Comletion Of Left Over Work For Provn Of Porta Cabin At 13 End Of Runway At Air Force Station Srinagar, GE (AF) SRINAGAR-Jammu And Kashmir

Military Engineer Services-MES has published Comletion Of Left Over Work For Provn Of Porta Cabin At 13 End Of Runway At Air Force Station Srinagar. Submission Date for this Tender is 05-10-2021. Civil Work Tenders in GE (AF) SRINAGAR Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

28473249
Corrigendum : Comletion Of Left Over Work For Provn Of Porta Cabin At 13 End Of Runway At Air Force Station Srinagar
Open Tender
Indian
Jammu And Kashmir
GE (AF) SRINAGAR
05-10-2021

Tender Details

Comletion Of Left Over Work For Provn Of Porta Cabin At 13 End Of Runway At Air Force Station Srinagar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Jul-2021 Date Date 30-07-2021
2 22-Jul-2021 Date 2 Date 06-08-2021
3 31-Jul-2021 Date 3 Date 13-08-2021
4 07-Aug-2021 Date 4 Date 27-08-2021
5 21-Aug-2021 date 5 Date 07-09-2021
6 31-Aug-2021 Date 6 Date 21-09-2021
7 15-Sep-2021 Date 7 Date 28-09-2021
8 21-Sep-2021 BOQ Corrigendum BOQ 28-09-2021
9 28-Sep-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 24000.0 /-
Tender Value
INR 12 Lakhs /-

BOQ Items

Name of Work: COMPLETION OF LEFT OVER WORK OF PORTA CABIN AT 13 END OF RUNWAY AT AIR FORCE STATION SRINAGAR.
Sl. No. Item Description Item Code / Make Qty Units
1 1 Sch 'A' Part I (Building Work)\n
2 1.01 Completion of Left over of prefabricated shelter single storey including foundation , earthwork PUF insulated panel walls, PUF insulated partition, PUF insulated ceiling, galvalume sheet roofing, steel columns, pedestals, trusses, etc alongwith sanitary annexe complete as per Drg No GEAF/WD-122/2015 Sh 1/2 to 3/3 all as specified and as shown on drawings and directed by Engineer in Charge\n 1 Each
3 1.02 [Note: (i)Datails of left over work & completed work done are attached as per Annexure 1(A) & 1(B). \n(ii) Contractor shall visit Bldg at site before quoting rate.\n(iii) Approx qty for left over work & completed work done of Bldg are given in Annexure 1(A) & 1(B). Which shall be varified before quoting lumpsum of Bldg.\n(iv) Rectification in Bldg if any required shall be responsibility of the contractor and the lumpsum quoted shall interlia include this provision and nothing extra shall be admissible.\n(v) Annexure '1(A) & 1(B) ' Showing list of balance work & completed work done are for quidance only. The Lumpsum quoted shall included for all the items required for compeletion of work all as specified and shown on drawing.
4 2 Sch 'A' Part II (Earthwork and excavation)\nNote: Prepriced at par with SSR 2010 Part II at Serial Page No 16 and contractor has to quote the estimated amount under Col 6\n 1 Lumpsum
5 3 Sch 'A' Part III Section A (Internal Electrification)\nNote: Prepriced at par with SSR 2010 Part II at Serial Page No 19 and contractor has to quote the estimated amount under Col 6\n 1 Lumpsum
6 4 Sch 'A' Part III Section B (Internal Electrification)\nNote: To be quoted by the contractor
7 4.01 MCB single pole neutral ISI marked conforming to `C' Series for incoming & outgoing connection of 6 to 32 Amp 240V 10KA breaking capacity complete all as specified and directed by Engineer-in-charge\n 6 Each
8 4.02 MCB single pole neutral ISI marked conforming to `C' Series for incoming & outgoing connection of 40 to 63 Amp 240V 10KA breaking capacity complete all as specified and directed by Engineer-in-charge\n 1 Each
9 4.03 Endura Flat Panel Ultra Sim (Edge-Lit) 1x36Watt LED, 6K edge-lit luminaire with 1x36W LED lamp including all its accessories suitable for armstrong/grid ceiling complete all as specified and directed by Engineer-in-Charge\nMake: Havells Cat Part No LHEWEBP7PL2W036 or equivalent in Philips/Surya\n\n 9 Each
10 4.04 `CRYPTON DD SERIES FP-L' street/bldg security light fitting with deep drawn housing suitble for single FP-L lamp 1 x 36 Watt HF(MS) with 1 x 36 Watt FPL lamp including suitble size of GI bracket, MS clamps, nuts and bolts complete all as specified and directed by Engr-in-Charge\nMake: Havells Cat Part No LHRC01136025 or equivalent in PHILIPS/BAJAJ\n 2 Each
11 4.05 Ceiling fan complete accessories 230 V single phase 1200mm sweep complete all as specified and directed by Engineer-in-Charge\n 4 Each
12 4.06 Exhaust fans AC, Single phase, 230/240 V of size 230mm sweep 1400 RPM with louvre and necessary fixing arrangement complete including making necessary hole in the wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-Charge\n 2 Each
13 5 Sch 'A' Part IV (Internal Water Supply)\nNote: Prepriced at par with SSR 2010 Part II at Serial Page No 21 and contractor has to quote the estimated amount under Col 6\n 1 Lumpsum
14 6 Sch 'A' Part V (Hot Water Supply)\nNote: To be quoted by the contractor
15 6.01 supply and installation water heater storage type, electric, 25 litrs capacity with and including hot and cold water PVC connection pipe complete all as specified and directed by Engineeer-in-Charge\n 2 Each
16 7 Sch 'A' Part VI (External Watersupply)\nNote: Prepriced at par with SSR 2010 Part II at Serial Page No 22 and contractor has to quote the estimated amount under Col 6 1 Lumpsum
17 8 Sch 'A' Part VII (External Electric Supply)\nNote: Prepriced at par with SSR 2010 Part II at Serial Page No 23 and contractor has to quote the estimated amount under Col 6 1 Lumpsum
18 9 Sch 'A' Part VIII (Sewage Disposal)\nNote: Prepriced at par with SSR 2010 Part II at Serial Page No 25 and contractor has to quote the estimated amount under Col 6 1 Lumpsum