| 1 | 1 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of enches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.\n\n\n\n | Item1 | 17.61 | Cum. |
|---|
| 2 | 2 | Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type\n\n | Item2 | 4.4 | Cum. |
|---|
| 3 | 3 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth | Item3 | 7.92 | Cum. |
|---|
| 4 | 4 | Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded Damp proof course 4cm thick of cement | Item4 | 5.78 | Sqm |
|---|
| 5 | 5 | 20 mm thick cement plaster in damp proof course 1:3 with two coats of bitumen at 1.65Kg. Per Sqm laid hot and sanded (Long & Short Wall inside & Outside vertical) | Item5 | 15.14 | Sqm |
|---|
| 6 | 6 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containing chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides up to height of 300mm by uniformly spraying solution @ 5 Litre / sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter (width - 300 mm, depth - 450 mm) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per sqm. (184.15 x 5 Ltr)\n\n\n\n | Item6 | 37.95 | ltr |
|---|
| 7 | 7 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level\n\n\n\n\n\n\n\n \n\n\n | Item7 | 22.51 | Cum |
|---|
| 8 | 8 | Embedding asbestos cement 100mm dia rain water pipe in cement mortar curing masonry works | Item8 | 3.5 | Mtr |
|---|
| 9 | 9 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 | Item9 | 1 | No. |
|---|
| 10 | 10 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 | Item10 | 1 | No. |
|---|
| 11 | 11 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metre | Item11 | 26.53 | Cum. |
|---|
| 12 | 12 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggrigate 40 m guage and 100 mm fine sand filling using mechanical mixer for mixing of material\n | Item12 | 34.83 | sqm |
|---|
| 13 | 13 | Centering and shuttering for faces of conc.foundations & foundation beam and plinth beam ( Vertical or battering )columns (Square or rectangular\nor poly gonal in plain)\n\n \n | | | |
|---|
| 14 | 14 | Foundation beam | Item13 | 11.57 | Sqm |
|---|
| 15 | 15 | Centring and shuttering for sides and soffits of beams, beam | Item14 | 4.18 | Sqm |
|---|
| 16 | 16 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. | | | |
|---|
| 17 | 17 | Slab | Item15 | 34.84 | Sqm |
|---|
| 18 | 18 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer using batch type concrete mixer as per IS: 1791 and vibrated by needle vibrator but excluded steel reinforcement centering and shuttering in foundation.\n\n\n\n | | | |
|---|
| 19 | 19 | Foundation Beams | Item16 | 4.34 | Cum |
|---|
| 20 | 20 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. | Item17 | 5.14 | Cum |
|---|
| 21 | 21 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. \n\n | Item18 | 24.39 | Rmt |
|---|
| 22 | 22 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing\n | Item19 | 34.85 | Sqm. |
|---|
| 23 | 23 | 12.5 mm thick cement plaster 1:5\n\n\n\n\n\n\n\n\n \n\n | Item20 | 72.11 | Sqm. |
|---|
| 24 | 24 | 12.5 mm thick cement plaster 1:4\n\n\n\n\n\n\n\n\n \n\n | Item21 | 120.94 | Sqm. |
|---|
| 25 | 25 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to\nIS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ).\n | Item22 | 38.57 | Sqm. |
|---|
| 26 | 26 | Black granite stone tiles 20mm thick in skirting, risers of steps dado, walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement, 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowels pins and cramps. (14.91) | Item23 | 1 | Sqm. |
|---|
| 27 | 27 | Moulding of the granite stone to be fixed on the edges | Item24 | 13.75 | ft |
|---|
| 28 | 28 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 550 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete (18.18) | Item25 | 9.75 | Qtl |
|---|
| 29 | 29 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using Acryllic Wall Putty by applying two or more coats to get required finish including priming coat to make an even surface before applying Acrylic wall putty on new plastered surface.Complete as per specifications | Item26 | 72.11 | Sqm |
|---|
| 30 | 30 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats on old distempered work when shade is changed | Item27 | 72.11 | Sqm |
|---|
| 31 | 31 | Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete | Item28 | 120.94 | Sqm |
|---|
| 32 | 32 | Providing & Fixing of jalli at service window for protection of flies etc. Complete in all respects | Item29 | 1 | Job |
|---|
| 33 | 33 | Public Health | | | |
|---|
| 34 | 34 | Excavation manually in trenches with straight or open cutting in a builtup street/Lanes having wall to wall width upto 3 meter for sewer and manholes to full depth as shown in drawings including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning roads, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of works upto 15 mtr., for all works other than connections to complete in all respects. | | | |
|---|
| 35 | 35 | For depth not exceeding 2 m. below Ground\nlevel | | | |
|---|
| 36 | 36 | All Classes of Soil Except Rocky | Item30 | 27 | Cum |
|---|
| 37 | 37 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. | | | |
|---|
| 38 | 38 | Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal | Item31 | 1 | Each |
|---|
| 39 | 39 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. | | | |
|---|
| 40 | 40 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm | Item32 | 1 | Each |
|---|
| 41 | 41 | Cutting holes upto 23cm square through B.B.\nin cement walls or stone masonary wall in\ncement for pipes, and making good the same\n& finishing according to existing finish where\nrequired. | | | |
|---|
| 42 | 42 | Through wall 22.86 cm thick | Item33 | 3 | Each |
|---|
| 43 | 43 | Cutting chase in brick walls in cement or in floor\nfor embedding G.I. or C.I pipes line and making\ngood the same to its original condition. | | | |
|---|
| 44 | 44 | Size 75 mm x 75 mm | Item34 | 15 | Mtr. |
|---|
| 45 | 45 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. | | | |
|---|
| 46 | 46 | Single Socket Type B | | | |
|---|
| 47 | 47 | 110mm o/d SWR UPVC pipe lines laid complete | Item35 | 12 | Mtr. |
|---|
| 48 | 48 | 90mm o/d SWR UPVC pipe lines laid complete | Item36 | 8 | Mtr. |
|---|
| 49 | 49 | Providing and fixning PVC Bend 3\" i/c CC Block 1 : 2 : 4 complete in all respects. | Item37 | 3 | Each |
|---|
| 50 | 50 | Providing and fixing PVC socket 3\" complete in all respects. | Item38 | 4 | Each |
|---|
| 51 | 51 | Providing and fixing in position SWR UPVC special for soil waste ventor antisyphonage pipes as per as per IS- 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc.and making good toits original condition but excluding cost of lead joining | | | |
|---|
| 52 | 52 | For 110mm o/d pipes | | | |
|---|
| 53 | 53 | Floor Trap 110mm x 110mm | Item39 | 3 | Each |
|---|
| 54 | 54 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge) complete in all respect. | | | |
|---|
| 55 | 55 | C.P.brass 15mm Angle valve without flange | Item40 | 3 | Each |
|---|
| 56 | 56 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. | Item41 | 3 | Each |
|---|
| 57 | 57 | Providing ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B-Class including cost of specials (such as tees,bends, sockets, elbows etc.) ,painting withanti corrosive bitumastic paint, testing,cutting, threading Inside building complete | | | |
|---|
| 58 | 58 | 15mm i/d | Item42 | 10 | Mtr. |
|---|
| 59 | 59 | 20mm i/d | Item43 | 40 | Mtr. |
|---|
| 60 | 60 | Providing, fixing and jointing G.I Union Couplings (of approved make with theapproval EIC) as per IS 1879 in G.I. Pipelines complete in all respect | | | |
|---|
| 61 | 61 | 15mm i/d | Item44 | 2 | Mtr. |
|---|
| 62 | 62 | 20mm i/d | Item45 | 4 | Mtr. |
|---|
| 63 | 63 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. | | | |
|---|
| 64 | 64 | Triple Layer Tanks (1 x 1000 ltr) | Item46 | 1000 | ltr |
|---|
| 65 | 65 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-incharge) in PVC Water storage tanks complete in all respect. | | | |
|---|
| 66 | 66 | G.I. tank nipple 20mm i/d | Item47 | 2 | Each |
|---|
| 67 | 67 | Providing and fixing in position automatic brass Ball Cock in tanks with plastic rod and ball | | | |
|---|
| 68 | 68 | 20mm i/d | Item48 | 1 | Each |
|---|
| 69 | 69 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. | | | |
|---|
| 70 | 70 | 20mm i/d Brass Ball valves | Item49 | 2 | Each |
|---|
| 71 | 71 | Construction of platform for placing PVC water storage tank with BB work, Plaster CC 1:8:16, 1:2:4, cement randering etc of size Complete in all respects | Item50 | 1 | Job. |
|---|
| 72 | 72 | Making connection with the existing G.I. branch main up to 40mm size pipe including cutting of existing pipe line, threading of pipe lines from both ends and fixing of G.I Tee etc. in the pipe line (including cost of G.I Tee) complete in all respects. | Item51 | 1 | Each |
|---|
| 73 | 73 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect. | | | |
|---|
| 74 | 74 | C.P. Brass extension piece, 25mm long to 50mm long | Item52 | 3 | Each |
|---|
| 75 | 75 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. | Item53 | 3 | Each |
|---|
| 76 | 76 | Providing & Fixing of MINI FORCE II -MONOSOFT PUMP Pressure Pump Crompton Greaves or Equivalent having power .37/.5 KW / HP, Head 6-24 Metres,Discharge 2000-450 LPM,Single Phase, Voltage 220 Volts +6 %-15 %, Insulation Class B Complete in all respects | Item54 | 1 | Each |
|---|
| 77 | 77 | Providing Shed for Terrace Pump Complete in all respects | Item55 | 1 | Job |
|---|
| 78 | 78 | Electrical Work | | | |
|---|
| 79 | 79 | Providing and fixing 2' x 2' Led Panel Light 36 Watt Cap. of make Philips/Havels/Opel/Syska or any other equivelant make complete in all respects. | Item56 | 4 | Each |
|---|
| 80 | 80 | Supply and Erection of CEILING FAN of suitable size 1200mm, Energy saver white color, Make Anchor Model no:-Penta Turbo star 13671, Make Polar, Make Polycab Model no:-Synergy 50, including necessary connection/testing, complete in all respect as desired by the Engineer-In-Charge of work at site and equivalent Havell’s/Anchor/ Polycab. Complete in all respects | Item57 | 3 | Each |
|---|
| 81 | 81 | Supply and Erection of EXHAUST FAN of suitable size 450mm, white color, Make Anchor Model no:-Anmol 14050GY, Make Havells Model no:- Trubo force SP, Make Polycab Model no:-Superb HDX, including necessary connection/testing, complete in all respect as desired by the Engineer-In-Charge of work at site and equivalent Havell’s/Anchor/ Polycab. Complete in all respects | Item58 | 1 | Each |
|---|
| 82 | 82 | Supply And Erection Of LED Tube Light 1200mm long having 20 Wattage, Make Crompton, Jaguar, C&S, Syska Model no:-SSK-ALB -20W Including Necessary Connection/Testing,Complete In All Respect As Desired By The Engineer-In-Charge Of Work At Site And Equivalent Make Jaquar/C&S/ Crompton/Syska. Complete in all respects | Item59 | 1 | Each |
|---|
| 83 | 83 | Recessed PVC Conduit Pipe Wiring System With Modular Switches: | | | |
|---|
| 84 | 84 | Wiring In Pvc Insulated Copper Conductor Single Core Fr Cable (Isi Marked), 1100volts Grade To Be Laid In Heavy Gauge, Pvc, Fire Retardant Conduit Pipe 20mm/25mm Dia. Isi Marked, Recessed In Wall Etc., Complete With Powder Coated/Anodized Concealed Metal Boxes Required For Suitable Number Of Modules, For Having Electronic Fan Regulators, Bell Push, Electronic Buzzer, 3pin 6amp., 3pin 16/20amp. Sockets And 6amp./16/20amp. Switches (Screw Type Modular Accessories) Etc., And Covered With Frame Plate Etc., & Including The Cost Of Required Number Of Modular Switches/Sockets, Step Type Electronic Fan Regulator 100watts, Pvc Connector (For Fan Box And Electronic Buzzer), Steel Hooks, Circular Inspection Box (Recessed Type And Deep Type) Pvc Conduit Pipe & Copper Wire And Other Petty Material Etc. Including The Cost Of Cutting And Filling Up Of Chases:- | | | |
|---|
| 85 | 85 | Wiring fan point (Without fan box) | Item60 | 3 | Each |
|---|
| 86 | 86 | Wiring light point | Item61 | 2 | Each |
|---|
| 87 | 87 | Wiring 6Amp. wall socket point | Item62 | 5 | Each |
|---|
| 88 | 88 | Wiring 16/20Amp. power plug control point | Item63 | 7 | Each |
|---|
| 89 | 89 | Wiring light point with double control switches. | Item64 | 1 | Each |
|---|
| 90 | 90 | PVC INSULATED FRLS COPPER CONDUCTOR CABLES: | | | |
|---|
| 91 | 91 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- | | | |
|---|
| 92 | 92 | Overall size 1 sq.mm (Un-sheathed) | Item65 | 30 | Mtr. |
|---|
| 93 | 93 | Overall size 1.5 sq.mm (Un-sheathed) | Item66 | 30 | Mtr. |
|---|
| 94 | 94 | Overall size 4 sq.mm (Un-sheathed) | Item67 | 30 | Mtr. |
|---|
| 95 | 95 | Providing and fixing internet router of reputed make complete in all respects. | Item68 | 1 | Each |
|---|
| 96 | 96 | Supply Installation Testing and Commissioning of Cat 6 UTP Cable. Complete in all repsects as desired by the Engineer in charge of work at site Complete in all respects | Item69 | 50 | Mtr. |
|---|
| 97 | 97 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES | | | |
|---|
| 98 | 98 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- | | | |
|---|
| 99 | 99 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) On Surface | Item70 | 30 | Mtr. |
|---|
| 100 | 100 | Supply Installation Testing and Commissioning of RJ11 Telephone socket outlets with shutter suitable for 2 core telephone jack. Complete in all repsects as desired by the Engineer in charge of work at site Complete in all respects | Item71 | 2 | Each |
|---|
| 101 | 101 | MINIATURE CIRCUIT BREAKERS: | | | |
|---|
| 102 | 102 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PW General Specifications including connections with suitable size of thimbles/ lugs:- | | | |
|---|
| 103 | 103 | MCB Double Pole 6-32amp. (10kA, Curve-\nC) | Item72 | 2 | Each |
|---|
| 104 | 104 | MCB Single Pole 6-32amp. (10kA, Curve-C) | Item73 | 4 | Each |
|---|
| 105 | 105 | SHEETMETALDOUBLEDOORDISTRIBUTIONBOARD FORMCB's/RCBO's/ RCCB's | | | |
|---|
| 106 | 106 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as perIS 8623-1&3, IEC 61439-1&3 suitable forflush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cableties, blanking plates and circuit identifications label and of required no.of ways for mounting miniature circuitbreakers/ RCBO's/ RCCB' sinthe distribution board (For SP & Ndistribution board with provision DPMCB's/ RCCB's/ RCBO's as incomer andSP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's asoutgoings) as per PWD General specifications including connections with suitable size of thimbles andbonding to existing earth etc: | | | |
|---|
| 107 | 107 | TP&N Vertical Double Door Distribution Board 4 way each | Item74 | 1 | Each |
|---|
| 108 | 108 | Ceiling Work and Aluminium Work | | | |
|---|
| 109 | 109 | Providing and Fixing ceiling consisting of 12.5 mm thick Gypsum Board of any size G.I. Cradlinghanged from the ceiling by means of G.I. hangercomplete as per drawings,specifications and totheentire satisfaction of engineer-in- charge. | Item75 | 10.31 | Sqm |
|---|
| 110 | 110 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, draw | | | |
|---|
| 111 | 111 | With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm | Item76 | 24.53 | Sqm |
|---|
| 112 | 112 | Providing and fixing Alumiumum doors of size 3'-6\"x 6 '9\" made out of section (Section (4\"x1.75\" ie 100mmx50mmx2 mm thick @ 1.576 KG/M-CHOWKAT ) & (Section (3.25\"x1.5\" ie 81.25 mmx38.10 mmx1.75 mm [email protected] kg/m- FOR SHUTTERS) including cost of aluminium Angles, Prelaminated board, 5mm thick floating glass, perforated filming on glass including door clousre and other accessories complete in all respects. | | | |
|---|
| 113 | 113 | Alumiumum doors of size 3'-6\"x 6 '9\" | Item77 | 1 | No. |
|---|
| 114 | 114 | Providing and fixing Alumiumum doors of size 3'-6\"x 8'3\" made out of section (Section (4\"x1.75\" ie 100mmx50mmx2 mm thick @ 1.576 KG/M-CHOWKAT ) & (Section (3.25\"x1.5\" ie 81.25 mmx38.10 mmx1.75 mm [email protected] kg/m- FOR SHUTTERS) including cost of aluminium Angles, Prelaminated board, 5mm thick floating glass, perforated filming on glass including door clousre and other accessories complete in all respects. | Item78 | 1 | No. |
|---|
| 115 | 115 | Providing and fixing Alumiumum window of required size 6'9\"x4'9\" made out of section (4\"x1.75\" ie having 3'9\"x3'3\" openable & top 1'6\" fixed portion having two shuuters (1 no. glass shutter and one no.wire mesh shutter each) 100mmx50mmx1.70 mm thick-@ 1.576 KG/M-FOR CHOWKATS) & (2.5\"x1.25\"ie 63mmx38.10mmx1.47mm thick-@ 0.781 KG/M- FOR SHUTTERS including cost of aluminium Angles, 5mm thick floating glass, perforated filming on glass and other accessories complete in all respects. | Item79 | 1 | No. |
|---|
| 116 | 116 | Providing and fixing Alumiumum ventilator of required size 12' x1' 6\" made out of section (4\"x1.75\" ie 100 mm x 50 mm x 2 mm thick @ 1.576 kg/m@ 1.576 KG/M-CHOWKAT ) & having provision for fixing of exhaust fan including cost of aluminium Angles, 5mm thick floating glass, perforated filming on glass and other accessories complete in all respects. | Item80 | 1 | No. |
|---|
| 117 | 117 | Providing and fixing Alumiumum partitionin room upto 6'9\" height of required size made out of section (4\"x1.75\" ie 100 mm x 50 mm x 2 mm thick @ 1.576 kg/mwith 12 mm thick particle board & 5mm thick floating glass, perforated filming on glass and other accessories complete in all respects. | Item81 | 1 | Job |
|---|
| 118 | 118 | Air Conditioning | | | |
|---|
| 119 | 119 | Providing and installing Daikin / Carrier / Toshiba/make 3-Star rating with EER>3.5 Fixed Speed Model (Hi-wall Cooling only without installation kit i.e. Copper Pipe) or any other equivalent make Split type Air Conditioner of 2.0 Ton capacity suitable for 230 Volts single phase supply with nature friendly refrigerant R32 or equivelant capable of performing the following functions :- (i) Cooling (ii) Dehumidifying (iii) Air Circulation (iv) Filtering including installation charges. complete in all respects. | Item82 | 1 | each |
|---|
| 120 | 120 | Providing and fixing Plug Top for fixing with stabilizer complete in all respect. | Item83 | 1 | each |
|---|
| 121 | 121 | Providing and installing Automatic Voltage Stabilizer of 4 KVA/5 KVA capacity of reputed make along with Ampere Meter, Volt Meter & 3 core wire of 1½ metre length complete in all respect. | Item84 | 1 | Each |
|---|
| 122 | 122 | Providing and fixing refrigerant copper pipe for Split type Air Conditioner including insulation complete suitable for 1.5 TR Cap Air Conditioner make Total Line or any other equivalent make. complete in all respects | Item85 | 3 | per Rmt. |
|---|
| 123 | 123 | Providing and fixing 15 mm i/d PVC drain pipe with specials for Split type Air Conditioner complete in all respects of approved make. complete in all respects | Item86 | 3 | per Rmt. |
|---|
| 124 | 124 | Providing and fixing PVC 70/76, 3 Core Electrical Wire for Split type Air Conditioner complete in all respects make Finolex, Havels or any other equivelant make. complete in all respects | Item87 | 6 | per Rmt. |
|---|
| 125 | 125 | Providing and fixing PVC 4 Core Power Cable for Split type Air Conditioner of make Finolex/Havels or any other equivelant make complete in all respects. | Item88 | 6 | per Rmt. |
|---|
| 126 | 126 | Fire Fighting | | | |
|---|
| 127 | 127 | Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all Accessories as per Manufactures Specification. ISI Mark omplete in all respect. \n4 Kg. Capacity | Item89 | 1 | No. |
|---|
| 128 | 128 | Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.\n3 Kg. Capacity | Item90 | 1 | No. |
|---|
| 129 | 129 | Misc Work | | | |
|---|
| 130 | 130 | Provding and Fixing of fibre Sheet shed out side lab for public. complete in all respects | Item91 | 120 | Sft |
|---|
| 131 | 131 | Providing and laying 50 mm thick factory made cement concrete interlocking paver block of M-30 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Non traffic Areas and streets having width less than 3.05 mt. ( Also not to used over foot Paths). | Item92 | 11.15 | Sft |
|---|