Providing House Hold Connection By Ministry Of Jal Shakti Har Ghar Nal Se Jal Under Lwss Maharal Dakhyora 1St Phase In Tehsil Barsar Distt . Hamirpur ( Hp ) Sh - Construction Of O Infiltration Gallery 35 Mtrs Long , Pump House , Sub Storage Tank 8000
Tender Overview
Project Description
Providing House Hold Connection By Ministry Of Jal Shakti Har Ghar Nal Se Jal Under Lwss Maharal Dakhyora 1St Phase In Tehsil Barsar Distt . Hamirpur ( Hp ) Sh - Construction Of O Infiltration Gallery 35 Mtrs Long , Pump House , Sub Storage Tank 80000 Liters Capacity , Ohsr 40000 Liters Capacity Ohsr 100000 Liters Capacity Barbed Wire Fencing Around The Storage Tanks )
BOQ
| Name of Work: - Providing house hold connection by ministry of Jal Shakti Har Ghar Nal Se Jal under LWSS Maharal Dakhyora 1st Phase in Tehsil Barsar Distt. Hamirpur (HP) (SH: - C/O infiltration gallery 35 mtrs long, Pump house, sub storage tank 80000 liters capacity, OHSR 40000 liters capacity & OHSR 100000 liters capacity & Barbed wire fencing around the storage tanks) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Excavation in foundation , trenches etc., in all kinds of soil such as pickwork, jumper work blasting work, in soft / hard rock, including chiseling wedging out of rocks clearance of bushes etc.including shoring, dewatering etc. in all leads and lifts stacking the excavated soil upto any lead and lift clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinth , sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus earth within all leads and lifts complete to the entire satisfaction as directed by the Engineer-in-charge of the site of work. | |||
| 2 | 2 | Earth work without dewatering | 232.21 | cum | |
| 3 | 3 | Earth work with dewatering | 540.52 | cum | |
| 4 | 4 | Providing and Laying cement concrete1:6:12 (1Cement :6Sand:12 graded stone aggregate 40 mm nominal size) including curing complete excluding the cost of form work in foundation and plinth in all leads and lifts. | 10.98 | cum | |
| 5 | 5 | Random rubble masonry with hard stone in foundation\nand plinth including levelling up with cement concrete\n1:6:12 (1 cement : 6 coarse sand : 12 graded stone\naggregate 20 mm nominal size) upto plinth level with cement mortar 1:6 (1 cement : 6 coarse sand) in all leads & lifts | 17.19 | cum | |
| 6 | 6 | Providing and laying damp proof course 38mm thick with cement concrete 1:2:4 (1 cement:2 sand:4\nstone aggregate 12.5mm nominal size) and curing complete. | 8.56 | sqmt | |
| 7 | 7 | Applying a coat of hot bitumen (mexphalt 80/100 or equivalent) using 1.70 kg. per square metre on\ndamp proof course after cleaning the surface with a piece of cloth lightly soaked with kerosene oil in all leads and lifts.. | 8.56 | sqmt | |
| 8 | 8 | Brick work using common burnt clay building bricks (IInd class) in in super structure above plinth level upto floor two level in cement mortar 1:6 (1cement:6 sand) in all leads and lifts.. | 13.17 | cum | |
| 9 | 9 | Providing wood work in frames of doors, windows and other frames wrought framed and fixed in position with second class deodar wood in all leads and lifts. | 0.548 | cum | |
| 10 | 10 | Providing and fixing wood paneled glazed or paneled and glazed shutters for doors, windows and clear story 40mm thick windows including bright finished black enameled iron with necessary screws with second class deodar wood 40mm thick in all leads and lifts. | 13.72 | sqmt | |
| 11 | 11 | Providing and fixing wire gauge shutters using galvanised M.S. wire gauge of I.S. gauge designation 85 G. with wire of dia 0.56 mm for doors windows and clerestorey windows including bright finished\nblack enamelled iron hinges with necessary screws 2nd class deodar wood in all leads and lifts. | 12.25 | sqmt | |
| 12 | 12 | Providing and Laying cement concrete1:3:6 (1Cement :3Sand:6 graded stone aggregate 40 mm nominal size) including curing complete excluding the cost of form work in foundation and plinth in all leads and lifts. | 33.35 | cum | |
| 13 | 13 | Providing and Laying cement concrete M30 ( Design Mix) not leaner than ) 1:1.5:3 nominal size (1Cement :1.5 Sand:3graded stone aggregate 20 mm nominal size) & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :- | |||
| 14 | 14 | Foundations,footings bases of columns and the like and mass concrete in all leads and lifts. in all leads and lifts. | 37.5 | cum | |
| 15 | 15 | Walls (any thickness but not less than 0.10 metre thickness) including attached pilasters buttersses ,plinth and string courses etc. from top of foundation upto floor two level in all leads and lifts. | 67.23 | cum | |
| 16 | 16 | Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4meters and removal of the same for insitu reinforced concrete and plain. | |||
| 17 | 17 | Vertical surfaces such as walls(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge. | 548.34 | sqmt | |
| 18 | 18 | Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors etc. above 200mm. In thickness with in all leads and lifts & to the entire satisfaction of the Engineer-in-charge | 136.28 | sqmt | |
| 19 | 19 | Beams, cantilevers, girders & lintles ,sides and soffits of beams, beams hunching, cantilevers, bressumers and lintles not exceeding 1 meter in depth in all heights from floor complete in all respects in all leads and lifts | 3.24 | sqmt | |
| 20 | 20 | Providing and Laying cement concrete M25 ( Design Mix) not leaner than ) 1:1.5:3 nominal size (1Cement :1.5 Sand:3graded stone aggregate 20 mm nominal size) & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :- | |||
| 21 | 21 | Suspended floors,roofs,landing shelves and their supports balconies beams,girders bressumers and cantilever upto floor two level including carriage of material in all leads & lifts. | 28.86 | cum | |
| 22 | 22 | Arches upto floor two level | 3.06 | cum | |
| 23 | 23 | In slopy portion | 0.53 | cum | |
| 24 | 24 | Providing tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level including carriage of material in all leads & lifts. | 11815.4 | kg | |
| 25 | 25 | 6 mm cement plaster to ceiling in cement mortar 1:3 (1Cement :3 Sand) in all leads and lifts. | 25.65 | sqmt | |
| 26 | 26 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 40 mm thick with 20 mm nominal size stone\naggregate in all leads and lifts. | 21.75 | sqmt | |
| 27 | 27 | 20 mm cement plaster in single coat of rough sides of bricks/concrete stone walls for interior plastering upto floor two level including arrises internal rounded angles chamber and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6(1cement:6sand) in all leads and lifts. | 140.15 | sqmt | |
| 28 | 28 | Providing from work of ordinary timber plankings so as to give a rough finish including centring,shuttering, strutting and propping etc. height of propping and centring below supporting floor to ceililng not exceeding 4 metres and removal of the same for insitu reinforced concrete. | |||
| 29 | 29 | Arches beyond 6 metres span. | 30.61 | sqmt | |
| 30 | 30 | Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 (1 cement : 3 sand) with in all leads and lifts & to the entire satisfaction of the Engineer-in-charge. | 547.79 | sqmt | |
| 31 | 31 | Steel work welded in built up sections,trusses & framed work, including cutting ,hoisting & fixing in position & applying a priming coat of red lead paint :- In grating, framed ,guards,bars, ladders, railing, brackets & similar works in all leads and lifts.. | 90.77 | kg | |
| 32 | 32 | Laying jointing and testting of GMS pipe following dia (medium/ light class) for scour pipe, inlet pipe , over flow pipe & distribution system including carriage of material in all leads & lifts.( Labour rates.) | |||
| 33 | 33 | 150 mm dia . | 30 | rmt | |
| 34 | 34 | 80 mm dia . | 21 | rmt | |
| 35 | 35 | Providing and fixing double flanged C.I sluice valve of following dia (with hand wheel) as per IS: 780 (including brass spindleand as per IS: 2906 Class-II complete with bolts., nuts, rubber insertion etc. ( along with tail pieces if required) following dia including all leads and lifts complete. ( Bir make) with M.S. flanges of table 5. | |||
| 36 | 36 | 150 mm dia . | 1 | Nos | |
| 37 | 37 | 80 mm dia . | 4 | Nos | |
| 38 | 38 | Constructing chamber for sluice valves with C.I surface box 100mm top diameter, 160mmbottom diameter and 180mm deep (inside with chained lid and RCC top slab1:2:4(1cement:2sand: 4 graded stone aggregate 20mm nominal size ) 100mm thick foundation concrete 1:5:10 (1cement :5sand:10 graded stone aggregate 40mm nominal size ) and insideplastering with cement mortar 1:3(1cement:3sand) finished with a floating coat of neat cementincluding curing complete with 600x600x750mm inside size with 150mm thick wall of RCC 1:2:4 ( 1cement :2sand :4 graded stone aggregate 20mm nominal size ) complete with formand reinforcment with 6mm bars at not exceeding 150mm centres both ways in all leads andlifts and to the entire satisfaction of the Engineer-in-Charge. | 4 | Nos | |
| 39 | 39 | Providing and fixing SFRC Man hole cover with frame having frame size of 560mm internal dia (Medium duty) The Weight of cover & frame should not less than 100kg including carriage ofmaterial in all leads & lifts. | 3 | Nos | |
| 40 | 40 | Boulder filling behind the long wall facing toward upstream side of infilteration gallery / under floor complete in all leads and lifts | 51.69 | cum | |
| 41 | 41 | Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement:3sand:6 graded stone aggregate 20mm nominal size) including finishing of the top surface of concrete smooth in all leads and lifts. | 19.35 | sqmt | |
| 42 | 42 | Providing 40x3mm flat iron hold fast 40cm long including fixing to frame with 10mm dial meters bolts and nuts and wooden plug and embeding in cement mortar block 30x10x15cm 1:3:6(1cement:3sand:6 graded stone aggregate 20mm nominal size in all leads and lifts.. | 28 | Nos | |
| 43 | 43 | Providing and fixing M.S.fan clamp(Type-I of 16mm dial M.S. Bar bent to shape with hooked ends in RCC. Slab during laying including painting the exposed portion of loop all as per standard design complete. | 2 | Nos | |
| 44 | 44 | White washing with lime on undecorated walls surface (two coats) to give an even shade including thoroughly brooming the surface dirt dust mortar dirt and other foreign matter in all leads and lifts. | 86.84 | sqmt | |
| 45 | 45 | Applying priming coat over new wood and wood based surfaces after and including prepering the surface by thoroughly cleaning oil,grease,dirt and other foreign matter) sand papering and knotting Readymixed paint brushing wood primer pink in all leads and lifts. | 36.44 | sqmt | |
| 46 | 46 | Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surfaces(twocoats)to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered material complete in all leads and lifts. | 78.97 | sqmt | |
| 47 | 47 | Painting two coat (excluding priming coat) on new wood and wood based surface with ready mixed paint brushing to give an even shade including cleaning the surface of all dirt,dust and other foreign matter with ready mixed paint other than white in all leads and lifts. | 36.44 | sqmt | |
| 48 | 48 | Applying two coats of wood preservative on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,grease, dirt and other foreign matter,sand papering and knotting complete in all leads and lifts. | 7.23 | sqmt | |
| 49 | 49 | Providing and fixing M.S. round or square bars 16mm in wooden frames of windows etc. complete in all leads and lifts. | 123.24 | kg | |
| 50 | 50 | Providing and fixing following anodized aluminium fittings of anodized transparent and shade with necessary screw etc.complete | |||
| 51 | 51 | Sliding door bolts 250x16mm. | 5 | Nos | |
| 52 | 52 | M.S. tower bolts (Barrel type) leads and lifts. 200x10mm. | 10 | Nos | |
| 53 | 53 | M.S. tower bolts (Barrel type) leads and lifts. 150x10mm. | 52 | Nos | |
| 54 | 54 | M.S. tower bolts (Barrel type) leads and lifts. 100x10mm. | 12 | Nos | |
| 55 | 55 | M.S. handles 125mm dia | 40 | Nos | |
| 56 | 56 | M.S. handles 100mm dia | 12 | Nos | |
| 57 | 57 | Providing and fixing of 1.80 metre high fencing with 2.50 metre centre to centre M.S angle iron post 40x40x5mm thick with nine horizontal lines and two diagonals of galvanised steel bar bed wire (IS:278-1962 type-I) weighing 9.38 kg/per 100 metre (minimum) strained and fixed to posts with G.I. staples, including coal tarring of\nballies complete) cost of post, struts and straining bolts shall be paid for seperately.complete in all leads and lifts in all respects. | 1359.36 | Rmt | |
| 58 | 58 | Providing and fixing M.S angle iron post 40x40x5mm thick including cost of primer of fencing post complete in all leads and lifts in all respects. | 354 | kg | |
| 59 | 59 | Construction of RCC 1No over head tank 40000 litres with 10 metre staging height in M30 (Desigm Mix) from ground level to bottom of dome slab comprising of inlet,scour & over flow pipes as per deatails given below from G.L. to tank including bends of required degrees,valves of reqd.size conforming to relevants codes RCC Spiral 1.0 mtrs.wide stair case/MS stair case i/c GMS pipe railing as per IS specification,steel ladder 45 cms.wide of usual height as per site requirement M.S. manhole covers (Medium duty) 75xmx75cm fabricated with 3.15mm thick M.S sheet welded over M.S. angle iron frame of 40x40x6mm hinged on a frame of M.S. angle 50x50x6 properly grouted on the roof and having locking arrangement ventilator at Top done with minimum opening od 90x90cm. water level indicator including floats and measuring gauge, lightening conductor with earthing arrangement etc.The RCC over head reservoir shall include randering/plastering of the uneven expose surface, two coats of snowcem paint and any other component reqd.for the completion of the job to the entire satisfaction of Engineer-in-charge.The offers shall also include detail structural drawing / design calculations to be approved by the competent authority based on the raft foundation by taking seismic forces in the design calculation expension joints as required at site.The offer shall also i/c the cost of providing and fixing of GMS/MS pipes,and valve/fitting complete i/c duck foot bends,puddle collars,expansion joints etc.connecting with rising main & distribution main with reqd. length from the edge of foundation and any other components required for the completion of job upto the entire satsfactionof the Engineer-in-Charge. | 40000 | Liter | |
| 60 | 60 | Construction of RCC 1No over head tank 100000 litres with 10 metre staging height in M30 (Desigm Mix) from ground level to bottom of dome slab comprising of inlet,scour & over flow pipes as per deatails given below from G.L. to tank including bends of required degrees,valves of reqd.size conforming to relevants codes RCC Spiral 1.0 mtrs.wide stair case/MS stair case i/c GMS pipe railing as per IS specification,steel ladder 45 cms.wide of usual height as per site requirement M.S. manhole covers (Medium duty) 75xmx75cm fabricated with 3.15mm thick M.S sheet welded over M.S. angle iron frame of 40x40x6mm hinged on a frame of M.S. angle 50x50x6 properly grouted on the roof and having locking arrangement ventilator at Top done with minimum opening od 90x90cm. water level indicator including floats and measuring gauge, lightening conductor with earthing arrangement etc.The RCC over head reservoir shall include randering/plastering of the uneven expose surface, two coats of snowcem paint and any other component reqd.for the completion of the job to the entire satisfaction of Engineer-in-charge.The offers shall also include detail structural drawing / design calculations to be approved by the competent authority based on the raft foundation by taking seismic forces in the design calculation expension joints as required at site.The offer shall also i/c the cost of providing and fixing of GMS/MS pipes,and valve/fitting complete i/c duck foot bends,puddle collars,expansion joints etc.connecting with rising main & distribution main with reqd. length from the edge of foundation and any other components required for the completion of job upto the entire satsfactionof the Engineer-in-Charge. | 100000 | Liter |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender