Housing Urban and Rular Development Government Departments Closing in 0 days TDR #28392844

Supplying , Installation , Testing And Commissioning Of Fire Alarm System At Combined Office Building At Tihra , Tehsil Dharmpur District Mandi Hp

Issued by Government Departments · Tihra, Himachal Pradesh
Tender Value
11.67 Lakhs
Estimated cost
Bid Submission
12 Jul 2021
0 days left
EMD
23400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tihra → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supplying , Installation , Testing And Commissioning Of Fire Alarm System At Combined Office Building At Tihra , Tehsil Dharmpur District Mandi Hp

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 08-Jul-2021 Corrigendum Other 12-Jul-2021

BOQ

Name of Work: Supplying, Installation, Testing and Commissioning of Fire Alarm System at Combined Office Building at Tihra, Tehsil- Dharmpur District Mandi HP
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Supply Installation and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with Suitable 1 Loop module and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8\" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 / Vds/UL Certification. Make: Bosch Avenar 2000 /Notifier (NFS3030) , Siemens (Fire Finder XLS Series), Cerberus.1Each
22Supply, Installation, Testing and Commissioning of Active and networkable repeater panel/Mimick Panel with 600 character 7\" LCD display/ mimic panel etc. Shall be EN54 -Vds/UL-FM Certification. Make: Bosch / Notifier /Siemens (Fire finder), Cerberus.1Each
33Supply, Installation, Testing and Commissioning of addressable multisensordetector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Bosch FAP-425-OT/Notifier FSC851+B224BI/ Siemens Fire finder HFP11+DB-11, Cerberus.97Each
44Supply, Installation, Testing and Commissioning of addressable smoke detector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Bosch / Notifier /Siemens (Fire finder), Cerberus.2Each
55Supply, Installation, Testing and Commissioning of addessable Double ACTION manual call point & necessary fixing arrangements with key complete as required. MCP should have IP52 or better protection rating Shall be EN54 -Vds/UL-FM Certification. Make: Bosch FMC-210-DM-G-R/Notifier FSM500K/Siemens fire finder HMS/S, Cerberus.8Each
66Supply, Installation, Testing and Commissioning of Addressable Sounder with sound pressure 90 dB(A), Sounder should have IP40 or better protection rating. Shall be EN54 -Vds/UL-FM Certification. Make: Bosch / Notifier /Siemens (Fire finder), Cerberus.8Each
77Supply, Installation, Testing and Commissioning of Addressable Monitor Module with 1 input and 1 output which shall monitor normally open or normally closed contacts. Shall be EN54 -Vds/UL-FM Certification. Make: Bosch / Notifier /Siemens (Fire finder), Cerberus.6Each
88Supply, Installation, Testing and Commissioning of Addressable Control Relay Module. Relay Control module shall be used for emergency control functions including shutting down Fire dampers in AHU's, tripping of AHU's, Fresh air fans, Ventilation fans, tripping of Access control doors etc.. Shall be EN54 -Vds/UL-FM Certification. Make: Bosch / Notifier /Siemens (Fire finder), Cerberus.1Each
99Supply, Installation, Testing and commissioning of IEC 60849 Approved Glow Type EXIT/Stair /Emergency Exit Sign Board as finalized by Engineer In Charge, on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener complete the work upto the entire satisfaction of Engineer In Charge. Make: PES /HEINRICH/ OMEX/ COOPER/Agni/Falcon8Each
1010Supply and erection of PVC insulated two core FR copper conductor cable ISI marked in PVC pipe recess/surface complete in all respect Make - Finolex / Polycab /Hawells1500Per Metre
1111Supply and erection of PVC pipe 25mm dia ISI marked (Medium) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work. Make: BEC/Diplast /Polyplast1100Per Metre

AI Tender Summary

OUR REF NO 28392844
AUTHORITY Government Departments
TENDER VALUE 11.67 Lakhs
LAST DATE 12-07-2021
Authority
Authority Name Public Works Department
Work Description Supplying , Installation , Testing And Commissioning Of Fire Alarm System At Combined Office Building At Tihra , Tehsil Dharmpur District Mandi Hp
Basic Detail
Tender No PW/MED/TA/NIT/ e-notice/21-22-2292-01 dt 25.06.21
Bidding Type Tender
Location
City Tihra
State Himachal Pradesh
Key Dates
Publish Date 08 Jul 2021
Submission Date 12 Jul 2021
Open Date 12 Jul 2021
Finance
Tender Value 11.67 Lakhs
Tender Fee 500
EMD 23400
Exemption Not Available
Document List
Tendernotice_1.pdf
BOQ_73969.xls
biddocument.pdf
3F4AA9BC-3C2C-4CE8-9A9F-3C2350AC3100.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 08, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 12, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 12, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 12, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

xls

BOQ_73969.xls

pdf

biddocument.pdf

html

3F4AA9BC-3C2C-4CE8-9A9F-3C2350AC3100.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders