Ministry Of Health And Family Welfare-MOHFW has published Description Of Stores /Items: Processing Of Intra Ocular Lenses (Iols), On Case To Case Consignment Basis, On Rate Contract For A Period Of 3 Years Or Till The Finalization Of The Next Tender, Whichever Is Later. For Department Of Ophthalmology. Submission Date for this Tender is 05-08-2021. Coats and Jackets Tenders in NEIGRIHMS, Shillong, Meghalaya Meghalaya. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-Jul-2021 | Corrigendum | Technical Bid | 05-08-2021 |
Description of Stores /Items: Processing of Intra Ocular Lenses (IOL's), on case to case consignment basis, on rate contract for a period of 3 years or till the finalization of the next tender, whichever is later. For department of Ophthalmology. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Foldable Posterior Chamber Intraocular Lens (Lens Power):- \nMaterial: Acrylic, hydrophobic, Posterior truncated square edge, UV and blue light filtering, anterior biconvex, planar haptics, Optic type - Aspheric, Optic diameter - 6mm, Overall Length approx. 13.0 mm, Yellow Chromophore is a MUST, Refractive Index - Approx. 1.55, Optic thickness should be approx. <0.8mm. Smooth on Injecting the IOL into the capsular bag. No air bubble in the cartridge. Should unfold easily within 10 secs. \n | |||
2 | 1.01 | a) +17.0 D | item1 | 1 | Each |
3 | 1.02 | b) +17.5 D | item2 | 1 | Each |
4 | 1.03 | c) +18.0 D | item3 | 1 | Each |
5 | 1.04 | d) +18.5 D | item4 | 1 | Each |
6 | 1.05 | e) +19.0 D | item5 | 1 | Each |
7 | 1.06 | f) +19.5 D | item6 | 1 | Each |
8 | 1.07 | g) +20.0 D | item7 | 1 | Each |
9 | 1.08 | h) +20.5 D | item8 | 1 | Each |
10 | 1.09 | i) +21.0 D | item9 | 1 | Each |
11 | 1.1 | j) + 21.5 D | item10 | 1 | Each |
12 | 1.11 | k) +22.0 D | item11 | 1 | Each |
13 | 1.12 | l) +22.5 D | item12 | 1 | Each |
14 | 1.13 | m) +23.0 D | item13 | 1 | Each |
15 | 1.14 | n) +23.5 D | item14 | 1 | Each |
16 | 1.15 | o) +24.0 D | item15 | 1 | Each |
17 | 1.16 | p) +24.5 D | item16 | 1 | Each |
18 | 1.17 | q) +25.0 D | item17 | 1 | Each |
19 | 1.18 | r) +25.5 D | item18 | 1 | Each |
20 | 1.19 | s) +26.0 D | item19 | 1 | Each |
21 | 2 | Foldable pre-loaded IOL with Delivery System (IOL Powers):- \nMaterial: Acrylic, hydrophobic, Posterior truncated square edge & anterior biconvex, planar haptics, Optic type – Aspheric, Optic diameter - 6mm, Overall length approx. 13.0 mm, Light filtration - UV, Blue light filtering & Yellow Chromophore is a MUST, Smooth on Injecting the IOL into the capsular bag. Should unfold easily within 10 seconds. Refractive index approx 1.55, Optic thickness <0.8mm, microincision 2.2mm disposable injector. Delivery system/injector must be provided. From reputed company\n | |||
22 | 2.01 | +20.0 D | item20 | 1 | Each |
23 | 2.02 | +20.5 D | item21 | 1 | Each |
24 | 2.03 | +21.0 D | item22 | 1 | Each |
25 | 2.04 | +21.5 D | item23 | 1 | Each |
26 | 2.05 | +22.0 D | item24 | 1 | Each |
27 | 2.06 | +22.5 D | item25 | 1 | Each |
28 | 2.07 | +23.0 D | item26 | 1 | Each |
29 | 2.08 | +23.5 D | item27 | 1 | Each |
30 | 2.09 | +17D | item28 | 1 | Each |
31 | 2.1 | +18D | item29 | 1 | Each |
32 | 2.11 | +19D | item30 | 1 | Each |
33 | 2.12 | +24D | item31 | 1 | Each |
34 | 2.13 | +25D | item32 | 1 | Each |
35 | 3 | Toric Foldable Posterior Intraocular Lens (Lens Power):-\nMaterial: Foldable TORIC IOLs, Acrylate/Methacrylate Copolymer, Hydrophobic, Posterior Square-edge, Biconvex, Optic-Aspheric, Optic diameter - 6mm, UV-blocking, Blue light & Yellow Chromophore is a MUST. Ant. Surface aspheric, Single-piece IOL with diffracrive, Should also provide: (i) Fixation ring with DEGREE GAUGE/ MARKER for accurate axis alignment, (ii) AXIS MARKER (intraoperative) to mark axis on cornea to be provided, IOL cylinder powers (diopters) +1.50D to 6.00D, Smooth on Injecting the IOL into the capsular bag. No air bubble in the cartridge. Should unfold easily within 10 secs. \n | |||
36 | 3.01 | +19.0D | item33 | 1 | Each |
37 | 3.02 | +19.5D | item34 | 1 | Each |
38 | 3.03 | +20.0D | item35 | 1 | Each |
39 | 3.04 | +21.5D | item36 | 1 | Each |
40 | 3.05 | +22.0D | item37 | 1 | Each |
41 | 3.06 | +22.5D | item38 | 1 | Each |
42 | 3.07 | +23.0D | item39 | 1 | Each |
43 | 3.08 | +23.5D | item40 | 1 | Each |
44 | 4 | Trifocal IOLs: (1) High End Quality :- \nFoldable Hydrophobic (>90%) Acrylic IOLs, 3 focal points, Optic of Lens should have truncated square edge. Refractive-Diffractive Optic, Wide range of diopter 6D to 30D. Microincision 2.2mm disposable catridge/Preloaded Injector. Truncated square edge, Optic diameter - 6mm, Diopter Approx - 12.5D, C-Loops Haptics, Refractive Index: Approx 1.55. Good defocus Aspheric surface curve, Negligible or No Glare, Halos or scattering of light, Should provide good contrast sensitivity, Should provide clear, far, intermediate - Near vision, Slanted Transition Zones, Reduced Pupillary dependence, Balanced distribution of light, Able to tolerate some decentration, Near Add: Approx. +2.0 Intermediate: Approx 3.50D, UV, Blue light filter & Yellow Chromophore is a MUST. Smooth Injection of IOL. Should unfold easily within 10 seconds. \n | |||
45 | 4.01 | +19.0D | item41 | 1 | Each |
46 | 4.02 | +19.5D | item42 | 1 | Each |
47 | 4.03 | +20.0D | item43 | 1 | Each |
48 | 4.04 | +20.5D | item44 | 1 | Each |
49 | 4.05 | +21.5D | item45 | 1 | Each |
50 | 4.06 | +22.0D | item46 | 1 | Each |
51 | 4.07 | +22.5D | item47 | 1 | Each |
52 | 4.08 | +23.0D | item48 | 1 | Each |
53 | 4.09 | +23.5D | item49 | 1 | Each |
54 | 5 | Trifocal IOLs: (2) Under 'Make in India' initiative:- \nFoldable Hydrophobic (>90%) Acrylic IOLs, 3 focal points, Optic of Lens should have truncated square edge. Refractive-Diffractive Optic, Wide range of diopter 6D to 30D. Microincision 2.2mm disposable catridge/Preloaded Injector. Truncated square edge, Optic diameter - 6mm, Diopter Approx - 12.5D, C-Loops Haptics, Refractive Index: Approx 1.55. Good defocus Aspheric surface curve, Negligible or No Glare, Halos or scattering of light, Should provide good contrast sensitivity, Should provide clear, far, intermediate - Near vision, Slanted Transition Zones, Reduced Pupillary dependence, Balanced distribution of light, Able to tolerate some decentration, Near Add: Approx. +2.0 Intermediate: Approx 3.50D, UV, Blue light filter & Yellow Chromophore is a MUST. Smooth Injection of IOL. Should unfold easily within 10 seconds. From Indian company under 'Make in India' initiative. \n | |||
55 | 5.01 | +19.0D | item50 | 1 | Each |
56 | 5.02 | +19.5D | item51 | 1 | Each |
57 | 5.03 | +20.0D | item52 | 1 | Each |
58 | 5.04 | +20.5D | item53 | 1 | Each |
59 | 5.05 | +21.5D | item54 | 1 | Each |
60 | 5.06 | +22.0D | item55 | 1 | Each |
61 | 5.07 | +22.5D | item56 | 1 | Each |
62 | 5.08 | +23.0D | item57 | 1 | Each |
63 | 5.09 | +23.5D | item58 | 1 | Each |
64 | 6 | Scleral fixated IOL:\nA) Rigid, PMMA IOL,Optic diameter - 6mm, Eyelets for tying sutures, Scleral fixated type, UV, Blue light filter &Yellow Chromophore is a MUST. \n | |||
65 | 6.01 | +18.0D | item59 | 1 | Each |
66 | 6.02 | + 19.0D | item60 | 1 | Each |
67 | 6.03 | + 20.0D | item61 | 1 | Each |
68 | 6.04 | + 20.5D | item62 | 1 | Each |
69 | 6.05 | + 21.5D | item63 | 1 | Each |
70 | 6.06 | + 22.0D | item64 | 1 | Each |
71 | 7 | Scleral fixated IOL (Foldable):-\n(B) Foldable IOL with haptic material for making a FLANGE with cautery for Yamane technique,Optic diameter - 6mm, UV, Blue light filter & Yellow Chromophore is a MUST. \n | |||
72 | 7.01 | +18.0 D | item65 | 1 | Each |
73 | 7.02 | + 19.0D | item66 | 1 | Each |
74 | 7.03 | + 20.0D | item67 | 1 | Each |
75 | 7.04 | + 20.5D | item68 | 1 | Each |
76 | 7.05 | + 21.5D | item69 | 1 | Each |
77 | 7.06 | + 22.0D | item70 | 1 | Each |
78 | 8 | Phakic IOL/ Intra Cameral Lens (ICL):- \nIntracameral Phakic IOL, Collamer/Hybrid Acrylic material, Power range: +15D to -30D, in 0.5D steps, Optic type : Aspheric Vault height : Approx 1-1.8mm, overall length Approx. 11-14 mm (in 0.25mm steps) Adequate number of holes for aqeous flow, Adequate number of haptic pads to ensure better stability, Refractive Indx: Approx. 7.465. Delivery system should be provided. | item71 | 1 | Each |
79 | 9 | Scleral fixated IOL:- Rigid, PMMA IOL, Optic diameter - 6mm, Eyelets for tying sutures, Scleral fixated type | |||
80 | 9.01 | +18.0 D | item72 | 1 | Each |
81 | 9.02 | + 19.0D | item73 | 1 | Each |
82 | 9.03 | + 20.0D | item74 | 1 | Each |
83 | 9.04 | + 20.5D | item75 | 1 | Each |
84 | 9.05 | + 21.5D | item76 | 1 | Each |
85 | 9.06 | + 22.0D | item77 | 1 | Each |
86 | 10 | Phakic IOL/ Intra Cameral Lens (ICL):- Intracameral Phakic IOL, Collamer/Hybrid Acrylic material, Power range: +15D to -30D, Adequate number of holes for aqeous flow, Adequate number of haptic pads to ensure better stability, Delivery system should be provided | item78 | 1 | Each |
87 | 11 | Injections: | |||
88 | 11.01 | Inj. Ranibizumab for intra vitreal inj. 0.05ml (10mg/ml) - Inj. Ranibizumab 10 mg/ml. For INTRAOCULAR USE ONLY | item79 | 1 | Each |
89 | 11.02 | Inj. Dexamethasone Implant (Ozurdex) 0.7mg - Intravitreal Implant, .07 mg Dexamethasone. Pre-loaded single use.For INTRAOCULAR USEONLY | item80 | 1 | Each |
90 | 11.03 | Inj. 20% Sodium fluosrscein Eye - Inj. 20% Sodium fluosrscein Eye. For Fundus Fluorescein Angiography | item81 | 1 | Each |
91 | 11.04 | Inj. Trypan Blue - Trypan Blue - 0.6 mg, Sodium Chloride I.P - 8.2 mg, Sterile aqueous base - q.s, FOR INTRAOCULAR USE ONLY | item82 | 1 | Each |
92 | 11.05 | Inj.Hyaluronidase 1500 (HYALASE/FACIDASE) - Each vials contains Hyaluronidase (ovine) IP 1500 IU, Excipients q.s,. FOR INTRAOCULAR USE ONLY | item83 | 1 | Each |
93 | 11.06 | Inj. (Hydroxypropyl Methyl cellulose Ophthalmic. Soln. 2%) (intraocular use) - Sterile, isotonic, apyrogenic viscoelastic sollution, Hydroxy Propyl Methyl Cellulose (HPMC) solution, high molecular weight. Viscosity - 4500 to 5500 cps and the pH is 6.8 to 7.4. For INTRAOCULAR USE ONLY. | item84 | 1 | Each |
94 | 11.07 | B-Hex Pupillary Expander with Injector - Soft foldable material for expansion of non dilating pupil, Should be able to go in of ? 3 mm incision size | item85 | 1 | Each |
95 | 12 | Ophthalmic Viscoelastic Devices:- \n Hyopt Plus Injection:- Each 0.5ml Sodium Hyaluronate Ophthalmic Slution contains: Na hyaluronate BP 11.9mg +, Na Chloride USP 7.20 mg+, Di-sodium hydrogen phosphate De-Hydrate USP 0.238mg+, Na Di-HydrogenPhosphate Ponohydrate USP 0.034mg+, Water for injection USP q.s.\n | item86 | 1 | Each |
96 | 13 | Iris Hook - Flexible iris retractors, disposable. Prolene material | item87 | 1 | Each |
97 | 14 | Artificial Eye Ball Implant | |||
98 | 14.01 | Hydro Apatite -Adult | item88 | 1 | Each |
99 | 14.02 | Hydro Apatite -Paediatric | item89 | 1 | Each |
100 | 14.03 | Hydro Apatite -Infant | item90 | 1 | Each |
101 | 14.04 | Eye Shield Confromer -Infant | item91 | 1 | Each |
102 | 14.05 | Eye Shield Confromer -Adult | item92 | 1 | Each |
103 | 15 | I -Care Rebound Tonometer Disposable Probes -Disposable probes compatible for I-Care Rebound Tonometer | item93 | 1 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy