| 1 | 1 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with SUB HEAD : 12 - ROOFING 685 the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) 2011 (Board with BIS certification marks). | BI01010001010000000000000515BI0100001113 | 220 | M2 |
|---|
| 2 | 2 | Providing and fixing anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to ISI:733 and IS:1285, anodized transparent or dyed to required shade according to IS:1868. (Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/paneling, C.P. brass/stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge (Glazing and paneling to be paid for separately) : For fixed portion - Powder coated aluminium (minimum thickness of powder coating 50 micron). | BI01010001010000000000000515BI0100001114 | 243 | kg |
|---|
| 3 | 3 | Providing and fixing anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to ISI:733 and IS:1285, anodized transparent or dyed to required shade according to IS:1868. (Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge (Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron) | BI01010001010000000000000515BI0100001115 | 154 | kg |
|---|
| 4 | 4 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade 1 Type II in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-Charge : Prelaminated particle board with decorative lamination on one side and balancing lamination on other side. | BI01010001010000000000000515BI0100001116 | 24 | M2 |
|---|
| 5 | 5 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-Charge . (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sq.m) | BI01010001010000000000000515BI0100001117 | 46 | M2 |
|---|
| 6 | 6 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315 , having brand logo embossed on the body/ plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors ,embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-Charge : With stainless steel cover plate minimum 1.25 mm thickness | BI01010001010000000000000515BI0100001118 | 2 | Each |
|---|
| 7 | 7 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality : 1.0 mm thick. | BI01010001010000000000000515BI0100001119 | 105 | meter |
|---|
| 8 | 8 | Providing and fixing in position concealed G.I section for wall panelling using board of required thickness fixed on the W profile (O.55mm thick) having a knurled web of 51.55mm and two flanges of 26 mm each each with lips of 10.55 mm ,placed@ 610 mm C/C in perimeter channel having one flange of 20 mm and another flange of 30mm with thickness of 0.55 mm and web of length 27 mm.Perimetre chanels is fixed on the floor and the ceiling with the nylon sleeves @610 mm C/C with fullythreaded self - tapping dry wall screws @ 200 mm C/C,all complete as per the drawing and diretion of Engineer- in charge, the joints of the boards are finished with specially formulated jointing compound and 48 mm white jointing tape to provide seamless finish : Plain Gypsum Plaster board conforming to IS: 2095 (Part-I) : 2011 (Board with BIS certification mark) 12.5 mm thick. | BI01010001010000000000000515BI0100001121 | 50 | M2 |
|---|
| 9 | 9 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer | BI01010001010000000000000515BI0100001122 | 318 | M2 |
|---|
| 10 | 10 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work | BI01010001010000000000000515BI0100001123 | 318 | M2 |
|---|
| 11 | 11 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3.00 sqm | BI01010001010000000000000515BI0100001124 | 3 | EACH |
|---|
| 12 | 12 | Dismantling aluminium/Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material within 50 metres lead as directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001125 | 60 | M2 |
|---|
| 13 | 13 | Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete : 50 mm | BI01010001010000000000000515BI0100001126 | 25 | EACH |
|---|
| 14 | 14 | Providing and fixing bright finished brass handles with screws etc. complete : 125 mm. | BI01010001010000000000000515BI0100001127 | 75 | EACH |
|---|
| 15 | 15 | Providing and fixing in position 19 mm thick BWP board for cup board almirah, tables,wall panelling etc including hardwares like hinges, nails and adhesive all complete as per instruction of EIC. | | 138 | M2 |
|---|
| 16 | 16 | Providing and fixing in position 6mm thick BWP grade ply including cost of all fittings and fixtures as instruction of EIC. | | 138 | M2 |
|---|
| 17 | 17 | Providing and fixing in position manually operated horizontally moving 100 mm wide venetian blinds of Mac, Sun, Vista levelor of approved quality etc. all complete as per instruction of Engineer - in - Charge. | | 26 | M2 |
|---|
| 18 | 18 | Providing and fixing 2 mm thick PVC tile flooring of size 900 mm x 150 mm of approved quality all complete as per instruction of Engineer - in - Charge. | | 120 | M2 |
|---|
| 19 | 19 | Circuit/sub-main wiring in PVC conduit : Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2x2.5 sq.mm + 1x2.5 sq.mm earth wire | | 100 | METER |
|---|
| 20 | 20 | Supplying and drawing following sizes of FR PVC insulated copper conductor single core cable in the existing surface/recessed steel / PVC conduit as required.3x1.5 sq.mm | | 200 | METER |
|---|
| 21 | 21 | Supplying and drawing following sizes of FR PVC insulated copper conductor single core cable in the existing surface/recessed steel / PVC conduit as required.3x2.5 sq.mm | | 240 | METER |
|---|
| 22 | 22 | Supplying and fixing piano/flush type switch/socket on the existing switch box/cover including connections etc. as required :5/6 amps switch | | 30 | EACH |
|---|
| 23 | 23 | Supplying and fixing piano/flush type switch/socket on the existing switch box/cover including connections etc. as required :15/16 amps switch | | 10 | EACH |
|---|
| 24 | 24 | Supplying and fixing piano/flush type switch/socket on the existing switch box/cover including connections etc. as required :6 pin 15/16 amps socket outlet | | 10 | EACH |
|---|
| 25 | 25 | Supply and fixing 5A to 32 A rating 240/415V ,10 kA \"C\"- curve miniature circuit breaker suitable for inductive load for following pole in the existing MCB DBs complete with connections , testing , commissioning etc. as required. Single pole | | 20 | nos. |
|---|
| 26 | 26 | Supply and fixing following rating four pole 415V , isolater in the existing MCB DBs complete with connections , testing , commissioning etc. as required. TPN -63A | | 2 | nos. |
|---|
| 27 | 27 | Supplying and fixing following ways surface / recess mounting vertical type 415 V TPN MCB MCB distribution board of sheet steel, dust protected ,duly powder painted inclusive of 200A tinned copper bus bar , common neutral link , earth bar , din bar for mounting MCBs (But without MCBs and incomer) as required (Note : Vertical type MCB , TPDB is normally used where 3 phase outlets are required. (But without MCB/RCCB/Isolator).8 way (4 + 24) double door | | 2 | nos. |
|---|
| 28 | 28 | Supply and fixing I/O box suitable for RJ 45 Cat-6 LAN cable Make : D-link or equivalent. | | 10 | nos. |
|---|
| 29 | 29 | Supply and fixing of RJ 45 Cat-6 LAN cable Make : D-link or equivalent. | | 15 | METER |
|---|
| 30 | 30 | Recessed mount slim panel LED light (2x2 ft) Standard make like Philips, Bajaj, Crompton etc. | | 30 | nos. |
|---|
| 31 | 31 | Total impact of GST for the purpose of CTC | BI01010001010000000000000515BI0100001373 | 1 | Nos. |
|---|