![https://www.tenderdetail.com Tender Details](/Content/img/TenderDetail.png)
![Tender Detail](/Content/img/TenderDetail.png)
Public Works Department-PWD has published Providing Ei Work In The Building Construction Of 100 Seated Girls Hostel G Plus2 Storied At Dr Br Ambedkar Hostel Complex Jagannathbari Road Agartala Providing Ei Work In The Building Construction Of 100 Seated Girls Hostel G Plus 2 Storied At Dr Br Am. Submission Date for this Tender is 28-07-2021. Electrical Maintenance Tenders in Agartala Tripura. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required:- |
2 | Short point:- |
3 | Medium point:- |
4 | Long point:- |
5 | Providing and fixing of 3 pin 5/6 amps plug point withpianotype 5/6ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required:- |
6 | Providing and fixing of 3/6 pin15/16 amps plug point withpianotype 15/16ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required:- |
7 | Wiring for Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC casing capping etc. as required:- |
8 | 2 x 1.5sq.mm:- |
9 | 2 x 2.5 sq.mm:- |
10 | 4 x 4 sq.mm:- |
11 | 4 X 10 sq mm |
12 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
13 | 1 X 1.5 sq mm |
14 | Supplying and fixing of the following PVC conduit (medium gauge) with all accessories on slab/recessed on wall etc as required. |
15 | 19/20 mm dia |
16 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
17 | Ding dong call bell |
18 | 32 amps DP kit kat switch:- |
19 | 2.5 mfd fan capacitor |
20 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
21 | 102mm x 178mm (4" X 7") :- |
22 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12"x 12" having locking arrangement including CC work, holes on earth pipe etc. as required. |
23 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
24 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
25 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of4.06mm (8SWG) dia G.I./ Copper wire forearth connection from earth electrodes etc as required. |
26 | Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W) : - |
27 | Supplying & fixing of electronic 5 step fan regulator in existing switch board including necessary connection etc as required:- |
28 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- |
29 | Supplyingof 400 mm sweep AC padestal fan with metal blade etc as required:- |
30 | Supplying & installation of 400 mm sweep AC wall mounting fan with plastic blade including connection etc as required:- |
31 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required: |
32 | Supplying and fixing of following luminaries complete withnecessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):- |
33 | Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) : - |
34 | Supplying and fixing of the following lighting accessories(Lamp, Ballast,Starter,Ignitor etc) and connection etc. as required. |
35 | 36/40 watt T-8/T-12 FTL lamp:- |
36 | 36/40 watt electronic ballast:- |
37 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
38 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):- |
39 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
40 | 90 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
41 | 40 watt LED post top light fixture with integral driver and high quality polycarbonate diffuser (IP 65):- |
42 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
43 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
44 | 12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
45 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- |
46 | 32 amps 415 volts TPN main switch (rewireable):- |
47 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- |
48 | 63 amps kitkat porcelain fuse unit with base(rewireable):- |
49 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required. |
50 | 4way horizontal TPN MCB DB (Double door):- |
51 | 8way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):- |
52 | Supplying & fixing of following ratings MCBB/C curve having breaking capacity10 KA in the existing MCB DB including connectionas required:- |
53 | 6 to 32 amps SP MCB:- |
54 | 40/50/63 amps TPN MCB:- |
55 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- |
56 | 40 amps FP isolator:- |
57 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
58 | 16 to 100 amps FP MCCB, Breakingcapacity 16/18KA (Thermal Magnetic):- |
59 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required |
60 | 2 core 4 Sq mm |
61 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: - |
62 | 4 sq mm |
63 | 10 sq mm |
64 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : - |
65 | 4 sqmm - 10 sqmm Cable:- |
66 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
67 | 40 mm dia |
68 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:- |
69 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
70 | Drawing of armoured/un-armoured cable with proper saddeling etc as required:- |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy