Housing Urban and Rular Development Government Departments Closing in 0 days TDR #28451026

Supply , Installation , Testing And Commissioning Of 82 . 5Kva Diesel Gen . Set For Oxygen Generation Plant 250 Lpm ( Psa Plant ) In Sdh Zira District Ferozepur

Issued by Government Departments · Zira, Punjab
Tender Value
13 Lakhs
Estimated cost
Bid Submission
14 Jul 2021
0 days left
EMD
26100
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Zira → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply , Installation , Testing And Commissioning Of 82 . 5Kva Diesel Gen . Set For Oxygen Generation Plant 250 Lpm ( Psa Plant ) In Sdh Zira District Ferozepur

BOQ

Name of Work: Supply, Installation, Testing and Commissioning of 82.5KVA Diesel Gen. Set for Oxygen Generation Plant 250 LPM (PSA Plant) in SDH Zira District Ferozepur
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11ELECTRICAL SERVICES FOR DG SET:BI01010001010000000000000515BI0100001166
22XLPE INSULATED UN-ARMOURED CABLES (LOOSE):
33Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-\nMake- Polycab, Havells, RR Kabel, Gemscab, KEI, Grandly, Ultracab, universal's unistar, RallisonBI01010001010000000000000515BI0100001167
44Overall size 150sq.mm (3½ Core) Un-armoured (Loose)BI01010001010000000000000515BI0100001168200Metre
55SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:BI01010001010000000000000515BI0100001169
66Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½\" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:-
77Wiring light point10Each
88Wiring 6Amp. Plug control comprising wall socket point6Each
99Wiring 16/20Amp. power plug control point2Each
1010COPPER EARTHING (Upto 8 metre in Length):
1111Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
1212Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length)8Each
1313COPPER EARTHING STRIP (As Additional Length):
1414Fixing additional Length of earthing with\nCopper Tape (On Surface/Flushed) with\npetty material as required etc.:-
1515Additional Length 20mm x 3mm thick Copper Tape15Metre
1616ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure):
1717Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- Make- L&T, ABB, Schneider . Havells
1818On Load Change Over Switch Four Pole 250amp., 415volts (With Sheet Enclosure)1Each
1919DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
2020Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
2121Double Walled Corrugated HDPE Pipe 120/103.5mm (Outer/ Inner dia.)100Metre
2222Supply and Errection of Single Core Unsheathed Multistand FR 120 Sq mm. Copper conductor cable, Make: KEI/RR Cable/Havell's, Complete in all respect as desired by the Engineer-in-Charge of work.80Metre
2323Supply and erection of LED batton 20watt LED (including LED driver) with High quality extruded aluminium with efficiency of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ±3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting. Make:-CROMPTON LCTL-18-CDL Jaquar LGLZ01X020XC / HAVELLS LUSB20WLED865SPCSS8Each
2424Supply, Erection, Testing and Commissioning of Water Cooled Silent DG Set 82.5KVA/66KW with AMF Panel, Three Phase, 415Volts, 50Hz, 1500 RPM Silent (Sound Proof) Diesel Generator Set. It should be Water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard).\nENGINE: The Diesel engine developing suitable BHP for giving a power rating as per ISO 8528- Part-1 (With CPCB Norms Compliance) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements.
2525ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication.\nALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled
2626Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.\nACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.
2727AMF CONTROL PANEL: AMF control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site:- DG Set Make:- KOEL, GREAVES, CUMMINS with Controller PC1.1 , MAHINDRA and Make of Alternator - Stamford/Crompton/Kirloskar.\n \n1Each
2828Making of Cement concrete foundation of size 5600mm X 2300mm X 300mm high for DG Set 140/160/180/200/225/250KVA (Approx.) with 10cm below ground level and 20 cm above ground level. The foundation start with bedding of Base course of floor consisting of cement concrete 1:8:16. The top of the foundation covered with 4\" Reinforced cement concrete M-20 type concrete mixer slab vicrated by needle vibrator and finished with 12.5mm thick cement plaster in ratio 1:4. The MS angle frame structure Shed with angle iron / MS Channel & Fiber sheet completer in all respect as per site requirement and as desired by the Engineer in charge.1Each

AI Tender Summary

OUR REF NO 28451026
AUTHORITY Government Departments
TENDER VALUE 13 Lakhs
LAST DATE 14-07-2021
Authority
Authority Name Public Works Department
Work Description Supply , Installation , Testing And Commissioning Of 82 . 5Kva Diesel Gen . Set For Oxygen Generation Plant 250 Lpm ( Psa Plant ) In Sdh Zira District Ferozepur
Basic Detail
Tender No 82.5 KVA Diesel Gen. Set of OGP 250 LPM SDH Zira
Bidding Type Tender
Location
City Zira
State Punjab
Key Dates
Publish Date 09 Jul 2021
Submission Date 14 Jul 2021
Open Date 14 Jul 2021
Finance
Tender Value 13 Lakhs
Tender Fee 5000
EMD 26100
Exemption Not Available
Document List
BOQ_138555.xls
Tendernotice_1.pdf
SBDZira.pdf
C75FA624-9D64-4045-B836-F4377CE7656B.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 14, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_138555.xls

pdf

Tendernotice_1.pdf

pdf

SBDZira.pdf

html

C75FA624-9D64-4045-B836-F4377CE7656B.html