Repair/Maint Of Summer Appliances W/C , Refg , Geyser , Ac And Voltage Stabilizer And Allied Works At Af Stn Purnea, GE AF PURNEA-Bihar

Military Engineer Services-MES has published Repair/Maint Of Summer Appliances W/C , Refg , Geyser , Ac And Voltage Stabilizer And Allied Works At Af Stn Purnea. Submission Date for this Tender is 30-07-2021. Voltage Stabiliser Tenders in GE AF PURNEA Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

28475370
Corrigendum : Repair/Maint Of Summer Appliances W/C , Refg , Geyser , Ac And Voltage Stabilizer And Allied Works At Af Stn Purnea
Open Tender
Indian
Bihar
GE AF PURNEA
30-07-2021

Tender Details

Repair/Maint Of Summer Appliances W/C , Refg , Geyser , Ac And Voltage Stabilizer And Allied Works At Af Stn Purnea

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Jul-2021 NIT Corrigendum Other 23-07-2021
2 23-Jul-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-07-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/MAINT OF SUMMER APPLIANCES W/C, REFG, GEYSER, AC & VOLTAGE STABILIZER AND ALLIED WORKS AT AF STN PURNEA
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down defective Refrigerator 155/165/170/175/210/315 litrs Capacity including Transportation from MES Store Yard/Site to Workshop and back including re-fixing/reinstalling, Testing, Connecting the same after replacement of Defective parts/Burnt Compressor Selected Unit with new Compressor obtained from authorised dealer including Flushing of Con-denser and Charging with required quantity of appropriate Refrigerant Gas, complete all as specified and as directed.\nNote:- Change of spare parts shall be measured separately under relevant item here-in-after as supply only rates fixing charges for spare parts shall deemed to be inclusive in the quoted rates. Old replaced material has to be shown to Engr-in-Charge measured under sch of credit.\n BI01010001010000000000000515BI0100001113 2 EACH JOB
2 2 Supply only Ice Cooling Chamber (as Approved) for Refrigerator 180/210/315 LITRE Capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.\n BI01010001010000000000000515BI0100001114 1 EACH
3 3 Supply only Starting Relay (OPEN TYPE/BOX TYPE) for Refrigerator of any Capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.\n 3 EACH
4 4 Supply only chiller tray for refrigerator for 300 ltrs Capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.\n\n BI01010001010000000000000515BI0100001115 1 Each
5 5 Supply only Chiller tray for refrigerator for 165 litrs Capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.\n BI01010001010000000000000515BI0100001116 1 Each
6 6 Supply only Vegitable tray for refrigerators 165 ltr Capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.\n 1 Each
7 7 Supply only vegitable tray for refrigerators 286/300litre capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.\n 1 Each
8 8 Supply only door hinges suitable for referigerator 300/ 165 litre Capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.\n 1 Each
9 9 Supply only PVC refrigerator stand suitable for 286/310 litre refrigerator for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.\n 1 Each
10 10 Supply only PVC refrigerator stand suitable for 165 litre refrigerator for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.\n 1 Each
11 11 Supply only door rubber inner liner suitable for refrigerator capacity 165 ltrs for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.\n 1 Each
12 12 Supply only door rubber inner liner suitable for refrigerator Capacity 286/300 ltrs for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.\n 1 Each
13 13 Supply only door rubber inner liner (magnetic) suitable for water cooler capacity 40 ltrs for fixing against defective parts of Water cooler taking down under item No 23 here in before complete all as specified and as directed.\n 1 Each
14 14 Supply only door rubber inner ( Magnetic suitable for water cooler Capacity 80 ltrs for fixing against defective parts of Water cooler taking down under item No 23 here in before complete all as specified and as directed.\n 1 Each
15 15 Supply only door rubber inner liner ( magnetic) suitable for watercooler Capacity 150 ltrs for fixing against defective parts of Water cooler taking down under item No 23 here in before complete all as specified and as directed.\n 1 Each
16 16 S&F in repairs fancy type with push taps, chromium plated cast copper alloy 15mm bore & screwed for iron pipe and fixed, complete all as specified and as directed.\n 8 Each
17 17 S&F in repair steel Connection with brass unions at both ends with brass nuts of length 600mm long etc, suitable for fixing to 15 mm dia GI Pipe, complete all as specified and as directed.\n 24 Each
18 18 S&F in repairs PVC ball valve 15mm dia high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed suitable for water coolers, complete all as specified and as directed.\n 2 Each
19 19 S&F in repairs PVC high density plastic ball screwed for iron pipe and fixed suiatble to fix to 15mm PVC float valve, complete all as specified and as directed.\n 2 Each
20 20 S&F in repair PVC drain out pipe 25 mm dia bore as per existing by providing necessary GI Clamps nuts bolts etc. complete all as specified and as directed.\n 2 RM
21 21 M&L for replacement of base plate of water cooler of any cacapcity, made out of 2mm thick MS sheet and painting with two coats of enamel paint over one coatt of red oxide primer, complete all as specified and as directed.\n 1 Each
22 22 Taking down Defective Deep Freezer of 310 LITRE Capacity, Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /reinstallation after taking out defective parts/burnt Compressor Selected Unit & providing new Compressor of same Capacity from authorised dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas including Re-connection of All Electrical Connections, complete all as specified and directed.\nNote:- Change of spare parts shall be measured separately under relevant item here-in-after as supply only rates fixing charges for spare parts shall deemed to be inclusive in the quoted rates. Old replaced material has to be shown to Engr-in-Charge measured under sch of credit. 1 EACH JOB
23 23 Taking down Defective Water Cooler 40/80/120/150 LITRE Capacity, Transportation from MES Store Yard/Site to Workshop and back including re-fixing /reinstalling, Testing, connecting the same after replacement of defective parts/burnt out Compressor Selected Unit with new Compressor from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas, complete all as specified and as directed. \nNote:- Change of spare parts shall be measured separately under relevant item here-in-after as supply only rates fixing charges for spare parts shall deemed to be inclusive in the quoted rates. Old replaced material has to be shown to Engr-in-Charge measured under sch of credit. 1 EACH JOB
24 24 M&L for rewinding fan fotor of existing water cooler 40/80 and 120/150 LITRE capacity with suitable size copper wire including taking out unserviceable rewinding from fan motor, complete all as specified and as directed. 1 EACH JOB
25 25 Supply only Starting Relay for Water Cooler 40/80/120/150 LITRE Capacity for fixing against defective parts of Water cooler taking down under item No 23 here in before complete all as specified and as directed.\n\n 4 EACH
26 26 M&L for repairs and overhauling of Voltage Stabilizer of 1.0 KVA, 2.0 KVA/3.0 KVA & 5 KVA Capacity of any MAKE including replacement of Relay, Capacitors, Switches, Voltmeters and Testing, etc., complete all as specified and as directed. 16 EACH JOB
27 27 Taking down wall mounted Geyser of Capacity 25/35/50 ltrs by disconnection electric supply, water connections and in single/Married/OTM Accns messes, billets, cafeteria etc,and refixing after repair/maint work and testing complete all as specified and as directed. 35 EACH
28 28 Dismantling the Geyser descaling of silt deposited /Cleaning of inner tank of geyser 25 to 35 Ltrs capacity including washing with clean water, checking the spare parts, re assembling and testing complete all as specified and as directed.\nNote:- Change of spare parts shall be measured separately under relevant item here-in-after as supply only rates fixing charges for spare parts shall deemed to be inclusive in the quoted rates. Old replaced material has to be shown to Engr-in-Charge measured under sch of credit. 25 EACH
29 29 All as per item No 28 here-in-before but of capacity 50 Ltrs Geyser, complete all as specified and as directed. 10 EACH
30 30 M&L for repairs to inner copper/steel tank of geyser 50/35/25 Ltrs capacity for leaks by pressure test, including gas welding for making leak proof, testing complete all as specified and as directed. 2 EACH
31 31 Supply only Apparatus plate for Geyser of 25/35/50 Ltrs capacity for fixing against defective parts of Geyser taking down under item No 28 & 29 here in before complete all as specified and as directed.\n 5 EACH
32 32 Supply only Bimetal Thermostat for Geyser of 25/35/50 Ltrs capacity for fixing against defective parts of Geyser taking down under item No 28 & 29 here in before complete all as specified and as directed.\n 20 EACH
33 33 Supply only Auto cut thermostat for Geyser of 25/35/50 Ltrs capacity for fixing against defective parts of Geyser taking down under item No 28 & 29 here in before complete all as specified and as directed.\n 20 EACH
34 34 Supply only Heating element screw/push/triangular type any shape for 1.5 KW capacity for Geyser of 25/35/50 Ltrs capacity for fixing against defective parts of Geyser taking down under item No 28 & 29 here in before complete all as specified and as directed.\n 30 EACH
35 35 Supply only Heating element 2.0 Kilo watts with round/triangle base, push and clamp fixing type for Geyser of 25/35/50 Ltrs capacity for fixing against defective parts of Geyser taking down under item No 28 & 29 here in before complete all as specified and as directed.\n 10 EACH
36 36 Supply only Indicating lamp of any shape/size for Geyser of 25/35/50 Ltrs capacity for fixing against defective parts of Geyser taking down under item No 28 & 29 here in before complete all as specified and as directed.\n 15 EACH
37 37 Supply only PVC Hot and cold pipe thread reinforced with washer and chromium plated check nut 18 " long for Geyser of 25/35/50 Ltrs capacity for fixing against defective parts of Geyser taking down under item No 28 & 29 here in before complete all as specified and as directed.\n 10 EACH
38 38 Supply only Steel water tank suitable for 25 Ltrs capacity for fixing against defective parts of Geyser taking down under item No 28 & 29 here in before complete all as specified and as directed.\n 1 EACH
39 39 Supply only Copper water tank suitable for 35 Ltrs capacity for fixing against defective parts of Geyser taking down under item No 28 & 29 here in before complete all as specified and as directed.\n 1 EACH
40 40 Supply only Copper water tank suitable for 50 Ltrs capacity for fixing against defective parts of Geyser taking down under item No 28 & 29 here in before complete all as specified and as directed.\n 1 EACH
41 41 Supply only Air pressure release safety valve 15 mm dia suitable for Geyser of 25/35/50 Ltrs capacity for fixing against defective parts of Geyser taking down under item No 28 & 29 here in before complete all as specified and as directed.\n 15 EACH
42 42 Supply and fix in replacement of non-return valve made out of brass vertical type 15 mm dia with new one ISI marked complete all as specified and directed 10 Each Set
43 43 Supply and fix in replacement of GI union, 15 mm dia medium grade, ISI marked complete all as specified and directed 8 Each
44 44 Supply and fix in replacement of GI nipple, 15 mm dia, 50 mm long medium grade ISI marked complete all as specified and directed. 8 Each
45 45 Supply and fix in replacement of GI elbow 15 mm dia medium grade ISI marked complete all as specified and directed 8 Each
46 46 Supply and fix in replaceent of GI socket 15 mm dia, medium grade ISI marked complete all as specified and directed 8 Each
47 47 Supply and fix for repairs to apparatus plate assembly by means of welding/brazing as required to stop leakage etc for 25/50 lit capacity geyseres of existing make at site and testing complete all as specified and as directed. 10 Each
48 48 S&F in repairs stop valves 15mm dia, cast copper alloy chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, but fancy type, chromium plated with long shank and cup, complete all as specified and as directed.\n 10 EACH
49 49 Supply and fix MS nut bolts 4 Nos, 10mm dia 150 mm long grouting to brick wall providing PCC (1:2:4) type B-1 for fixing of geyser including taking down old unserviceable bolts and making good to disturbed surfaces complete all as specified and as directed. Supply only Thrust bearing housing for fixing against defective parts of submersible pump set 15/20 HP taking down under item No 24 here in before complete all as specified and as directed.\n 15 EACH JOB
50 50 Supply and fix PVC insulated 3 core multistranded copper conductor cable of size 2.5 Sqmm a color code (Red for Phase, Black for Neutral and green for earth conductor) including taking down the old unserviceable cable complete all as specified and as directed. 100 RM
51 51 Supply and laying/fixing Galvanized iron pipe medium grade 15 mm bore with all fittings/ fixtures like Tee, Elbow, Bend, union socket etc fixed to wall/ceiling/floor with clamps including taking down the old unserviceable pipe complete all as specified and as directed. 60 RM
52 52 Supply and fixing in repairs of 3 pin plug top AC-230 Volts 15 Amp, complete all as specified and as directed.\n 15 Each
53 53 M&L for Servicing of Aqua Guard, RO any type/make including replacement of micron cartridge,ultra filter, pre- filter,RO membrane with cleaning of inlet outlet pipe upto water cooler including repair of raw water feed pump and repair of internal wiring refixing in same location and re-writing of MES No complete all as specified and as directed. 3 Each Job
54 54 M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor FRLS cable (with colour code), drawn through and including PVC casing capping of suitable size wirh ISI marked medium grade including all accessories of casing caping as approved by EIC, including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly complete all as specified and as directed. \nNotes:- (i) Three run of single core 6.0 sqmm cable & one run of PVC casing capping shall be measured as one unit length.\n 200 RM
55 55 Taking down old unserviceable sub main wiring of any size and any description complete all as specified and as directed. 200 RM
56 56 S & F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, including taking down old unserviceable ones, complete all as specified and as directed. \n 18 EACH
57 57 S&F in repairs MCB SPN 240 volts 40 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and as directed.\n 8 Each
58 58 S&F in repairs MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and as directed.\n\n 8 Each
59 59 Supply and fixing in repairs of voltage stabilizer for automatic operation, single phase, naturally air cooled designed for input voltage variation between 130Volt to 250 Volt with out put voltage stabilizer at 230 Volt with accuracy of (+-) 2.5%, capacity 5 KVA complete all as specified and as directed. 12 Each
60 60 Supply and filling Gas Charging with R-22 /R134a/R404/R-32 Gas of AC (Window/Spilt Type) 1.5/2.0 TR Capacity with required quantity of Refrigerant in the Unit including Checking of Leakage in the System, Brazing the Leakage Parts of Oil Gas Tubing as required, complete all as specified and as directed. 69 Kg
61 61 Taking down/up defective AC (Window/Split Type) 1.5/2.0 TR Capacity, Transportation to MES store yard/site to workshop and back including re-fixing /re-installing after servicing and repair including testing complete all as specified and as directed. \nNote:- charging of gas shall be measured separately under relevant item here-in-after. 12 Each Job
62 62 M&L for servicing of 1.5/2.0TR capacity window/split type AC disconnect from electric connection and open suction & dicharge pipe from outer unit , such as removing/ scrach dust with iron brush, cleaning condessor unit, compressor, cooling coil/cleaning of fan blade/cleaning of filter of inner unit etc,including (check thermostate, starting capacitior, running capacitor) with water & air blower, at the site and reinstall at the same place and connect all electrical connection complete all as specified and directed by Engr-in-charge. \nNotes:- (i) Charging of gas shall be measured separately under relevant item here-in-after as required to fill as per requirement/manufacturer instruction.\n 32 Each Job
63 63 M&L for rotary type compressor sealed Unit 1.5 ton capacity from authorised dealer including re-connection of electric connections, including removing old unserviceable compressor and functioning AC complete in all respect and testing, complete all as specified and as directed. 4 Each Job
64 64 All as per Item No. 63 here-in-before but AC (Window/Split Type) 2.0 TR Capacity, complete all as specified and as directed. 2 Each Job
65 65 M&L Fan Motor of AC (Window/Split Type) 1.5 TR Capacity of approved Make and required Size to suit existing AC including taking out the unserviceable fan motor from AC, complete all as specified and as directed. 9 Each
66 66 All as per Item No. 65 here-in-before but AC (Window/Split Type) 2.0 TR Capacity, complete all as specified and as directed. 4 Each
67 67 M&L Air Circular Blower Fan Motor of AC (Split Type) 1.5 TR Capacity (as per Sample/Site Requirement) including taking out unserviceable Air Circular Blower Fan Motor from AC, complete all as specified and as directed. 9 Each
68 68 All as per item No. 67 here-in-befofre but AC (split type) 2.0 ton capacity complete all as specified and as directed. 4 Each
69 69 M&L printed circuit board(PCB kit) for split type AC, 1.5 TR Capacity (as per Sample/ Site Requirement) including taking out unserviceable PCB including from AC, complete all as specified and as directed. 12 EACH
70 70 All as per item No. 69 here-in-befofre but AC (split type) 2.0 ton capacity complete all as specified and as directed. 4 EACH
71 71 M&L capacitor Running 36 mfd – 45 mfd of AC (Window/Split Type) 1.5/2.0 TR Capacity including taking out unserviceable Capacitor from AC, complete all as specified and as directed. 18 Each
72 72 M&L Capacitor Starting 80 mfd – 120 mfd of AC (Window/Split Type) 1.5/2.0 TR Capacity including taking out unserviceable Capacitor from AC, complete all as specified and as directed. 18 Each
73 73 M&L Fan Motor Capacitor 4 mfd of AC (Window/ Split Type) 1.5/2.0 TR Capacity including taking out unserviceable Fan Motor Capacitor from AC, complete all as specified and as directed. 18 Each
74 74 M&L Fan Motor Capacitor 6 mfd of AC (Window/ Split Type) 1.5/2.0 TR Capacity including taking out unserviceable Fan Motor Capacitor from AC, complete all as specified and as directed. 10 EACH
75 75 M&L Starting Relay of AC (Window/Split Type) 1.5/2.0 TR Capacity including taking out unserviceable Starting Relay from AC, complete all as specified and as directed. 10 EACH
76 76 M&L Thermostat Switch of AC (Window/Split Type) 1.5/2.0 TR Capacity including taking out unserviceable Thermostat Switch from AC, complete all as specified and as directed. 5 EACH
77 77 M&L Mild steel stand as per existing for testing AC Window type/Split type 1.5 to 2.0 TR capacity, grouting with Brick wall with Mild steel expandable bolts with steel rawl plug including making good walls in cement mortar (1:3) as required including dismantling old unserviceable mild steel stand for AC’s complete all as specified and as directed. 10 EACH JOB
78 78 Supply and fixing in repairs of copper capillary tube 5/8" as suitable size for repairing window/split type AC complete all as specified and as directed. 24 RM
79 79 Supply and fixing in repairs of copper capillary tube 1/2" as suitable size for repairing window/split type AC complete all as specified and as directed. 24 RM
80 80 Supply and fixing inrepairs of copper capillary tube 1/4" as suitable size for repairing window/split type AC complete all as specified and as directed. 24 RM
81 81 Supply and fixing sensor for all type AC (split/window) 1.5/2.0 ton capacity complete including taking out unserviceable sensor from AC, complete all as specified and as directed. 12 Each
82 82 Supply and fixing transformer for split type AC 1.5/2.0 ton capacity complete including taking out unserviceable transformer from AC, complete all as specified and as directed. 8 Each
83 83 Supply and fixing air filter for split/window type AC 1.5/2.0 ton capacity complete including taking out unserviceable air filter from AC, complete all as specified and as directed. 8 Each job
84 84 Supply and fixing swing blades for split/window type AC 1.5/2.0 ton capacity complete including taking out unserviceable swing blades from AC, complete all as specified and as directed.\nNote:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quoted amount. \n 8 Each job