Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #28475999

Repair Maint Of Internal Electrification And Certain Allied Works At 733 Eme Wksp 853 Asc 877 At Mule Asc Bn And 29 Mob Fvh At U Area Under Age Em Of Ge Sukna

Issued by Statutory Bodies & Commissions/Committees · Sukna, West Bengal
Tender Value
47 Lakhs
Estimated cost
Bid Submission
20 Jul 2021
0 days left
EMD
94000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sukna → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair Maint Of Internal Electrification And Certain Allied Works At 733 Eme Wksp 853 Asc 877 At Mule Asc Bn And 29 Mob Fvh At U Area Under Age Em Of Ge Sukna

BOQ

Name of Work : REPAIR / MAINT OF INTERNAL ELECTRIFICATION AND CERTAIN ALLIED WORKS AT 733 EME WKSP, 853 ASC, 877 AT MULE ASC BN AND 29 MOB FVH AT U AREA UNDER AGE E/M OF GE SUKNA
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including PVC casing caping (double lock pattern) and accessories on wall / ceiling surfaces etc. with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc including all other fixing accessories for one light / fan / exhaust fan point controlled by one 5 / 6 Amps switch and including taking down complete all as specified and directed.\nMake of cable :- Havells / KEI / Polycab / RR Kabel Ltd. / HPL\nMake of PVC casing caping:- Richa Cables / AKG Industries / Harsh Electro Systems\n480Per Point
22All as per Sl. item No. 1 above but for one 5 / 6 Amps socket outlet point on the same board.\n30Per Point
33All as per Sl. item No. 1 above but for one 5 / 6 Amps socket outlet point on independent board.\n100Per Point
44All as per Sl. item No. 1 above but for one 5 / 6 Amps socket outlet point on independent board but below the switch board of light points in the same vertical plane.\n30Per Point
55All as per Sl. item No. 1 above but for one light point controlled by two, 2 - way switches.\n10Per Point
66M&L point wiring with 2.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including PVC casing caping (double lock pattern) and accessories on wall / ceiling surfaces etc. with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for 15 / 16 Amps socket outlet on independent board and including taking down complete all as specified and directed.\nMake of cable :- Havells / KEI / Polycab / RR Kabel Ltd. / HPL\nMake of PVC casing caping:- Richa Cables / AKG Industries / Harsh Electro Systems\n100Per Point
77M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch and including cutting chasing (as required) and making good surfaces to match with adjoining surface & including taking down complete all as specified and directed.\nMake of cable:- Havells / KEI / Polycab / RR Kabel Ltd. / HPL\nMake of PVC Conduit:- Richa Cables / AKG Industries / Harsh Electro Systems / Panasonic (Anchor)\n260Per Point
88All as per Sl. item No. 7 above but for one 5 / 6 Amps socket outlet point on independent board.\n30Per Point
99M&L point wiring with 2.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for 15 / 16 Amps socket outlet on independent board and including cutting chasing (as required) and making good surfaces to match with adjoining surface and including taking down complete all as specified and directed.\nMake of cable:- Havells / KEI / Polycab / RR Kabel Ltd. / HPL\nMake of PVC Conduit:- Richa Cables / AKG Industries / Harsh Electro Systems / Panasonic (Anchor)\n30Per Point
1010S&F switch piano flush type one way, 5 / 6 Amps, 240 volt complete all as specified and directed.\nMake :- Havells / Anchor / Legrand\n730Each
1111All as per item No. 10 above but two way switch.\n\n20Each
1212S&F socket outlet 5 pin 5 / 6 Amps, 240 volts complete all as specified and directed. \nMake :- Havells / Anchor / Legrand\n30Each
1313S&F switch socket combination 5 pin, 5 / 6 Amp, flush type complete all as specified and directed.\nMake :- Havells / Anchor / Legrand\n160Each
1414S&F switch socket combination 2 in 1, 6 Pin, 5 & 15 Amp, flush type universal complete all as specified and directed.\nMake :- Havells / Anchor / Legrand\n130Each
1515S&F bell push one way, 5/6 Amp, 240 V complete all as specified and directed.\nMake :- Havells / Anchor / Legrand\n40Each
1616S&F call bell, ding dong, AC 240 V, single pole complete all as specified and directed.\nMake :- Havells / Anchor / Legrand\n40Each
1717S&F ceiling rose, surface bakelite 65 x 50 mm three terminal complete all as specified and directed.\nMake:- Havells / Anchor / Legrand\n450Each
1818S&F stepped type electronic fan regulator two module, with 5 step, AC 50 Hz 240 Volts grade complete all as specified and directed.\nMake :- Havells / Anchor / Legrand\n110Each
1919S&F angular lamp holder, PVC / Polycarbonate type with back plate for fixing of retrofit lamp 240 volt including taking down complete all as specified and as directed.\nMake :- Havells / Anchor / Legrand\n145Each
2020S&F MCB SP 6 to 32 Amp, 10 kA, 240V 'C' curve complete all as specified and as directed. \nMake :- L&T / Havells (Brand-Max³, EURO-II) / Panasonic / Hager / ABB / Legrand\n230Each
2121All as per items No 20 above but MCB SPN.\n\n75Each
2222All as per items No 20 above but MCB TPN 40 to 63 Amp.\n12Each
2323S & F blanking plate suitable for distribution boards complete all as specified and directed.\nMake :- L&T / Havells / Panasonic / Hager / ABB / Legrand\n150Each
2424S&F sheet metal enclosure suitable for MCB, SPN 2 way, without bus bar and including taking down, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.\nMake :- L&T / Havells / Panasonic / Hager / ABB / Legrand\n10Each
2525S&F metal plug and socket DB, double pole 240 volts and including one 20 Amp MCB SPN, C-Curve & including taking down complete all as specified and directed. \nMake :- L&T / Havells / Panasonic / Hager / ABB / Legrand\n10Each
2626S&F MCB DB, SPN 6 way, IP-30, IK09, single door type, with 100A copper neutral and earth bus bar for fixing MCB including taking down, fixed flush to wall & making good the disturbed surfaces complete all as specified and directed.\nMake:- L&T / Havells / Panasonic / Hager / ABB / Legrand\n25Each
2727All as per items No 26 above but 8 way\n\n20Each
2828All as per items No 26 above but 12 way\n\n15Each
2929S&F VTPN DB, 4 way, IP-30, IK 08, single door type, with 250 A copper neutral and earth bus bar, suitable for fixing upto 160 Amp MCCBs as incomer and including taking down, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.\nMake :- L&T / Havells / Panasonic / Hager / ABB / Legrand\n5Each
3030All as per items No 29 above but 6 way\n\n5Each
3131S&F MCCB 4 pole 100 Amps breaking capacity 16 KA, Ics = 100% Icu including spreader link complete all as specified and directed. \nMake :- L&T / Havells (Brand- HIM & HIX) / Panasonic / Hager / ABB / Legrand\n5Each
3232All as per items No 31 above but 125 Amps\n\n5Each
3333M & L for sub main wiring with 2 runs of 2.5 Sqmm main wire alongwith 1 run of 2.5 Sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade copper conductor cable, drawn through and including adequate size PVC casing caping (double lock pattern) with all fittings & accessories on walls / ceiling surfaces etc., including taking down complete all as specified and directed.\nNOTE :- Two runs of main copper conductor, one run of earth wire and one run of PVC casing caping shall be measured as one unit length.\nMake of cable :- Havells / KEI / Polycab / RR Kabel Ltd. / HPL\nMake of PVC casing caping:- Richa Cables / AKG Industries / Harsh Electro Systems\n\n450RM
3434All as per item No. 33 above but with 2 runs of 4 sqmm main wire along with 1 run of 4 sqmm earth wire.\n\n500RM
3535All as per item No. 33 above but with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire.\n\n400RM
3636All as per item No. 33 above but with 2 runs of 10 sqmm main wire along with 1 run of 10 sqmm earth wire.\n\n300RM
3737S&F LED light fitting 1 x 18 / 20 watt batten type 230 Volts, 4 feet long, extruded polycarbonate housing & extruded polycarbonate diffuser, suitable for surface mounting, Lumen Efficacy 100 Lm/Watt (minimum), colour temperature 5700K (minimum), CRI 80 (minimum), IP 20, PF 0.90 (minimum), THD 20% (Maximum), with in-built electrnoic driver with APFC, in-built surge protection 2 KV (minimum) inlcuding all fixing arrangement, electrically connecting from ceiling rose to light fitting & including taking down complete all as specified and directed.\nMake:- Indiabulls LED / C&S / Crompton / Surya\n450Each
3838S&F LED light fitting 1 x 9 / 10 watt, 230 Volts, 2 feet long, extruded aluminium housing & extruded polycarbonate diffuser, suitable for surface mounting, system efficacy 100 Lm/watt (minimum), colour temperature 5700K (minimum), CRI 80 (minimum), PF 0.90 (minimum), THD 10% (Maximum), with integrated high effeciency electrnoic driver with APFC, in-built surge protection 5 KV (minimum) inlcuding all fixing arrangement, electrically connecting from ceiling rose to light fitting & taking down complete all as specified and directed.\nMake:- Indiabulls LED / C&S / Crompton / Surya\n\n47Each
3939S&F 9 / 10 watt LED Bulk head fitting including electronic driver and SMD LED lamp, polycarbonate housing & opal polycarbonate diffuser, Lumen Efficacy 100 Lm / watt (minimum), colour temperature 5700K (minimum), CRI 80 (minimum), IP-65, PF 0.95 (minimum), THD 10% (maximum), in-built surge protection 5 KV (minimum) and including electrically connecting from celing rose to light fitting and taking down complete all as specified and directed.\nMake:- Indiabulls LED / C&S / Crompton / Surya\n\n170Each
4040S&F 1 x 34 / 36 watt, LED Panel light fitting, square shape (2 x 2 ft), suitable for recess mounting in ceiling, epoxy white powder coated, die cast aluminium housing & opal acrylic diffuser, colour temperature 5700 K (minimum), 230 Volts, total system lumen 3600 Lm (minimum), CRI 80 (minimum), IP 20, PF 0.95 (minimum), THD 20% (Maximum), with integrated high effeciency electrnoic driver with APFC, inbuilt surge protection 2 KV (minimum), inlcuding electrically connecting & taking down complete all as specified and directed.\nMake:- Indiabulls LED / C&S / Crompton / Surya\n\n45Each
4141S&F 1 x 15 / 16 watt, LED down light fitting, square shape, suitable for recess mounting, extruded polycarbonate housing & extruded polycarbonate diffuser, colour temperature 5700 K (minimum), 230 Volts, lumen efficacy 100 Lm/watt (minimum), CRI 80 (minimum), PF 0.90 (minimum), THD 20% (Maximum), with integrated high effeciency electrnoic driver with APFC, inbuilt surge protection 2 KV (minimum), inlcuding electrically connecting & taking down complete all as specified and directed.\nMake:- Indiabulls LED / C&S / Crompton / Surya\n85Each
4242S&F 1 x 15 / 16 watt, LED suspended down light fitting, cylindrical round shape, suitable for suspended mounting with the help of 2 m (minimum) long suspension wire, epoxy powder coated die cast aluminium housing & clear glass diffuser, 230 Volts, colour temperature 5700 K (minimum), CRI 80 (minimum), PF 0.95 (minimum) and inlcuding electrically connecting & taking down complete all as specified and directed.\nMake:- Indiabulls LED / C&S / Crompton / Surya\n6Each
4343S&F decorative wall mounted light fitting with in-built 1 x 6 watt LED with opal glass diffuser and including electrically connecting & taking down complete all as specified and directed.\nMake:- Indiabulls LED / C&S / Crompton / Surya\n30Each
4444S&F LED batten light fitting 1 x 10 watt inverter (backup) type, 230 Volts, suitable for surface mounting, lithium ion battery with minimum 4 hrs backup time, extruded polycarbonate housing & extruded polycarbonate diffuser, lumen efficacy 100 Lm / watt (minimum), colour temperature 650 0K (minimum), CRI 80 (minimum), IP-20 (minimum), PF 0.90 (minimum), in-built surge protection 3.5 KV (minimum) inlcuding all fixing arragnement and electrically connecting from ceiling rose to light fitting & taking down complete all as specified and directed.\nMake:- Indiabulls LED / C&S / Crompton / Surya\n485Each
4545S&F 9 watt LED bulb, inverter (backup) type, A19 shape with B22 base 230 Volts, battery with minimum 4 hrs backup time, frosted diffuser, suitable for surface mounting, total system lumen 900 Lm (minimum) on supply and 400 Lm (minimum) on battery, colour temperature 6500K (minimum), CRI 80 (minimum) & taking down complete all as specified and directed.\nMake:- Indiabulls LED / C&S / Crompton / Surya\n400Each
4646S&F \"EXIT\" / \"ENTRY\" LED signage box of minimum size 325 x 425 x 365 mm with and including 6 watt LED inside, electrically connecting & taking down complete all as speficified and directed.\n5Each
4747Note for Sl Item Nos. 35 to 44:- Contractor has to submit LM-79 & LM-80 and 3rd party NABL accredited lab test report for ALL LED fittings conforming to technical specifications beforesample approval.\n
4848S&F ceiling fan 1200 mm (minimum) sweep, BEE 5 star rated, with BLDC technology, AC single phase 230 V, 350 RPM, air delivery 220 m³/minute (minimum), with and including smart remote with long lasting batteries to control speed, multi pairing, timer and other intelligent memory functions, suspended from fan hook and including electrically connecting with twisted three core PVC insulated unsheathed flexible cord of 0.75 Sqmm copper conductor from ceiling rose to ceiling fan complete all as specified and directed.\nMake :- Havells, Model - EFFICIENCIA NEO or equivalent in Orient / Ram Ratna Electricals Ltd (RRE)\n110Each
4949S&F exhaust fan 300 mm sweep, metal body, 1200 RPM (minimum), AC single phase, 230 V, 50Hz with bird guard, nuts, screws, bolts including electrical connection, writing MES number in 2 cm height with synthetic enamel paint complete all as specified and directed.\nMake:- Havells, Model - Ventil Air - DSP or equivalent in Orient / Ram Ratna Electricals Ltd (RRE)\n21Each
5050S&F exhaust fan 250 mm sweep, non metallic plastic body, AC single phase, 230 V, 50Hz with & including self closing louvers, nuts, screws, bolts of specified sizes, electrical connection with twisted three core PVC insulated unsheathed flexible cord of size 0.75 sqmm copper conductor from ceiling rose to exhaust fan and writing MES number in 2 cm height with synthetic enamel paint complete all as specified and as directed.\nMake :- Havells, VentilAir - DX or equivalent in Orient / Ram Ratna Electricals Ltd (RRE)\nNote for Sl Item No 48 to 50:- The quoted rate is including for taking down and depositing old fan to MES store.\n15Each
5151M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire of 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point and including dismantling complete all as specified and directed.\n\nNote:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.\n18Each Set
5252S&F in repairs earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.\n250RM
5353S&F in repairs test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hex. head screw complete all as specified and directed.\n18Each
5454S&F in repairs synthetic PVC insulator suitable for fixing earth continuity conductor on wall / roof with & including GI nuts, bolts and washers complete all as specified and directed.\n200Each

AI Tender Summary

OUR REF NO 28475999
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47 Lakhs
LAST DATE 20-07-2021
Authority
Authority Name Military Engineer Services
Work Description Repair Maint Of Internal Electrification And Certain Allied Works At 733 Eme Wksp 853 Asc 877 At Mule Asc Bn And 29 Mob Fvh At U Area Under Age Em Of Ge Sukna
Basic Detail
Tender No GE Sukna/8292
Bidding Type Tender
Location
City Sukna
State West Bengal
Key Dates
Publish Date 10 Jul 2021
Submission Date 20 Jul 2021
Open Date 22 Jul 2021
Finance
Tender Value 47 Lakhs
Tender Fee 500
EMD 94000
Exemption Not Available
Document List
Tendernotice_1.pdf
2E914D6B-5A17-4031-BA90-CE88A2C33352.html
Tender8292_2ndCall.pdf
BOQ_511443.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 22, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

2E914D6B-5A17-4031-BA90-CE88A2C33352.html

pdf

Tender8292_2ndCall.pdf

xls

BOQ_511443.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail