Project Description

Repairs And Maintenance Of Water Supply Distribution System Repairs And Maintenance Of Water Supply Distribution System At Afs Begumpet Under Ge ( Af ) Hakimpet

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Jul-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-Jul-2021

BOQ

NNAME OF WORK: REPAIRS AND MAINTENANCE OF WATER SUPPLY DISTRIBUTION SYSTEM AT AFS BEGUMPET UNDER GE (AF) KAHIMPET
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Dismantling the delivery pipe line of submersible pump set from water mains, lifting / taking out of GI column Pipes of 40 / 50 / 65 mm dia submersible cable / defective submersible pump set from bore well for servicing / repairs and lowering of repaired submersible pump set with GI column pipe 40/50mm dia submersible cable etc. complete in the bore well at various sites. The job is inclusive of M&L for disconnecting and jointing of submersible cable, disconnecting and reconnecting the delivery pipe line of submersible pump sets to water mains, testing for satisfactory running & continuous flow of water, complete all as specified & directed .1Job
22Repairs & Servicing of defective submersible pump of capacity upto 5 HP by dismantling the pump & replacinig unserviceable parts, assemble the pump properly, testing for satisfactory functioning complete all as specified and directed. Notes: (i) The rate are inclusive of trasporting the pump from bore well site to repair work shop & back to site. (ii) The rates are inclusive of turning / finishing work for fixing of parts properly. (iii) The replacement of unserviceable parts will be measured and paid separately under relevant Items. (iv) The rates are inclusive of testing of pump at borewell installation for satisfactory functioning / running.1Job
33Supplying of following unserviceable parts of submersible pump of capacity 2HP to 5HP capacity of the same make as existing:-
43.01CI stage Casing1Each
53.02G M Bush1Each
63.03SS Sleeve1Each
73.04Brass impeller1Each
83.05MS key for Impeller1Each
93.06SS studs with Nuts 10mm4Each
103.07CI intermediate Section1Each
113.08SS coupling bush common for Pump & Motor with key1Each
123.09High Tensile steel shaft1Each
133.1Strainer1Each
144Repairs & Servicing of defective submersible motor of capacity upto 5 HP by dismantling the motor & Replacing unserviceable parts, assemble the motor properly, testing for satisfactory functioning complete all as specified and directed. \nNotes: (i) The rate are inclusive of transporting the motor to repair work shop & back to site. (ii) The rates are inclusive of turning / finishing work for fixing of parts properly. (iii) The replacement of unserviceable parts will be measured and paid separately under relevant item. (iv) Rewinding of motor & servicing of Rotor if required will be measured & paid separately under relevant items. (v) The rates are inclusive of testing of motor at borewell installation for satisfactory functioning / running.1Job
155Replacement of the following unserviceable parts of submersible motor of capacity upto 5 HP capacity of the same make as existing:-
165.01Bearing bush Gunmetal1Each
175.02Bearing Bush SS with Rubber1Each
185.03Oil seal1Each
195.04Thrust plate / thrust bearing set.1Each
205.05Sand Guard1Each
215.06CI thrust Casing1Each
225.07SS studs with nuts 8 mm1Each
236Rewinding of Submersible motor by taking out burnt copper winding from stator, cleaning the casing & slots with wire brush & washing with water under pressure and dried, rewinding the motor using same gauge of insulated copper wire as existing, making the winding leak proof by applying varnish, drying etc., taking out the electrical terminals using suitable size of submersible flat cable upto 2.0 m, installing at its original position for 5HP motor, complete all as specified & directed .1Job
247Servicing of rotor of submersible motor inclusive of Turning / Polishing of rotor shaft of submersible motor of capacity upto 5 HP complete all as specified & directed .1Job
258Replacement of unserviceable GI socket heavy duty 40 / 50 MM dia. Suitable for GI column pipe complete all as specified & as directed .6Each
269Replacement of unserveceable Non Return Valve, Gun metal, 40 mm dia complete all as specified & directed . Make: Kirloskar/BIR/JOLOTO/TIGER.1Each
2710Replacement of unserveceable Non Return Valve, Gun metal, 50 mm dia complete all as specified & directed . Make: Kirloskar/BIR/JOLOTO/TIGER.1Each
2811S&F GI column pipe, heavy grade, 40 mm dia, with ISI mark, with heavy duty GI Socket at one end and other fittings as required for complete fixing all as specified & directed . Make:TATA/JINDAL30RM
2912S&F GI column pipe, heavy grade, 50 mm dia, with ISI mark, with heavy duty GI Socket at one end and other fittings as required for complete fixing all as specified & directed . Make:TATA/JINDAL30RM
3013Supply & fix, in repairs, Flat Cable PVC insulated & sheathed, multi-stranded copper conductor, water proof suitable for submersible pumpset, 3 core, 4 Sq mm complete all as specified & directed . Make: Finolex/RR KABEL/HPL/Indo-Asian.60RM
3114Supply & fix, in repairs, Flat Cable PVC insulated & sheathed, multi-stranded copper conductor, water proof suitable for submersible pumpset, 3 core, 6 Sq mm complete all as specified & directed . Make: Finolex/RR KABEL/HPL/Indo-Asian.30RM
3215Supply and fix in repair submersible pump starter DOL type suitable for 3 to 5 HP submersible pump, in sheet enclosure mounted on 2 Nos of 1.2m long, 40x40x5mm sixe angle iron stand duly grouted in PCC 1:4:8, 415V, 50\hz, 3 phase, conforms to IS/IEC 60947-4-1, with protections - overload, single phasing, phase reversal, phase imbalance Auto Restart Feature Vibration proof enclosure with IP54 protection class, Indications offered - ON/OFF, Voltage and Ampere all as specified and as directed by Engineer-in-Charge. Make : L&T /GE/Siements / HAvells/ Schneider.2Each
3316De-silting of accumulated soil from Borewell 150 MM dia & depth up to 100 Meter by using air compressor / special equipments for atleast 12 Hrs, complete all as specified & directed. Note: The rate shall be inclusive of hiring of Air compressor / special equipment, fuel required, tools & Accessories including transportation & skilled men power to execute the work.1Job
3417Dismantling the delivery & suction pipe line of monoblock / centrifugal pump set of any capacity from water mains, unscrewing foundation nuts, bolts and disconnecting electric supply, lifting / taking out defective pump set for repairs and re-installation of repaired pump set & connecting suction and delivery pipes & making electrical connections, tightening of foundation nuts & bolts after proper alignment. The Job is inclusive of testing for satisfactory running & continuous flow of water complete all as specified & as directed .4Job
3518Repairs & servicing of defective monoblock / centrifugal pump set of capacity from 5 HP to 7.5 HP by dismantling the pump & removing unserviceable parts, assemble the pump properly after replacement of unserviceable parts all as specified and as directed . NOTE:- (i) The rate quoted is deemed to be inclusive of transporting the pump from pump house site to work shop & back to site. (ii) The rate quoted is deemed to be inclusive of turning/finishing work for fixing of parts properly. (iii) The replacement of unserviceable parts will be paid & measured separately under relevant items. (iv) The rate quoted is deemed to be inclusive of oiling, greasing to bearing and bushes, providing suitable size of gland rope, replacement of foundation bolts, leak testing of pump at water supply installation for satisfactory functioning / running.2Job
3619Supply only new spare parts of monoblock / centrifugal pump set of capacity 5 to 7.5 HP capacity of the same make as existing:-
3719.01CI Gland coller2Each
3819.02SS Sleeve1Each
3919.03MS/CI Impeller1Each
4019.04MS key for Impeller2Each
4119.05SS studs with Nuts 10 mm4Each
4219.06SS coupling with rubber bushes common for Pump & Motor with Key, Nut bolts etc.1Each
4319.07High Tensile steel shaft1Each
4419.08SS bearings4Each
4519.09Metallic motor cooling fan blade .2Each
4620Repairs & servicing of defective monoblock / centrifugal pump set of capacity from 30 HP by dismantling the pump & removing unserviceable parts, assemble the pump properly after replacement of unserviceable parts all as specified and as directed . NOTE:- (i) The rate quoted is deemed to be inclusive of transporting the pump from pump house site to work shop & back to site. (ii) The rate quoted is deemed to be inclusive of turning/finishing work for fixing of parts properly. (iii) The replacement of unserviceable parts will be paid & measured separately under relevant items. (iv) The rate quoted is deemed to be inclusive of oiling, greasing to bearing and bushes, providing suitable size of gland rope, replacement of foundation bolts, leak testing of pump at water supply installation for satisfactory functioning / running.2Job
4721Supply only new parts of centrifugal pump set of capacity 30 HP capacity of the same make as existing:-
4821.01CI Gland coller2Each
4921.02SS Sleeve1Each
5021.03MS/CI Impeller1Each
5121.04MS key for Impeller1Each
5221.05SS studs with Nuts 10 mm2Each
5321.06SS coupling with rubber bushes common for Pump & Motor with Key, Nut bolts etc.1Each
5421.07High Tensile steel shaft1Each
5521.08SS bearings4Each
5621.09Metallic motor cooling fan blade .2Each
5722M&L for Rewinding of electrical motor by taking out burnt copper winding from stator, cleaning the casing & slots with wire brush & washing with water under pressure, cleaning with CTC, dried and rewinding the motor using same gauge of insulated copper wire as existing & making the winding leak proof by applying warnish, drying etc. and re-connecting at its original position of capacity of motor above 4 to 7.5 HP including testing of motor after installation for satisfactory functioning/running all as specified and directed .1Job
5823M&L for Rewinding of electrical motor by taking out burnt copper winding from stator, cleaning the casing & slots with wire brush & washing with water under pressure, cleaning with CTC, dried and rewinding the motor using same gauge of insulated copper wire as existing & making the winding leak proof by applying warnish, drying etc. and re-connecting at its original position of capacity of motor 30 HP including testing of motor after installation for satisfactory functioning/running all as specified and directed .2Job
5924M&L for Scraping of old paints from pump and motor of capacity upto 5 HP and applying two coats of synthetic enamel paint with sky blue colour and writing SM/MES No with white paint all as specified & directed .1Job
6025M&L for Scraping of old paints from pump and motor of capacity above 5 HP and upto 7.5 HP and applying two coats of synthetic enamel paint with sky blue colour and writing SM/MES No with white paint all as specified & directed .2Job
6126M&L for Scraping of old paints from pump and motor of capacity 30 HP and applying two coats of synthetic enamel paint with sky blue colour and writing SM/MES No with white paint all as specified & directed .2Job
6227M&L for Scraping of old paint from out side of vertical type pressure filter of 2600 mm diameter filtration plant and applying two coats of synthetic enamel paint of colour as directed and writing SM / MES No. with white paint all as specified & directed .1Job
6328M&L for Scraping of old paints from sluice valves, NRVs of sizes 100mm to 200 mm dia and applying two coats of synthetic enamel paint as per colour coding complete all as specified & as directed .12Job
6429S&F CI NRV with by pass arrangement of size 80mm dia flanged type, including replacement of gasket, nut, bolts, washers etc. and taking down existing unserviceable NRV, complete all as specified & directed . Make: Kirloskar/BIR/SIR.1Each
6530S&F CI NRV with by pass arrangement of size 100mm dia flanged type, including replacement of gasket, nut, bolts, washers etc. and taking down existing unsrviceable NRV, complete all as specified & directed . Make: Kirloskar/BIR/SIR.1Each
6631M&L for Scraping of old paints from suction and delivery pipes at pump house / Swimming pool premises of sizes 50 to 80mm dia and applying two coats of synthetic enamel paint of approved colour following color coding of suction and delivery pipes and marking direction of flow with white colour paint complete all as specified and directed .60Per RM
6732M&L for Scraping of old paints from suction and delivery pipes near by pump house/ Swimming pool premises of sizes 100 to 200 mm dia and applying two coats of approved colour following color coding of suction and delivery pipes and marking direction of flow with white colour paint complete all as specified and directed .60Per RM
6833Replacement of following UNSV spares for fully Auto-matic star delta starter of capacity upto 30 HP and testing all as specified and directed . Make: L&T / BCH / ABB / GE /Siemens or of make as existing.
6933.01Standard operating coils from 110 Volts to 440Volts.2Each
7033.02Spare kit with combination coil from 110V to 440V.1Each
7133.03Thermal timer with combination coil.1Each
7233.04Single phase preventor with timer. Make:L&T, model-SDz52Each
7333.05Single phase preventor relay. Make:L&T, model-Sz5 .2Each
7433.06Motor protection circuit breaker with short circuit & overload protection 5.0HP motor with suitable thermal release range in suitable enclosure. Make L&T, type-MOG-H1.1Each
7533.07Motor protection circuit breaker with short circuit & overload protection 7.5HP motor with suitable thermal release range in suitable enclosure. Make L&T, type-MOG-H11Each
7633.08Motor protection circuit breaker with short circuit & overload protection 30HP motor with suitable thermal release range in suitable enclosure. Make L&T, type-MOG-H11Each
7734Taking down existing MCCB from the Pump house panel board and S&F MCCB, 3 pole, 415 volts, 63 Amps with each breaking capacity 25 KA suitable for existing panel board complete all as specified aand as directed by Engineer-in-Charge.2Each
7835Taking down existing MCCB from the Pump house panel board and S&F MCCB, 3 pole, 415 volts, 100 Amps with each breaking capacity 35 KA suitable for existing panel board complete all as specified aand as directed by Engineer-in-Charge.2Each
7936Taking down unserviceable DOL starter of capacity upto 5.0 HP and supply and fix DOL starter suitable for pump set of capacity upto 7.5 HP all as specified and as directed by Engineer-in-Charge.2Each
8037Taking down/Dismantling the existing unserviceable spares, supply and fix the folllowing spares suitable for submersible/ cenrifugal/ monoblock pump set panel of various capacity .
8137.01Automatic Star Delta starter with Dry run trip, Single phasing and Phase reversel protection, CT coils and relays suitable for 5 to 7.5 HP capacity.\nMake - Havells /L&T/Crompton Greaves2Each
8237.02Automatic Star Delta starter with Dry run trip, Single phasing and Phase reversel protection, CT coils and relays suitable for 30 HP capacity.\nMake - Havells /L&T/Crompton Greaves1Each
8338Taking down existing unsv electrical meters, S&F VAF meter suitable for three phase all as specified and as directed by Engineer-in-Charge. Make:Conserve /AE/L&T.1Each
8439Taking down existing unsv Ammeter and supply and fix new Ammeter 0- 200 Amps range all as specified and as directed by Engineer-in-Charge. Make:Conserve /AE/L&T.1Each
8540Repair & maintenance to existing earth pit chamber by cleaning and removing foreign material from pit chamber, replacing broken RCC cover slab specified in plate No.3 of SSR part-I and inclusive of privision of salt solution not less than 5 kgs salt for one earth pit chamber to obtain required earth resistance value complete all as specified and as directed.6Each
8641Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft / loose dense soil, including removal of Bushes, grass, weeds, shrubs alongwith roots etc. and cleaning of all the area surrounded Pump house, UG Sump & OH Tank, valve chambers, treating the area by spraying anti vegetarian growth chemicals, including taking away all the waste from site and burning all as directed.1500Sqm
8742Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out in the following type of soil for laying pipes, complete all as specified and directed.
8842.01Soft / loose soil221.4Cum
8942.02Hard / dense soil118.8Cum
9043Returning, filling in soils, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.306.2Cum
9144Removal of excavated material to a distance not exceeding 50 m away from starting point and depositing where directed at a level not exceeding 1.5 m above starting point, complete all as specified and directed.34Cum
9245Material and labour for cutting road/hard standing not exceeding 0.60 m wide and not exceeding 0.25 m deep for laying and taking out water pipe line including making good the disturbed portion as per existing earlier, complete all as specified and directed.10Sqm
9346Taking up or down steel tubing and connections, including cleaning for re-fixing complete all as specified and as directed for the following sizes:-
9446.0115 mm dia GI tubing144RM
9546.0220 mm dia GI tubing230.4RM
9646.0325 mm dia GI tubing288RM
9746.0440 mm dia GI tubing192RM
9846.0550 mm dia GI tubing250RM
9946.0680 mm dia GI tubing50RM
10047Refixing old steel tubing and connections in new or old position (walls, ceiling. Floor, trenches etc.) including cleaning or rerunning the old screw thread as required and providing required connecting materials complete all as specified and directed for the following sizes:-
10147.0115 mm dia GI tubing84RM
10247.0220 mm dia GI tubing170.4RM
10347.0325 mm dia GI tubing168RM
10447.0440 mm dia GI tubing92RM
10547.0550 mm dia GI tubing50RM
10647.0680 mm dia GI tubing6RM
10748Supply and laying GI tubing medium grade ISI marked with all fittings, laid in trenches complete all as specified and as directed for the following sizes :- \nMake:TATA / JINDAL / PRAKASH.
10848.0115 mm dia GI tubing60RM
10948.0220 mm dia GI tubing60RM
11048.0325 mm dia GI tubing120RM
11148.0440 mm dia GI tubing100RM
11248.0550 mm dia GI tubing200RM
11348.0680 mm dia GI tubing44RM
11449Supply and laying GI tubing medium grade ISI marked with all fittings fixed complete to walls and ceiling or laid in floors incl. making good of disturbed surfaces complete all as specified and directed for the following sizes :- \nMake:TATA / JINDAL / PRAKASH.
11549.0115 mm dia GI tubing60RM
11649.0220 mm dia GI tubing72RM
11749.0325 mm dia GI tubing60RM
11850Supply and fix in repairs PVC float valve, working on high pressure, heavy duty with polythene float and iron rod with fly nuts complete screwed for GI pipe all as specified and directed for the following sizes including taking down old unserviceable float valve :- Make: Prayag / Shakthi / Dripless fancel (India)/Kirti.
11950.0115 mm dia bore pipe40Each
12050.0220 mm dia bore pipe90Each
12150.0325 mm dia bore pipe35Each
12251Supply & fix in repairs Gun metal globe/gate valve ISI marked high pressure with iron wheel head screwed both ends for iron pipe line and fixed properly of following sizes including taking out unserviceable gun metal gate valve:- Make: Zoloto / Leader / Tiger / Cresent.
12351.0115 mm dia bore12Each
12451.0220 mm dia bore12Each
12551.0325 mm dia bore12Each
12651.0440 mm dia bore6Each
12751.0550 mm dia bore6Each
12852Taking up cast iron water mains (including all fittings), with spigot and socketed ends and lead joints including burning out lead joints and recovering lead complete all as specified and as directed for the following sizes of pipes :-\nNote : Necessary Excavation and earth work will be measured and paid separately.
12952.0180 mm dia bore cast iron pipe165RM
13052.02100 mm dia bore cast iron pipe165RM
13152.03150 mm dia bore cast iron pipe27.5RM
13252.04200 mm dia bore cast iron pipe11RM
13353Re-laying the Cast pipes with spigot, socketed ends in any length laid in trenches complete all as specified and directed for the following sizes (CI pipe taken up vide relevant item in schedule):-
13453.0180 mm dia bore pipe142RM
13553.02100 mm dia bore pipe132RM
13653.03150 mm dia bore pipe5.5RM
13753.04200 mm dia bore pipe5.5RM
13854Supply and laying of DI pipe spigot and socket ends class 'K-7'suitable in replacement of CI pipes for tyton joint or any length properly laid in trenches all as specified and directed by Engr-In-Charge of following sizes:- (Make - Srikalahsti/Electrosteel/Kesoram/TISCO.\nNote:- Lead joint and Tyton jont will be measured and paid separatelly under respective items of sch.
13954.0180 mm dia bore pipe23RM
14054.02100 mm dia bore pipe33RM
14154.03150 mm dia bore pipe22RM
14254.04200 mm dia bore pipe5.5RM
14355Supply and fix, in repairs, CI specials such as bends (any type, radius and angle) Tapers any type, (straight, bend, increasing, decreasing or double sockets etc.) tee pieces, single branch, Y junction, double branch cross (all sockets or socket and spigot or all flanged or flanged and other socket or spigot) collars, caps and plugs etc .as per IS complete all as specified and directed upto 150 mm dia.500Kg
14456Supply and fix, in repairs, CI specials such as bends (any type, radius and angle) Tapers any type, (straight, bend, increasing, decreasing or double sockets etc.) tee pieces, single branch, Y junction, double branch cross (all sockets or socket and spigot or all flanged or flanged and other socket or spigot) collars, caps and plugs etc .as per IS complete all as specified and directed above 150 mm and upto 200mm dia.150Kg
14557Supply and fix, in repairs, CI specials such as bends (any type, radius and angle) Tapers any type, (straight, bend, increasing, decreasing or double sockets etc.) tee pieces, single branch, Y junction, double branch cross (all sockets or socket and spigot or all flanged or flanged and other socket or spigot) collars, caps and plugs etc .as per IS complete all as specified and directed upto 150mm dia.150Kg
14658Supply and fix, in repairs, CI specials such as bends (any type, radius and angle) Tapers any type, (straight, bend, increasing, decreasing or double sockets etc.) tee pieces, single branch, Y junction, double branch cross (all sockets or socket and spigot or all flanged or flanged and other socket or spigot) collars, caps and plugs etc .as per IS complete all as specified and directed above 150 mm and upto 200mm dia.100Kg
14759Opening and repacking stuffing box of sluice valve spindle including taking apart and reassembling including draining out the chamber as required.
14859.01(a) 80 mm dia bore10Each
14959.02(b) 100 mm dia bore12Each
15059.03(c ) 150 mm dia bore6Each
15159.04(d) 200 mm dia bore4Each
15260Draining out the valve chamber, taking out sluice valve, transporting to the workshop, refacing, regrinding to make it leak proof, bringing back, refixing including providing rubber insertion sheet, gland packing of suitable sizes, replacing of nuts, bolts and washers etc. to make the sluice valve leak proof and free operational all as specified and as directed for the following sizes :-\nNote 1 : Spindle and check nut will be measured and paid separately.\nNote 2 : Rate of rubber insertion sheet, nut, bolts, washers etc will deemed to be included in the item.
15360.01(a) 80 mm dia bore4Each
15460.02(b) 100 mm dia bore4Each
15560.03(c ) 150 mm dia bore2Each
15660.04(d) 200 mm dia bore2Each
15761Supply and fix CI sluice valve confirming to IS-14846 with iron wheel head, rating PN 1.6, Steel spindle, bolts and nuts, rubber or fiber board gaskets, including taking out old unserviceable CI Sluice valve from existing position by opening the nuts, bolts, jointing rings etc., complete all as specified and directed by for the following sizes:-\nMake: SIR / Kirloskar / BIR / Durga.
15861.0180 mm dia bore2Each
15961.02100 mm dia bore2Each
16061.03150 mm dia bore2Each
16161.04200 mm dia bore1Each
16262M&L Rubber gasket Joint (Tyton Joint) suitable for DI/CI pipe of following sizes all as specified and directed.
16362.01150mm dia pipe10Each
16462.02100mm dia pipe15Each
16562.0380mm dia pipe10Each
16663Material and labour for caulking in its position to the existing run lead joint complete to make it leak proof including providing required quantity of lead wool complete all as specified and as directed for the following sizes:-
16763.01(a) 80 mm dia bore12Each
16863.02(b) 100 mm dia bore12Each
16963.03(c ) 150 mm dia bore10Each
17063.04(d) 200 mm dia bore.8Each
17164Material and labour for run lead joints complete including jointing material such as spun yarn complete all as specified and directed for the following sizes:-
17264.0180 mm dia bore pipe24Each
17364.02100 mm dia bore pipe24Each
17464.03150 mm dia bore pipe6Each
17564.04200 mm dia bore pipe8Each
17665Supply and fix CI foot valve, flanged type of size 100 mm dia bore, PN 0.2, Confirming to IS-4038, made of cast iron, heavy duty with bolts, nuts, rubber / leather washer complete including taking out the unserviceable foot valve from the existing position by opening the nuts, bolts, jointing rings etc., complete all as specified and directed.2Each
17766Cutting of DI/CI/GI pipes in position for insertion of new Tees, branches, Tail piece and sluice valve etc complete all as specified and as directed.
17866.0180 mm dia bore pipe4Each
17966.02100 mm dia bore pipe4Each
18066.03150 mm dia bore pipe3Each
18166.04200 mm dia bore pipe2Each
18267Construction of valve chamber having inner dimension 1000 x 1000 x 1000 mm (suitable for 80mm to 200mm sluice valves & reflux valves) with PCC 1:4:8 type D2 for foundation, brick work wall in cement mortar (1:4), PCC 1:2:4 type B1 for coping, rendering plaster in CM 1:4, 15 mm thick including provision of MS Sheet top cover 3mm thick with welding of MS angle iron of size 25mm x 25mm x 4 mm at edges and in diagonal and angle iron base frame of 50 x 50 x 6 mm, painting with two coats of synthetic enamel paint over a coat of red oxide primer on iron surfaces, lime wash on internal and external cement surfaces and locking arrangements including demolition of the existing chamber, necessary excavation and earth work complete all as specified and as directed.2Job
18368Construction of valve chamber having inner dimension 750 x 750 x 750 mm (suitable for gate valve upto 50mm) with PCC 1:4:8 type D2 for foundation, brick work wall in cement mortar (1:4), PCC 1:2:4 type B1 for coping, rendering plaster in CM 1:4, 15 mm thick including provision of MS Sheet top cover 3 mm thick with brazing of MS flat of size 25 mm x 4 mm at edges and in diagonal and angle iron base frame of 40 x 40 x 5 mm, painting with two coat of synthetic enamel paint over a coat of red oxide primer on iron surfaces, lime wash on internal and external cement surfaces and locking arrangements including demolition of the existing chamber, necessary excavation earth work complete all as specified.4Job
18469Construction of valve chamber having inner dimension 600 x 600 x 600 mm (suitable for gate valve upto 50mm) with PCC 1:4:8 type D2 for foundation, brick work wall in cement mortar (1:4), PCC 1:2:4 type B1 for coping, rendering plaster in CM 1:4, 15 mm thick including provision of MS Sheet top cover 3 mm thick with brazing of MS flat of size 25 mm x 4 mm at edges and in diagonal and angle iron base frame of 40 x 40 x 5 mm, painting with two coat of synthetic enamel paint over a coat of red oxide primer on iron surfaces, lime wash on internal and external cement surfaces and locking arrangements including demolition of the existing chamber, necessary excavation earth work complete all as specified.4Job
18570M&L for GI pipe medium grade 100 mm dia with all connected fittings complete such as bend, elbow, socket, flange etc for suction pipe including taking down existging corroded suction pipes complete all as specified and directed. Make:TATA/JINDAL/PRAKASH.12RM
18671M&L for providing PCC 1:4:8, type D-2 using 40mm stone aggregate in the base of path complete all as directed.10Cum
18772M&L for providing PCC 1:3:6, type C-1 mix using 20mm stone aggregate in path complete all as directed.5Cum
18873S&F in repairs for Bib taps PTMT of size 15 mm dia bore , screwed down to iron pipe or for brass ferrule and fixed including taking down existing bib tap of any description complete all as specified and directed. Make:Prayag/Polytuf of R.S. Ind. / Gokul Plast.50Each
18974S&F in repairs, 15mm dia PTMT stop valve, screwed down, high pressure, with PVC handle, screwed both ends for iron pipe or for unions and fixed including taking down existing stop valve of any description complete all as specified and directed. Make: Prayag/Polytuf of R.S. Industries /Gokul Plast40Each
19075All as per item No 74 here-in-before but of size 20mm.10Each
19176Lifting RCC covers / slabs / PVC cover of RCC/ PVC over head water service tank and carefully taking out float valve, setting aside, removing all dirt and dust, cleaning internal portion of tanks including mouths of circulating inlet/outlet pipes and over flow pipes etc., with caustic soda solution / bleaching powder and completely removing the dirt, debris etc, , writing lettering (Such as tank capacity, cleaned on, Due on, month and year) with white paint over a black painted surface on external side of the tank with letters of 4 cm height, refixing the float valve by providing suitabale check nuts, washers etc., and placing of RCC / PVC covers back in position and ensuring over flow and leakage and repair if required and testing, complete all as specified and directed for the following capacity of tanks:- \nNotes:- (i) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scale and dust, the same shall be reconnected after cleaning the OHT and the quoted rate is deemed to include for this provision. (ii) Replacement of float valve will be measured and paid seperately in relevant item of schedule.
19276.01Exceeding 250 Ltrs and not exceeding 500 ltrs.400Each
19376.02Exceeding 500 Ltrs and not exceeding 1000 ltrs.100Each
19476.03Exceeding 1000 Ltrs and not exceeding 2000 ltrs.15Each
19577Cleaning internal portion of stone masonary / RCC over head reservoirs including removing fine sand/silt deposited inside the over head reservoirs with the help of wire brushes and removing fungus formation from inside the tank, cleaning with bleaching powder, removing the waste as directed and applying caustic soda solution and applying one coat of lime wash internally including writing letters with white paint over a black paint on external side and marking direction of flow of water for inlet/outlet pipes of DI/CI/GI including painting/ writing of letters of (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank etc, complete all as specified and directed for the following capacity:-
19677.011,00,000 Glns capacity, with staging at a height of approx 16m.1Job
19777.0210,000 Glns capacity, with staging at a height of approx 12m2Job
19877.035,000 Glns capacity, with staging at a height of approx 7m1Job
19978Cleaning internal portion of under ground / semi under ground sump, removing the waste to a distance upto 100 m, applying caustic soda solution and one coat of lime wash to internal surfaces including writing direction of flow (a) Date of cleaning, (b) Due date (c) Capacity of sump etc. cleaning vegetation upto 5m sorrounding the sump complete all as specified and as directed for the following capacity:-\nNote:- The rates quoted shall be deemed to be inclusive of provision of mobile diesel pump set of suitable capacity by the contractor for removing the muddy water from the sump and for cleaning.
20078.0150,000 Glns capacity1Job
20178.0210,000 Glns capacity3Job
20279Cleaning of static water tank internal portion of under ground / semi under ground static water and removing the waste to a distance upto 100 m away applying caustic soda solution and one coat of lime wash to internal surfaces and one coat of synthetic enamel paint to the wire mesh on top of static water tank including cleaning/cutting bushes all around the static water tank to a distance upto 3 m distance complete all as specified and as directed for the following capacity:- \nNote:- The rates quoted shall be deemed to be inclusive of provision of mobile diesel pump set of suitable capacity by the contractor for removing the muddy water from the sump and for cleaning.
20379.01Upto 50,000 ltrs capacity static water tank. (NTS, Fire Section & Near Family Room)3Each
20479.02Above 50,000 ltrs and upto 1,00,000 ltrs capacity static water tank.5Each
20580Cleaning of swimming pool of capacity 6 lakh ltrs by removal of dirty water, sludge, organic and inorganic matter settled inside the pool tank, side walls inclusive of material and labour for cleaning/ washing of floor/wall tiles of swimming pool with suitable acid/chemical inclusive of one coat of synthetic enamel paint of tint as existing to the ladder / pipe lines /any other iron surfaces of swimming pool complete all as specified and directed. \nNote:- The rates quoted shall be deemed to be inclusive of provision of mobile diesel pump set of suitable capacity by the contractor for removing the muddy water from the swimming pool and for cleaning.1Job
20681Cleaning of suction(balancing) sump of swimming pool by removing dirty water, with mobile diesel pump set of suitable capacity, sludge and other particles including white washing on plastered surface and synthetic enamel painting to GI/CI pipe of tint as existing complete all as specified and directed.\nNote:- The rates quoted shall be deemed to be inclusive of provision of mobile diesel pump set of suitable capacity by the contractor for removing the muddy water from the sump and for cleaning.1Job
20782Materials and labour for taking out old, broken unserviceable MS sheet cover, frame etc. from top of the roof of under ground water sump with MS channel base square/circular type of size and shape as per site requirement including providing of new cover made out of 10 to 14 SWG MS sheet cover with 50cm x 50cm x 6mm angle iron base frame including painting with two coats of synthetic enamel black paint over a coat of red oxide primer complete with locking arrangements and locks and neccessary PCC works (as required at site) complete all as specified and directed .150Kg
20883M&L for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of following capacity, hoisted and fixed in position all as specified in SSR Part-I complete including dismantling unsv water tank complete all as specified and directed. Make : Sintex / AQUATECH / INFRA /Polycon
20983.01500 Ltrs capacity2Each
21083.021000 Ltrs capacity1Each
21183.032000 Ltrs capacity2Each
21284Supply and fix of polythene tank cover for cylindrical tank of capacity upto 500 Ltrs including removing the old one.30Each
21385Supply and fix of polythene tank cover for cylindrical tank of capacity above 500 Ltrs and upto 1000 Ltrs including removing the old one.10Each
21486Taking down conventional type water level indicator from the over head tank, replacement of unserviceable existing pullies, supply and fix spares for conventional type water level indicator such as suitable size of float, steel wire rope and plumb complete all as required at site for functioning of water level indicator all as specified and as directed by Engineer-in-charge.2Each
21587M&L for retro reflective sign boards including taking down the old boards all specified and as directed.60Sqft
21688Supply only water sanitising chemical, Calcium Hypochlorite granules with chlorine content above 65%, for water treatment to maintain chlorine dosage at 2 ppm for Pumphouse and Swimming pool. Make : M/S Royalseema alkalies or equivalent.450Kg
21789Servicing and maintanance of Vertical pressure filter 2600 mm diameter all as specified and as directed by the Engineer-in-charge including replacement only of filter media(which shall be measured and paid separetely).1Job
21890Supply only coarse sand suitable for pressure filtration plant of swimming pool.120Cft
21991Supply only Graded gravels 3mm-6mm, 6mm-12mm, 12mm-20mm, 40mm-63mm all as required for pressure filtration plant of swimming pool.\n120Cft
22092Servicing & maintenance of suction sweeper, replacement of Sweeping brush including rusted, worn out nut & bolts, greasing and oiling of wheel of Suction sweeper trolly including replacement of suitable size of rope of required length, Hose pipe with PVC float all as specified and directed by Engineer-in-Charge.1Job
22193Supply only the following items for maintenance of swimming pool filter plants and earthing pits at pump house / swimming pool premises:-
22293.01Soda ash50Kg
22393.02Crystal Alum50Kg
22493.03Blue powder suitable for swimming pool50Kg
22593.04Common salt for earth pits.200Kg
22694M&L earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground with top edge of the earth plate not less than 1.5 mtr below normal ground level, earth plate shall be connected to & including the galvanized iron strip 32 x 6 mm upto LT feeder pillar box or 7.5m which ever is less, connected to plate by welding and by using steel bolts, nuts, check nuts & washers, GI strip drawn only through suitable size of GI protecion pipe, including excavation, earth work, Charcoal & Salt, filling with soft/loomy/ black cotton soil/ bentonite clay mix, 30cm sorrounding GI plate after salt, charcoal all as specified, PCC chamber, RCC cover slab with 8mm dia clamp for lifting at centre, watering pipe 20mm bore med. grade, wire net, funnel etc. & testing on completion to achieve desired resistance of below 2 ohms, all as specified in plate No.3 of SSR Pt I. NOTE: a) GI Pipe for protection of earthing strip and (b) earth strip beyond 7.5m shall be measured and paid seperately under relevant items.7Each
22795Supply, lay/fix GI Protection pipe, 40 mm dia, medium grade. Make : Jindal/TATA.10RM
22896Supply and fix, 32x6mm earth strip as earth continuity conductor to equipment.30RM
22997Supply and replacement of strainers for pressure filter.100Each
23098Chemical analysis of borewell and external source water for all parameters for ascertaining water fitness (Potability and bacterial) for human consumption through Government or NABL approved laborotory with necessary collector vessels/ cans, complete all as specified and directed.12Job

AI Tender Summary

OUR REF NO 28442787
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 27-07-2021
Authority
Authority Name Military Engineer Services
Work Description Repairs And Maintenance Of Water Supply Distribution System Repairs And Maintenance Of Water Supply Distribution System At Afs Begumpet Under Ge ( Af ) Hakimpet
Basic Detail
Tender No 8298/E8
Bidding Type Tender
Location
City BEGUMPET
State Telangana
Key Dates
Publish Date 20 Jul 2021
Submission Date 27 Jul 2021
Open Date 29 Jul 2021
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 48500
Exemption Not Available
Document List
8298PSrevised.pdf
BOQ_510367.xls
Tendernotice_1.pdf
4AE9CDF7-AC8D-4930-AF68-E1585A728B2C.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 20, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 27, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 29, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

8298PSrevised.pdf

xls

BOQ_510367.xls

pdf

Tendernotice_1.pdf

html

4AE9CDF7-AC8D-4930-AF68-E1585A728B2C.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders