Certain B R Repair Internal Electrification Work To Otm Accn Of Certain Units At Bhagat Marg Includind Repair Replacement Of Ac Sheet Roof/Ceiling In The Aor Of Age B R Ii Under Ge Narangi . , GE NARANGI-Assam

Military Engineer Services-MES has published Certain B R Repair Internal Electrification Work To Otm Accn Of Certain Units At Bhagat Marg Includind Repair Replacement Of Ac Sheet Roof/Ceiling In The Aor Of Age B R Ii Under Ge Narangi . . Submission Date for this Tender is 30-07-2021. Electrification Work Tenders in GE NARANGI Assam. Bidders can get complete Tender details and download the document.




Tender Notice

28397415
Corrigendum : Certain B R Repair Internal Electrification Work To Otm Accn Of Certain Units At Bhagat Marg Includind Repair Replacement Of Ac Sheet Roof/Ceiling In The Aor Of Age B R Ii Under Ge Narangi .
Open Tender
Indian
Assam
GE NARANGI
30-07-2021

Tender Details

Certain B R Repair Internal Electrification Work To Otm Accn Of Certain Units At Bhagat Marg Includind Repair Replacement Of Ac Sheet Roof/Ceiling In The Aor Of Age B R Ii Under Ge Narangi .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Jul-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-07-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : CERTAIN B/R REPAIR, INTERNAL ELECTRIFICATION WORK TO OTM ACCN OF CERTAIN UNITS AT BHAGAT MARG INCLUDIND REPAIR/ REPLACEMENT OF AC SHEET ROOF/CEILING IN THE AOR OF AGE B/R-II UNDER GE NARANGI.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., complete all as specified and as directed. 87 Sqm
2 2 S&F 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugation side lap, fixed with 'L' type or 'J' type or cranked hook bolts and washers, in roof covering, walls cladding etc, with grade of zinc coating 275 complete all as specified and as directed. 60 Sqm
3 3 Refixing only galvanised corrugated mild steel sheeting as obtained from dismantling of old sheets here in before with two corrugation side lap, fixed with & including 'L' type or 'J' type or cranked hook bolts in roof covering, wall cladding etc., complete all as specified and as directed. 10 Sqm
4 4 S&F 0.63 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed. 5 Sqm
5 5 Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed. 1633 Sqm
6 6 M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and directed. 1480 Sqm
7 7 M&L Pre- painted hot dip aluminium Zinc alloy metalic coated plain steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws as specified complete all as specified and directed. Note: To be executed for provision of ridges and hips. 132 Sqm
8 8 S&F 6 mm thick asbestos cement corrugated or semi corrugated sheet with side lap, fixed with 'L' or 'J' type or cranked hook bolts, nuts & washers etc.complete all as specified and as directed. 20 Sqm
9 9 Refixing only asbestos cement corrugated or semi corrugated sheet as obtained from dismantling of old sheets with side lap, fixed with 'L' or 'J' type or cranked hook bolts, nuts and washers complete all as specified and as directed. 10 Sqm
10 10 S&F 6 mm thick asbestos cement two piece adjustable serrated ridge, for corrugated or semi corrugated sheet fixed with 'L' or 'J' type or cranked hook bolts, nuts & washers complete all as specified and directed. 5 Rm
11 11 S&F in repairs, suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid complete all as specified and as directed. 145 Sqm
12 12 M & L for 4 mm thick non Asbestos fibre cement building boards fixed or laid / inserted to timber / GI / Aluminium framework with screws including taking out old unserviceable boards complete all as specified and as directed. 9 Sqm
13 13 Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cm thick ( Below or above ground) complete all as specified and directed. 3.75 Cum
14 14 M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed. 50 Sqm
15 15 M & L for 75 mm thick PCC 1:2:4, type B2 using (40 mm graded stone aggregate) as in floors/ hard standing/path etc complete all as specified and as directed. 50 Sqm
16 16 Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. 8 Cum
17 17 M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. 6 Cum
18 18 All as per item No 17 here in before but except bricks. Note: Old serviceable bricks as obtained from demolition here-in-before shall be reused under this item complete all as specified and as directed. 0.5 Cum
19 19 M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. 13 Sqm
20 20 Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. 100 Sqm
21 21 M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed 55 Sqm
22 22 M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. \n 130 Sqm
23 23 M&L for preparation of new plastered surface of walls and applying three coats of white wash complete all as specified and as directed. 10 Sqm
24 24 M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed. 55 Sqm
25 25 M&L for preparation of new plastered surface of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed. 30 Sqm
26 26 M & L for preparation of newly plastered surfaces of walls and applying one coat of alkali resistant primer over a coat of 1 mm thick (average) white cement putty, sanding the surfaces till smooth finish is obtained and finally applying two coats of oil emulsion distemper complete all specified and as directed 25 Sqm
27 27 M&L for complete removal of old treated surfaces on walls and applying one coat of alkali resistant primer and a coat of wall care putty, sanding the surfaces till smooth finish is obtained and finally applying two coats of cement based paint complete all as specified and directed. 75 Sqm
28 28 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed. 4.4 Qtl
29 29 M & L for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to grade Fe-410-W (Gde E 250) for fixing complete all as specified and as directed. 300 Kg
30 30 M & L for rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1998 grade St.-240 complete all as specified and as directed. 40 Kg
31 31 S & F mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe 290, Gde-E-165 complete all as specified and as directed. 100 Kg
32 32 M&L for mild steel flat iron hold fasts, fixed to chowkats confirming to Fe-290 Gde-E-165 etc, complete including taking out old unserviceable hold fast all as specified and as directed. 1 Kg
33 33 M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. 37 Sqm
34 34 Dismantling timber scantling 40Sqcm and over in section as in unframed work in any position complete all as specified and as directed. 1.7 Cum
35 35 M&L for 2nd class hard wood, in scantlings, clean sawn timber as in unframed work complete all as specified and as directed. 1.7 Cum
36 36 M&L for prelaminated particle board 12mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to timber frame work complete all as specified and as directed. 1 Sqm
37 37 M & L for 2nd class hardwood, weather boarding, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30mm laps including dismantling of old boarding complete all as specified and as directed. 40 Sqm
38 38 Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each including builders hardware complete all as specified and as directed. 15 Each
39 39 Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5 Sqm but not exceeding 4 Sqm each including builders hardware complete all as specified and as directed. 15 Each
40 40 Taking down shutter of any description n exc 1 Sqm each complete all as specified and as directed. 10 Per \nLeaf
41 41 Taking down shutter of any description exc 1 Sqm but n exc 2 Sqm each complete all as specified and directed. 10 Per \nLeaf
42 42 M&L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. 1 Cum
43 43 M&L for 1.25mm thick pressed steel frames of size 105x60mm for doors with single rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed. 15 Rm
44 44 M & L for PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) as in back filling in pressed steel door and window frame or hold fast complete all as specified and as directed. 0.5 Cum
45 45 S&F 30mm thick flush shutter, solid core construction with particle board core and plywood face panel, commercial type on both side complete all as specified and directed. 42 Sqm
46 46 S&F 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc with plain, chamfered or rounded, mitred beads (without sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (a) complete all as specified and directed. 10 Sqm
47 47 S&F 30mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc with plain, chamfered or rounded, mitred beads (with sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (b) complete all as specified and directed. 15 Sqm
48 48 M & L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed. 134 Sqm
49 49 M & L for preparation of surfaces of wood and wood based surfaces new or old of any description and girth not otherwise described and treating with two coats of creosote oil complete all as specified and as directed. 40 Sqm
50 50 S & F factory made solid PVC door frame of size 40mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. 23.75 Rm
51 51 S & F factory made solid PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specfication, drawing and complete all as specified and as directed. 7.5 Sqm
52 52 S & F factory made steel windows with side hung shutters glazed shutter including both side openable (out side glazed window and inside fly proof window) including projecting type hinges with steel handle and steel peg stay complete with glazing bars and 12 mm square bar or round bar of approved design welded to steel window frame dovetailed or welded complete all as specified and directed . Note: Guard bar or square bar shall be measure and paid separately. 6 Sqm
53 53 M & L for Anodized aluminium sliding glazed window, shutter (double leaf glazed shutter and single leaf mosquito proof shutter each in single frame work) without sash bars with anodized aluminium shutter of section 40.00 mm x 20.00 mm x 1.10 mm thick and window chowkat of section 92.00 mm x 29.50 mm x 1.20 mm thick including necessary jointing cleats, glazing clips, rubber packing, snap beading, screws, handle, tower bolts and locking arrangement etc. and 4 mm thick sheet glass, tinted quality on panel and aluminium anodized wire cloth for mosquito proofing, 0.45 mm nominal dia and average width of aperture 1.40 mm fixed with aluminium screws and tacks and making good to disturbed surfaces complete all as specified and as directed. 2.8 Sqm
54 54 M&L for anodized aluminium push pull type partly panelled and partly glazed door shutter (single leaf / double leaf) having top rail of section 85.00mm×44.45mm×2.00mm, bottom rail of section 85.00mm×44.45mm×2.00mm thick, door verticals of section 44.45mm×44.45mm×2.00mm thick and lock rail of section 85.00 mm× 44.45mmx2.00mm thick with aluminium anodized frame of section 63.50mm x 33.10mmx2.50mm thick including necessary jointing cleats, glazing clips, rubber packing snap beading, screws, handle and locking arrangements etc, including 12mm thick pre laminated particle board, interior grade pre laminated with decorative face laminations both sides on bottom panel and 5.5 mm thick float glass tinted quality on top panel and including 1 No of aluminium door closer per leaf (Diecast) body hydraulically regulated designation No 3 universal type complete all as specified and as directed. \n 4.2 Sqm
55 55 S&F cold rolled stainless steel butt hinges 100 mm long medium weight complete all as specified and as directed. 105 Each
56 56 S&F cold rolled stainless steel butt hinges 75 mm long medium weight complete all as specified and as directed. 40 Each
57 57 S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. 56 Each
58 58 S&F 100 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed. 30 Each
59 59 S & F 150 mm in size extruded aluminium handles, fabricated type, anodised complete all as specified and as directed. 56 Each
60 60 S &F 100 mm in size extruded aluminium handles, fabricated type, anodised complete all as specified and as directed. 30 Sqm
61 61 S & F 300 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified and as directed. 23 Each
62 62 S & F stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. 5 Sqm
63 63 S & F in repairs, stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. 5 Sqm
64 64 S&F in repairs, aluminium (extruded section) body door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed. 5 Each
65 65 S&F in repairs, double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box main body with stainless steel cover, pivot made of brass, other parts made of mild steel complete all as specified and as directed. 1 Each
66 66 S & F in repairs, Brass locking arrangement with two levers of aproved make mortice lock for fixing to wooden / aluminum shutters complete all as specified and directed. 2 Each
67 67 Hacking out old broken glass (any thickness, quality or description) from wooden/steel frame or stone concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed. 9.5 Sqm
68 68 S & F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed. 13.5 Sqm
69 69 S&F 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and as directed. 1 Sqm
70 70 Dismantling floor, hearth and wall tiling including cement mortar bedding (but excluding backing), removing rubbish off the premises complete all as directed. 100 Sqm
71 71 M & L for coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. 20 Sqm
72 72 M & L for vitrified ceramic tiles, light shade, 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. 50 Sqm
73 73 M & L for glazed ceramic tiles of size 300 mm x 200 mm x 6 to 7 mm thick coloured on vertical surfaces set, jointed in neat cement slurry and pointed in white cement mixed with colour pigments to match the colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as speciified and drected. 30 Sqm
74 74 M&L for pre polished chequered cement concrete tiles in floor, area exc 0.06 Sqm but not exc 0.11 Sqm, 25 mm thick with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with colour pigment to match with the tiles over and including screed bed of 20 mm thick cement mortar (1:4) including dismantling of old tiles of any description complete all as specified and as directed. 50 Sqm
75 75 Taking up or down 15 mm bore GI water tubing and connections including cleaning for re-fixing to store complete all as specified and as directed. 10 Rm
76 76 S & F GI tubing15 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. 9 Rm
77 77 Refixing only old serviceable 15 mm bore Steel tubing and connections as obtained from taking up/down old steel tubing including provision of new fittings in new or old position to walls,ceiling, flooring etc. complete all as specified and as directed. 1 Rm
78 78 Taking up or down 20 mm bore GI water tubing and connections including cleaning for re-fixing to store complete all as specified and as directed. 30 Rm
79 79 S & F GI tubing 20 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. 28 Rm
80 80 Refixing only old serviceable 20 mm bore Steel tubing and connections as obtained from taking up/down old steel tubing including provision of new fittings in new or old position to walls,ceiling, flooring etc. complete all as specified and as directed. 2 Rm
81 81 S&F in repairs, bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed. 5 Each
82 82 S&F in repairs, 15mm bore pillar taps, cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed. 5 Each
83 83 S&F in repairs, stop valves/ angular stop valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directe. 5 Each
84 84 S&F in repair, 15mm bore dia of conceled stop valves cast copper alloy fancy type chromium plated with long shank and cup complete all as specified and as directed. 2 Each
85 85 S & F in repairs, 125 mm, dia chromium plated, swivel type shower rose with 190 mm long chromium plated shower arm and wall flange suitable for fixing 15 mm bore iron pipe complete all as specified and as directed. 3 Each
86 86 S&F in repairs 600mmx450mm beveled edge mirror of selected quality glass, mounted on 6mm thick commercial plywood with aluminium frame fixed with rubber gaskets and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed 1 Each
87 87 S & F in repairs, 10 Litres capacity PVC valveless syphonic action type, flushing cistern, low level, white or coloured, with inlet, ball valve, float and handle including brackets etc complete all as specified and as directed. 4 Each
88 88 S & F in repairs, PVC connection pipe 15mm bore and 600mm long with PVC PTMT nuts at each ends with rubber washers complete all as specified and directed. 4 Each
89 89 S & F 500 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc including dismantling of old tank of any description complete all as specified and as directed. 5 Each
90 90 S & F 1000 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including dismantling of old tank of any description complete all as specified and as directed. 3 Each
91 91 Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes etc of capacity exc 500 litre but not exc 1000 litre capacity tank and writing the date of cleaning on water tank with white paint complete all as specified and as directed. 5 Each
92 92 S&F in repair 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and as directed.\n 5 Each
93 93 S & F in repairs sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortat to dwarf wall or including fixing cantiliver brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and as directed. 1 Each
94 94 S & F in repairs, vitreous china, wash hand basin, white, flat back size 550 mm x 400 mm including brackets including pillar tap, 15 mm bore chromium plated, cast copper alloy with capstan heads, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts and PVC waste pipe,15mm dia PVC connection pipe complete all as specified and as directed 2 Each
95 95 S & F in repairs, Vitreous China Squatting Pan"Orissa pattern" size 580 mmx440 mm white with integral foot rest etc. ( excluding cistern and flush pipe) including S or P Trap and provision of concrete bedding and making good to floor complete all as specified and as directed. 1 Each
96 96 S & F in repairs, vitreous china wash down water closet (pedestal pattern) including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, trap set and including white or black seat cover for pedestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws etc complete all as specified and as directed 1 Each
97 97 S & F in repairs, Vitreous china urinal, half stall white (excluding flushing cisterrn) including urinal spreader, PVC connection, 40 mm PVC waste pipe & 40 mm waste coupling providing and fixing plugs, bedding urinal against wall in mortar 1:2, securing urinal to plug, with and including 60 mm long screws, pointing around urinal back in cement, fixing flush pipe, grating and union for discharge pipe complete all as specified and as directed. 1 Each
98 98 S&F in repairs, 32 mm dia PTMT waste coupling (half or full thread) complete all as specified and as directed.\n 2 Each
99 99 S&F in repairs, 40 mm dia PTMT waste coupling (half or full thread) complete all as specified and as directed. 2 Each
100 100 S & F in repairs, plastic water closet seat cover, black or white, closed pattern with flat bottom, and cover including mild steel chromium plated or aluminised hinging device complete all as specified and as directed. 1 Each
101 101 S & F in repairs, 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches or in floor complete all as specified and as directed.\nNote : Excavtion & Earth work is deemed to be included in quoted rate. 6 Rm
102 102 S & F 110 mm dia PVC (SWR) bends of any radius complete all as specified and as directed. 2 Each
103 103 Taking down carefully aluminium/ copper point wiring for light/fan/ socket/bell or power point incl. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. complete removing materials to store for keeping in safe custody site or handed over to contractor as schedule of credit and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge. 545 Per Point
104 104 Point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC Casing and Caping with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One light or fan point controlled by one 5 Amps switch one way complete all as directed. 300 Per\nPoint
105 105 All as per item No 104 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board 60 Per\nPoint
106 106 All as per item serial No104 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches. 60 Per\nPoint
107 107 All as per item No 104 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly. 60 Per\nPoint
108 108 M&L point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in concealed conduit including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One light or fan point controlled by one 5 Amps switch one way complete all as specified and directed. 50 Per Point
109 109 All same as per item No 108 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board. 5 Per Point
110 110 All same as per item No 108 here-in-before but for One 3 pin 5 Amp switch socket outlet on same board with other switches. 5 Per Point
111 111 All same as per item No 108 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly. 5 Per Point
112 112 S&F switch piano, flush type single pole one way 5 Amps 230 volt complete all as directed. 415 Each
113 113 S&F socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as directed. 65 Each
114 114 S&F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as directed. 65 Each
115 115 S&F switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as directed. 65 Each
116 116 S&F ceiling rose surface bakelite 65x50mm three terminal complete all as directed. 270 Each
117 117 S&F lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as directed 80 Each
118 118 S&F stepped type electronic fan regulator, two module size, flush type complete all as directed. 120 Each
119 119 S&F in repairs, regal batten for LED Tube rod pre-wired including LED tube double sided 1x20W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable & fix on 2 no. of PVC block complete all as directed. \n(Make:- Havells, Model-REGALBATTENT8UPTO1X22WDSBSWH+CRSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Bajaj/ Philips /GE/Crompton) 150 Each\n
120 120 S&F in repairs, LED box type fitting pre-wired including LED tube 1x10W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable and fix on 2 no of PVC block complete all as directed. \nMake:- Jaguar Model-LGLZ01X010XC/ LGLZ01X010XN/LGLZ01X010XW or Make:- Havells Model-LUMILINEPLUSBS10WLED865SPCSS or equivalent model of make Philips /GE/Cromptonor equivalent model of make Philips /GE/Crompton 10 Each\n
121 121 S&F in repairs LED (double sided connection) ) ultra bright polycarbonate tube light 18/20 watt retrofit in existing flourescent tube light . Make Havells/crompton/Bajaj/Jaquar or euivalent. 45 Each
122 122 S&F in repairs wall mounted decorative luminaire in design mesh suitable for 9W LED lamp B22 base ,including lamp 15watt complete all as specified and as directed. \nMake -Havells, cat no-LHDL07150099 or equivalent in crompton, Bajaj, Jaquar 10 Each
123 123 S&F in repairs Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed.\nMake:- Havells Model HEXAFT10WLED857SSYMBOPC or equivalent\nModel of make : Philips / Crompton /GE. 40 Each
124 124 S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed.\nMake :- Legrand Cat No 5076 11 or equivalent \nmodel in Siemens / Schneider\n 20 Each
125 125 S&F in repairs, MCBs, SPN 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.\nMake :- Legrand Model 4086 09 to 17 or equivalent model in Siemens / Schneider/L&T 30 Each
126 126 S&F in repairs, MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.\nMake :- Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T 120 Each
127 127 M&L for Sub main wiring with 2 runs of 1.5 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 1.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. \n(Note: 2 run of 1.5 Sqmm cable and 1 run of 1.5 Sqmm cable along with conduit all together shall be measured as one unit.) 150 Rm
128 128 M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. \n(Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit all together shall be measured as one unit.) 250 Rm
129 129 M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. \n(Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit all together shall be measured as one unit.) 100 Rm
130 130 M&L for Sub main wiring with 2 runs of 10.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. \n(Note: 2 run of 10 Sqmm cable and 1 run of 10 Sqmm cable along with conduit all together shall be measured as one unit.) 100 Rm
Disclaimer :