Bids For The Retrofitting Works Of 28 Villages Of Bassi Tehsil Under Bassi-Bisalpur Water Supply Project To Carry Out Works Of Providing Functional Household Tap Connections Under Jal Jeevan Mission Jjm

Issued by Government Departments · BASSI, Rajasthan
Tender Value
24.95 Crore
Estimated cost
Bid Submission
29 Jul 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
BASSI → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Bids For The Retrofitting Works Of 28 Villages Of Bassi Tehsil Under Bassi-Bisalpur Water Supply Project To Carry Out Works Of Providing Functional Household Tap Connections Under Jal Jeevan Mission Jjm

BOQ

Name of Work : Bids for the Retrofitting Works of 28 Villages of Bassi Tehsil under Bassi-Bisalpur water supply project to carry out works of providing Functional household Tap connections under Jal Jeevan Mission (JJM)
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Provision of Construction of 200 mm Dia Tube Well and installation of Pumping Machinery.(15 No.)BI01010001010000000000000515BI0100001113
21.01Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications, with gravel as per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water.BI01010001010000000000000515BI01000011141050Rmt.
31.02Construction of tube well after completion of drilling by rotary method & upto 150 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.BI01010001010000000000000515BI01000011151650Rmt.
41.03Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as per amended up to date.BI01010001010000000000000515BI010000111615Each
51.04Supplying & Packing P-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-I) 1991 with latest amendment.BI01010001010000000000000515BI010000111747.7Cum
61.05Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)BI01010001010000000000000515BI01000011181065Rmt.
71.06Labour charges for making slots on blank pipes made of ERW MS black pipe of following sizes, the slotting should be as per IS:8110-2000 or as amended up to date. 200 mm diaBI01010001010000000000000515BI0100001119540RM
81.07Supply and fixing MS clamp set o 50 X 6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pumpsetBI01010001010000000000000515BI010000112015Each
91.08Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.BI01010001010000000000000515BI010000112115Nos.
101.09Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 7.5 KW (10 HP) & head above 120 mtr.(1W+1S)BI01010001010000000000000515BI0100001122225KW
111.1Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes.BI01010001010000000000000515BI0100001123
121.11a) 80 mmBI01010001010000000000000515BI010000112415Nos.
131.12Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.BI01010001010000000000000515BI0100001125
141.13a) 80 mmBI01010001010000000000000515BI010000112615Nos.
151.14Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for 440 Volt AC Supply.BI01010001010000000000000515BI0100001127
161.15Above 5 HP and up to 10 HPBI01010001010000000000000515BI010000112815Nos.
171.16Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.BI01010001010000000000000515BI0100001129
181.1716 sq mm size, 4 coreBI01010001010000000000000515BI0100001130450RM
191.18SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. \nNote: Rates are exclusive of tail piece / dismantling joints and earth work.BI01010001010000000000000515BI0100001131
201.19EFM 50 mmBI01010001010000000000000515BI010000113215Each
211.2Supplying & installing 100mm dia mtr sealed diaphragm bourdon type pressure gauge of range of 0 to 10 Kg including all jointing materials as per specification with safety coverBI01010001010000000000000515BI010000113315Nos.
221.21Providing & Lowering in tubewell ISI marked GI Pipe “B\" (medium) class as per IS:1239 part I 2004 or amended up to date, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.BI01010001010000000000000515BI0100001134
231.22a. 50mm dia.BI01010001010000000000000515BI01000011352100RM
241.23Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.BI01010001010000000000000515BI010000113615Sets
251.24Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge.BI01010001010000000000000515BI010000113715Nos.
261.25Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.BI01010001010000000000000515BI0100001138
271.26a 4.0Sq.mm 3 coreBI01010001010000000000000515BI01000011394200RM
281.27Providing & laying GI Pipe “A” (Light) class as per IS: 1239 pat 1: 2004 or amended upto date for casing pipe for submersible cable external work 40 mm dia complete in all respect.BI01010001010000000000000515BI010000114090RM
291.28Provision of pressure censor,RTU panel with GSM data loger,compatable date transferring data of amphere,voltage,ON/OFF,pressure,Flow tomaster controll centre.Transferring data to already established SCADA centre at Bassi IPS.BI01010001010000000000000515BI010000114115Each
302SITC of IEC, TUV certified, MNRE approved Solar Panels suitable for Rooftop as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and structure, showing arrangement of panel on available space, installation of PV module structure on shed / roof as per drawings including super structure wherever necessary as per drawin. Mounting structure suitably design to withstand wind velocity upto 150km/hr. Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5years warranty. All cabling up to panel and metre, earthing etc. required accessiories and taxes are inclusive. (At Bassi IPS)BI01010001010000000000000515BI01000011425000Watt
313Provision for storage ESR and CWR .BI01010001010000000000000515BI0100001143
323.01Construction of RCC INTZE type Over Head Service Reservoir of following capacity and staging consisting of excavation in all types of strata, RCC work, cement plaster with water proofing compound to the inner face of the container including refilling disposing off the surplus stuff, plinth protection , all labour and material charges including providing and fixing of accessories such as ladder , manhole frame and covers, water level indicator (float type), ventilator with SS scren, lightening arrestor, float valve, puddle collar, G.I. pipe railing around walk way and top dome, providing RCC staircase from 4.5 mtr height of ground level to top level, chambers for all valves, providing and applying three coats of cement paint to the external surfaces of container, food grade epoxy paint to internal surface and giving satisfactory hydraulic test and water tightness test as per I.S. code, etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job includes painting the name of the scheme and other details on the reservoir, providing alluminium portable ladder suitable to reach at height of 4.5 Mtr and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work .BI01010001010000000000000515BI0100001144
333.02AT BASSI IPSBI01010001010000000000000515BI0100001145
343.03Dyorha Chor ---- 200 KL ; 20 MtrBI01010001010000000000000515BI0100001146200000Litre
353.04Ghata ---- 200 KL ; 20 MtrBI01010001010000000000000515BI0100001147200000Litre
363.05Mansar Kheri ---- 200 KL ; 20 MtrBI01010001010000000000000515BI0100001148200000Litre
373.06Mangarh Khokhawala ---- 200 KL ; 20 MtrBI01010001010000000000000515BI0100001149200000Litre
383.07Providing and flxing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended upto date), as vertical pipes for RCC Reservoirs including specials required such as duckfoot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all resepect upto and from valve chamber as per direction of EIC, Technical Specification and Scope of work.BI01010001010000000000000515BI0100001150
393.08AT BASSI IPSBI01010001010000000000000515BI0100001151
403.09Dyorha Chor,Mansar Kheri and Mangarh Khokhawala ---- 200 KL ; 20 Mtr(Each)BI01010001010000000000000515BI0100001152
413.1Wash out pipe 100 mm (For Four ESR)BI01010001010000000000000515BI0100001153100m
423.11Inlet pipe 100 mm (For Dyorha Chor,Mansar Kheri and Mangarh Khokhawala ESR)BI01010001010000000000000515BI010000115490m
433.12Outlet pipe 150 mm (For Dyorha Chor,Mansar Kheri and Mangarh Khokhawala ESR)BI01010001010000000000000515BI010000115575m
443.13Overflow pipe 150 mm(For Dyorha Chor,Mansar Kheri and Mangarh Khokhawala ESR)BI01010001010000000000000515BI010000115690m
453.14Ghata ---- 200 KL ; 20 MtrBI01010001010000000000000515BI0100001157
463.15Inlet pipe 150 mmBI01010001010000000000000515BI010000115830m
473.16Outlet pipe 200 mmBI01010001010000000000000515BI010000115925m
483.17Overflow pipe 200 mmBI01010001010000000000000515BI010000116030m
493.18Construction of RCC Circular Ground Service Reservoirs on Hillock of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top roof slab/dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion and food grade epoxy paint to inner face of the container and dome/slab, including refilling and disposing of surplus stuff , all labour and material charges, providing and fixing accessories such as M.S./Alluminium ladder/RCC Stairs inside and outside, manhole frame and cover, puddle collar, ventilators, satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints to all exposed surface of structure etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job include painting the name of the scheme and other details on the reservoir and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.(Aprox 2Mtr.Staging)BI01010001010000000000000515BI0100001161
503.19AT HARDI IPSBI01010001010000000000000515BI0100001162
513.2Hardi HW ---- 250 KLBI01010001010000000000000515BI0100001163250000Litre
523.21Providing and flxing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended upto date), as vertical pipes for RCC Reservoirs including specials required such as duckfoot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all resepect upto and from valve chamber as per direction of EIC, Technical Specification and Scope of work.BI01010001010000000000000515BI0100001164
533.22Hardi HW ---- 250 KLBI01010001010000000000000515BI0100001165
543.23Wash out pipe 100 mmBI01010001010000000000000515BI01000011666m
553.24Inlet pipe 250 mmBI01010001010000000000000515BI01000011676m
563.25Outlet pipe 250 mmBI01010001010000000000000515BI01000011685m
573.26Overflow pipe 250 mmBI01010001010000000000000515BI01000011696m
584Valves at Inlet/Outlet/Wash out/Over FlowBI01010001010000000000000515BI0100001170
594.01Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.BI01010001010000000000000515BI0100001171
604.02At Inlet of OHSRBI01010001010000000000000515BI0100001172
614.03100 mmBI01010001010000000000000515BI01000011733Each
624.04150 mmBI01010001010000000000000515BI01000011741Each
634.05At Outlet of OHSRsBI01010001010000000000000515BI0100001175
644.06150 mmBI01010001010000000000000515BI01000011766Each
654.07200 mmBI01010001010000000000000515BI01000011772Each
664.08At Overflow of OHSRsBI01010001010000000000000515BI0100001178
674.09150 mmBI01010001010000000000000515BI01000011793Each
684.1200 mmBI01010001010000000000000515BI01000011801Each
694.11At Washout of OHSRsBI01010001010000000000000515BI0100001181
704.12100 mmBI01010001010000000000000515BI01000011824Each
714.13At Inlet of CWRsBI01010001010000000000000515BI0100001183
724.14250 mmBI01010001010000000000000515BI01000011841Each
734.15At Outlet of CWRsBI01010001010000000000000515BI0100001185
744.16250 mmBI01010001010000000000000515BI01000011862Each
754.17At Overflow of CWRsBI01010001010000000000000515BI0100001187
764.18250 mmBI01010001010000000000000515BI01000011881Each
774.19At Washout of CWRsBI01010001010000000000000515BI0100001189
784.2100 mmBI01010001010000000000000515BI01000011901Each
794.21Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer of PN 1.0/1.6BI01010001010000000000000515BI0100001191
804.22100 mmBI01010001010000000000000515BI01000011928Each
814.23150 mmBI01010001010000000000000515BI010000119310Each
824.24200 mmBI01010001010000000000000515BI01000011943Each
834.25250 mmBI01010001010000000000000515BI01000011954Each
844.26SITC of Ultrasonic Level Transmitter suitable for measuring water level in reservoir, powered by solar panel with minimum 48 power back up or internal installed battery ( 5 years battery life with replacement warranty), with out put as GSM/GPRS + data logger , Sensor Material: PP, accuracy +/_ 0.2 %, as per detailed Technical specification, scope of work and direction of Engineer in charge.\nBI01010001010000000000000515BI0100001196
854.27Measuring range 0.0 to 6.0 mtrBI01010001010000000000000515BI01000011975Each
864.28Provision for Sectional Valve,Scour Valve and AirValve for Rising main, Distribution Main and Village Distribution Pipe Line .BI01010001010000000000000515BI0100001198
875Sectional valve ( BF/SV/FCV/flow meter) Chambers(25 No)BI01010001010000000000000515BI0100001199
885.01Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. \nAll kinds of soilsBI01010001010000000000000515BI0100001200
895.02upto 1.5 mtrsBI01010001010000000000000515BI0100001201189Cu.m.
905.03Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).BI01010001010000000000000515BI010000120210.8Cu.m.
915.04Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. \nM20 grade Nominal Mix / Design MixBI01010001010000000000000515BI010000120365.7Cu.m.
925.05Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.BI01010001010000000000000515BI0100001204742.5Sqm
935.06Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)BI01010001010000000000000515BI01000012053075Kg.
945.07Providing, hoisting and fixing up to floor five level precast reinforced concrete work in Nominal M20 grade mix including cost of required centering, shuttering, finishing, smooth with 6 mm thick cement plaster 1:3 (1 cement: 3 fine sand) on exposed surface complete excluding cost of reinforcementBI01010001010000000000000515BI01000012068.197Cu.m.
956Scour Valve Chambers(11No.)BI01010001010000000000000515BI0100001207
966.01Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. up to 1.5 m\nAll kinds of soilsBI01010001010000000000000515BI0100001208
976.02Size 1.2x1.2x.6BI01010001010000000000000515BI010000120915.84Cu.m.
986.03Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).BI01010001010000000000000515BI01000012102.376Cu.m.
996.04Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. \nM20 grade Nominal Mix / Design MixBI01010001010000000000000515BI0100001211
1006.05long wallBI01010001010000000000000515BI01000012121.188cum
1016.06short wallBI01010001010000000000000515BI01000012131.188cum
1026.07coverBI01010001010000000000000515BI01000012141.584cum
1036.08Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.BI01010001010000000000000515BI0100001215
1046.09Long wallBI01010001010000000000000515BI010000121623.76sqm
1056.1Short wallBI01010001010000000000000515BI010000121723.76sqm
1066.11coverBI01010001010000000000000515BI010000121815.84sqm
1076.12Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)BI01010001010000000000000515BI0100001219
1086.13taking steel @ 125 kg/cum of CC=0.36cumBI01010001010000000000000515BI0100001220497.75kg
1096.14Supplying and fixing Ferro cement cover with CI frame for chambers and MH of size 600x450 mm to withstand 3 t centre point load and minimum unfractired load of 1 tBI01010001010000000000000515BI010000122111each
1106.15Cement plaster 1: 4, 20 mm th. on the outside and inside on RCC walls.BI01010001010000000000000515BI0100001222
1116.16Long wallBI01010001010000000000000515BI010000122323.76sqm
1126.17short wallBI01010001010000000000000515BI010000122423.76sqm
1136.18coverBI01010001010000000000000515BI010000122547.52sqm
1147Air Valve Shaft/chambers(17 No.)BI01010001010000000000000515BI0100001226
1157.01Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift upto 1.5Mtr. Including taking out the excavated soil and depositing and refilling of jhiri with watering and ramming and disposal of surplus excavated soil as directed within a lead of 50Mtr. Hard / dense soil upto 1.50 mtr.BI01010001010000000000000515BI010000122720.4Cum
1167.02Providing and laying cement 'concreting including curing, compaction etc. complete using stone aggregate 40 mm nominal size in foundation and plinth, excluding cost of shuttering, using 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate)BI01010001010000000000000515BI01000012281.7Cum
1177.03Providing & laying cement concrete for all RCC work including curing, compaction etc complete using stone aggregate 40mm nominal size (crusher broken) in foundation plinth, excluding the cost of shuttering using 1 cement : 1.5 sand : 3 aggregateBI01010001010000000000000515BI01000012298.773Cum
1187.04P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. 50 mm dia.B classBI01010001010000000000000515BI010000123076.5mtrs
1197.05Centering and shuttering with ply 'wood or steel sheets including 'strutting, propping, bracing 'bothways and removal of formwork 'for superstructure upto 4.5 m height above plinth level for walls (any thickness) including attached pilaster, buttresses etcBI01010001010000000000000515BI0100001231
1207.06Upto plinth levelBI01010001010000000000000515BI010000123228.825sqm
1217.07Above Plinth levelBI01010001010000000000000515BI010000123360.853sqm
1227.08Locking facility with MS boxBI01010001010000000000000515BI0100001234850KG
1238SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. \nNote: Rates are exclusive of tail piece / dismantling joints and earth work.BI01010001010000000000000515BI0100001235
1248.01At Pump House BassiBI01010001010000000000000515BI0100001236
1258.02EFM 200 mmBI01010001010000000000000515BI01000012371Each
1268.03SITC of Bulk Flow Meter with removable mechanism class \"B\" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. \nNote: Rates are exclusive of tail piece / dismantling joints and earth work.BI01010001010000000000000515BI0100001238
1278.04For Service ReservoirBI01010001010000000000000515BI0100001239
1288.05BFM 80 mmBI01010001010000000000000515BI01000012404Each
1298.06BFM 200 mmBI01010001010000000000000515BI01000012411Each
1309Providing,Laying,Jointing and Commissioning of Rising Main and Distribution Network.BI01010001010000000000000515BI0100001242
1319.01Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISi marked K-7 grade S&S pipes as per 15:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.BI01010001010000000000000515BI0100001243
1329.0280 mm DI K-7BI01010001010000000000000515BI0100001244400m
1339.03100 mm DI K-7BI01010001010000000000000515BI01000012454100m
1349.04150 mm DI K-7BI01010001010000000000000515BI010000124625300m
1359.05200 mm DI K-7BI01010001010000000000000515BI0100001247200m
1369.06250mm DI K-7BI01010001010000000000000515BI010000124811900m
1379.07Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . \nNote : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.\nSupply may be in coil or straight length in 6 M/12 M.BI01010001010000000000000515BI0100001249
1389.08HDPE PE-100 PN-06BI01010001010000000000000515BI0100001250
1399.0975 mmBI01010001010000000000000515BI010000125166275m
1409.190 mmBI01010001010000000000000515BI01000012524450m
1419.11110 mmBI01010001010000000000000515BI01000012539900m
1429.12Additional Rising Main for Connecting Local Sources to CWR at Hardi .BI01010001010000000000000515BI0100001254
1439.13HDPE PE-100 PN-10BI01010001010000000000000515BI0100001255
1449.1490 mm diaBI01010001010000000000000515BI01000012563400m
1459.15110 mm diaBI01010001010000000000000515BI01000012573200m
1469.16Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). \nNote : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.\nSupply of pipe shall be in straight length in 6/12 M.BI01010001010000000000000515BI0100001258
1479.17HDPE PE-100 PN-06BI01010001010000000000000515BI0100001259
1489.18125 mmBI01010001010000000000000515BI01000012609700m
1499.19140 mmBI01010001010000000000000515BI01000012617750m
1509.2160 mmBI01010001010000000000000515BI01000012625150m
1519.21180 mmBI01010001010000000000000515BI0100001263600m
1529.22200 mmBI01010001010000000000000515BI0100001264700m
1539.23225 mmBI01010001010000000000000515BI0100001265200m
1549.24HDPE PE-100 PN-10BI01010001010000000000000515BI0100001266
1559.25125mm diaBI01010001010000000000000515BI0100001267200m
1569.26140mm diaBI01010001010000000000000515BI01000012682000m
1579.27Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (SECTIONAL VALVES) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.BI01010001010000000000000515BI0100001269
1589.28Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6BI01010001010000000000000515BI0100001270
1599.2980 mmBI01010001010000000000000515BI010000127134Each
1609.3100 mmBI01010001010000000000000515BI010000127227Each
1619.31125 mmBI01010001010000000000000515BI010000127318Each
1629.32150 mmBI01010001010000000000000515BI010000127417Each
1639.33200 mmBI01010001010000000000000515BI010000127510Each
1649.34250 mmBI01010001010000000000000515BI010000127610Each
1659.35Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside .Fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem. Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.\nNote: Rates are exclusive of connecting tee, pipe piece and earth work.BI01010001010000000000000515BI0100001277
1669.36Class PN 1.6BI01010001010000000000000515BI0100001278
1679.3740 mmBI01010001010000000000000515BI010000127932Each
1689.3850 mmBI01010001010000000000000515BI010000128015Each
1699.39Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths DI standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 9523-2000 or as amended up to date, such as tees, bends, tapers, caps etc. within trenches in DI pipe line complete including all material, labour, taxes, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge (excluding earth work).BI01010001010000000000000515BI0100001281
1709.4A/S Tee , Bend, Reducer (All End Socketed)BI01010001010000000000000515BI0100001282
1719.41Upto 300 mm DiameterBI01010001010000000000000515BI01000012831900kG
1729.42Double Flange Pipe (upto 1 mtr. length)BI01010001010000000000000515BI0100001284
1739.43Upto 300 mm DiameterBI01010001010000000000000515BI01000012851400Kg
1749.44Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr.BI01010001010000000000000515BI0100001286
1759.45All kind of soilBI01010001010000000000000515BI0100001287
1769.46For HDPE pipe line dia up to 110 mm.BI01010001010000000000000515BI010000128882553RMT
1779.47For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm.BI01010001010000000000000515BI010000128941025RMT
1789.48For dia above 150 mm and up to 350 mm nominal.BI01010001010000000000000515BI010000129012240RMT
1799.49Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr.BI01010001010000000000000515BI0100001291
1809.5In soft Rock;For HDPE pipe line dia up to 110 mmBI01010001010000000000000515BI01000012929172RMT
1819.51For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm.BI01010001010000000000000515BI01000012935010RMT
1829.52For dia above 150 mm and up to 350 mm nominal.BI01010001010000000000000515BI01000012941360RMT
1839.53Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body- Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030, Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 420/ Gr 1.4021 Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2. Insersion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.BI01010001010000000000000515BI0100001295
1849.54Pilot Operated Plunger Type Flow Control ValveBI01010001010000000000000515BI0100001296
1859.55100 mmBI01010001010000000000000515BI01000012973Each
1869.56150 mmBI01010001010000000000000515BI01000012981Each
1879.57Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.BI01010001010000000000000515BI01000012995343.96CuM
1889.58Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.BI01010001010000000000000515BI01000013002137.9CuM
1899.59Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.BI01010001010000000000000515BI0100001301
1909.6M20 grade Nominal Mix\n1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm\nnominal size).BI01010001010000000000000515BI01000013023206.85CuM
19110Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer.\nApply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification. (2 No's)\nBI01010001010000000000000515BI0100001303
19210.01400 mm Dia 8 mm thick casing pipe with protective coating.BI01010001010000000000000515BI0100001304175RM
19311Provision for construction of civil worksBI01010001010000000000000515BI0100001305
19411.01Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect.---Construction of Boundry Wall at Campus including ESR (4 No.),and proposed HW (1 No's)BI01010001010000000000000515BI0100001306480RM
19511.02Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.BI01010001010000000000000515BI01000013071200Kg
19612Provision of providing 9000 House Connections to Individual House Hold ,Linking with Aadhar and Geo tagging (For 28 Villages)BI01010001010000000000000515BI0100001308
19712.01Providing service connection as per technical specification & standard drawing as per relevant IS code (amended up to date) from all kind of water mains up to consumer meter (complete job). This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil including demolishing of CC, WBM, Black top etc of all thickness, this also includes providing & fixing of all fitting duly approved in acordance with ISO/DTR 9080 as per specification for potable water including approved make of MS clamp with sadle piece gunmetal ferrule (ISI Mark), gunmatel NRV (ISI make), valve (IS :778) and required specials with MDPE pipe as per ISO 41427 with flushing, cleaning, disinfecting and testing of pipe line complete required for replacment and restoration of leak proof service connection. The service line should be laid at least 45 cm below road surface complete in all respect. the labour charges includes fixing of meter (meter shall be provided by consumer/dept. free of cost)BI01010001010000000000000515BI0100001309
19812.02Average length upto 5 m of 20 mm MDPE pipe.BI01010001010000000000000515BI01000013109000Nos.
19912.03Extra length of 20 mm MDPE pipe including excavation, proving, laying and jointing for length of service line above 5.00 mtr.BI01010001010000000000000515BI01000013111800Nos.
20012.04Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.BI01010001010000000000000515BI0100001312
20112.05M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).BI01010001010000000000000515BI01000013131620Cum
20212.06Survey of all properties, preparation of GIS based consumer mapping of consumer water connection database, plotting assets on GIS map etc (Satellite image will be provided by the Department)BI01010001010000000000000515BI01000013149000Nos
20312.07Data entry of existing FHTCs in rural area under JJM on website ejalshakti.gov.in; work includes visiting the village for collecting basic data consumers like i.e. Aadhar no./ration card/voter ID/BPL card/ PAN card/driving licence/passport/Antyodaya card/mobile no. etc. and entering the details on the above website. The cost also includes computer and operator.BI01010001010000000000000515BI01000013159000Nos
20413Cost Estimate for Annual Operation and Maintenence Expenditure for 10 year's.BI01010001010000000000000515BI0100001316
20513.01Cost for Basic Service Charges, Administration and Management, Running of Office, Staff Quarters, Comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, Cost of material required for maintenance & repairs, Cost of Lubricants, salts for producing chlorine, chemicals,(except PAC & Chlorine) Consumables, Spare Parts (if the spare parts supplied to PHED are used in emergency) as per Scope of Work & terms & conditions of contract for 10 year after defect laibility period of one year.BI01010001010000000000000515BI0100001317
20613.02O&M of entire system for Defect laibility period of one year (free of cost)BI01010001010000000000000515BI0100001318
20713.03Ist YearBI01010001010000000000000515BI010000131912Month
20813.04IInd YearBI01010001010000000000000515BI010000132012Month
20913.05IIIrd YearBI01010001010000000000000515BI010000132112Month
21013.06IV th YearBI01010001010000000000000515BI010000132212Month
21113.07V thYearBI01010001010000000000000515BI010000132312Month
21213.08VI thYearBI01010001010000000000000515BI010000132412Month
21313.09VII thYearBI01010001010000000000000515BI010000132512Month
21413.1VIII thYearBI01010001010000000000000515BI010000132612Month
21513.11IX thYearBI01010001010000000000000515BI010000132712Month
21613.12X thYearBI01010001010000000000000515BI010000132812Month

AI Tender Summary

OUR REF NO 28476488
AUTHORITY Government Departments
TENDER VALUE 24.95 Crore
LAST DATE 29-07-2021
Authority
Authority Name Public Health Engineering Department
Work Description Bids For The Retrofitting Works Of 28 Villages Of Bassi Tehsil Under Bassi-Bisalpur Water Supply Project To Carry Out Works Of Providing Functional Household Tap Connections Under Jal Jeevan Mission Jjm
Basic Detail
Tender No NIT No. 06 / 2021-22 SE PHED PROJECT CIRCLE JAIPUR
Bidding Type Tender
Location
City BASSI
State Rajasthan
Key Dates
Publish Date 10 Jul 2021
Submission Date 29 Jul 2021
Open Date 30 Jul 2021
Finance
Tender Value 24.95 Crore
Tender Fee 10000
EMD Ref. Documents
Exemption Not Available
Document List
Bid_Revised_Document_Bassi.pdf
Tendernotice_1.pdf
BOQ_413937.xls
4E356F4A-5270-43B5-A3C2-C726F31F2737.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 30, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Bid_Revised_Document_Bassi.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_413937.xls

html

4E356F4A-5270-43B5-A3C2-C726F31F2737.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders