Advanced Molecular Diagnostic And Research Center Equipments For The Icmr Ner-Task Force , Equipments/Instruments For Microbiology Deptt. , Assam Medical College & Hospital, Dibrugarh, Assam , Thermo Fisher Scientific, Phadia 200 (Proprietary Item) , Rea, Deptt. of Microbiology AMC Dibrugarh-Assam

Health And Family Welfare Department has published Advanced Molecular Diagnostic And Research Center Equipments For The Icmr Ner-Task Force , Equipments/Instruments For Microbiology Deptt. , Assam Medical College & Hospital, Dibrugarh, Assam , Thermo Fisher Scientific, Phadia 200 (Proprietary Item) , Rea. Submission Date for this Tender is 23-07-2021. Coats and Jackets Tenders in Deptt. of Microbiology AMC Dibrugarh Assam. Bidders can get complete Tender details and download the document.




Tender Notice

28406451
Corrigendum : Advanced Molecular Diagnostic And Research Center Equipments For The Icmr Ner-Task Force , Equipments/Instruments For Microbiology Deptt. , Assam Medical College & Hospital, Dibrugarh, Assam , Thermo Fisher Scientific, Phadia 200 (Proprietary Item) , Rea
Open Tender
Indian
Assam
Deptt. of Microbiology AMC Dibrugarh
23-07-2021

Tender Details

Advanced Molecular Diagnostic And Research Center Equipments For The Icmr Ner-Task Force , Equipments/Instruments For Microbiology Deptt. , Assam Medical College & Hospital, Dibrugarh, Assam , Thermo Fisher Scientific, Phadia 200 (Proprietary Item) , Real-Time Pcr; Specifications: An Automated System For Both Pcr And Post-Pcr End-Point Analysis, Using In-Built Peltier Based Pcr Machine; The System Should Support Applications Including Absolute And Relative Quantitation, Multiplex Pcr Allelic Discrimination, Melt Curve Analysis, Pathogen Detection And Plus/ Minus Assays Using An Internal Positive Control; Peltier Thermal Cycling For Fast-Pcr As Well As Standard-Pcr Run Available In The Same Block. 40 Cycles In Less Than 30 Minutes; The System Should Have Temperature Range Of 3-99 Degrees C With Peak Block Ramp Rate For Heating As Well As Cooling Exceeding 6 Degrees C /Second; Reaction Volume Should Be Approximately In The Range Of 5-100 Μl; The System Should Support Micro Well Plates, Individual Tubes And 8-Tube Strips; The System Should Provide Touch Screen Lcd Feature To Avoid Dependency On Computer For Operation; Should Also Be Possible To Use A Computer For System Control, Operation, Analysis And Networking Of Multiple System; Instrument Should Be Supplied With A Separate Desktopalong With A Standalone Backup System Capable Of Providing At Least 90 Minutes Of Backup Time; Usb Port For Data Export To Power Point, Excel Or Jpeg Formats Should Be Present; It Should Be An Open System To Use Reagents From Any Manufacturer; System Should Be Calibrated For Common Dyes Of Broader Wavelength Excitation And Emission Spectrum; Excitation Light Source –Laser / Led; Change Of Position, Block Or Chemistry Should Not Require Calibration Or Tools; The System Should Be Capable Of Operating At Ambient Temperatures Of 20-30 Degrees C And Relative Humidity Of 80%; Temperature Gradient Function Should Be Available In The System; Temperature Uniformity Should Be ±0.15 °C & Control Accuracy ± 0.1 °C; Temperature Increments Should Be Min. 0.1 °C/Cycle & Time Increments Should Be Min. 1 S/Cycle; It Should Have At Least 5 Chanel Multiplexingcapability In A Single Tube; Instrument Should Not Require The Use Of A Reference Dye Such As Rox And Do Not Need Regular Calibration; Instrument Should Use A Fiber-Optic Shuttle System; It Should Do Scanning Just Above The Sample & Should Guarantees The Homogeneous Excitation Of Each Individual Sample And The Reliable Recording Of The Emitted Fluorescent Signals With High Sensitivity And No Crosstalk Between Wells. Should Have A Warranty Period Of At Least 1 Year And Should Include On-Site Installation And Training. , Lyophilizer; Specifications: Should Be Fully Automated, User Friendly; Should Have Seamless Stainless-Steel Condenser; Should Have A Freeze Drying Area Of 0.12 Meter Square, Should Have 4 Trays With 8 Manifold Port; Should Have Compact Design And Operation- Suitable For Any Laboratory; Should Have Microprocessor Control With Alarm; Should Have Digital Temperature Read Out; Should Have Faster Drying Rate And Reproducible Drying; Should Have An Air Cooling System; Should Have A Cold Trap Temperature Of <=56 Deg C; Should Have A Cold Trap Capacity Of 8-10 Litres ; Should Be Capable Of Processing Biological Samples With Diverse Range Of Solvents; Vacuum Pump Specifications: Vacuum Pump Should Be Chemical Resistant. The Items Such As Vacuum Hose, Various Filters For Vacuum Pump, Drying Chamber, Rubber Valves, Etc Which Is Necessary For The Smooth Operation Of The Instrument Should Be Included; Accessories: All Accessories With Spare Parts For Immediate And Smooth Functioning Of The System. Should Have A Warranty Period Of At Least 3 Years And Should Include On-Site Installation And Training. , Hplc Specifications: System Pressure Should Have Maximum Pressure Of 1500 Bar; Should Have A Flow Range Of 0 To 5 Ml Per Minute; Should Have A Binary Pump Options With Default Gradient Delay Volume; Should Be Biocompatible; Should Have A Ph Range Of 2–12 And A Chloride Concentration Of Up To 1 Mol/L; Should Have A Modular Design; Should Have A Solvent Monitoring System; Should Have A Customizable Gradient Delay Volume To Simplify Method Transfer; Should Have An Injection Volume Range: Standard: 0.01-25 Μl, Optional: 0.01-100 Μl; Should Have Sample Cooling Range Of 4-40°C; Should Have A Sample Capacity (Standard) Of Standard 12 Mm Od Vials (= 1.5 Ml); Should Have Sampler Extension; Should Have Column Compartment Thermostatting Of 5-120 °C; Should Have Column Compartment Pre-Heater; Should Have Column Compartment Post-Column Cooler; Should Have The Following Detectors: Charged Aerosol Detector, Diode Array Detector, Fluorescence Detector, Multiple Wavelength Detector, Variable Wavelength Detector, Mass Spectrometer.Should Have A Warranty Period Of At Least 3 Years And Should Include On-Site Installation And Training. , Refrigerated Centrifuge; Specifications: Compact Refrigerated Centrifuge With Cfc Free Refrigerant; Should Have Max. Speed Of 16,500 Rpm With An Accuracy Of +/-10 Rpm; Should Have Ability To Spin For A Time Of 1 Min-99 Hr 59 Min, Short And Continuous Run; The Size Should Not Be More Than 422X628x362 (Lxwxh) Mm; Should Provide A Temperature Range Of -20 Deg C To +40 Deg C; Centrifuging Chamber Should Be Made Of Stainless Steel With 3-Layer; Should Have Powered Lid Locking; Should Have Quick And Easy Operation With The Knob; The Rotors Should Be Changed Easily; Should Have Lid Locking; Should Have Emergency Lid Lock Release Function; Should Provide Imbalance And Lid Locking Protection; Should Have Automatic Rotor Recognition; Should Have Atleast 40 Levels Of Acceleration And Deceleration.Should Have A Warranty Period Of At Least 3 Years. , Centrifuge; Specifications: Should Be A Table Top Compact Centrifuge; Should Have Max. Capacity Of Not Less Than 8 X 15 Ml; Should Have Max. Speed Of Around 6,000 Rpm With Rcf Of 3,461Xg; Should Have Ability To Spin For A Time Of 1 – 99 Min, Continuous Run, Short Cycle Mode (Impulse Key); The Size Should Not Be More Than H X W X D: 22.8 X 26.1 X 35.3 Cm; Centrifuging Chamber Should Be Made Of Stainless Steel; Should Have Viewing Port In The Lid; Should Have Powered Lid Locking; Should Have Quick-Entry Foil Keypad ; Should Have Lid Locking And Holding Function; Should Have Emergency Lid Lock Release Function; Should Provide Lid Dropping Protection; Should Have Imbalance Switch-Off Function; Should Have A 8 Place Fixed Angle Rotor For 15 Ml Tubes With Speed: 6,000 Rpm; Shouldalso Provide Fixed Angle Rotor For 50 Ml Tubes As Optional.Should Have A Warranty Period Of Atleast 3 Years. , Minus 80°C Deep Freezer; Specifications: Should Have Temperature Control/Display, Temperature Range: -50 °C To - 86°C; Capacity Cu Ft/Liters: 350 Or More; Cryo-Box Capacity 2”:230 Or More; Should Have A Max. Shelf Weight Of 120Lbs/65 Kg Or More; Should Have Refrigeration Hp: Two 1.25 Hp Each; Should Have Voltage: 230V, 50/60 Hz; Should Have Heavy Gauge, Cold Rolled Steel Cabinets With A Powder Coat Paint Finish For A Uniform Exterior That Resists Chipping And Rust; Should Have 5” (12.7 Cm) Foamed-In-Place Polyurethane Insulation; Should Have Vacuum Relief Port For Easy Access After Door Openings; Should Have Easy To Remove Washable Filter For Protection From Dust On The Condenser And Increasing Refrigeration Performance; Should Have Single Hand Operation With An Easy-To-Use Padlock-Compatible, Ergonomic Door Handle With Integrated Key Lock; Should Have Simplified Installation With Our New Easy Roll 2” Locking Casters; Should Have Four Infer Doors To Reduce Cold Air Loss And Improve Temperature Recovery After Door Openings, Should Have Microprocessor Control And Monitoring System To Ensure That All Controls And Displays Are Easy To Reach And Read; Should Have Power Management System With Low Voltage Surge Protection And Buck/Boost; Should Have Safety-Backup Systems For Additional Sample Protection In The Event Of Power Or Mechanical Failure.Should Have A Warranty Period Of At Least 3 Years And Should Include On-Site Installation And Training. , Minus 20°C Deep Freezer; Specifications: The Deep Freezer Should Be Horizontal Double Door Model With Minimum 600 Ltrs Capacity; Construction: I) Inner Chamber Should Be Fabricated From Ss316. Ii) Outer Construction Of Deep Freezer Should Be Of Ss304; Should Have Temperature Control System With Microprocessor Pid Control Auto Tune Ce Marked Controller Cum With Class A Sensor (Rtd); Temperature Range: I) Deep Freezer Should Be Designed For An Operating Temperature Range Of -18 °C To -22 °C Ii) Control Of Temperature Within 3 °Cof Set Temperature; Should Have An Evaporator Made Up Of Copper Coil With Fins For Generating Cooling In Working Area; Construction Of Doors: I) Main Door Should Be Double Walled With Ss 316 Stainless Steel Interior Lining With Sub Doors Ii) Sub Doors Should Be Made Up Of Ss 316 Stainless Steel Sheet Iii) Doors Should Have Triple Gasket System To Prevent Any Leakage Iv) Doors Should Have Polyurethane Insulation V) Doors Should Have Toggle Type Heavy Duty Hinges; Should Have Audio Alarm System, In Case Of I) High And Low Temperature Ii) Open Doors Iii) Power Failure.Should Have A Warranty Period Of At Least 3 Years And Should Include On-Site Installation And Training. , Bod Incubator; Specifications: Should Have A Temperature Range: -10 Deg C To +60 Deg C; Should Have A Temperature Uniformity Of +/- 0.1 Deg C; Should Have A Led Display; Should Have A Pid Temperature Control Device; Should Have Adjustable Shelves; Should Have A Volume Of 55-60 Litres ; Should Have Overheat Protection System.Should Have A Warranty Period Of At Least 3 Years And Should Include On-Site Installation And Training. , Elisa Reader; Specifications: Should Have Minimum Wavelength Range Of 400–750 Nm And Photometric Range Of 0.0–3.5 Od 2; Should Have Accuracy Of =1.0% At 490 Nm; Should Have Precision Of 1.0%; Should Have Minimum 8 Filter Wheel Capacity With 415, 450, 490, 595, 655, And 750 Nm Included Filters; Should Have Minimum 3 Speed Plate Shaking With Adjustable Duration Of 0–999 Sec; Should Have Five Measurement Modes Including End Point, Kinetic, Spectra, Kinetic Spectra And Multipoint; Should Have Read Time Should Not Be More Than 6 Sec At Single Wavelength Or 10 Sec At Dual Wavelengths; Should Have Usb Interface With Pc Or Mac Data Stations For Data Output; Should Be Able To Store Data For Assay Protocols; System Should Come With A Comprehensive Software Package Allowing Colorimetric And Turbidimetric Analyses, As Well As Report Analysis For Raw Data, Absorbance, Limit, Matrix, Normalization, And Curve Fit; Software Should Have The Functionality Of Flexible Template Creation; Software Should Be Either License Free Or License For Minimum 5 Systems Should Be Provided.Should Have A Warranty Period Of At Least 3 Years And Should Include On-Site Installation And Training. , Elisa Washer; Specifications: Should Be An Automatic Washer Compatible With Strips And 96-Well Microplates That Have Flat/U/V Bottom Wells; Should Have Programmable Needle Positions (Horizontal Or Vertical) To An Accuracy Of 0.1 Mm For Bottom Washing, Crosswise Aspiration, And Overflow Washing; Should Have Dispensing Speed Control; Should Have Plate Shaking Option To Help Minimize Bubbles And Adherence Of Liquid To Well Sides; Should Have Wash Bottle Sensor To Detect High Waste Liquid Levels; Should Have Up To 75 Programmable Washing Sequences; Should Have Easily Removable 8 Or 12 Way Manifolds; Should Have Removable And Autoclavable Plate Carrier; Should Have An Aerosol Protection Cover; Should Have Integrated Vacuum And Dispensing Pumps To Ensure Accurate And Quiet Washing And To Eliminate The Need For External Pumps; Should Have Soak Time In Strip Mode 0-9.9 Sec And In Plate Mode 0-59 Minutes; Should Have On-Board Software Capable Of Storing Up To 110 Wash Protocols; Should Have Operating Temperature Range Of 15-40°C; Should Have Dimensions (Wxdxh) Not More Than 35X43x20 Cm. Should Have A Warranty Period Of At Least 3 Years And Should Include On-Site Installation And Training. , Biosafety Cabinet; Specifications: Should Have A Size Not More Than 1200X780x2260mm; Should Have A Safety Height Opening Of Not More Than 8.2”; Should Have A Max Opening Of Not More Than 425 Mm; Should Have Hepa Filter With 99.9 % Efficiency At 0.3 Μm With Filter Life Indicator; Should Have Motorized Window With Laminated Glass And Anti-Uv Coating; Should Have Uv Lamp With Life Indicator; Should Have Led Lamp Illumination; Should Have Lcd Display Showing Uv Lamp Working Time, Inflow And Downflow Velocity, Temperature, Humidity, And Working Time. Should Have A Warranty Period Of At Least 3 Years And Should Include On-Site Installation And Training. , Gel Documentation System; Specifications: Should Have Option For Chemiluminescence, Fluorescence, And Digitization; Should Have Different Mode Of Operation (Standard/Programmed); Should Have Peltier Cooled Ccd Camera; The System Should Have Motorized Zoom Option; Should Have Uv And White Light Trans-Illuminator; The System Should Have Different Epi Light; The System Should Have Gfp Filter, Etbr Filter; Should Have Option For Automatic And Manual Exposure; Should Have Adjustable Manual Exposure Time; Should Have Option For Auto, Manual Focusing; Should Have Option For Brightness Control; Should Be Supplied With All The Accessories Required For Calibrating The Instrument; Should Have Sample Trays For Uv, White, Epi Light; The System Should Be Supplied With The Analysis Software; The System Should Have Option For 3D Imaging; The System Should Have Lcd Touch Display; The System Should Be Supplied With Necessary Pc Required For Image Analysis. Should Have A Warranty Period Of At Least 3 Years And Should Include On-Site Installation And Training.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Jul-2021 corrigendum Terms and Conditions 23-07-2021
2 19-Jul-2021 Equipment Specification change Other 23-07-2021

Key Value

Document Fees
INR 5000 /-
EMD
INR 650000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Supply of equipments for the ICMR NER-Task Force New Scheme entitled, “Advanced Molecular Diagnostic and Research Center”.
Sl. No. Item Description
1Equipments/Instruments for Microbiology Deptt. , Assam Medical College & Hospital, Dibrugarh, Assam
2Thermo Fisher Scientific, Phadia 200 (Proprietary item)
3Real-Time PCR; Specifications: An automated system for both PCR and post-PCR end-point analysis, using in-built Peltier based PCR machine; The system should support applications including absolute and relative quantitation, multiplex PCR allelic discrimination, melt curve analysis, pathogen detection and plus/ minus assays using an internal positive control; Peltier thermal cycling for Fast-PCR as well as Standard-PCR run available in the same block. 40 cycles in less than 30 minutes; The system should have temperature range of 3-99 degrees C with peak block ramp rate for heating as well as cooling exceeding 6 degrees C /second; Reaction volume should be approximately in the range of 5-100 µL; The system should support micro well plates, individual tubes and 8-tube strips; The system should provide Touch Screen LCD feature to avoid dependency on computer for operation; Should also be possible to use a computer for system control, operation, analysis and networking of multiple system; Instrument should be supplied with a separate Desktopalong with a standalone backup system capable of providing at least 90 minutes of backup time; USB port for data export to Power point, Excel or JPEG formats should be present; It should be an open system to use reagents from any manufacturer; System should be calibrated for common dyes of broader wavelength excitation and emission spectrum; Excitation Light source –Laser / LED; Change of position, block or chemistry should not require calibration or tools; The system should be capable of operating at ambient temperatures of 20-30 degrees C and relative humidity of 80%; Temperature gradient function should be available in the system; Temperature uniformity should be ±0.15 °C & control accuracy ± 0.1 °C; Temperature increments should be min. 0.1 °C/cycle & Time increments should be min. 1 s/cycle; It should have at least 5 Chanel multiplexingcapability in a single tube; Instrument should not require the use of a reference dye such as ROX and do not need regular calibration; Instrument should use a Fiber-Optic Shuttle System; It should do Scanning just above the sample & should guarantees the homogeneous excitation of each individual sample and the reliable recording of the emitted fluorescent signals with high sensitivity and no crosstalk between wells. Should have a warranty period of at least 1 year and should include on-site installation and training.
4Lyophilizer; Specifications: Should be fully automated, user friendly; Should have Seamless stainless-steel condenser; Should have a freeze drying area of 0.12 meter square, Should have 4 trays with 8 manifold port; Should have Compact design and operation- suitable for any Laboratory; Should have microprocessor control with alarm; Should have digital Temperature read out; Should have Faster drying rate and reproducible drying; Should have an air cooling system; Should have a cold trap temperature of <=56 deg C; Should have a cold trap capacity of 8-10 litres ; Should be capable of processing biological samples with diverse range of solvents; Vacuum pump specifications: Vacuum pump should be chemical resistant. The items such as vacuum hose, various filters for vacuum pump, drying chamber, rubber valves, etc which is necessary for the smooth operation of the instrument should be included; Accessories: All accessories with spare parts for immediate and smooth functioning of the system. Should have a warranty period of at least 3 years and should include on-site installation and training.
5HPLC Specifications: System pressure should have maximum pressure of 1500 bar; Should have a flow range of 0 to 5 mL per minute; Should have a binary pump options with default gradient delay volume; Should be biocompatible; Should have a pH range of 2–12 and a chloride concentration of up to 1 mol/L; Should have a modular design; Should have a solvent monitoring system; Should have a customizable gradient delay volume to simplify method transfer; Should have an injection volume range: Standard: 0.01-25 µL, Optional: 0.01-100 µL; Should have sample cooling range of 4-40°C; Should have a sample capacity (standard) of standard 12 mm OD vials (= 1.5 mL); Should have sampler extension; Should have column compartment thermostatting of 5-120 °C; Should have Column compartment pre-heater; Should have Column compartment post-column cooler; Should have the following Detectors: Charged Aerosol Detector, Diode Array Detector, Fluorescence Detector, Multiple Wavelength Detector, Variable Wavelength Detector, Mass Spectrometer.Should have a warranty period of at least 3 years and should include on-site installation and training.
6Refrigerated Centrifuge; Specifications: Compact refrigerated centrifuge with CFC free refrigerant; Should have max. speed of 16,500 rpm with an accuracy of +/-10 rpm; Should have ability to spin for a time of 1 min-99 hr 59 min, short and continuous run; The size should not be more than 422x628x362 (LxWxH) mm; Should provide a temperature range of -20 deg C to +40 deg C; Centrifuging chamber should be made of stainless steel with 3-layer; Should have powered lid locking; Should have quick and easy operation with the knob; The rotors should be changed easily; Should have Lid locking; Should have Emergency lid lock release function; Should provide imbalance and lid locking protection; Should have automatic rotor recognition; Should have atleast 40 levels of acceleration and deceleration.Should have a warranty period of at least 3 years.
7Centrifuge; Specifications: Should be a table top compact centrifuge; Should have max. capacity of not less than 8 x 15 ml; Should have max. speed of around 6,000 rpm with RCF of 3,461xg; Should have ability to spin for a time of 1 – 99 min, continuous run, short cycle mode (impulse key); The size should not be more than H x W x D: 22.8 x 26.1 x 35.3 cm; Centrifuging chamber should be made of stainless steel; Should have Viewing port in the lid; Should have powered lid locking; Should have Quick-entry foil keypad ; Should have Lid locking and holding function; Should have Emergency lid lock release function; Should provide Lid dropping protection; Should have Imbalance switch-off function; Should have a 8 place Fixed angle rotor for 15 ml tubes with speed: 6,000 rpm; Shouldalso provide fixed angle rotor for 50 ml tubes as optional.Should have a warranty period of atleast 3 years.
8Minus 80°C Deep Freezer; Specifications: Should have temperature control/display, temperature range: -50 °C to - 86°C; Capacity cu ft/liters: 350 or more; Cryo-box Capacity 2”:230 or more; Should have a max. shelf weight of 120lbs/65 kg or more; Should have Refrigeration HP: Two 1.25 HP each; Should have voltage: 230V, 50/60 Hz; Should have heavy gauge, cold rolled steel cabinets with a powder coat paint finish for a uniform exterior that resists chipping and rust; Should have 5” (12.7 cm) foamed-in-place polyurethane insulation; Should have vacuum relief port for easy access after door openings; Should have easy to remove washable filter for protection from dust on the condenser and increasing refrigeration performance; Should have single hand operation with an easy-to-use padlock-compatible, ergonomic door handle with integrated key lock; Should have simplified installation with our new easy roll 2” locking casters; Should have four infer doors to reduce cold air loss and improve temperature recovery after door openings, Should have microprocessor control and monitoring system to ensure that all controls and displays are easy to reach and read; Should have power management system with low voltage surge protection and buck/boost; Should have safety-backup systems for additional sample protection in the event of power or mechanical failure.Should have a warranty period of at least 3 years and should include on-site installation and training.
9Minus 20°C Deep Freezer; Specifications: The deep freezer should be horizontal double door model with minimum 600 Ltrs capacity; Construction: i) Inner chamber should be fabricated from SS316. ii) Outer construction of deep freezer should be of SS304; Should have Temperature control system with microprocessor PID control AUTO TUNE CE marked controller cum with class A sensor (RTD); Temperature range: i) Deep freezer should be designed for an operating temperature range of -18 °C to -22 °C ii) Control of temperature within 3 °Cof set temperature; Should have an evaporator made up of copper coil with fins for generating cooling in working area; Construction of doors: i) Main door should be double walled with SS 316 stainless steel interior lining with sub doors ii) Sub doors should be made up of SS 316 stainless steel sheet iii) Doors should have triple gasket system to prevent any leakage iv) Doors should have polyurethane insulation v) Doors should have toggle type heavy duty hinges; Should have Audio Alarm System, in case of i) high and low temperature ii) open doors iii) Power failure.Should have a warranty period of at least 3 years and should include on-site installation and training.
10BOD Incubator; Specifications: Should have a temperature range: -10 deg C to +60 deg C; Should have a temperature uniformity of +/- 0.1 deg C; Should have a LED display; Should have a PID temperature control device; Should have adjustable shelves; Should have a volume of 55-60 litres ; Should have overheat protection system.Should have a warranty period of at least 3 years and should include on-site installation and training.
11ELISA Reader; Specifications: Should have minimum wavelength range of 400–750 nm and photometric range of 0.0–3.5 OD 2; Should have accuracy of =1.0% at 490 nm; Should have precision of 1.0%; Should have minimum 8 filter wheel capacity with 415, 450, 490, 595, 655, and 750 nm included filters; Should have minimum 3 speed plate shaking with adjustable duration of 0–999 sec; Should have five measurement modes including end point, kinetic, spectra, kinetic spectra and multipoint; Should have Read time should not be more than 6 sec at single wavelength or 10 sec at dual wavelengths; Should have USB interface with PC or Mac data stations for data output; Should be able to store data for assay protocols; System should come with a comprehensive software package allowing colorimetric and turbidimetric analyses, as well as report analysis for raw data, absorbance, limit, matrix, normalization, and curve fit; Software should have the functionality of flexible template creation; Software should be either license free or license for minimum 5 systems should be provided.Should have a warranty period of at least 3 years and should include on-site installation and training.
12ELISA Washer; Specifications: Should be an automatic washer compatible with strips and 96-well microplates that have flat/U/V bottom wells; Should have programmable needle positions (horizontal or vertical) to an accuracy of 0.1 mm for bottom washing, crosswise aspiration, and overflow washing; Should have Dispensing speed control; Should have plate shaking option to help minimize bubbles and adherence of liquid to well sides; Should have wash bottle sensor to detect high waste liquid levels; Should have up to 75 programmable washing sequences; Should have easily removable 8 or 12 way manifolds; Should have removable and autoclavable plate carrier; Should have an aerosol protection cover; Should have integrated vacuum and dispensing pumps to ensure accurate and quiet washing and to eliminate the need for external pumps; Should have soak time in strip mode 0-9.9 sec and in plate mode 0-59 minutes; Should have on-board software capable of storing up to 110 wash protocols; Should have operating temperature range of 15-40°C; Should have dimensions (WxDxH) not more than 35x43x20 cm. Should have a warranty period of at least 3 years and should include on-site installation and training.
13Biosafety cabinet; Specifications: Should have a size not more than 1200x780x2260mm; Should have a safety height opening of not more than 8.2”; Should have a max opening of not more than 425 mm; Should have HEPA Filter with 99.9 % efficiency at 0.3 µm with filter life indicator; Should have motorized window with laminated glass and Anti-UV coating; Should have UV lamp with life indicator; Should have LED lamp illumination; Should have LCD display showing UV lamp working time, inflow and downflow velocity, temperature, humidity, and working time. Should have a warranty period of at least 3 years and should include on-site installation and training.
14Gel Documentation System; Specifications: Should have option for chemiluminescence, fluorescence, and digitization; Should have different mode of operation (standard/programmed); Should have Peltier cooled CCD camera; The system should have Motorized zoom option; Should have UV and white light trans-illuminator; The system should have different Epi light; The system should have GFP filter, Etbr filter; Should have option for automatic and manual exposure; Should have adjustable manual exposure time; Should have option for auto, manual focusing; Should have option for brightness control; Should be supplied with all the accessories required for calibrating the instrument; Should have sample trays for UV, white, Epi light; The system should be supplied with the analysis software; The system should have option for 3d imaging; The system should have LCD touch display; The system should be supplied with necessary PC required for image analysis. Should have a warranty period of at least 3 years and should include on-site installation and training.