Augmentation Of Water Supply Scheme To Village Dhariwal Bhoja , Block Dhariwal , Distt . Gurdaspur , ( Under Nabard-Xxiii ) Pkg-2 Civil Works Augmentation Of Water Supply Scheme To Village Dhariwal Bhoja , Block Dhariwal , Distt . Gurdaspur , , In Village Dhariwal Bhoja-Punjab

Water Supply And Sanitation Department-WSSD has published Augmentation Of Water Supply Scheme To Village Dhariwal Bhoja , Block Dhariwal , Distt . Gurdaspur , ( Under Nabard-Xxiii ) Pkg-2 Civil Works Augmentation Of Water Supply Scheme To Village Dhariwal Bhoja , Block Dhariwal , Distt . Gurdaspur , . Submission Date for this Tender is 12-07-2021. Water Supply Project Tenders in In Village Dhariwal Bhoja Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

28418253
Augmentation Of Water Supply Scheme To Village Dhariwal Bhoja , Block Dhariwal , Distt . Gurdaspur , ( Under Nabard-Xxiii ) Pkg-2 Civil Works Augmentation Of Water Supply Scheme To Village Dhariwal Bhoja , Block Dhariwal , Distt . Gurdaspur ,
Open Tender
Indian
Punjab
In Village Dhariwal Bhoja
12-07-2021

Tender Details

Augmentation Of Water Supply Scheme To Village Dhariwal Bhoja , Block Dhariwal , Distt . Gurdaspur , ( Under Nabard-Xxiii ) Pkg-2 Civil Works Augmentation Of Water Supply Scheme To Village Dhariwal Bhoja , Block Dhariwal , Distt . Gurdaspur , ( Under Nabard-Xxiii ) Pkg-2 Civil Works

Key Value

Document Fees
INR 100 /-
EMD
INR 84189.0 /-
Tender Value
INR 42.09 Lakhs /-

BOQ Items

Name of Work: Augmentation of water supply scheme to village Dhariwal Bhoja, Block Dhariwal, Distt. Gurdaspur, (Under Nabard-XXIII) PKG-2 Civil Works Construction of Pump Chamber size 3.05×3.70mtr. with Sanitary Latrine in pump Chamber, Providing & Installing Pumping Machinery, Disinfections Unit Electronically actuated Type, All Civil Works, Supplying and laying of DI k-9 pipes, valves and specials for Rising Main, Distribution System, Water connection, Construction of 1 No. OHSR 50000 ltr capacity with FSL 20 mtr including the cost of inlet, outlet, overflow & scour & vertical pipes, CI duck foot bends, expansion joints, puddle collar, lightening conductor, earthing, MS steel ladder of tank portion stair case with G.I pipe railing on both sides Ventilation, Aluminum ladder inside OHSR, Scour/overflow Sluice valves and making connections with rising main, distribution pipe line & Carriage of materials complete in all respects.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 PUMP CHAMBER
2 1.01 Construction of Pump Chamber size 3.05 m x 3.70m without gravel pit but including electric wiring as per DWSS standard design and analysis complete in all respects. Extra for provision for Sanitary Latrine in pump chamber for foundation and plinth of WC rooms including flooring ,PVC pipes , Junction Box , 1 No. Leach Pit , Super structure WC room etc. 1 Job
3 2 PUMPING MACHINERY
4 2.01 Providing & installing, testing & commisioning of 1 no electrically driven Submersible Pump set of KSB or equivalent make of capable of delivering 3.60 lps against a head 52 mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter,Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps, Kit-Kat etc. including M.S column Pipe of IS 1239-2004 medium class suitable size 65mm & length 28mtr (in 3.00 mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 66 mtr length and 2.50 mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects
5 2.02 Rate of Motor with Pump 1 No
6 2.03 Panel Board 1 No
7 2.04 Submersible cable Size 2.50mm2 66 Mtr
8 2.05 Column Pipe (G.I) 65mm 28 Mtr
9 3 C.I.FITTING INSIDE PUMP CHAMBER
10 3.01 Providing & Installing 100 mm dia delivery main (from Tube-well to duck foot bend including cost of C.I.D/F Pipes, D/F Sluice Valves, D/F Non Return Valve & Specials as C.I. Bends, Tail Piece Tees, Pressure gauge, Air Valve,,V notch haudi etc. inside the Pump chamber as per DWSS standard design and analysis complete in all respects. (Annexure-3) As per IS1536-2001 & 1538-1993 reaffirmed 1999 1 Job
11 4 Disinfection Unit:
12 4.01 Providing Installing testing and commissioning and one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 leter of bleaching powder solution/ sodium hypo solution per hrs under maximum deliver pressure upto 7kg/cm2 and suction left not less than 1.5 meter. 1 Job
13 5 RCC OHSR
14 5.01 Constructing one No. of 50 KL 50000 ltr litres Capacity with sill level not less than 17 m height upto FSL 20 mtr from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing D.I. K-9 D/F expansion joints latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming to ISI - 13382 and C.I/D.I. D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow DI double flanged pressure pipes DI K-9 horizontally cast in sand moulds as per IS 8329-2000 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil of is less than 8.75 tone per sqm. In case the safe bearing capacity of sail is less than 8.75 tone per Sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Preminum including providing and fixing automatic Electronic Water Level control Device and Construction of Plinth protection around OHSR with masonry toe wall with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 & inside earth filling including overflow scower haudi complete in all respects. 1 Job
15 6 PVC RISING MAIN 10kg/cm2
16 6.01 Providing, laying, Fixing, jointing, cutting & testing of uPVC Pipes & Specials (10 kg./cm2) including cost of excavation complete in all respects as per ISI-4985 standard analysis.
17 6.02 110mm i/d (Mechanical) 30 mtr
18 7 Sluice Valve & Sluice Valve Chambers
19 7.01 Providing & fixing C.I/D.I Flanged end, stem of SS (AIS1410) and Bronze(gunmetal) working parts sluice valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).\n
20 7.02 100 mm i/d\n 2 Each
21 8 Consturction of masonary Sluice valve chamber excluding Sluice valve cover as per standard design & drawings of pubic health department.
22 8.01 (a) Size 0.9 m. x 0.9 m. 2 Each
23 9 DEVELOPMENT OF WATER WORKS SITE.
24 9.01 Providing & fixing 1.2mtr high fencing around the head works site with 1.65 meter post, placed every 2.5 meters apart, embedded in cement concrete blocks and every tenth post to be strutted with three rows of G.I. Barbed wire weighing 9.34 Kg per 100 meters (minimum) and fixing with GI staples tied to 6mm bar nib, with binding wire or by providing cut, including drilling holes in the post, including cost of posts, winding wire, strutted earth work in the post & aluminum painting complete in all respects as per DWSS standard Drawing 267 mtr
25 9.02 Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4" x 3", size top 3" x 3",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. 36 Nos
26 9.03 Providing & fixing D-Hook complete with MS Bolts size 300mm x 18mm as per DWSS standard Drawing 30 Nos
27 9.04 Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per DWSS standard Drawing . 4 No
28 9.05 Construction of masonry gate pillar including cost of MS Steel Gate size 1.22 m x 1.37 m as per DWSS standard Drawing 1 No
29 9.06 Construction of Foot Path with masonry toe wall & earth filling and Cement Concrete 1:8:16 with 40 mm gauge stone aggregate, 40 mm thick cement concrete topping 1:2:4, inside water works as per DWSS standard Drawing 20 mtr
30 9.07 Providing & fixing MS sign Board as per DWSS standard design 1 No
31 10 Providing, laying, Fixing, jointing, cutting & testing of uPVC Pipes & Specials (6 kg./cm2) including cost of excavation complete in all respects as per ISI-4985 standard
32 10.01 Excavation with JCB
33 10.02 uPVC Pipe 63 mm o/d 1048 mtr
34 10.03 uPVC Pipe 90 mm o/d 336 mtr
35 10.04 uPVC Pipe 110 mm o/d 65 mtr
36 10.05 Excavation with Manually
37 10.06 uPVC Pipe 63 mm o/d 2372 mtr
38 10.07 uPVC Pipe 90 mm o/d 633 mtr
39 11 Providing & fixing C.I/D.I Flanged end, stem of SS (AIS1410) and Bronze(gunmetal) working parts sluice valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).\n
40 11.01 80mm i/d 3 Each
41 12 Consturction of masonary Sluice valve chamber excluding Sluice valve cover as per standard design & drawings of pubic health department.
42 12.01 (a) Size 0.6 m. x 0.6 m. 3 Each
43 13 Contractor shall be quote rates only for dismantling of mettaled road & back filling with excavated earth fully compacted the restoration of the mettaled road to its original condition will be done by the concerned department i.e. PWD (B&R) PMB/Panchayati Raj) \n \n
44 13.01 90mm o/d 68 mtr
45 14 Dismantling and restoration brick paving complete in all respect as per DWSS
46 14.01 PVC Pipe 63mm o/d 930 mtr
47 14.02 PVC Pipe 90mm o/d 571 mtr
48 15 Dismantling and restoration of Cement Concrete Road complete in all respect as per DWSS
49 15.01 63mm o/d 1504 mtr
50 16 Household water connection ISI Marked,
51 16.01 Providing proposed water connection to house hold up to wall with providing, laying jointing, testing GI pipe lines 15mm i/d=2.50 mtr B- Class ( Above GL), Prov. & fixing MDPE pipe 15mm i/d with specials 2.00 Mtr (Below GL) including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make 204 Nos
52 17 Carriage of material \n
53 17.01 Extra Carriage & defference of quarry site of Fine Aggrigate payable \n 131.65 cum
54 17.02 Extra Carriage & defference of quarry site of Course Aggrigate (Bajri) \n 228.37 cum
55 17.03 Extra Carriage & defference of quarry site of Bricks payable \n(18.163*1000=18163) 18.163 Per Thousand
56 18 Environment Provision
57 18.01 Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil. \n 290 Sqm
58 18.02 Digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed farm yard manure @ 30% of pit volume and insecticide for termite control\n 4 Each
59 18.03 Supplying and planting permanent trees in prepared pits and watering\n\n 4 Sqm
60 18.04 Planting seedlings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedlings at 20cm distance from plant to plant and row to row.\n 4 Sqm
61 18.05 Planting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row. \n 4 Sqm
62 18.06 Providing for one way stand post with Khura complete in all respects. 1 Job
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail