| 1 | 1 | Demolition of cement concrete in ground floors and pavings not exceeding 15cm thickness (Below or above ground level) un-reinforced complete all as specified and directed. | | 2 | Cum |
|---|
| 2 | 2 | M&L for (PCC 1:4:8) type D2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete. | | 2 | Cum |
|---|
| 3 | 3 | M&L for cement concrete 1:3:6 Type C2 using 20 mm graded aggregate as in plinth protection | | 40 | Sqm |
|---|
| 4 | 4 | Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for | | 11 | Cum |
|---|
| 5 | 5 | M&L for providing cemnet concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in coping, bed plates including weathering, slightly rounded or chamfered angles and\nthroating complete all as specified and directed. | | 11 | Cum |
|---|
| 6 | 6 | Taking down cement plaster on brick or stone wall etc including raking out joints hacking for keys scrubbing down with water etc. | | 350 | Sqm |
|---|
| 7 | 7 | M&L 15 mm rendering in CM 1:4 on other than fair faces of brickwork or concrete surafaces. | | 500 | Sqm |
|---|
| 8 | 8 | M&L for applying two coat of camouflage painting with acrylic exterior weather coat painting over a coat of primer of alakali resistant on new plaster surface incl preparation (Make Appex ultima, Extra maximum ultra, berger paints weather coat) | | 500 | Sqm |
|---|
| 9 | 9 | Demolition of RCC of any description and any position not othervise provided for | | 3 | Cum |
|---|
| 10 | 10 | M&L for RCC type B1 1:2: 4 (20 mm graded agg) in pre cast posts, fencing posts, straining or terminals posts, struts etc for fencing average sectional area exc 100 and n.exc 250 Sqcm with or without chamfered angles and flat splayed rounded or mitered tops as directed and fixed. | | 3 | Cum |
|---|
| 11 | 11 | M&L TMT bars 10 mm dia and over cut to length bend to shape required, including cranking, bending spirally for hoping for columns hooking ends and binding with MS steel wire (annealed) not less than 0.90 mm dia complete all as specified and directed. | | 300 | Kg |
|---|
| 12 | 12 | M/L mild steel TMT bars 8mm dia cut to length bent to shape required and binding with ms wire anealed not less than 0.9mm dia, complete all as spacified and directed. | | 150 | kg |
|---|
| 13 | 13 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed. | | 150 | RM |
|---|
| 14 | 14 | S/F MS steel post struts fencing post including cutting top to shape,drilling holes notching for wire etc including all necessary drilling bolting andd similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. | | 5000 | Kg |
|---|
| 15 | 15 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on newly untreated surfaces of steel over 10cm in width or girth not otherwise described | | 260 | Sqm |
|---|
| 16 | 16 | M &L for preparation of new steel surfaces and applying two coats of black bituminious paint exceeding 10cm in width or girth complete all as specified and directed. | | 30 | Sqm |
|---|
| 17 | 17 | M&L for one coat of synthetic enamel paint over a coat of red oxide primer on old steel surfaces of steel over 10cm in width or girth not otherwise described complete all as specified and directed. | | 1000 | Sqm |
|---|
| 18 | 18 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on newly untreated surfaces of steel not exceeding 10cm in width or girth not otherwise described complete all as specified and directed. | | 30 | 10 Rm |
|---|
| 19 | 19 | Dismantling old GI barbed wire of any specifications from the existing posts complete all as specified and directed. | | 10400 | RM |
|---|
| 20 | 20 | S&F in repair galvanized two stranded steel barbed wire 2.24 mm dia barbed with 2mm dia berb at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire, staple or steel pins etc (each line wire to be measured) complete all as specified and directed. | | 100 | 100 RM |
|---|
| 21 | 21 | Fixing only, galvanized two stranded steel barbed wire 2.24 mm dia barbed with 2mm dia berb at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire, staple or steel pins etc complete all as specified and directed. | | 30 | 100 RM |
|---|
| 22 | 22 | Demolition of brick work in cement mortar incl all quions, arches,pillers etc, but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and directed. | | 30 | Cum |
|---|
| 23 | 23 | M&L brick work with sub class b bricks strait or curved on plan exc 6 M mean radius built in CM 1:4 complete all as specified and directed. | | 30 | Cum |
|---|
| 24 | 24 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standrad , rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. | | 200 | Sqm |
|---|
| 25 | 25 | Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed. | | 700 | Kg |
|---|
| 26 | 26 | S&F Concertina coil 900/1050 mm Dia/56 Loops/2.5 mm core wire. Coil Diameter:1050 mm. Type of Strip: Heavy Galvanized (IS 1730) Type of Core Wire: Heavy Galvanized (IS 280-2006) Core wire Diameter: 2.50mm Dia Zinc coating to Strip: Minimum 200 GSM/Sq mm, Zine Coating on wire: Minimum 275 GSM/Sq mm (IS 6745-1972 reaffirmed 2006). Tensile Strength of wire 1400-1500 N/Sq mm Weight: 14.63 Kg (+5%) Number of Loops: 56 Blade Length: 22mm Barb Profile Medium Blade (MBBT) Distance Between Barb 35mm. Strechable length 12 mtrs. Type of clip Hardened Steelin Galvanized steel (83 Nos coil per Km) complete all as specified and directed. | | 2004 | Kg |
|---|
| 27 | 27 | S&F framed work such as grills, grating etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. | | 250 | Kg |
|---|
| 28 | 28 | M&L for broken glass coping on top of walls in cement mortar (1:3) complete all as specified and directed. | | 193 | Sqm |
|---|