Military Engineer Services-MES has published Special Repair/Replacement To External Electical Services And Unserviceable/ Old Vintage Street Lights Fittings , At Pao And Anand Niketan Area And Provn Of Prepaid Automatic Meter Reading System And Billing Software For Private Parties Under The A. Submission Date for this Tender is 02-08-2021. Electrical Maintenance Tenders in GE DEOLALI Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 15-Jul-2021 | CORRIGENDUM | Other | 19-07-2021 |
2 | 15-Jul-2021 | CORRIGENDUM 01 | Other | 19-07-2021 |
3 | 19-Jul-2021 | DATE CORRIGENDUC | Date | 26-07-2021 |
4 | 26-Jul-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 02-08-2021 |
NAME OF WORK : SPECIAL REPAIR/REPLACEMENT TO EXTERNAL ELECTICAL SERVICES AND UNSERVICEABLE/ OLD VINTAGE STREET LIGHTS FITTINGS , AT PAO AND ANAND NIKETAN AREA AND PROVN OF PREPAID AUTOMATIC METER READING SYSTEM AND BILLING SOFTWARE FOR PRIVATE PARTIES UNDER THE AOR OF GE DEOLALI | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down old u/s street light fitting and S&F 70 watt new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device Suitable for pole dia Ø 54 mm (max.). Make Havells Cat Part Num:-ENDURACITYLINERNE OSL70WLED 757 PASYBOTG or or Philips Model No- BRP409 LED 060 CW HE NR PC S1 PSU GR ( Green line) or Wipro Model No-LR02-671-XXX-57-G2 ( Skyline) or Bajaj Model No- BRTFG 60W LED V3 WW (EDGE LED) | 28 | Each | |
2 | 2 | Supply and fix cable PVC insulated stranded aluminium conductor cable 1.0 sqmm flat/round three core 1100 volts grade complete all as specified and directed | 200 | RM | |
3 | 3 | M & L for bracket made out of GI tubing 40mm dia,light grade 1.5 mtr long including fixing with MS clamps -1 Nos made out of 40 mm wide 4 mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia -2 Nos with flat washer (3mm thick) -02 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete all as directed at site. | 28 | Each | |
4 | 4 | Supply, Laying , jointing and testing in replacement of LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of 2 core 10 sqmm size | 160 | RM | |
5 | 5 | All as item No above but 3.5 core 35 Sqmm | 200 | RM | |
6 | 6 | Supply,Laying , jointing and testing HT underground cable in replacement heavy duty, 11000 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes complete all as specified and directed of 120 sqmm 3 core size. | 320 | RM | |
7 | 7 | Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed. | 4 | Qtl | |
8 | 8 | Supplying, fixing, jointing and testing heat shrinkable cable end joint , out-door type with and including jointing materials suitable for 11 KV , XLPE cable of size 120 sqmm , 3 core , complete all as specified and directed . | 4 | Each | |
9 | 9 | S&F tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed of 80 mm bore | 12 | RM | |
10 | 10 | All as item No-9 above but 40 mm bore | 21 | RM | |
11 | 11 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed. | 165.281 | Cum | |
12 | 12 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. | 48.4704 | CuM | |
13 | 13 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed | 116.81 | CuM | |
14 | 14 | M&L for sand cushioning to under ground cable providing with a layer of and 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge\n(Note : punning thickness of 18 cm will be measured for payment) | 44.064 | CUM | |
15 | 15 | Supplying and laying unreinforced precast concrete HT cable cover, class HV, type 1 flat , size 300mm x 180mm x 40mm complete all as specified and directed. | 1100 | Each | |
16 | 16 | M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed. | 2.304 | per 1000 | |
17 | 17 | S & F stay assembly comprising of MS stay plate of size 30cmx30cmx6mm thick, stay rod with nuts 215cm long, 20mm dia, MS/GI stay bow 40 cm length with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm, loop insulation size 65 x 90mm clearance of hole 16 mm & other accessories all as per SSR Part-1, Plate No.1 including necessary MS clamps complete all as specified and directed.(excavation earth work ,PCC work and stay wire will be measured and paid separetaly)\n | 1 | Each | |
18 | 18 | M&L for galvanized steel wire 7/40.0m dia for stay. | 0.15 | Qtl | |
19 | 19 | M & L for cement concrete 1 :3 :6 type C-2 using 40 mm graded aggregate incl necessary form work all as specified. | 1 | CUM | |
20 | 20 | M & L for scrubbing out old paint,rust etc from 9 Mtr long pole and making smooth and even suface then painting with one coat of anti rust paint and two coats of superior quality aluminium paint on entire exposed portion of pole structure including all fitments on pole and writing pole number with 2'' size with white paint lettering on black base all as directed at site .(work shall be completed in the stipulated period as directed). | 40 | Each | |
21 | 21 | Supply, installation and testing HT gang operated air break switch in replacement 11 KV, 3 pole vertically mounted type, mechanically operated, mounted on steel frame with operating mechanism, worked from ground level for current upto 200 Amps and 9 insulators suitable for 11 KV, complete all as specified and directed. | 3 | Each | |
22 | 22 | S&F drop-out fuse unit, expulsion type for out door air break gang operated switch, single pole mounted on and including insulators and jumpers for 11kv working pressure fixed to and including MS channel with nuts, bolts and washers etc, systhetic bounded fuse tube complete with line cap suitable for current carrying capacity upto 100 Amps all as directed.(set of three) | 2 | Set of Three | |
23 | 23 | Supply & fix Thermo plastic street light sintex box of size 280 X 170 X 130 mm Cat No GS-JB-2817 top Hinged ( or equivalent make of National) wiith MCB TPN 32 Amps for looping of cable for 3 Phase and 1 neutral fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside the box. | 28 | Each | |
24 | 24 | Supply and fix , test , commissioning of LT weather proof panel board powder coated out door type double door shutter type made out of CRCA 3 mm thick outer and 1.6mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar , chamber and with aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply including provn of digital ammeter 0-500A, digital voltmeter 0-500Volts, CT's of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron & depth of panel board should not be less than 0.4m) a) Aluminium bus bar of capacity 600 Amps for Phase-R-Y-B & 300 Amps for neutral -1 No \nb) MCCB 4 Pole 36 KA 250 Amp - 1 No (I/C)\nc) MCCB 4 Pole 36 KA 160 Amp - 1 No (O/G)\nd) MCCB 4 Pole 25 KA 63 Amp - 6 Nos (O/G) | 1 | Each | |
25 | 25 | All as pr item No 24 above but with following accessories a) Aluminium bus bar of capacity 300 Amps for Phase-R-Y-B & 200 Amps for neutral -1 No \nb) MCCB 4 Pole 35 KA 160 Amp - 1 No (I/C)\nc) MCCB 4 Pole 25 KA 63 Amp - 5 No(O/G)\n | 1 | Each | |
26 | 26 | All as pr item No above but with following accessories a) Aluminium bus bar of capacity 600 Amps for Phase-R-Y-B & 300 Amps for neutral -1 No \nb) MCCB 4 Pole 50 KA 400 Amp -1 No (I/C)\nc) MCCB 4 Pole 36 KA 250 Amp -1 No(O/G) d) MCCB 4 Pole 36 KA 160 Amp -2 No(O/G) e) MCCB 4 Pole 30 KA 63 Amp -1 No(O/G)\n | 1 | Each | |
27 | 27 | M&L for earthing complete with galvanized earth electro of size 600X600X6mm thick buried directly in ground, earth pit not less than 2.25m deep below normal GL with top edge of the earth plate not less than 1.25m below GL connected with earth strip 32 x 6 by means of check nuts, bolts, nuts, washers of GI all as shown in plate no. 3 of MES sch. Pt 0I, connected to earthing test point necessary excavation, earth work, PCC, RCC cover, watering by funnel etc., all as specified and directed by Engineer-in-Charge complete including testing on completion\n | 6 | Each | |
28 | 28 | Taking down carefullyby discionneting and unscrewing from boards/outlet boxes, electric metersof any locations and size and removing materials to store for keeping in safe custody or for taking credit maintaining proper records, reading of old meters, Make,ser no, date and time of removal and submitted to AGE E/M office, Complete all as specified and directed. | 40 | Each job | |
29 | 29 | Supplying and fixing smart single phase two wire dual source prepaid energy meters BIS 15884marked in existing meter board / florr panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition \nMAKE: L&T, Secure, Schnieder | 30 | Each | |
30 | 30 | Supplying and fixing smart three phase four wire dual source prepaid energy meters BIS 15884 marked in existing meter board / florr panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 415 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense\nthe DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition.\nMAKE: L&T, Secure, Schnieder | 10 | Each | |
31 | 31 | Supply and fix Desktop Computer 8 GB RAM, 1 TB HDD, Core i3 with HD Graphics 2000 17 inch monitor screen with key board and mouse with all electric and lan connection complete all as specified and directed at site. | 1 | Each | |
32 | 32 | Supply and Fix UPS- 1 KVA, with 2 nos 7.5 AH batteries, surge protection and 15 Mins backup complete all as specified and directed at site. | 1 | Each | |
33 | 33 | Supply and fix Token printer with print speed 90mm/sec paper width 57.5 + mm width 12 V DC power supply, USB cable etc with connected accessories complete all as specified and directed at site. | 1 | Each | |
34 | 34 | Supply and Fix Report Printer - A4 Size, monochrome laser Black and white complete all as specified and directed at site. | 1 | Each | |
35 | 35 | Supply anf fix of 2 pair 2 Core telephone cable for Meter to In Home Display and 2.5 sq mm armoud copper cable from DG panel to each metering board | 80 | RM | |
36 | 36 | Vending software - Installation Charges for Web based Vending system with provision of Hardware key, One day Training of the vending System, Tariff desinging and Customer Data Base definition for one Login | 1 | Job | |
37 | 37 | Suuply and fix in repair new sheet metal enclosure for DB'S when MCBs to e used Triple pole and neutral ( TPN) 4 way double door complete all as specified and directed. | 6 | Each | |
38 | 38 | Supply and fix in repair MCB (TPN) triple pole and neutral 415 V 63 Amps complete all as specified and directed. .Make : L&TBB40060B | 6 | Each | |
39 | 39 | Supply and fix in repair sheet metal enclosure double door 8 way DBs SPN, 240V with 200 Amps rated bus bars double door complete all as specified and as directed. | 10 | Each | |
40 | 40 | Supply and fix in repair MCB SPN 40 to 63 Amps, 240 volts complete all as specified and as directed.Make : L&T BB20400B | 10 | Each | |
41 | 41 | Supply and fix in repair MCB SP 5 to 32 Amps, 240 volts complete all as specified and as directed.Make : L&T BB10320B | 90 | Each | |
42 | 42 | M & L in repair sub main wiring with 4 single core, 10 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FR cable 1100 Volts grade including 10 Sqmm PVC insulated unsheathed multi stranded copper conductor FR as continuous earth wire drawn through Casing caping and connecting to common earth terminals complete all as specified and directed. Note :- (i) Four runs of copper cable and one run of earth wire including conduit /PVC casing/caping shall be measured as one length. | 60 | RM | |
43 | 43 | M & L in repair sub main wiring with 2 single core, 6 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FR cable 1100 Volts grade including 6 Sqmm PVC insulated unsheathed multi stranded copper conductor FR as continuous earth wire drawn through Casing caping and connecting to common earth terminals complete all as specified and directed. Note :- (i) Two runs of copper cable and one run of earth wire including conduit /PVC casing/caping shall be measured as one length. | 70 | RM | |
44 | 44 | Bi-Annual charges for Vending Services (Per consumer Meter) | 2 | Each | |
45 | 45 | Note: Amount of sch of credit of Rs.26,660/-will be deducted from total amount of BOQ. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy