Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #28442083

Repair/Maintenance Of Electric And Plc Based Steam Bath , Sauna Bath Plants , Geysers , Solar Water Heater And Allied Works At Cme Repair/Maintenance Of Electric And Plc Based Steam Bath , Sauna Bath Plants , Geysers , Solar Water Heater And Allied

Issued by Statutory Bodies & Commissions/Committees · Garrison Engineer (CME) Kirkee, Maharashtra
Tender Value
25 Lakhs
Estimated cost
Bid Submission
21 Jul 2021
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Garrison Engineer (CME) Kirkee → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair / Maintenance Of Electric And Plc Based Steam Bath , Sauna Bath Plants , Geysers , Solar Water Heater And Allied Works At Cme Repair / Maintenance Of Electric And Plc Based Steam Bath , Sauna Bath Plants , Geysers , Solar Water Heater And Allied Works Under Ge ( Cme ) Kirkee

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 14-Jul-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-Jul-2021

BOQ

Name of Work: Repair/maintenance of electric and PLC based steam bath, sauna bath plants, geysers, solar water heater and allied works under GE (CME) Kirkee
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11M & L for servicing solar Flat Plate collector by removing the flange plates, cleaning the collectors internally by using descaling solution, removing the blockages in the collectors complete and refixing the flange plates, testing for satisfactory function all as specified and directed.45Each Job
22M & L for sevicing solar manifold and tank by removing all the tubes in the monifold, cleaning the tubes internally, removing the blockages in the tubes and cleaning the tank and removing all the impurities, assembling and testing for satisfactory function all as specified and directed.8Each Job
33S & F heating element 25mm to 32mm dia, ISI marked for solar water heating plant of capacity 32 KW all as specified and directed by Engr in charge.25Each
44S & F Flat Plate collector Tank 100 LPD comprising of 2.5 mm GI/0.5 mm SS304 with rockwool insulation of 50 mm including aluminium cladding and removal of old unserviceable tank complete all as specified and directed.2Each
55S & F flange plates of size 25 mm dia suitable for flat plate collectors including taking down old unseviceable flange plate all specified and directed.25Each
66S & F Flat Plate collector Tank 200 LPD comprising of 2.5 mm GI/0.5 mm SS304 with rockwool insulation of 50 mm including aluminium cladding and removal of old unserviceable tank complete all as specified and directed.1Each
77S & F thermostat for solar water heating plant suitable size and ratings etc complete.25Each
88S & F flexible heat resistance rubber pipe (from inter connect plate collector to hot water tank) of size 25 mm to 32 mm dia etc with fixing clamp etc complete all as specified.10Each
99Taking down the collector from its position, removing the top glass of collector and carry out welding/brazing work to the collector and arresting the leakages in the collector, refixing top glass back, testing for satisfactory function all as specified and directed.15Each Job
1010Taking down the old unserviceable solar flat plate collector by disconecting flange plates and rubber hose pipes and replacing with new flat plate collector of same size and model, connecting flange plates and rubber hose complete, testing for proper functioning all as specified and directed.2Each Job
1111M & L for submain wiring with two runs of 6 sq mm single core multi stranded FR PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volts and including electrical grade PVC casing caping of desired colour not less than 1.2 mm and 25 mm wide & 4 sq mm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed including taking down old wiring.\nNote :- Two run of 6 Sqmm, and one run of 4 Sqmm and one run of casing caping shall be measured as one length200RM
1212Steam Bath : Checking of electrical wire connection , level sensors, Heaters coil, earthing leakage, electronic circuits & control panel & safety arrangements of the water level & units. Cleaning the sensors, deposition of hard water tank & electrical, pneumatic valve. Proper insulation for the boilers including replacement of defective spares and fixing the same with new including testing one etc complete.\nNote - \n(a) Contractor has to visit the plant once in a month and carry out comprehensive maintenance as directed by Engr-in-Charge.\n(b) During emergency contractor has to visit the plant to rectify the fault without any extra cost to the Govt.\n(c) Any spares required during comprehensive maintenance and during emergency repairs shall be measured under respective item as \" Supply only)11Each
1313Sauna Bath :- Checking of the heater coil, electronic temp control, calibrating temp, Accuracy, safety cut off the heater & cleaning the sensors of the electronic devices / equipments etc including replacement of defective spares and fixing the same with new including testing etc complete. \nNote -\n(a) Contractor has to visit the plant once in a month and carry out comprehensive maintenance as directed by Engr-in-Charge.\n(b) During emergency contractor has to visit the plant to rectify the fault without any extra cost to the Govt.\n(c) Any spares required during comprehensive maintenance and during emergency repairs shall be measured under respective item as \" Supply only)11Each Job
1414Supply only 15 psi safety valve (Pressure relief valve)\n2Each
1515Supply only 240 V 5 amps glass fuse2Each
1616Supply only auto drain solenoid valve 12 volts 6 watts for steam bath.2Each
1717Supply only water inlet solenoid valve 12 volt 6 watts for steam bath2Each
1818Supply only Boiler insulation glass wool 25mm thick 40 Kg density with aluminium foil for one steam bath approx 3 Kg\n2Job
1919Supply only steam water level circuit board & main relay board for steam bath.2Each
2020Supply only steam generator power heating element 3000 watts for steam bath3Each
2121Supply only sauna bath heating element 3 KW for sauna bath3Each
2222Supply only mild steel powder coated exterior body including provision of analog ammeter, voltmeter LED indicators complete all as speciied and directed for steam bath.1Each
2323Supply only high limit temperature (i.e 105 degree) switch thermostat for steam bath/sauna bath2Each
2424Supply only stainless steel boiler tank as per existing make2Each
2525Supply only water level sensor with Teflon collar & S/S No. Electrodes.1Each
2626Supply only Temperature sensor including extension wire of length 6 metre for steam bath2Each
2727Supply only Digital Control steam processor circuit board Model F-65/F-95 for steam/Sauna bath. \n4Each
2828Supply only Digital Control panel ABS plastic cover for steam bath/sauna bath.\n1Each
2929Supply only Digital Control Key pad overlay cover THD85E for steam bath.\n1Each
3030Supply only step down Transformer with dual output primary 230 V and secondary 35 Volt 5 Amps for steam bath.2Each
3131Supply only Mains power Terminal 4 way connector 63 amps\n2Each
3232Supply only steam contactor 230 V coil 63 amps 3 phase 440 volt for steam plant.3Each
3333Supply only silicon heater washer2Each
3434Supply only power contactor 40 Amps 440 volts, 50 Hz3Each
3535Supply only temperature thermostat range 30 to 110 degrees.2Each
3636Supply only 4 way channel terminal strip connector 32 Amps.2Each
3737Supply only high limit upto 95o c temprature switch 40 Amps rating for steam bath.2Each
3838Supply only Sauna wooden R11 grade insulation 40 Kg density with aluminium foil.\nMake Yellow Cedar4Sq ft
3939Supply only in repairs electronic sauna room temperature controller.2Each
4040Supply only low density industrial Sauna heating element S/S, 316 Grade, 2000 watt.2Each
4141Supply only flame proof wires 6 Sqmm for Sauna heater/steam bath.20RM
4242Supply only Sauna room light switch 5 Amps.3Each
4343Supply only Sauna room light switch dimmer2Each
4444Supply only water softener KENT 300 ltr for re-generation of same model and make of exising complete all as directed.3Each
4545Comprehensive maintenance of storage type electric water heater (geyser) of capacity 25 to 50 litres comprising of the following tasks at different locations including taking down, transportation to work shop ,opening the geyser, replacement of defective spares and reinstalling the same including testing as directed by Engineer-in-charge. \nMake : Bajaj, Ditz, Primer, Galco, Racold or any other make.120Each Job
4645.1(a) Inspection of geysers includes taking down, transporting to works shop for repair, (dismantling) opening descaling, brushing cleaning of storage tank\n(b) Check and correct earth continuity of electrical items\n(c) Replacement of neon lamp / indicator lamp if defective.\n(d) Inspect over flow/vent pipes and remove blockage/ obstructions if any. \n(e) Examine water tightness tank after cleaning and necessary measures to make the same water tight if not. \n(f) Check thermostat for its proper functioning
4745.2(g) Visual examination of fusible plug to ensure its intactness.\n(h) Checking of dead weight type high pressure release valve ( PRV ) by removing dead weight protection cleaning the seat and ensuring that the vent hole is not blocked / chocked\nj) Descalling of the immersion type heating element and cleaning with diluted hydrochloric acid and refixing.\nk) Checking and adjustments of pressure reducing valves, carrying out operation of all stop cocks & ensure free movement of all working parts.\nl) Replacement of the rubber / PVC gasket to ensure water tightness\nm) Testing of Geysers after repairs\nn) Replacement of defective components such as thermostat safety valves fusible plug, Heating elements, storage tank apparatus plate etc.\nNote:- Spare components will be measured and paid separately as supply only under relevent item of Sch 'A'. These parts shall be of the same make of which the geyser is in repair.
4846Repair/checking to storage type water heater geyser of any capacity including replacement of required spares such as heating element thermostat, indicator, fusible plug dead weight,hot/cold water hose pipes incl any other etc repairs work at different locations at CME all as specified and directed by Engr in charge for the Make: Bajaj, Ditz, Primer, Galco, Racold or any other make). Note : Spare components will be mesaured and paid seperately.650Each Job
4947Supply only thermostat complete with temperature setting manually extra long (11 inches) ISI marked suitable for geysers 25 litres to 50 litres capacity260Each
5048Supply only thermostat cut-out with knob complete at tripping 90 degree (+5%) Temperature of length (7 inches) ISI marked suitable for geysers 25 litres to 50 litres capacity.260Each
5149Supply only air release valve / dead weight valve ISI marked suitable for 25 to 50 litres capacity geysers.140Each
5250Supply only fusible plug ISI marked suitable for 25 to 50 litres capacity Geysers.150Each
5351Supply only safety valve (tobe fixed on outlet connection) ISI marked suitable for 25, and 50 litres capacity geysers.175Each
5452Supply only aparatus plate for geyser 25 Ltrs capacity40Each
5553Supply only aparatus plate for geyser 50 Ltrs capacity4Each
5654Supply only heating element upto 2 KW as required at site including rubber washers (ISI Marked) with round head coil175Each
5755Supply only heating element upto 2 KW as required at site including rubber washers (ISI Marked) with small triangular head coil200Each
5856Supply only heating element upto 2 KW as required at site including rubber washers (ISI Marked) with extra large triangular head coil200Each
5957Supply only non return valve(NRV) brass of 15mm bore, after dismantling old unserviceable NRV of any size all as specified and directed.45Each
6058S & F Hot/Cold water flexible hose pipe (ALLOY FLEXIBLE HOSE PIPE 1/2\") 12mm dia and 450/600mm long heavy duty covered with metal wires heat resistence with both ends PVC hexagonal check nut with washer to fixed on 15mm dia GI pipe all as specified and directed.525Each
6159Supply only insulation material ( Glass Wool ) for geysers10Kg
6260M & L for preparation of steel surface of geysers , apply putty to make the surface smooth/ even and applying one coat of synthetic enamel paint white including writing of MES Nos with black paint complete all as directed & for any size or capacity of geysers .50Each
6361Taking down loose geysers of any capacity from wall & shifting to new place within 1 to 1.5m distance (available in same location) , refixing the geysers complete with grouting of bolts & all necessary pipe connections and making good the disturbed wall surfaces all as directed.\nNote :- GI tubing if required shall be measured and paid separately.50Each
6462M & L to repair the leakge of copper inner tank of geysers of any capacity by gas welding/brazing for water tightness complete and test under pressure.25Each
6563S & F single pole and neutral encloser with two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 volts.50Each
6664S & F GI tubing (Medium grade) with all fitting and fixed to complete on wall and ceiling or laid in trenches of size 15mm bore incl taking down old unserviceable one all as specified and directed.100RM
6765M & L for stop valve, cast copper alloy, screw down high pressure, crutch handle screwed both end for iron pipe, fancy type, chromium plated for 15mm bore pipe incl taking down old unserviceable one .64Each
6866M & L for Bib tap,fancy type, chromium plated for 15mm bore pipe62Each
6967S & F mild steel bottom/top covers for 25-50 litre capacity geysers.20Each
7068S & F gasket rubber ring for heater plate of any size geyser.30Each
7169S & F indicator lamp of geyser 25-50 litres capacity of RED/GREEN colour.300Each
7270S & L PVC copper conductor cable 3 core 2.5 sq mm flexible multistranded 1100 V grade unsheathed cable.250RM
7371M & L for switch socket combination 2 in one 3 pin 16 Amps 240 volts flush type complete all as speciied and directed.60Each
7472M & L for socket outlet 3 pin incl PVC enclosure 240 volts controlled by one MCB SP 25 Amps, Make Havells or equivalent complete all as specified and directed.100Each
7573M & L for Metal clad industrial pug top of cap 16 Amps100Each
7674M & L for plug top porcelein 3 pin 15/16A 230 V AC supply80Each
7775Supply & fix in repairs Gun metal, global or gate valves of size 15mm dia bore with iron wheel head, ISI marked screwed both ends for iron pipe and fixed complete all as specified45Each

AI Tender Summary

OUR REF NO 28442083
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 21-07-2021
Authority
Authority Name Military Engineer Services
Work Description Repair / Maintenance Of Electric And Plc Based Steam Bath , Sauna Bath Plants , Geysers , Solar Water Heater And Allied Works At Cme Repair / Maintenance Of Electric And Plc Based Steam Bath , Sauna Bath Plants , Geysers , Solar Water Heater And Allied Works Under Ge ( Cme ) Kirkee
Basic Detail
Tender No 8199
Bidding Type Tender
Location
City Garrison Engineer (CME) Kirkee
State Maharashtra
Key Dates
Publish Date 14 Jul 2021
Submission Date 21 Jul 2021
Open Date 23 Jul 2021
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Not Available
Document List
BOQ_510343.xls
8199retender07.07.2021.pdf
Tendernotice_1.pdf
AB301B80-1ECC-4468-A6CB-99394C99907F.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 14, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 21, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 23, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_510343.xls

07

8199retender07.07.2021.pdf

pdf

Tendernotice_1.pdf

html

AB301B80-1ECC-4468-A6CB-99394C99907F.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders