| 1 | 1 | Taking out existing unseviceable AC of capacity 1.5/2 Ton split ype unit by carefully disconnecting existing electrical connection, removing aside, packing and servicing after proper cleaning checking of all electrical connectioin, checking for leakage etc if any complete all as directed by Engineer-in-charge. | | 20 | Each |
|---|
| 2 | 2 | Taking out unserviceable wiring for AC 1.5/2 Ton capacity split type and rewiring with suitable copper wire and testing complete all as directed by Engineer-in-Charge. | | 20 | Each |
|---|
| 3 | 3 | Taking down unserviceable strainer and replace by new one of following split type AC. | | | |
|---|
| 4 | 3.01 | 1.5 Ton capacity | | 15 | Each |
|---|
| 5 | 3.02 | 2.0 Ton capacity | | 17 | Each |
|---|
| 6 | 4 | Supply and fixing of drain out PVC pipe 1/2\" to 1\" dia with clamps of approved size after taking out old drainpipe of 150/80 ltrs capacity water cooler complete all as specified and directed. | | 6 | Each |
|---|
| 7 | 5 | Taking out water storage tank carefully from the system soldering to the water tank to prevent water leakage and re-fixing the water tank inside the cooler for 150/80 ltrs capacity water cooler. | | 5 | Each |
|---|
| 8 | 6 | S&F in repair of the internal electrical circuit by flexible copper insulated conductor of suitgable size with thimbles sockets etc complete all as required at site for water coolers 80 ltrs capacity. | | 3 | Each job |
|---|
| 9 | 7 | S & F of lid gasket set (top & bottom) of required size suitable for 80 ltrs cpacity water coolers after taking out worn out gasket set complete all as specified and directed. | | 2 | Set |
|---|
| 10 | 8 | Installation of water coolers after repair including connecting to water supply system and electrical system properly testing for coolihg auto cut ON/OFF of the system sound less working system vibration proof for complete all as specified and directed. | | 5 | Each job |
|---|
| 11 | 9 | M&L for re-insulation with glass wool/thermocol to pre-cast the water tank from external heat as required at site for water coolers of any size and capacity complete all as specified and directed. | | | |
|---|
| 12 | 9.01 | Thermocol | | 3 | Each Job |
|---|
| 13 | 9.02 | Glass wool | | 3 | Each Job |
|---|
| 14 | 10 | Servicing/cleaning, taking out water cooler from the existing places, clearing with blower and soap water solution making dust free to the system tightening all nuts bolts screws etc oiling to blower motor refixing the water cooler in existing places properly to make sure that there is no extra sound from water cooler. | | 6 | Each |
|---|
| 15 | 11 | Disconnecting the refrigerators from the system for servicing/cleaning, taking out regrigerators form the existing places, clearing with blower and soap water solution making dust free to the system tightening all nuts bolts screws etc, refixing the refrigerators in existing places properly to make sure that there is no extra sound from refrigerators. | | 5 | Each |
|---|
| 16 | 12 | S & F of cooling coil complete for refrigerators of different make for the capacities 165/180/300 ltr capacity after taking out old unserviceable cooling coil complete all as specified and directed. | | 3 | Each |
|---|
| 17 | 13 | S&F of suitable size chill tray for refrigerator of 165/180/300 ltr capacity after taking out old chill tray complete all as specified and directed. | | 4 | Each |
|---|
| 18 | 14 | S&F of door gasket for refrigerator after taking out old unserviceable door gasket set complete all as specified and directed. | | 3 | Each |
|---|
| 19 | 15 | S&F of plug top 15 Amps capacity. | | 11 | Each |
|---|
| 20 | 16 | S&F PVC stand for refrigerator 165/180/300 ltr capacity. | | 4 | Each |
|---|
| 21 | 17 | S&F of freezer door for 165/180/300 ltr capacity refrigerator. | | 3 | Each |
|---|
| 22 | 18 | S&F vegetable tray 165/180/300 ltr capacity refrigerator. | | 3 | Each |
|---|
| 23 | 19 | Disconnecting electrical connection and dismantling/ taking out indoor and out door unit of split type air conditioning of any make and capacity from any place and installation, commissioning and testing to another location including transportation from existing bldg to another bldg and full functning of air conditionercomplete all as specified and directed. Note:-spare parts shall be measured sepratelly if required. | | 3 | Each Job |
|---|
| 24 | 20 | Supply & replacement of copper tubing including cutting brazing, flaring and testing of size 1x4”x22SWG in required length including insulating piping complete all as specified and directed. | | 35 | RM |
|---|
| 25 | 21 | Supply and replacement of Fan Motor 1/10 H.P Single phase, 230V for water cooler. Make: GE Motors / Air Master/C&G | | 3 | Each |
|---|
| 26 | 22 | Supply and replacement of Fan blade of water cooler as per sample etc complete all as specified and directed. | | 3 | Each |
|---|
| 27 | 23 | Supply and replacement of Thermostate for water cooler complete all as specified and directed. Make : Denfoss/indfoss | | 3 | Each |
|---|
| 28 | 24 | Supply and replacement of Push type C.P. cock for water cooler Make: L & K/Leader/sona/Ess-Ess. | | 3 | Each |
|---|
| 29 | 25 | S&F in replacement of float valve 15mm dia PVC with float complete all as specified and directed. | | 5 | Each |
|---|
| 30 | 26 | Supply and replacemant of water drain-out tary stainless-Steel (thicknees - 0.71) for water cooler any make /size , with PVC waste pipe, pipe clamp, complete all as specified and directed. | | 4 | Each Job |
|---|
| 31 | 27 | Taking out unserviceable compressor from refrigerator of capacity 165 to 310 ltr of any make by un-screwing from base plate after disconnecting all electrical and suction / discharge pipe connections complete and fixing compressor (sealed unit) and providing all electrical connections to respective terminals including changing of unserviceable connecting wires as per the existing. Brazing of suction and discharge lines with new compressor and vacuuming the system and testing / rectification of leakage supply and charging of refrigerant gas as per requirement to achieve proper cooling effect and testing on completion complete all as specified and as directed. \nNote : (i) Compressor (sealed unit) shall be measured and paid separately (ii) Gas and Parts required for replacement for satisfactory repair shall be paid and measured separately. | | 6 | Each |
|---|
| 32 | 28 | Labor only for Gas Charging of Refrigerator 165 Ltr to 310 Ltr capacity including necessary R-22/134 gas, filter, anti moisturising agent, soldering/brazing, necessary copper capillary tube any size and testing complete all as specified and directed. Note: Refrigrant gas will be paid and measured separately. | | 5 | Each |
|---|
| 33 | 29 | Supply and replacement of compressor (sealed unit) with relay suitable for refrigerator of capacity 200 to 280 ltrs complete all as specified and as directed by Engineer-in-Charge. Make: KIRLOSKAR /GODREJ/Blue Star/Voltas/Carrier/Samsung) | | 2 | Each |
|---|
| 34 | 30 | All as per item No. 29 above but for capacity of 165/175 ltrs capacity. | | 2 | Each |
|---|
| 35 | 31 | Supply and replacement of Thermostatic switch with knob suitable for Refrigerator. Make: Indfoss / Ranutrol. | | 6 | Each |
|---|
| 36 | 32 | Supply and replacement of over load protector relay suitable refrigerator any capacity. Make: Sriram/ Ranutrol/ Indfoss.\n \n | | 4 | Each |
|---|
| 37 | 33 | Removing rusted worn out bottom base portion of refrigerator/deep freezer of any size and supplying and fixing including welding and making the surface as original along with painting with one coat of red oxide primer and two coats of super synthetic enamel paint matching to the original colour of refrigerator complete all as specified and directed. | | 2 | Each |
|---|
| 38 | 34 | Labour only for attending day to day complaints pertains to split/ window type air conditioners any capacity, Refrigerators, water coolers, and voltage stabilizers etc as and when required , for checking the equipment at existing location and find out the faults/ defects and rectify the defects in site including rectified electric fault from existing DBs to functional box ,.and cleaning / normal maintenance to the equipments complete to make the equipment functional in all respect all as directed. Complaint shell be collected from site-in-charge (JE) on daily basis. Complaint shell be attended within 24 hrs of compliant lodged, If complaint is not attended in the specified time period panalty shell be charged to the contractor @ Rs 500/per day/complant. Note: Spare parts required will be measured and paid separetly. | | 50 | Each Job |
|---|
| 39 | 35 | M&L for servicing of Split/window type air conditioner of capacity 1.5/2.0 Ton of any make and type by replacing unserviceable compressor and other parts from the machine including charging of refrigerant gas after vacuming and leak testing, Brazing the suction / discharge tubes where required and changing of wiring with proper size PVC insulated wires as directed.by Replacing Air Filter,Oiling of Blower,Condensor Fan Motors ,replacement of Bushes 2 Nos for fan motor ,cleaning of condensor coil by high pressure water & cleaning liquid, complete as directed .Install the Air conditioner at location where directed after proper repair and testing complete at site as per the satisfaction of Engineer-in-Charge. Note : (i) Replacement of compressor shall be measured and paid separately under relevant item given here-in-after . (ii) Spare Parts required for replacement for satisfactory repair shall be measured separately under appropriate items given here-in-after. (iii) Gas will be measured and paid separately. | | 10 | Each |
|---|
| 40 | 36 | S&F in replacement of compressor (sealed unit) of capacity 1.5 Ton in replacement of unserviceable one including installation 1.5 Ton capacity Split/window type air conditioner etc. complete all as specified and directed. Make: Carrier/Blue Star/Voltas/Samsung. | | 7 | Each |
|---|
| 41 | 37 | S&F in replacement of compressor (sealed unit) of capacit 2.0 Ton in replacement of unserviceable one including installation 2.0 Ton capacity Split/window type air conditioner etc. complete all as specified and directed. Make: Carrier/Blue Star/Voltas/Samsung. | | 6 | Each |
|---|
| 42 | 38 | Supply and replacement of Running capacitor 36 MFD 230 volts, 50 Hz. Make: KELTRON / USHA / SIEMENS/Sarda. | | 6 | Each |
|---|
| 43 | 39 | Supply and replacement of Starting capacitor 100 to 120 MFD 230 volts, 50 Hz. Make: KELTRON / USHA / SIEMENS/Sarda. | | 5 | Each |
|---|
| 44 | 40 | S&F in replacement running capacitor 50+6 MFD suitable for 2.0 ton Air Conditioner split type complete all as specified and directed. Make: USHA/ SIEMENS/ Keltron/ Sarda. | | 12 | Each |
|---|
| 45 | 41 | S&F in replacement of Blower Motor, single phase 230 Volts 1300 RPM, with fins suitable for in door unit 1.5/2.0 TR Split type Air Conditioner as per sample. Make: AUE / USHA. | | 7 | Each |
|---|
| 46 | 42 | Supply and filling gas Mafron-22 in sealed cylinders. Note: Empty cylinders shall be return after use. | | 50 | Kg |
|---|
| 47 | 43 | Supply and filling gas Mafron-134-A, in sealed cylinder. Note: Empty cylinders shall be return after use. | | 10 | Kg |
|---|
| 48 | 44 | Supply and replacement of old unserviceable remote control kit assembly complete for split type ACs 1.5 to 2 ton capacity as per existing sample etc complete all as specified and directed. | | 12 | Each |
|---|
| 49 | 45 | S&F in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 32 Amps MCB, 240 volt complete all as spacified and directed. Make: Legrand /Havells/Siemens/L&T/Crompton. | | 9 | Each |
|---|
| 50 | 46 | Supply and replacement of PCB suitable for 1.5/ 2 ton split type AC,s complete all as specified and directed. Mak: LG/Carrier/Blue Star/Voltas/Fedder Lloyd. | | 3 | Each |
|---|
| 51 | 47 | Supply and replacement of fan blade suitable for Split type AC capacity 1.5/2.0 as per sample complete all as specified and directed. | | 7 | Each |
|---|
| 52 | 48 | Supply and replacement of blower complete with fins suitable for out door unit of Split type AC capacity 1.5/2.0 as per sample complete all as specified and directed. | | 2 | Each |
|---|
| 53 | 49 | Labour only for Gas Charging of Water Cooler 60/120 and 40/80 Ltr capacity including necessary R-22/ R-134 gas, filter, anti moisturising agent, soldering /brazing ,necessary copper capillary tube any size and testing complete all as specified and directed. Note: Refrigrant gas will be paid and measured separately. | | 3 | Each Job |
|---|
| 54 | 50 | Supply and fix MCB single pole 25 Amps 240 volts, 50 Hz , 10 KA 'C' series in existing distribution board. Make: Legrand/L&T/ HPL/ Havells. | | 5 | Each |
|---|
| 55 | 51 | Supply and fix MCB single pole and neutral 32 Amps 240 volts, 50 Hz , 10 KA 'C' series in existing distribution board. Make: Legrand/ L&T/HPL/Havells | | 7 | Each |
|---|
| 56 | 52 | Supply & Replacement of PVC pipe connection, both end screwed 18” long 15mm dia with brass nuts and neoprene washers for water cooler/ desert coolers etc complete all as specified and directed. | | 5 | Each |
|---|
| 57 | 53 | Dismantling/taking out water cooler for major repair such as repair/replacement of compressor. fan motor. tank repair etc of any makes & size,from any place, and any capacity, transported to workshop & back complete all as specified and directed. Note: Repair work and replacement of damaged parts, incl MS work, shall be measured & paid seperately. | | 4 | Each Job |
|---|
| 58 | 54 | Supply and replacement of Compressor ( Sealed unit ) suitable for 60/120 Ltr. Water Cooler. Make: Kirloskar / Blue star/ Voltas/ Carrier/ Samsung. | | 2 | Each |
|---|
| 59 | 55 | Supply and replacement of Compressor ( Sealed unit ) suitable for 40/80 Ltr. Water Cooler. Make: Kirloskar / Blue star/ Voltas/ Carrier/Samsung. | | 2 | Each |
|---|
| 60 | 56 | S&F in replacement of Copper Pancake Coil Nitrile Foam Insulation Tube, Class 1, Inner Diameter - 1/2 Inch (12.7mm) & Wall Thickness - 19 mm, Pack of 1 Pcs for suction and discharge line copper tubing for split type AC 1.5/2 ton capacity complete all as specified and directed. | | 15 | Pieces |
|---|
| 61 | 57 | S & F in replacement filter as per sample for split/window type AC complete all as specified and directed. | | 6 | Each |
|---|
| 62 | 58 | S&F in replacement of Copper Tubing of suitable size1/2\"and 3/4\" for suction and discharge line two run for split type AC with insultion to protect the heat etc complete all as specified and directed. | | 31 | RM |
|---|
| 63 | 59 | Supply & fix distribution board for triple/four pole MCCB 12 way double door 415 volt with suitable capacity bus bar with natural link complete all as specified and directed. | | 1 | Each |
|---|
| 64 | 60 | S&F in replacement of cooling coil for out door unit of split type AC suitable for 1.5/2 ton etc complete all as specified and directed. | | 1 | Each |
|---|
| 65 | 61 | S&F in replacement of air cooling coil for in door unit of split type AC suitable for 1.5/2 ton etc complete all as specified and directed. | | 1 | Each |
|---|
| 66 | 62 | S&F in replacement of auto circuit plate 220V,50Hz suitable for Window Type AC complete all as specified and directed. | | 3 | Each Job |
|---|
| 67 | 63 | Supplying and fixing connection lead two single core,with PVC insulated and sheathed Copper cable size 2.5 Sqmm including earth wire complete all as directed. Make: Finolex/ Havels/ Plaza/ RR Cable/ Richa. | | 35 | RM |
|---|
| 68 | 64 | M&L for unplasticised PVC pipe of pressure rating 100 Kg/Cm2 fixed complete to walls,ceilings or in floors etc of size 15mm dia (outer dia) including chase cutting on wall & making good as per existing complete all as specified and directed. | | 30 | RM |
|---|
| 69 | 65 | M&L for two single core FRLS PVC insulated multi stranded copper conductor cable 4 Sqmm including rigid heavy duty PVC conduit size 25 mm dia in Existing surface including all accessories along with 2.5 Sq mm PVC insulated copper standard conductor earth wire connected to main wring system complete all as specified and directed. Make: Finolex/ Havels/ Plaza/ RR Cable/ Richa. | | 30 | RM |
|---|
| 70 | 66 | Supplying and fixing starting capacitor 60 to 80 MFD. Make SHARDA/KEIL suitable for water cooler SRA-300/400/200 complete all as specified and directed. Make: Sharda/Havels/ Usha/Keil. | | 5 | Each |
|---|
| 71 | 67 | Supplying and fixing running capacitor 30 MFD suitable for water cooler SRA-300/400/200 complete all as specified and directed. Make: Sharda/ Havels/ Usha/ Keil. | | 5 | Each |
|---|
| 72 | 68 | Supplying and fixing running capacitor 15 MFD suitable for water cooler SRA-300/400/200 complete all as specified and directed. Make: Sharda/ Havels/ Usha/ Keil. | | 3 | Each |
|---|
| 73 | 69 | Supply and replacement of Selector switch rotary type for two/three speed motor 16/20 amps suitable for 1.5/ 2 ton AC. | | 5 | Each |
|---|
| 74 | 70 | Supply and replacement of front grill suitable for 1.5/ 2 ton window type Ac window type AC all as per site requirement and as per sample. Make: Carrier/Air con/Usha Sriram/Blue Star/Voltas. | | 4 | Each |
|---|
| 75 | 71 | Supply and replacement of Plastic filter for window type AC 1.5/2 ton capacity complete all as specified and directed. | | 4 | Each |
|---|
| 76 | 72 | M & L for Repairs to Voltage stabilizer of 4/5 KVA capacity single phase 230 Volts of various make after disconnecting incoming and outgoing electric connection and carry out minor repair work such as repairing of internal worn out wires, repair to electronic circuit plate, low/high cutoff circuit and replacement of unserviceable parts including testing by connecting on load and adjusting low/high cutoff and timing relay complete all as specified and directed. Note: Spares required for Replacement shall be measured and paid separately as supply only in respective items. | | 15 | Each |
|---|
| 77 | 73 | Supply only Electronic circuit plate (PCB) with timer, high and low cut off suitable for 4/5 KVA stabilizer. | | 6 | Each |
|---|
| 78 | 74 | Supply only Relay 5 Amps 230 volts suitable for 4/5 KVA stabilizer. | | 2 | Each |
|---|
| 79 | 75 | Supply only Indicator lamp complete for AC 230 Volts Red or Green round shape as per requirement Make : Havels/ AE/ IMP/ Legrand. | | 4 | Each |
|---|
| 80 | 76 | Supply only Voltmeter 0 – 300 volt round/square type. Make: AE/ IMP/ Volini/ Voltas. | | 4 | Each |
|---|
| 81 | 77 | Rewinding of Main transformer with super enameled copper wire of suitable size including varnishing and heating complete suitable for 4/5 KVA. | | 2 | Each |
|---|
| 82 | 78 | Supply only Relay 30 Amps capacity suitable for 4/5 KVA stabilizer. | | 5 | Each |
|---|
| 83 | 79 | S&F display for 1.5/ 2 ton Split type AC. | | 6 | Each |
|---|
| 84 | 80 | S&F wastage water drain out PVC pipe for 1.5/ 2 ton Split type AC. | | 5 | Each |
|---|