| 1 | 1 | BOQ UPLOADED ON 30 JUN 2021 | | | |
|---|
| 2 | 2 | SCH \"A\" PART-I(CIVIL WORKS) | | | |
|---|
| 3 | 3 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 150mm thickness (below or above ground level) and removal of unserviceable debris to outside of MD land complete all as specified and as directed. | | 5.47 | CUBIC METRE |
|---|
| 4 | 4 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc., or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in any type of soil all as specified and as directed. \n | | 89.8 | CUBIC METRE |
|---|
| 5 | 4.01 | Note:- | | | |
|---|
| 6 | 4.02 | Earthwork is deemed to be carried out by manual method. However mechanised method may be adopted without any extra cost to the government. | | | |
|---|
| 7 | 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and as directed. | | 53.8 | CUBIC METRE |
|---|
| 8 | 6 | Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. | | 36 | CUBIC METRE |
|---|
| 9 | 7 | Plain cement concrete, 1:4:8, type D2, using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed. | | 4 | CUBIC METRE |
|---|
| 10 | 8 | Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in plinth beam, footing, bases of columns etc., complete all as specified and as directed. | | 18 | CUBIC METRE |
|---|
| 11 | 8.01 | Note:- | | | |
|---|
| 12 | 8.02 | Reinforcement shall be measured and paid separately as applicable. | | | |
|---|
| 13 | 9 | Use and waste of formwork to sides of concrete foundations, plinth beams and similar work; vertical or to batter rough finished surfaces of concrete complete all as specified and as directed. | | 107 | SQUARE METRE |
|---|
| 14 | 10 | Mild steel TMT bars 10mm dia & over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in main reinforcement complete all as specified and as directed. | | 1100 | KILO GRAM |
|---|
| 15 | 11 | Mild steel TMT bars but 5mm dia and over upto and including 10mm dia, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers & binders complete all as specified and as directed. | | 382 | KILO GRAM |
|---|
| 16 | 12 | Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 5cm but not exceeding 10cm and diameter of neck 5mm to 10mm complete all as specified and as directed. | | 280 | KILO GRAM |
|---|
| 17 | 13 | Rolled mild steel as in joists, channel, angle or tee sections, fixed independently, without connecting plates etc., (cut to ordinary lengths i.e within 20mm of the length indicated) of Fe-410-W (Gde E-250 quality A) complete all as specified and as directed. | | 10158 | KILO GRAM |
|---|
| 18 | 14 | Rolled mild steel of grade Fe-410-W (Gde-E-250) Quality-A as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, riveted, bolted or welded complete all as specified and as directed. | | 660 | KILO GRAM |
|---|
| 19 | 15 | Rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces., cleats etc., of Fe-410-W (Gde E-250 quality A) complete all as specified and as directed. | | 11250 | KILO GRAM |
|---|
| 20 | 16 | Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed. | | 594 | SQUARE METRE |
|---|
| 21 | 17 | Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed. | | 57 | SQUARE METRE |
|---|
| 22 | 18 | Preparing new surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. | | 742 | SQUARE METRE |
|---|
| 23 | 19 | SCH \"A\" PART-II(ELECTRIFICATION) | | | |
|---|
| 24 | 20 | Point wiring on stone / brick masonry wall complete with two 4.0 sqmm single core PVC insulated 1100 volts grade unsheathed FRLSH cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 25 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 4.0 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly, including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep, concealed in walls, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with bakelite hylam sheet cover 3mm thick fixed with cadmium plated screws for housing the switches, socket outlets, fan regulators etc., for one 3 pin switch socket outlet, 15 Amps, on independent board complete all as specified and as directed. | | 12 | POINT |
|---|
| 25 | 21 | Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps and 15 Amps universal type complete all as specified and as directed. | | 12 | EACH |
|---|
| 26 | 22 | Integral industrial SMD LED highbay fitting, 120 watt, IP-65 with pressure die-cast aluminium housing with integrated polycarbonate cover, with all accessories and integrated electronic driver suitable to operate on AC 220 V / 230 V, 50 Hz supply, pre wired including connecting up with suitable size cable complete all as specified and as directed. | | 12 | EACH |
|---|
| 27 | 22.01 | Note:- | | | |
|---|
| 28 | 22.02 | (a) Make shall be C & S Cat No. CORVUS-E/120W or equivalent of makes as listed here-in-after. | | | |
|---|
| 29 | 22.03 | (b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after. | | | |
|---|
| 30 | 23 | SMD LED flood light 150 watt, IP-65 with pressure die-cast aluminium housing luminaire in single piece deep drawn housing with all accessories and glass cover with suitable bracket or with grouted spring pressure fastener / steel rawl plugs pre wired including connecting up with FRLSH PVC sheathed 2.5 sqmm 2 single core copper conductor flexible wire drawn through suitable flexible conduit complete all as specified and as directed. | | 6 | EACH |
|---|
| 31 | 23.01 | Note:- | | | |
|---|
| 32 | 23.02 | (a) Make shall be C & S Cat No. ORION -1/150W or equivalent of makes as listed here-in-after. | | | |
|---|
| 33 | 23.03 | (b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after. | | | |
|---|
| 34 | 24 | Air circulators pedestal fan metal heavy duty 600mm sweep, AC single phase, 240 Volts, 50 Hz including all accessories and connecting complete all as specified and as directed. \n\n | | 6 | EACH |
|---|
| 35 | 24.01 | Note:- | | | |
|---|
| 36 | 24.02 | Make shall be of Usha Cat No. DOMINAIRE PEDESTAL FAN or equivalent of makes as listed here-in-after. | | | |
|---|
| 37 | 25 | MCB DB SPN 8 way, single door, powder coated, 240 volts, AC, 50Hz, with 200 Amps rated bus bar, neutral link, earth link and connecting up complete all as specified and as directed. | | 3 | EACH |
|---|
| 38 | 26 | MCB 6-40 Amps, SP, 240 Volts, 50 Hz, AC supply, \"B\" curve, with breaking capacity of 10 kA complete all as specified and as directed. | | 18 | EACH |
|---|
| 39 | 26.01 | Note:- | | | |
|---|
| 40 | 26.02 | (a) Make shall be Havells Cat No. DHMGBSPF006-032 or equivalent of makes as listed here-in-after. | | | |
|---|
| 41 | 27 | MCB 40 Amps, SPN, 240 Volts, 50 Hz, AC supply, \"C\" curve with breaking capacity of 10 kA complete all as specified and as directed. | | 3 | EACH |
|---|
| 42 | 27.01 | Note:- | | | |
|---|
| 43 | 27.02 | (a) Make shall be Havells Cat No. DHMGCSNF40 or equivalent of makes as listed here-in-after. | | | |
|---|
| 44 | 28 | Power / Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor, two runs of single core 4 sqmm FRLSH conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 4 sqmm PVC insulated single core multistranded copper conductor cable FRLSH (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed. | | 200 | RUNNING METRE |
|---|
| 45 | 28.01 | Note:- | | | |
|---|
| 46 | 28.02 | (a) Two runs of 6 sqmm cable and one run of 6 sqmm cable and one run of conduit will be measured as one length. | | | |
|---|
| 47 | 28.03 | (b) Cutting chases on walls for concealing pipes and cost of terminal box is deemed to be included in the item rates quoted for sub-main wiring / circuit wiring. | | | |
|---|
| 48 | 29 | Power / Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm FRLSH conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable FRLSH (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed. | | 100 | RUNNING METRE |
|---|
| 49 | 29.01 | Note:- | | | |
|---|
| 50 | 29.02 | (a) Two runs of 6 sqmm cable and one run of 6 sqmm cable and one run of conduit will be measured as one length. | | | |
|---|
| 51 | 29.03 | (b) Cutting chases on walls for concealing pipes and cost of terminal box is deemed to be included in the item rates quoted for sub-main wiring / circuit wiring. | | | |
|---|
| 52 | 30 | XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed. | | | |
|---|
| 53 | 30.01 | Note:- | | | |
|---|
| 54 | 30.02 | (a) Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately. | | | |
|---|
| 55 | 30.03 | (b) Lugs and glands shall be used appropriately wherever required while connecting cables and the quoted rates are deemed be include for the same. | | | |
|---|
| 56 | 30.04 | (b) 2 core, cross sectional area 10 sqmm. | | 80 | RUNNING METRE |
|---|
| 57 | 30.05 | (a) 4 core, cross sectional area 16 sqmm. | | 60 | RUNNING METRE |
|---|
| 58 | 31 | Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and laid in trenches / under fllor / / under roads / crossings etc., of bore of pipe 40mm for cable protection complete all as specified and as directed. | | 3 | RUNNING METRE |
|---|
| 59 | 31.01 | Note:- | | | |
|---|
| 60 | 31.02 | Earthwork as required shall be measured and paid separately. | | | |
|---|
| 61 | 32 | Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and fixed complete to walls / poles etc., of bore of pipe 40mm for cable protection complete all as specified and as directed. | | 3 | RUNNING METRE |
|---|
| 62 | 33 | Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X minimum 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed. | | 3 | EACH JOB |
|---|
| 63 | 34 | Dry river sand laid to required width of trench at bottom and top for cable cushioning all as specified and as directed. | | 8.1 | CUBIC METRE |
|---|
| 64 | 34.01 | Note:- | | | |
|---|
| 65 | 34.02 | Punned thickness only shall be measured. | | | |
|---|
| 66 | 35 | Common burnt bricks sub class \"B\" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection all as specified and as directed. | | 0.8 | THOUSAND NUMBERS |
|---|
| 67 | 36 | Earth continuity conductor or main earthing lead of 4mm dia GI wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required as in repairs complete all as specified and as directed. \n\n | | 30 | RUNNING METRE |
|---|