}

Improvement Of Water Supply By Replacement Of Old Monoblock Pump Sets Alongwith Other Allied Works At Motia Khan Small Pump House Under Ae ( Eandm ) -Ii, EEEANDMWSCN-Delhi

Delhi Jal Board has published Improvement Of Water Supply By Replacement Of Old Monoblock Pump Sets Alongwith Other Allied Works At Motia Khan Small Pump House Under Ae ( Eandm ) -Ii. Submission Date for this Tender is 14-07-2021. Coats and Jackets Tenders in EEEANDMWSCN Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

28450830
Improvement Of Water Supply By Replacement Of Old Monoblock Pump Sets Alongwith Other Allied Works At Motia Khan Small Pump House Under Ae ( Eandm ) -Ii
Tender
Indian
Delhi
Eeeandmwscn
14-07-2021

Tender Details

Improvement Of Water Supply By Replacement Of OldMonoblock Pump Sets Alongwith Other Allied Works AtMotia Khan Small Pump House Under Ae ( Eandm ) -Ii , replacement of old monoblock pump sets by carrying following works:- s/o monoblock pump sets suitable for clear water tefc 25 hp motor f class insulation three phase , 50 hz speed- 3000 rpm , ac supply having the discharge-26-14 lps and head 44-58 mtr working on 415+5% volts . the pump should be fitted with ci casing ci impeller shaft of c-40 having suction and delivery of size 100 x 80 mm . make:- kirloskar/crompton , dismantling of monoblock p/set by disconnecting electric connection , removing the existing damaged m . s . base frame from the foundation by cutting of nut & bolts with the help of gas cutter and man power etc . as required and old material shifted to the store as per direction of site in charge . , breaking of cc foundation with the help of pneumatic hammer i/c manual & heavy labour taking out the existing damaged foundation bolt etc . , making of new cc foundation with suitable ratio of gravels , sand and cement as per standard size suitable for above p/set i/c ms foundation bolts as required . , providing of ms base frame for mounting of 25 hp monoblock pump set complete as per site requirement . , fitting of m . s . base frame on c . c . foundation after proper alignment/level , fitting of p/set on the base frame with the help of necessary material as required . , installation of above pump sets on the ms base frame with proper alignment , taking all safety precautions arranging all tools & tackles etc . and connection the motor from panel to starter . , renovation of delivery line of size 100/80 mm by carrying following works:- dismantling of sluice valve and nrv from existing system with the help of gas cutter for cutting of nut & bolt and taken out from existing line with the help of heavy labour and old material shifted to the store as per direction of site in charge . , supply of m . s . black pipe 100mm dia c class heavy duty . make: jindal/tata , supply of m . s . black pipe 80mm dia c class heavy duty . make: jindal/tata , supply of 100mm dia flange thickness size 12mm as per site requirement . , supply of 80mm dia flange thickness size 12mm as per site requirement . , supply of ci double flanged spindle sluice valve pn 1 . 0 is 14846 ci body/wedge/bronze ring/ss 410 shaft construction and ss is 6603 gr 12 , cr12 of 100mm size make:-kirloskar/ivc/djb approved make . , supply of ci double flanged spindle sluice valve pn 1 . 0 is 14846 ci body/wedge/bronze ring/ss 410 shaft construction and ss is 6603 gr 12 , cr12 of 80mm size make:-kirloskar/ivc/djb approved make . , supply of ci swing type non return valve as per is 5312 pn 1 . 0 ci body , door/bronze to rubber rings/ss 410 hinge pin of 80 mm size . make:-kirloskar/ivc/djb approved make . , s/o pressure gauge of 100 mm dia having required range with accessories such as gi fitting bib cock etc . as required to complete the work . make:-feibig/h-guru/djb approved make . , s/o different size of nut & bolts of good quality . , s/o rubber insertion jointing sheet conforming is 638/79 with isi mark 3 mm thick make:- jyoti or any other make approved by djb , making and laying the complete line with the above material with the help of cutting , welding and grinding etc . as per site requirement . , painting the above job with two coats of anti corrosive paint after fittings all valves , bends etc in original position with complete civil works and testing/commissioning on full load i/c cartage etc . , repair/renovation of lt panel and other works by carrying out the following works: dismantling of all damaged switchgears , measurement instrument , indicating lights , relay , cleaning of dust , spider web , foreign particles etc . and removing of complete wiring and connection at site . , mccb 415 v , four pole high breaking capacity 50 ka 50 hz , 400 amp with spreader and handle - make l&t/siemens , mccb 415 v , three pole 3 phase high breaking capacity 50 ka 50 hz , 100 amp with spreader and handle . make l&t/siemens , mcb single pole 6 amp . make l&t/havells , s/o single core copper conductor pvc insulated , 1100 volts of size 95 sq . mm make:-finolex/havells , s/o copper tube terminal heavy duty thimbles of size 95 sq . mm . make:- dowells/djb approved , s/o led street light 60w , pressure die cast aluminum housing with heat resistant , toughened glass and ip66 protection . make:-cg/havells/bajaj , s/o ceiling fan 240 v 1200 mm sweep size . make:-crompton/havells/orient , overload relay 45-75 make: l&t/siemens , over load relay 4 . 5-7 . 5 make: l&t/siemens , digital amp . meter make: ae/l&t , digital volt meter . 0-500 v make: ae/l&t , motor protection relay . make: l&t /siemens , power contactor 220v 3 phase 70 amp . make l&t/siemens , power contactor 220v 3 phase 50 amp . make l&t/siemens , star delta timer on delay . make: l&t /siemens , indicating lights led type ryb and on/off . make: l&t / havells , current transformer 300/5 , 100/5 , 40/5 . make: ae/advance , on load changeover switch 200 amp . open execution type . make: l&t/havells , fitting of the above components in panel enclosure with terminal blocks , channels , ferrules , thimble , support insulator on bus bar , required hardwares complete in all respect . , painting of complete panel board as required at site . , testing and commissioning of panel , as per required parameters with relevant is , testing of the panel prior to switching on as follows: i continuity and earth testing ii meggering of all equipments for phase to phase , neutral to body , neutral to earth and phase to earth iii checking for all tightness of nut and bolts iv alignments of doors etc . interlocking tests . all functional tests

Key Value

Document Fees
INR 500 /-
EMD
INR 16600.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail