote: Rates are exclusive of tail piece/ dismantling joints and earth work. BI01010001010000000000000515BI0100001131 5 Each
21 21 Providing of all size CI Flanged Special like Tees, Bends, Reducers and Enlargers as per IS: 1538-1993 (amended up to date) requiring for laying, testing and commissioning of AC Pipe line as per Technical Specifications and as per direction of Engineer. BI01010001010000000000000515BI0100001132 115 Kg
22 22 Part B "Bulk Meeter" BI01010001010000000000000515BI0100001133
23 23 Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. 65 mm dia BI01010001010000000000000515BI0100001134 3 No
24 24 Part C VTC BI01010001010000000000000515BI0100001135
25 25 Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 meter. All kinds of soil. BI01010001010000000000000515BI0100001136 23.6682 Cum
26 26 Providing and laying cement concrete inclusing curring compaction etc. complete using stone aggregate 20mm nominal size in foundation, plinth excluding the cost of shuttering using 1 cement : 4 send :8 aggregate mix(Without vibrator). BI01010001010000000000000515BI0100001137 1.73587 Cum
27 27 Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in foundation and plinth with Cement mortar 1 : 6 (1 cement : 6 coarse sand) BI01010001010000000000000515BI0100001138 27.759 Cum
28 28 Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification .50mm thick. BI01010001010000000000000515BI0100001139 10.479 sqm
29 29 Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) BI01010001010000000000000515BI0100001140 5.451 Cum
30 30 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.\nM20 grade Nominal Mix / Design Mix BI01010001010000000000000515BI0100001141 22.1235 Cum
31 31 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Cold twisted deformed bars (IS : 1786). BI01010001010000000000000515BI0100001142 232.11 Kg
32 32 Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of formwork for superstructure up to 4.5 mtr above plinth, for:Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands , coping, bed plates, anchor blocks, sills, chhajjas lintel, beam etc. BI01010001010000000000000515BI0100001143 17.3498 Sqm
33 33 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 12mm thick. BI01010001010000000000000515BI0100001144 183.984 Sqm
34 34 Finishing with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade on new work { three or more coats } BI01010001010000000000000515BI0100001145 183.984 Sqm
35 35 Providing precast cc jali nominal mix 1:2:4 reinforced with 1.6 mm dia m.s. wire including centering, shuttering, roughening, cleaning, fixing & finishing in cement mortar 1:3 etc. complete as per approved design excluding plastering of jambs, sills & soffits, upto floor three level:40 mm thick. BI01010001010000000000000515BI0100001146 0.27 sqm
36 36 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001147 75 Kg
37 37 Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint BI01010001010000000000000515BI0100001148 4.5 sqm
38 38 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. BI01010001010000000000000515BI0100001149 90 Kg
39 39 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm thick nominal size aggregate. BI01010001010000000000000515BI0100001150 5.085 sqm
40 40 Part D Air valve BI01010001010000000000000515BI0100001151
41 41 Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 meter. All kinds of soil. BI01010001010000000000000515BI0100001152 6.5 Cum
42 42 Providing and laying cement concrete inclusing curring compaction etc. complete using stone aggregate 20mm nominal size in foundation, plinth excluding the cost of shuttering using 1 cement : 4 send :8 aggregate mix(Without vibrator). BI01010001010000000000000515BI0100001153 0.305 Cum
43 43 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) BI01010001010000000000000515BI0100001154 125 kg
44 44 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). BI01010001010000000000000515BI0100001155 3.5 Cum
45 45 Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). BI01010001010000000000000515BI0100001156 1.5 Cum
46 46 Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of formwork for superstructure up to 4.5 mtr above plinth, for:Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands , coping, bed plates, anchor blocks, sills, chhajjas lintel, beam etc.Columns, pillars, posts and struts etc. BI01010001010000000000000515BI0100001157 35 Sqm
47 47 P & F G.I. Pipes with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. :-\n( External Work ) Medium Duty Pipes 50mm dia nominal bore BI01010001010000000000000515BI0100001158 20 Mtr
48 48 Clamps and M.S. stays including bolts and nuts for 50 mm pipe BI01010001010000000000000515BI0100001159 5 Each
49 49 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air Valve Flanged/ Screwed type of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended upto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1,Body seat ring - Leaded tin bronze/ SS , Seal ring and face ring - EPDM/NBR, Ends flanged according to IS:6418 or screwed type shall have external pipe threads conforming to IS:554, Fasteners - CS. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of paint conforming to IS:9862 or IS:2932( Non-Toxic- suitable for drinking water) applied inside and outside. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.\nNote: Rates are exclusive of connecting tee, pipe piece and earth work. BI01010001010000000000000515BI0100001160 5 Each
50 50 Providing Fitting & Fixing of Pumpset. BI01010001010000000000000515BI0100001161
51 51 Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 operating at sync. speed 2900 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee. 5.0 HP BI01010001010000000000000515BI0100001162 2 Set
52 52 Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 operating at sync. speed 2900 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee.750 LPM 40 meter Head 15 HP BI01010001010000000000000515BI0100001163 2 Set
53 53 Providing and fixing double flanged ISI marked GI pipes (external works) with GI fittings excluding valves (IS:1239 mark) and MS clamps, as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing\nclamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 80 mm BI01010001010000000000000515BI0100001164 48 Mtr
54 54 Providing and fixing double flanged ISI marked GI pipes (external works) with GI fittings excluding valves (IS:1239 mark) and MS clamps, as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing\nclamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 100 mm BI01010001010000000000000515BI0100001165 60 Mtr
55 55 Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. \nNote: Rates are exclusive of tail piece/ dismantling joints and earth work.80 mm BI01010001010000000000000515BI0100001166 4 Each
56 56 Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. '---------------------- do --------------- 100mm\nNote: Rates are exclusive of tail piece/ dismantling joints and earth work. BI01010001010000000000000515BI0100001167 4 Each
57 57 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per approved make complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. (Nominal Dia. in mm) 100 mm dia BI01010001010000000000000515BI0100001168 4 Each
58 58 Providing of all size CI Flanged Special like Tees, Bends, Reducers and Enlargers as per IS: 1538-1993 (amended up to date) requiring for laying, testing and commissioning of AC Pipe line as per Technical Specifications and as per direction of Engineer. BI01010001010000000000000515BI0100001169 350 Kg
59 59 Structural Steel work welded in built up section, trusses and frame work including cutting, hoisting, fixing, fixing in position and applying a priming coat of approved steel primer upto 4.5 Mtr. Hight above plinth level in RS Joists, flats, tees, angles & channels BI01010001010000000000000515BI0100001170 250 Kg
60 60 Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of black Japan paints conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside. Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410, Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. \nNote: Rates are exclusive of tail piece/ dismantling joints and earth work.80 mm dia BI01010001010000000000000515BI0100001171 4 Each
61 61 Providing, installation, testing and commissioning of Mono block Vacuum pump set with base plate including C.C. foundation / cross channels / RSJ frame and foundation bolts etc complete in all respect as per specification, scope of work and direction of Engineer in Charge.3 HP, three Ph BI01010001010000000000000515BI0100001172 1 Each
62 62 Supply of 50mm dia G.I. medium class pipe (each length 5.8 m to 6.0 m) tripod as per drawing and design with chain pulley of 3 Mt. capacity. BI01010001010000000000000515BI0100001173 1 Each
63 63 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix \n1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). BI01010001010000000000000515BI0100001174 5.2 Cum
64 64 Providing, Installation and Commissioning of Electric Composit Panel Board BI01010001010000000000000515BI0100001175
65 65 SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear . Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator) BI01010001010000000000000515BI0100001176 10 Sqm
66 66 Supplying and fixing of Aluminium / Copper bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending, cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. Electrolytic grade Aluminium bus bar BI01010001010000000000000515BI0100001177 5 Kg
67 67 SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push ( test ) to trip , including making connections with lugs & spreaders, etc. as required.With Thermal Magnetic release up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu BI01010001010000000000000515BI0100001178 6 Nos
68 68 Providing and fixing of three pole power Contactor confirming to IS 13947-4-1 IEC 60947-4-1. Standard coil voltage 110, 240, 415, 440V 50 Hz as per ISI marked/approved make L&T, GIC, ABB. Simenes Contactor AC3 rating (415) 12 Amp Motor output 3 phase 7.5 HP BI01010001010000000000000515BI0100001179 6 Nos
69 69 Contactor AC3 rating (415) 25 Amp Motor output 3 phase 15 HP BI01010001010000000000000515BI0100001180 6 Nos
70 70 P & F thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. Up to 14 Amp BI01010001010000000000000515BI0100001181 4 Nos
71 71 SF of selector switch of 10 A for voltmeter (4 position ) including making connection etc. as required . BI01010001010000000000000515BI0100001182 1 Nos
72 72 SF of CT linked selector switch of 10 A for Ampere meter (4 position ) including making connection etc. as required . BI01010001010000000000000515BI0100001183 5 Nos
73 73 SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required. Red/yellow/Green colour BI01010001010000000000000515BI0100001184 17 Nos
74 74 P & F push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. Luminous type Red , Yellow, Green, Amber BI01010001010000000000000515BI0100001185 8 Nos
75 75 Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. BI01010001010000000000000515BI0100001186 1 Set
76 76 S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 10 SWG copper. Wire BI01010001010000000000000515BI0100001187 5 Mtr.
77 77 SF of (0-500) V range Volt meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type BI01010001010000000000000515BI0100001188 1 Nos
78 78 SF of CT operated direct reading type Ampere meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A BI01010001010000000000000515BI0100001189 5 Nos
79 79 SF of Current Transformer , with all necessary support in existing panel including connection etc. as required. up to 150 / 5 Ratio , 5 VA , class 1 accuracy BI01010001010000000000000515BI0100001190 16 Nos
80 80 P&F of RCBO with overload, short-circuit and earth leakage protection ISI marked (IS12640)/ conforming to IEC 61009/1 complete in all respect including making connections, testing etc. as required. Two pole 100/300mA sensitivity 16 A rating BI01010001010000000000000515BI0100001191 4 Nos
81 81 P&F 240/415 V Residual current circuit breaker conforming to IS:12640:1988/ IEC 61008 on existing board/sheet including making connections, testing etc. as required Two pole 30 mA sensitivity 25 A rating BI01010001010000000000000515BI0100001192 4 Nos
82 82 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 1 x 1.5 sq.mm BI01010001010000000000000515BI0100001193 100 Mtr.
83 83 1 x 2.5 sq.mm BI01010001010000000000000515BI0100001194 25 Mtr.
84 84 1 x 4.0 sq.mm BI01010001010000000000000515BI0100001195 30 Mtr.
85 85 1 x 6.0 sq.mm BI01010001010000000000000515BI0100001196 30 Mtr.
86 86 Supply and laying PVC insulator submersible cable 3 core copper conductor of superior quality making connection etc in the following size as per related code, ISI Marked. Size 2.5 Sq. mm BI01010001010000000000000515BI0100001197 40 Mtr.
87 87 Size 4.0 Sq. mm BI01010001010000000000000515BI0100001198 50 Mtr.
88 88 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 2 x 2.5 sq.mm BI01010001010000000000000515BI0100001199 150 Nos
89 89 2 x 4.0 sq.mm BI01010001010000000000000515BI0100001200 50 Nos
90 90 2 x 6.0 sq.mm BI01010001010000000000000515BI0100001201 50 Nos
91 91 P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. Single pole MCB 0.5 A to 5 A rating BI01010001010000000000000515BI0100001202 7 Nos
92 92 6 A to 32 A rating BI01010001010000000000000515BI0100001203 4 Nos
93 93 Double pole MCB 6 A to 32 A rating BI01010001010000000000000515BI0100001204 2 Nos
94 94 Triple pole MCB 6 A to 32 A rating BI01010001010000000000000515BI0100001205 6 Nos
95 95 SITC of microprocessor based three phase sensing power factor correction relay having following sensing capacity secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, metering facility as required. 6 to 8 stage sensitivity up to 50 milli Amp BI01010001010000000000000515BI0100001206 1 Nos
96 96 P & F of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current , conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. up to 6 KVAR BI01010001010000000000000515BI0100001207 6 Nos
97 97 SITC of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR . including making connections with suitable capacity conductors/cables testing etc. as required. Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) BI01010001010000000000000515BI0100001208 25 kVAR
98 98 Providing and fixing of Timer as per ISI marked/approved make L&T, GIC, ABB. Simenes Electronic Timer 240/360 volt 415 Hz for 3 to 10sec./9 to 30sec./30 to 120sec BI01010001010000000000000515BI0100001209 4 Nos
99 99 Single phase Prevantor with automatic approved make L&T, Simenes, Vishnu. BI01010001010000000000000515BI0100001210 4 Nos
100 100 P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 70.0 Sq.mm 3.5 core BI01010001010000000000000515BI0100001211 50 Mtr.
101 101 Provision of SSF 1*10.00 Mtr. Dia Part- "A" - RCC Work BI01010001010000000000000515BI0100001212
102 102 Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 meter. All kinds of soil. BI01010001010000000000000515BI0100001213 48.1 Cum
103 103 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). BI01010001010000000000000515BI0100001214 3.6 Cum
104 104 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). BI01010001010000000000000515BI0100001215 13.2 Cum
105 105 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Cold twisted deformed bars (IS : 1786). BI01010001010000000000000515BI0100001216 1855 Kg
106 106 Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. \nM25 grade Nominal Mix / Design Mix BI01010001010000000000000515BI0100001217 31 Cum
107 107 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.\nM25 grade Nominal Mix / Design Mix BI01010001010000000000000515BI0100001218 8 Cum
108 108 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.\nM25 grade Nominal Mix / Design Mix BI01010001010000000000000515BI0100001219 2.1 Cum
109 109 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. BI01010001010000000000000515BI0100001220 85 Sqm
110 110 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters, buttresses plinth and string course. BI01010001010000000000000515BI0100001221 112.1 Sqm
111 111 Add extra for shuttering in circular work in plan abive dia 10 mtr. BI01010001010000000000000515BI0100001222 109 Sqm
112 112 Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. BI01010001010000000000000515BI0100001223 13 Sqm
113 113 Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in foundation and plinth with Cement mortar 1 : 4 (1 cement : 4 coarse sand) BI01010001010000000000000515BI0100001224 0.55 Cum
114 114 Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 12mm thick . BI01010001010000000000000515BI0100001225 9.55 Sqm
115 115 Providing, Laying, Jointing and Commissioning of pipeline UPVC Class-3 6 Kg. Per/Cm2 Pressure pipe with PVC Specials, C.I. Specials, C.I. Sluice Wall, C.I. Detachable Joints etc. complete in all respect as per detailed Specification. UPVC- 6 Kg per/cm2 class-3- 90 mm Ø BI01010001010000000000000515BI0100001226 125 RM
116 116 UPVC- 6 Kg per/cm2 class-3- 160 mm Ø BI01010001010000000000000515BI0100001227 50 RM
117 117 Excavating trenches of required width for pipe cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr.:\nPipes cables etc. not exceeding 80mm dia BI01010001010000000000000515BI0100001228 50 RM
118 118 Pipes cables, etc. exceeding 80mm dia but not exceeding 300mm dia. BI01010001010000000000000515BI0100001229 50 RM
119 119 Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. \nNote: Rates are exclusive of tail piece/ dismantling joints and earth work.100 mm BI01010001010000000000000515BI0100001230 2 Each
120 120 150mm dia PN-1.0 BI01010001010000000000000515BI0100001231 2 Each
121 121 Finishing walls with water proofing cement paint of required shade including all scaffolding. : New work (Two or more coats applied @ 3.84 kg/10 sqm). BI01010001010000000000000515BI0100001232 125 Sqm
122 122 Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. BI01010001010000000000000515BI0100001233 200 Kg
123 123 Part- :- "B" Filter Media BI01010001010000000000000515BI0100001234
124 124 Supply and charging of filter media (Gravel) as per department specification including screaming, washing with 5% HCL solution to make Gragel (Size 4 to 6mm, 8 to 12mm, 10 to 20mm - Hard Coarse Randhisar grit) free from silt, clay and other all imputries work to be executed as per scope of work fixed by the department at the time of tendering. a. Hard course Randhisar Grit ( 8 to 12 mm ) 8 cm thick BI01010001010000000000000515BI0100001235 4.8 Cum
125 125 b. Hard course Randhisar Grit ( 4 to 6 mm ) 7 cm thick BI01010001010000000000000515BI0100001236 4.5 Cum
126 126 c. Course sand ( 1.00 to 1.7 mm ) 10 cm thick BI01010001010000000000000515BI0100001237 6 Cum
127 127 Providing and Placing of new filter media as (i) Sand shall be hard and resistant quartz or quartzite and free of clay, fine particles, soft grains and dirt of any description. (ii) Effective size shall be 0.20 to 0.30 mm. (iii) Uniformity Coefficient not be more than 5.0 nor less than 3.0. (iv) Ignition loss should not exceed 0.70% by weight. (v) Soluble fraction in HCL acid shall not exceed 7.0% by weight, (vi) Silica content should not be less than 95% (vii) Specific Gravity shall be in the range between 2.55 to 2.65 (viii) Wearing loss shall not exceed 3.0%. and as per specifications given in IS: 8419 (Part-I). (ix) The sand should not contain more than 2% of calcium and manganese calculated as carbonate. Filter media (fine sand and coarse sand) should be processed through. Disindicator and dust seperator in automatic plant including screening of sand to desired. Specification and washing and cleaning of sand with water by aqua wash technology at quarry site. The sand shall not contain more than 5% acid soluble matter as determined by solubility test in Appendix B of IS: 8419 (Part-I) (Fine sand 0.2 to 0.3mm and coarse sand 1.0 to 1.7mm) Fine sand free from impurities & silt contents not more than 5 % ( 0.2 to 0.30 mm ) 100 cm thick BI01010001010000000000000515BI0100001238 63.9 Cum
128 128 Making 4mm dia hole in pipes of under drainage system of filters duly drilled. Carriage of pipe from stacks to filter site, making two per rows on pipe and points of making holes in Zig-Zag pattern in two hold raw. Making 4mm dia holes with drill machine @ 15cm BI01010001010000000000000515BI0100001239 1542 Each
129 129 Fixing of pipes for under drainge system including plugging pipes with CM 1:4 on one end and fixing other end in collecting channel with CM 1:4 with all Material etc.(Excl.cost of pipes) This job, also, includes Making 4mm dia holes in pipes @15 cm c/c in zig-zag patternhis and testing of under drainage system as per instruction of Engineer-in-charge. BI01010001010000000000000515BI0100001240 125 RM
130 130 Part - "C" Construction of Clear Water chamber, Filter media washing Platform BI01010001010000000000000515BI0100001241
131 131 Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 meter. All kinds of soil. BI01010001010000000000000515BI0100001242 20 Cum
132 132 P/L cement concrete complete including curing compaction etc. using stone aggregate 40 mm nominal size in found. & plinth using mix 1 : 5 : 10 excluding the cost of shuttering BI01010001010000000000000515BI0100001243 3.7 Cum
133 133 Brick masonry in foundation and plinth with bricks of class designation 75 in Cm 1 :4 BI01010001010000000000000515BI0100001244 15.5 Cum
134 134 Providing and fixing 1st quaility white Glazed Tiles of approved make and size (Somani. Johnson, etc,) 5 mm thick in walls, floor, steps, pillars etc. laid on a bed of neat cement surry finished with flash pointing in white cement (Execluding cost of cement plaster) BI01010001010000000000000515BI0100001245 40 Sqm.
135 135 Plaster on new surface on walls in cement sand mortar 1 : 4 including racking of joints etc. complete fine finished 12 mm thick BI01010001010000000000000515BI0100001246 100 Sqm
136 136 P/L cement concrete complete including curing compaction etc. using stone aggregate 20 mm nominal size in found. & plinth using mix 1 : 2 : 4 excluding the cost of shuttering BI01010001010000000000000515BI0100001247 2 Cum
137 137 Add extra if finished with a floating coat of neat cement including cement slurry etc. BI01010001010000000000000515BI0100001248 52.4 Sqm
138 138 Finishing with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade on new work { three or more coats } BI01010001010000000000000515BI0100001249 100 Sqm
139 139 P/F "V" nocth 90 degree made of brass stirrups as per deppt. Specifications BI01010001010000000000000515BI0100001250 2 Nos
140 140 Rejuvenation of SSF's BI01010001010000000000000515BI0100001251
141 141 Providing and Placing of new filter media as (i) Sand shall be hard and resistant quartz or quartzite and free of clay, fine particles, soft grains and dirt of any description. (ii) Effective size shall be 0.20 to 0.30 mm. (iii) Uniformity Coefficient not be more than 5.0 nor less than 3.0. (iv) Ignition loss should not exceed 0.70% by weight. (v) Soluble fraction in HCL acid shall not exceed 7.0% by weight, (vi) Silica content should not be less than 95% (vii) Specific Gravity shall be in the range between 2.55 to 2.65 (viii) Wearing loss shall not exceed 3.0%. and as per specifications given in IS: 8419 (Part-I). (ix) The sand should not contain more than 2% of calcium and manganese calculated as carbonate. Filter media (fine sand and coarse sand) should be processed through. Disindicator and dust seperator in automatic plant including screening of sand to desired. Specification and washing and cleaning of sand with water by aqua wash technology at quarry site. The sand shall not contain more than 5% acid soluble matter as determined by solubility test in Appendix B of IS: 8419 (Part-I) (Fine sand 0.2 to 0.3mm and coarse sand 1.0 to 1.7mm) BI01010001010000000000000515BI0100001252 212 P.Cum.
142 142 Removing & Re-fixing of pipes for under drainge system including cleaning of one end plugged pipes and fixing /embeded in CM 1:4 on one end and fixing other end in collecting channel with CM 1:4 with all Material etc.(Excl.cost of pipes) This job, also, includes Making 4mm dia holes if required in pipes @15 cm c/c in zig-zag pattern\n BI01010001010000000000000515BI0100001253 400 P. Meter
143 143 Labour charges for screening of old sand (received from filter beds) through the standard sieves, washing the sand with HCL acid of required concentration as directed by the Engineer- In- Charge, so as to remove all the mud and other deposits from sand grains and then clean with water till the sand is as neat and clean that it impart no colour to clean while washing. It also includes placing this washed filter media (sand) in filter beds in layer as instructed by the Engineer- In- Charge. (RGF, SSF) BI01010001010000000000000515BI0100001254 22 P.Cum
144 144 Labour charges for screening of old gravel (received from filter beds) through the standard diffrent sizes sieves for required sizes of gravel, washing the gravel with HCL acid of required concentration as directed by the Engineer- In- Charge, so as to remove all the mud and other deposits from gravel grains and then clean with water till the gravel is as neat and clean that it impart no colour to clean while washing. It also includes placing this washed gravel in filter beds in layer as instructed by the Engineer- In- Charge. (RGF, SSF) BI01010001010000000000000515BI0100001255 35 P.Cum
145 145 Removing of sluice valve in existing distribution pipe line and repair of pipe complete as required in existing system of pipe line:- 125 mm to 150mm BI01010001010000000000000515BI0100001256 4 Nos
146 146 Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. \nNote: Rates are exclusive of tail piece/ dismantling joints and earth work.150 mm BI01010001010000000000000515BI0100001257 5 Nos
147 147 ………..do……………80mm BI01010001010000000000000515BI0100001258 5 Nos
148 148 Providing of all size CI Plane Ended Special like Tees, Bends, Reducers, Enlargers, Plugs and Tail Pieces as per IS: 5531- 1988 (amended up to date- For CI Plane Ended Specials)requiring for laying, testing and commissioning of AC Pipe line as per Technical Specifications and as per direction of Engineer. BI01010001010000000000000515BI0100001259 150 Kg
149 149 Demolishing brick work including stacking of serviceable material and disposal of U/S material within 50m lead (B/W in cement mortar) BI01010001010000000000000515BI0100001260 10 Cum.
150 150 Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in foundation and plinth with Cement mortar 1 : 4 (1 cement : 4 coarse sand) BI01010001010000000000000515BI0100001261 10 Cum.
151 151 Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finished 12mm thick. One coat BI01010001010000000000000515BI0100001262 80 Sqm.
152 152 Providing and laying in position specified grade of reinforced cement concrete including curing compaction finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. All work up to plinth level : 1:1:2 (1-Cement:1-Coarse sand:2-graded stone aggregate 20 mm nominal size) M- 25. BI01010001010000000000000515BI0100001263 7 Cum.
153 153 Providing and fixing Ist quality standard White/Ivory Glazed Tiles ISI marked (IS:13753) of size 300mmx200mm (or any other)in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster).Category-I Kajaria, Jhonson, Orient, Somani make etc. BI01010001010000000000000515BI0100001264 50 Sqm
154 154 Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Three or more coats). BI01010001010000000000000515BI0100001265 250 Sqm
155 155 Construction of PTU BI01010001010000000000000515BI0100001266
156 156 Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms , lift upto 1.50mtr. Including taking out the excavated soil and depositing and refilling the jhiri with watering and rammingand disposal of surplus soil as directed within a lead of 50 mtr. in Hard soil BI01010001010000000000000515BI0100001267 45 Cum
157 157 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix \n1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). BI01010001010000000000000515BI0100001268 10 Cum
158 158 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.\nM20 grade Nominal Mix / Design Mix BI01010001010000000000000515BI0100001269 11 Cum
159 159 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.\nM20 grade Nominal Mix / Design Mix BI01010001010000000000000515BI0100001270 32 Cum
160 160 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) BI01010001010000000000000515BI0100001271 2850 Kg
161 161 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. BI01010001010000000000000515BI0100001272 25 Sqm
162 162 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Walls (any thickness) including attached pilasters, buttresses plinth and string course. BI01010001010000000000000515BI0100001273 300 Sqm
163 163 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. BI01010001010000000000000515BI0100001274 70 Sqm
164 164 Supply & fixing of stainless steel pipe railing, railing height, 90 cm. with 40 mm dia stainless steel pipe with 18 gauge with drop (vertical post) at 90 cm. C/C and intermidiate horizontal pipe with suitable height of same size and gauge with coupling, grinding and polishing & fix of master pieces as per required point as per approved design of Engineer incharge. BI01010001010000000000000515BI0100001275 45 RM
165 165 Structural steel work in single section fixed without connecting plate including cutting,hoisting,fixing in position and applying a coat of appd . Primer copmlete above plinth level BI01010001010000000000000515BI0100001276 150 Kg
166 166 Providing of all size CI Plane Ended Special like Tees, Bends, Reducers, Enlargers, Plugs and Tail Pieces as per IS: 5531- 1988 (amended up to date- For CI Plane Ended Specials)requiring for laying, testing and commissioning of AC Pipe line as per Technical Specifications and as per direction of Engineer. BI01010001010000000000000515BI0100001277 120 Kg
167 167 Providing of all size CI Flanged Special like Tees, Bends, Reducers and Enlargers as per IS: 1538-1993 (amended up to date) requiring for laying, testing and commissioning of AC Pipe line as per Technical Specifications and as per direction of Engineer. BI01010001010000000000000515BI0100001278 100 Kg
168 168 Providing, Fabrication of Mild Steel Plane Ended/Flanged Specials like Tees, Bends, Reducers, Enlargers, Plugs, Tail Pieces and Blank Flange made from MS pipes, MS sheet strip and MS Sheet of required sizes by welding, cutting and treading as per site conditions and as directed by the Engineer- In- Charge complete in all respect. BI01010001010000000000000515BI0100001279 50 Kg
169 169 Providing, Laying, Jointing and Testing of Ductile Iron (DI Spun) Pipes with socket and spigot end & tyton joint suitable for push-on-joint (Rubber gasket D jointing) with inside cement mortar lining confirming to IS 8329: 2000 (amended up to date) of Class- K-7 in as per in assorted length with specials, valves (Excluding DI/ MS Specials and Valves of any type) etc. this including the pipes, joints/ coupling etc. and other material arranged by the Contractor himself own cost carting to site. Dismantling of road surface, excavation & earth work of trenches & as per detailed specification & drawing, then jointing with rubber gaskets (DI Pipes, Rubber Gaskets and Soap Solution shall be and other material shall be arranged by the Contractor himself own cost). Cutting of pipes including testing of system, clearing of site complete job for: (The Rates are Exclusive of Earth Work and WBM/ Chap/ Cement Concrete/ Bituminious Road cutting, DI/ MS Specials and Valves of any type)- Nominal Dia. 150 mm BI01010001010000000000000515BI0100001280 20 RM
170 170 Providing, Laying, Jointing, Commissioning and Testing of uPVC Pipes confirming to IS 4985: 2000 (amended up to date) of Class- 3 in assorted length with uPVC specials. This includes supply of pipes, jointing material, uPVC specials and any other material required for laying of pipes including carting to site and laying of pipes in trenches then jointing with Jointing material/ Rubber Rings. This includes uPVC Special like tees, bends, reducer, enlarger, end plug cutting of pipes and making of joints etc. and testing of system, cleaning of site complete job. (Rates are Exclusive of Earth Work and WBM/ Chap/ Cement Concrete/ Bituminious Road cutting, CI Sluice Valve/ CI Specials for interconnection with other pipes, if required and including interconnection with existing pipe line, if required)- Pipes Nominal Dia.160 MM BI01010001010000000000000515BI0100001281 50 RM
171 171 -- do -- 110 mm Dia BI01010001010000000000000515BI0100001282 45 RM
172 172 Excavating trenches of required width as per size of pipes, including excavation for sockets and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil and then returning the soil as required in layers not exceeding 20 Cm in depth including consolidating each deposited layer by ramming and watering etc. and disposing of surplus excavated soil as directed within a lead of 50Mtr. BI01010001010000000000000515BI0100001283 40 Cum
173 173 Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. \nNote: Rates are exclusive of tail piece/ dismantling joints and earth work.150 mm BI01010001010000000000000515BI0100001284 6 Each
174 174 Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. \nNote: Rates are exclusive of tail piece/ dismantling joints and earth work.150 mm BI01010001010000000000000515BI0100001285 2 Each
175 175 Providing and fixing Ist quality standard White/Ivory Glazed Tiles ISI marked (IS:13753) of size 300mmx200mm (or any other)in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster).Category-I Kajaria, Jhonson, Orient, Somani make etc. BI01010001010000000000000515BI0100001286 20 Sqm
176 176 P&F rigid PVC Pipe (IS:4985 mark) approved quality /make including joining ,15mm dia (including fittings)PPR pipes as per specifications BI01010001010000000000000515BI0100001287 80 RM
177 177 P & F Full-way valve (IS:778 Mark) or wheel valve of approved make :Gun- metal 15 mm nominal bore. BI01010001010000000000000515BI0100001288 2 Each
178 178 P & F Gun-metal Non-return Valve or Check Valve(IS:Make) of approved make, superior quality ::Gun metal 15 mm nominal bore. BI01010001010000000000000515BI0100001289 1 Each
179 179 Brick masonry in foundation and plinth with bricks of class designation 75 in CM 1 : 4 BI01010001010000000000000515BI0100001290 5.5 Cum
180 180 Plaster on new surface on walls in cement sand mortar 1 : 4 including racking of joints etc. complete fine finished 12 mm thick BI01010001010000000000000515BI0100001291 80 Sqm
181 181 Painting with weather coat paint (Asin paint/I.C.I./Berger or eq. ISI make paint) two or more coat to give an even shade on new work. BI01010001010000000000000515BI0100001292 30 Sqm
182 182 Finishing wall with water proofing cement paint of approval brand and manufacture and or required shade to give an even shade including all scaffolding on (new work 2 or more coats). BI01010001010000000000000515BI0100001293 100 Sqm
183 183 Supply & Installation of Hydrofoil blade turbine type flocculator for upto 1 MLD flow, MOC SS 304, with impeller min 800mm dia, shaft 50mm, min 2.5m Long. Drive unit Geared Motor, 70:1 1440 rpm motor, IP55 class F insulation. Installation Platform min 4 m long, min 900 mm wide, size/design to suit site operational requirements (RCC or epoxy painted ISMC 125, 5mm chequered Plate, SS anchor bolts,reduction, min 180 watt, MS Galv fixing nuts bolts) BI01010001010000000000000515BI0100001294 1 Job
184 184 Supply and fixing of Oil / Air break Starter panel made out of sheet steel powder coated enclosure comprising of over load protection relay, short circuit & single phasing protection, ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. complete in all respect suitable for following rating motors.3.0 HP to 10.0 HP ( DOL ) BI01010001010000000000000515BI0100001295 1 Nos
185 185 Supply and laying PVC insulator submersible cable 3 core copper conductor of superior quality making connection etc in the following size as per related code, ISI Marked.2.50 sqmm BI01010001010000000000000515BI0100001296 30 RM
186 186 Provision for Construction of Pump House BI01010001010000000000000515BI0100001297
187 187 Dismantling stone slab roofing over wooden karries and battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 meter lead : BI01010001010000000000000515BI0100001298 18 Sqm
188 188 Demolishing brick work including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.In Cement mortar. BI01010001010000000000000515BI0100001299 25 P.Cum.
189 189 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 meters (stacks of cleaned bricks ahall be measured):From brick work in Cement mortar. BI01010001010000000000000515BI0100001300 5500 Nos.
190 190 Dismantling cement plaster including stacking of serviceable material and disposal of unserviceable material with in 50 meter lead. BI01010001010000000000000515BI0100001301 90 P.Sqm
191 191 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. \nAll kinds of soils BI01010001010000000000000515BI0100001302 45 Cum
192 192 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). BI01010001010000000000000515BI0100001303 6.5 Cum
193 193 Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in foundation and plinth with Cement mortar 1 : 6 (1 cement : 6 coarse sand) BI01010001010000000000000515BI0100001304 22 Cum
194 194 Brick masonary in super structure with brick of class designation 75 in cement mortar 1:6 upto 4.5M height above plinth level. BI01010001010000000000000515BI0100001305 30 Cum
195 195 Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. \nM20 grade Nominal Mix / Design Mix Add extra for providing richer mixes respectively at all floor levels Providing M-25 grade concrete by using min 410 kg of cement per cum instead of M-20 grade design mix. BI01010001010000000000000515BI0100001306 5 Cum
196 196 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.\nM20 grade Nominal Mix / Design Mix Add extra for providing richer mixes respectively at all floor levels Providing M-25 grade concrete by using min 410 kg of cement per cum instead of M-20 grade design mix. BI01010001010000000000000515BI0100001307 8.5 Cum
197 197 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) BI01010001010000000000000515BI0100001308 900 Kg
198 198 Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of formwork for superstructure up to 4.5 mtr above plinth, for: Walls (any thickness) including attached pilasters, buttresses, plinth and string course. BI01010001010000000000000515BI0100001309 60 Sqm
199 199 Filling local sand in trenches, plinth,sides of foundtion, under floor etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by remming and watering including all leads and lifts. BI01010001010000000000000515BI0100001310 100 Cum
200 200 Providing and laying tiles of class designation 100 over mumty roots, grouted with cement mortar 1:3 mix with 2% crude oil by weight of cement over 12mm thick layer of cement mortar 1:3 and finished neat. BI01010001010000000000000515BI0100001311 40 Sqm
201 201 Polished Blue Kota Stone stab in steps, walks, pillars having fine machine cut edges laid on 12mm (Av.) thick cement mortar 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rebbing and polishing complete : 20 mm thick slab area upto 2001 to 5000 Sq.Cm. BI01010001010000000000000515BI0100001312 50 Sqm
202 202 Providing and appling wall putty (JK/Birla or equivalent)or POP Filling complete to achieve fine finish one or more coat BI01010001010000000000000515BI0100001313 200 Sqm
203 203 Cement plaster on new surface on walls with cement bajri mortar 1:4 including finishing of corners the complete 12mm thick in one coat. BI01010001010000000000000515BI0100001314 250 Sqm
204 204 Finishing wall with water proffing cement paint of approved brand and manufacture and of required shade to give an even shade including all scaffolding new work 3 or more coals. BI01010001010000000000000515BI0100001315 250 Sqm
205 205 P & F Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall : PVC with PVC bend as per IS : 7231 BI01010001010000000000000515BI0100001316 2 Each
206 206 P & F G.I. Pipes (Internal work) with G.I. fittings (IS:1239 Mark) including trenching & refilling earth etc. 15 mm dia nominal bore. BI01010001010000000000000515BI0100001317 12 Mtr.
207 207 P & F Bib Cock (IS:8931 Mark) Superior quality of approved make : Brass 400 gm. 15 mm nominal bore. BI01010001010000000000000515BI0100001318 2 Each
208 208 P & F on wall face A.C. pipes (IS:1626 part – I mark) of approved make with wooden plugs and M.S. clamps, jointing with spun yarn soaked in bitumen and C.M. 1:2 complete including making good the wall : 100mm dia BI01010001010000000000000515BI0100001319 6 Mtr.
209 209 Wiring for circuit / sub main wiring with 2x1.5sqmm PVC insulated PVC sheathed copper conductor cable ( IS:694) of category-II and approved make along with earthing with aluminium bar conductor 2.24 mm dia as required on T/W batten of assorted size with warnishing and two coats of anti termite paint on batten including cost of clips screws etc. Complete. BI01010001010000000000000515BI0100001320 20 Mtr.
210 210 Writing for 3 Pin 15 Amp power plug point with 4 Sqmm insulated PVC copper conductor of approved make along with earthing with 2.24 mm dia size alumimium bar conductor as required on TW batten, warnishing and two coats of antitermite paind including cost of 2 pin 15 AMP socket and switch, TW switch boars, clips, screws etc, complete short point 3M. BI01010001010000000000000515BI0100001321 2 Each
211 211 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, round tiles,18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & falce ceiling point, 6 A switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. Short point (up to 3 M) BI01010001010000000000000515BI0100001322 5 Each
212 212 Medium point (up to 6 M) BI01010001010000000000000515BI0100001323 11 Each
213 213 long point (up to 10 M) BI01010001010000000000000515BI0100001324 5 Each
214 214 Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & falce ceiling point, 6 A switch, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. : On board BI01010001010000000000000515BI0100001325 3 Per Point
215 215 S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall and making good the same as required. : 25 mm BI01010001010000000000000515BI0100001326 25 R. Mtr.
216 216 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 2 x 1.5 sq.mm BI01010001010000000000000515BI0100001327 5 Mtr
217 217 2 x 2.5 sq.mm BI01010001010000000000000515BI0100001328 5 Mtr
218 218 Supplying and fixing of power plug point accessories on 18 SWG metal box of size 175 x 100 x 60 mm. on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. Switch and socket outlet , making connection , testing , etc. as required. BI01010001010000000000000515BI0100001329 2 Each
219 219 P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required. : 6 A to 32 A rating BI01010001010000000000000515BI0100001330 3 Each
220 220 P&F 240/415 V isolator conforming to IS:13947-III/ IEC 60947-3 on existing board / sheet including making connections with lugs , testing etc. as required. : 30 A / 40 A rating BI01010001010000000000000515BI0100001331 1 Each
221 221 P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with 100 A copper bus bar, shorting link , neutral link, earth link and din bar, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required. : 4 Way BI01010001010000000000000515BI0100001332 1 Each
222 222 P & F ISI marked (IS :3854) 6 amp. flush type switch including cutting hole in tile and making connection testing etc. as required. BI01010001010000000000000515BI0100001333 10 Each
223 223 P & F ISI marked (IS :3854) 16 amp. flush type switch including cutting hole in tile and making connection testing etc. as required. BI01010001010000000000000515BI0100001334 5 Each
224 224 P & F ISI marked (IS :1293) 3 pin 6 amp. flush type socket including cutting hole in tile and making connection testing etc. as required. BI01010001010000000000000515BI0100001335 3 Each
225 225 P & F ISI marked (IS :1293) 3/6 pin 16 amp flush type socket including cutting hole in tile and making connection testing etc. as required. BI01010001010000000000000515BI0100001336 3 Each
226 226 P & F ISI marked 6 amp bakelite batten/angle holder including making connection testing etc. as required. BI01010001010000000000000515BI0100001337 4 Each
227 227 P & F ISI marked flush type 120/280 watt rotary step fan regulator including making connection testing etc. as required.\n BI01010001010000000000000515BI0100001338 2 Each
228 228 Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. BI01010001010000000000000515BI0100001339 1 Each
229 229 S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. : 10 SWG copper. Wire BI01010001010000000000000515BI0100001340 10 Mtr
230 230 P & F 1.6 mm thick M.S. Recessed fan box, hexagonal/ round of size 100 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . BI01010001010000000000000515BI0100001341 2 Each
231 231 P & F Star rated double ball bearing capacitor start, aluminium body & blade ceiling fan with down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 1200 mm Sweep 5 Star rated BI01010001010000000000000515BI0100001342 4 Each
232 232 P & F IS:371 marked 6 amp surface type ceiling rose including making connection testing etc. as required. BI01010001010000000000000515BI0100001343 6 Each
233 233 P & F industrial fluorescent tube fitting with reflector fabricated from CRCA sheet and finished with powder coating / vitreous enamelled complete with accessories like (OCCB, starter, starter seat)/ EB, condensor,rotor holder, terminal block duly prewired with copper conductor including making connection, testing etc. as required.( without tube) : 1 X 36 Watts with OCCB BI01010001010000000000000515BI0100001344 4 Each
234 234 P & F Fluorscent tube rod in existing fixtures as required : 36/40 Watts BI01010001010000000000000515BI0100001345 4 Each
235 235 Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. : 4.0 sq.mm BI01010001010000000000000515BI0100001346 25 Mtr.
236 236 P & F IP-54 protected street light luminaire on existing bracket suitable for HPSV lamp, made out from powder coated single piece die cast aluminium housing, electrochemically brightened and anodized POT optics aluminium reflector, UV stabilised acrylic bowl cover and accessories like copper ballast, electronic ignitor, capacitor, holder prewired up to terminal block etc. as required including making connection testing etc. as required (without lamp) : 1 X 150 Watt BI01010001010000000000000515BI0100001347 2 Each
237 237 P & F High pressure sodium vapour/ High pressure mercury vapour/ Metal halide/ Halogen lamp as required. : 150 Watt BI01010001010000000000000515BI0100001348 2 Each
238 238 Providing & fixing anodizing alumium work (Anodizing to be got done from approved Anodizer) for doors, windows, ventilators and partition with extruded built up standard tubular and other sections of approved make confirming to IS : 733 and IS : 1285 anodised transparent 81 dyed to required shade according to IS : 1868 (Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gas at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required inlcuding cleat angle Aluminum snap beading for glazing/paneling, C.P. Brass/ Stainless Steel screws, Al. Tower bolt & Al. handle & Al. Aldrop etc. all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and peneling to be paid for separately). For Fixed portion BI01010001010000000000000515BI0100001349 50 Kg
239 239 For shutters of doors, windows & ventilators incl. providing and fixing hinges/ rollers etc. and making provision for fixing of fittings wherever reqd. (lockes shall be paid for separately). Note : Add 10% extra over item No. 16.1 for work done in curved/ circular shape. BI01010001010000000000000515BI0100001350 50 Kg
240 240 Providing and Fixing 12mm thick prelaminated three layer medium density (exterior grade) particle bonded formaldehyde synthetic resin of approved brand and manufacture in paneling fixed in aluminium doors, windows/ stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Pre-laminated particle board with decorative lamination on both side BI01010001010000000000000515BI0100001351 5 Sqm
241 241 Providing and fixing glazing in aluminium door, window, vintilator shutters and partitions etc. with PVS/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge (Cost. of aluminium snap beading shall be paid in basic item.) with glass panes of 5.0mm thickness (weight not less than 13.75 Kg/Sqm) as per IS : 2835 BI01010001010000000000000515BI0100001352 13.5 Sqm
242 242 P&F double action hydraulic floor spring of approved brand and manufacture to aluminium door shutter confirming to IS : 6315 incl. costof cutting floors as reqd. embedding in floor and cover plate etc. complte as per direction of Engineer in charge. BI01010001010000000000000515BI0100001353 2 no
243 243 P&F expanded grill made of anodised aluminium as per desing and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminium window/ vent with reqd. screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. BI01010001010000000000000515BI0100001354 15 Sqm
244 244 Providing and fixing brass lock without handle for aluminium door, or approved quality, make & design as directed by Engineer inc harge BI01010001010000000000000515BI0100001355 2 Each
245 245 P/Laying P.V.C. insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I of Group2 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 35.0 Sq.mm 3.5 Core BI01010001010000000000000515BI0100001356 40 Mtr.
246 246 P&F PVC Storage Tank ( IS: 12701 marked indicating the BIS License No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design. 300 Litres capacity BI01010001010000000000000515BI0100001357 1 Nos
247 247 Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). BI01010001010000000000000515BI0100001358 6 Sqm
248 248 Deduction for Old Bricks BI01010001010000000000000515BI0100001359 5500 Each
249 249 Providing, laying jointing of distribution pipe line BI01010001010000000000000515BI0100001360
250 250 Providing , supplying, lowering and laying instandard lengths HDPE PE-80 PN-6 pipes conforming to IS 4984 :1995 with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ Compression fitting joint or flanged joint and specials jointing pipes by butt fusion welding method, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/unloading charges, stacking the same in closed shade duly protecting from sunrays and rains, including cost of labour and material, specials tee, bends etc., satisfactory hydraulic testing etc., complete as per technical speciafications and directions of Engineer-In-Charge (excluding earthwork) PE-80/PN-6, for internal village distribution network\n75 mm BI01010001010000000000000515BI0100001361 150 RM
251 251 Providing , supplying, lowering and laying instandard lengths HDPE PE-80 PN-6 pipes conforming to IS 4984 :1995 with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ Compression fitting joint or flanged joint and specials jointing pipes by butt fusion welding method, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/unloading charges, stacking the same in closed shade duly protecting from sunrays and rains, including cost of labour and material, specials tee, bends etc., satisfactory hydraulic testing etc., complete as per technical speciafications and directions of Engineer-In-Charge (excluding earthwork) PE-80/PN-6, for internal village distribution network\n90 mm BI01010001010000000000000515BI0100001362 2350 RM
252 252 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. BI01010001010000000000000515BI0100001363 2500 mtr
253 253 Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. \nNote: Rates are exclusive of tail piece/ dismantling joints and earth work.100 mm dia BI01010001010000000000000515BI0100001364 1 Each
254 254 Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. \nNote: Rates are exclusive of tail piece/ dismantling joints and earth work.80 mm dia BI01010001010000000000000515BI0100001365 3 Each
255 255 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In mud mortar. BI01010001010000000000000515BI0100001366 51.75 cum
256 256 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix. BI01010001010000000000000515BI0100001367 45 Cum
257 257 Dry brick on edge flooring in required pattern with bricks of class designation 75 on a bed of 12mm mud mortar including filling joints with river sand complete. (PWD BSR 2019) BI01010001010000000000000515BI0100001368 51.75 sqm
258 258 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M15 grade Nominal Mix \n1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).9) BI01010001010000000000000515BI0100001369 45 Cum
259 259 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. BI01010001010000000000000515BI0100001370 125 Kg
260 260 Providing of all size CI Flanged Special like Tees, Bends, Reducers and Enlargers as per IS: 1538-1993 (amended up to date) requiring for laying, testing and commissioning of AC Pipe line as per Technical Specifications and as per direction of Engineer. (PHED Circle SGNR BSR 2015) BI01010001010000000000000515BI0100001371 110 Kg
261 261 JJM including FHTC BI01010001010000000000000515BI0100001372
262 262 Providing service connection as per technical specifications & standard drawing as per relevant IS Code (amended up to date) from all kind of water mains up to consumer meter/premises (Complete job). This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil including demolishing of Cement Concrete,WBM, Black top etc. of all thickness; cutting of CC road/jhiriby using a concrete cutter machine; depositing and refilling of pit &jhiri with watering & ramming/compacting in layers and disposal of surplus excavated soil as directed with in a lead of 50 meter; providing& fixing of all fitting duly approved in accordance with ISO/DTR 9080 as per specification for potable water including approved make of MS clamp with saddle piece gunmetal ferrule (ISI make), gunmetal NRV (ISI Make), valve (IS:778) and specials with MDPE pipe PE-80 PN 16 as per ISO 4427, with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connectioncomplete in all respect including labour charges. The service line should be laid at least 45 cm below ground level, except in cases of concrete / bituminous roads where minimum depth shall be 20 cm. For detailed specifications of MDPE pipes, please refer section “Technical Specifications” in Volume I of bid document. General specifications of MDPE pipes shall be as under: \n• The raw material shall be virgin PE 80 Blue compound and comply with the requirements of ISO/Directive of Testing Material: 9080 with minimum required strength of 8kg/sq.cm.\n• The raw material shall be of Food grade quality\n• Pressure rating shall be 16 Bar\n• The pipes shall bear ISO arking\nAverage length upto 5.00 mtr of 20 mm MDPE pipe. (CE(SP) Order no. 4232-40 Dtd. 04.03.2020) BI01010001010000000000000515BI0100001373 284 Nos
263 263 Data entry of existing FHTCs in rural area under JJM on website ejalshakti.gov.in; work includes visiting the village for collecting basic data consumers like i.e. Aadhar no./ration card/voter ID/BPL card/ PAN card/driving licence/passport/Antyodaya card/mobile no. etc. and entering the details on the above website. The cost also includes computer and operator BI01010001010000000000000515BI0100001374 284 FHTC
264 264 Rejuvenation of CWR BI01010001010000000000000515BI0100001375
265 265 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. \nAll kinds of soils BI01010001010000000000000515BI0100001376 10 Cum
266 266 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix \n1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) BI01010001010000000000000515BI0100001377 2.5 Cum
267 267 Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. \nProviding M-25 grade concrete by using min 410 kg of cement per cum instead of M-20 grade design mix. BI01010001010000000000000515BI0100001378 2.7 Cum
268 268 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.\nProviding M-25 grade concrete by using min 410 kg of cement per cum instead of M-20 grade design mix. BI01010001010000000000000515BI0100001379 0.8 Cum
269 269 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001380 5 Cum
270 270 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Arches, arch ribs, domes, vaults, shells, folded plate, chimneys, shafts , roofs having slope more than 15º ,vertical and horizontal fins individually or forming box louvers, facias and eaves boards\nM20 grade Nominal Mix / Design Mix BI01010001010000000000000515BI0100001381 2.7 Cum
271 271 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) BI01010001010000000000000515BI0100001382 350 Kg
272 272 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. BI01010001010000000000000515BI0100001383 8 Sqm
273 273 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Walls (any thickness) including attached pilasters, buttresses plinth and string course. BI01010001010000000000000515BI0100001384 36 Sqm
274 274 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Arches, domes, vaults etc. up to 6 Mtr span. BI01010001010000000000000515BI0100001385 27 Sqm
275 275 Add extra for shuttering in circular work (in respective centering and shuttering items) BI01010001010000000000000515BI0100001386 36 Sqm
276 276 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001387 195 Kg.
277 277 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.46 mm dia wire and 1.63 mm\naperture on both sides BI01010001010000000000000515BI0100001388 0.85 Sqm
278 278 Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.\nWelded mesh 25 mmx 25 mm x 2.1 mm BI01010001010000000000000515BI0100001389 0.85 Sqm
279 279 Finishing walls with water proofing cement paint of required shade including all scaffolding. : New work (Two or more coats applied @ 3.84 kg/10 sqm). BI01010001010000000000000515BI0100001390 38 Sqm
280 280 Operation and Maintanance BI01010001010000000000000515BI0100001391
281 281 Operation and maintenance of water supply schemes. This includes operation of pump sets, repairing of pipe line, patrolling of raw water conveyance system to fill raw water storage tanks, O&M of filter plant to maintain water supply, periodical cleaning o Head works and allied units, (Repairing of pump sets panels etc will be carried out by department and material for maintenance of pipe line will be provided by department ) when 4 persons are required for O&M of scheme. BI01010001010000000000000515BI0100001392 57 Per Month
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail