Special Repair/Replacement To External Electical Services And Unserviceable/ Old Vintage Street Lights Fittings , At Pao And Anand Niketan Area And Provn Of Prepaid Automatic Meter Reading System And Billing Software For Private Parties Under The A, GE DEOLALI-Maharashtra

Military Engineer Services-MES has published Special Repair/Replacement To External Electical Services And Unserviceable/ Old Vintage Street Lights Fittings , At Pao And Anand Niketan Area And Provn Of Prepaid Automatic Meter Reading System And Billing Software For Private Parties Under The A. Submission Date for this Tender is 02-08-2021. Electrical Maintenance Tenders in GE DEOLALI Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

28353186
Corrigendum : Special Repair/Replacement To External Electical Services And Unserviceable/ Old Vintage Street Lights Fittings , At Pao And Anand Niketan Area And Provn Of Prepaid Automatic Meter Reading System And Billing Software For Private Parties Under The A
Open Tender
Indian
Maharashtra
GE DEOLALI
02-08-2021

Tender Details

Special Repair/Replacement To External Electical Services And Unserviceable/ Old Vintage Street Lights Fittings , At Pao And Anand Niketan Area And Provn Of Prepaid Automatic Meter Reading System And Billing Software For Private Parties Under The A

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Jul-2021 CORRIGENDUM Other 19-07-2021
2 15-Jul-2021 CORRIGENDUM 01 Other 19-07-2021
3 19-Jul-2021 DATE CORRIGENDUC Date 26-07-2021
4 26-Jul-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 41200.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : SPECIAL REPAIR/REPLACEMENT TO EXTERNAL ELECTICAL SERVICES AND UNSERVICEABLE/ OLD VINTAGE STREET LIGHTS FITTINGS , AT PAO AND ANAND NIKETAN AREA AND PROVN OF PREPAID AUTOMATIC METER READING SYSTEM AND BILLING SOFTWARE FOR PRIVATE PARTIES UNDER THE AOR OF GE DEOLALI
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down old u/s street light fitting and S&F 70 watt new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device Suitable for pole dia Ø 54 mm (max.). Make Havells Cat Part Num:-ENDURACITYLINERNE OSL70WLED 757 PASYBOTG or or Philips Model No- BRP409 LED 060 CW HE NR PC S1 PSU GR ( Green line) or Wipro Model No-LR02-671-XXX-57-G2 ( Skyline) or Bajaj Model No- BRTFG 60W LED V3 WW (EDGE LED) 28 Each
2 2 Supply and fix cable PVC insulated stranded aluminium conductor cable 1.0 sqmm flat/round three core 1100 volts grade complete all as specified and directed 200 RM
3 3 M & L for bracket made out of GI tubing 40mm dia,light grade 1.5 mtr long including fixing with MS clamps -1 Nos made out of 40 mm wide 4 mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia -2 Nos with flat washer (3mm thick) -02 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete all as directed at site. 28 Each
4 4 Supply, Laying , jointing and testing in replacement of LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of 2 core 10 sqmm size 160 RM
5 5 All as item No above but 3.5 core 35 Sqmm 200 RM
6 6 Supply,Laying , jointing and testing HT underground cable in replacement heavy duty, 11000 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes complete all as specified and directed of 120 sqmm 3 core size. 320 RM
7 7 Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed. 4 Qtl
8 8 Supplying, fixing, jointing and testing heat shrinkable cable end joint , out-door type with and including jointing materials suitable for 11 KV , XLPE cable of size 120 sqmm , 3 core , complete all as specified and directed . 4 Each
9 9 S&F tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed of 80 mm bore 12 RM
10 10 All as item No-9 above but 40 mm bore 21 RM
11 11 Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed. 165.281 Cum
12 12 Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. 48.4704 CuM
13 13 Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed 116.81 CuM
14 14 M&L for sand cushioning to under ground cable providing with a layer of and 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge\n(Note : punning thickness of 18 cm will be measured for payment) 44.064 CUM
15 15 Supplying and laying unreinforced precast concrete HT cable cover, class HV, type 1 flat , size 300mm x 180mm x 40mm complete all as specified and directed. 1100 Each
16 16 M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed. 2.304 per 1000
17 17 S & F stay assembly comprising of MS stay plate of size 30cmx30cmx6mm thick, stay rod with nuts 215cm long, 20mm dia, MS/GI stay bow 40 cm length with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm, loop insulation size 65 x 90mm clearance of hole 16 mm & other accessories all as per SSR Part-1, Plate No.1 including necessary MS clamps complete all as specified and directed.(excavation earth work ,PCC work and stay wire will be measured and paid separetaly)\n 1 Each
18 18 M&L for galvanized steel wire 7/40.0m dia for stay. 0.15 Qtl
19 19 M & L for cement concrete 1 :3 :6 type C-2 using 40 mm graded aggregate incl necessary form work all as specified. 1 CUM
20 20 M & L for scrubbing out old paint,rust etc from 9 Mtr long pole and making smooth and even suface then painting with one coat of anti rust paint and two coats of superior quality aluminium paint on entire exposed portion of pole structure including all fitments on pole and writing pole number with 2'' size with white paint lettering on black base all as directed at site .(work shall be completed in the stipulated period as directed). 40 Each
21 21 Supply, installation and testing HT gang operated air break switch in replacement 11 KV, 3 pole vertically mounted type, mechanically operated, mounted on steel frame with operating mechanism, worked from ground level for current upto 200 Amps and 9 insulators suitable for 11 KV, complete all as specified and directed. 3 Each
22 22 S&F drop-out fuse unit, expulsion type for out door air break gang operated switch, single pole mounted on and including insulators and jumpers for 11kv working pressure fixed to and including MS channel with nuts, bolts and washers etc, systhetic bounded fuse tube complete with line cap suitable for current carrying capacity upto 100 Amps all as directed.(set of three) 2 Set of Three
23 23 Supply & fix Thermo plastic street light sintex box of size 280 X 170 X 130 mm Cat No GS-JB-2817 top Hinged ( or equivalent make of National) wiith MCB TPN 32 Amps for looping of cable for 3 Phase and 1 neutral fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside the box. 28 Each
24 24 Supply and fix , test , commissioning of LT weather proof panel board powder coated out door type double door shutter type made out of CRCA 3 mm thick outer and 1.6mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar , chamber and with aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply including provn of digital ammeter 0-500A, digital voltmeter 0-500Volts, CT's of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron & depth of panel board should not be less than 0.4m) a) Aluminium bus bar of capacity 600 Amps for Phase-R-Y-B & 300 Amps for neutral -1 No \nb) MCCB 4 Pole 36 KA 250 Amp - 1 No (I/C)\nc) MCCB 4 Pole 36 KA 160 Amp - 1 No (O/G)\nd) MCCB 4 Pole 25 KA 63 Amp - 6 Nos (O/G) 1 Each
25 25 All as pr item No 24 above but with following accessories a) Aluminium bus bar of capacity 300 Amps for Phase-R-Y-B & 200 Amps for neutral -1 No \nb) MCCB 4 Pole 35 KA 160 Amp - 1 No (I/C)\nc) MCCB 4 Pole 25 KA 63 Amp - 5 No(O/G)\n 1 Each
26 26 All as pr item No above but with following accessories a) Aluminium bus bar of capacity 600 Amps for Phase-R-Y-B & 300 Amps for neutral -1 No \nb) MCCB 4 Pole 50 KA 400 Amp -1 No (I/C)\nc) MCCB 4 Pole 36 KA 250 Amp -1 No(O/G) d) MCCB 4 Pole 36 KA 160 Amp -2 No(O/G) e) MCCB 4 Pole 30 KA 63 Amp -1 No(O/G)\n 1 Each
27 27 M&L for earthing complete with galvanized earth electro of size 600X600X6mm thick buried directly in ground, earth pit not less than 2.25m deep below normal GL with top edge of the earth plate not less than 1.25m below GL connected with earth strip 32 x 6 by means of check nuts, bolts, nuts, washers of GI all as shown in plate no. 3 of MES sch. Pt 0I, connected to earthing test point necessary excavation, earth work, PCC, RCC cover, watering by funnel etc., all as specified and directed by Engineer-in-Charge complete including testing on completion\n 6 Each
28 28 Taking down carefullyby discionneting and unscrewing from boards/outlet boxes, electric metersof any locations and size and removing materials to store for keeping in safe custody or for taking credit maintaining proper records, reading of old meters, Make,ser no, date and time of removal and submitted to AGE E/M office, Complete all as specified and directed. 40 Each job
29 29 Supplying and fixing smart single phase two wire dual source prepaid energy meters BIS 15884marked in existing meter board / florr panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition \nMAKE: L&T, Secure, Schnieder 30 Each
30 30 Supplying and fixing smart three phase four wire dual source prepaid energy meters BIS 15884 marked in existing meter board / florr panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 415 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense\nthe DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition.\nMAKE: L&T, Secure, Schnieder 10 Each
31 31 Supply and fix Desktop Computer 8 GB RAM, 1 TB HDD, Core i3 with HD Graphics 2000 17 inch monitor screen with key board and mouse with all electric and lan connection complete all as specified and directed at site. 1 Each
32 32 Supply and Fix UPS- 1 KVA, with 2 nos 7.5 AH batteries, surge protection and 15 Mins backup complete all as specified and directed at site. 1 Each
33 33 Supply and fix Token printer with print speed 90mm/sec paper width 57.5 + mm width 12 V DC power supply, USB cable etc with connected accessories complete all as specified and directed at site. 1 Each
34 34 Supply and Fix Report Printer - A4 Size, monochrome laser Black and white complete all as specified and directed at site. 1 Each
35 35 Supply anf fix of 2 pair 2 Core telephone cable for Meter to In Home Display and 2.5 sq mm armoud copper cable from DG panel to each metering board 80 RM
36 36 Vending software - Installation Charges for Web based Vending system with provision of Hardware key, One day Training of the vending System, Tariff desinging and Customer Data Base definition for one Login 1 Job
37 37 Suuply and fix in repair new sheet metal enclosure for DB'S when MCBs to e used Triple pole and neutral ( TPN) 4 way double door complete all as specified and directed. 6 Each
38 38 Supply and fix in repair MCB (TPN) triple pole and neutral 415 V 63 Amps complete all as specified and directed. .Make : L&TBB40060B 6 Each
39 39 Supply and fix in repair sheet metal enclosure double door 8 way DBs SPN, 240V with 200 Amps rated bus bars double door complete all as specified and as directed. 10 Each
40 40 Supply and fix in repair MCB SPN 40 to 63 Amps, 240 volts complete all as specified and as directed.Make : L&T BB20400B 10 Each
41 41 Supply and fix in repair MCB SP 5 to 32 Amps, 240 volts complete all as specified and as directed.Make : L&T BB10320B 90 Each
42 42 M & L in repair sub main wiring with 4 single core, 10 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FR cable 1100 Volts grade including 10 Sqmm PVC insulated unsheathed multi stranded copper conductor FR as continuous earth wire drawn through Casing caping and connecting to common earth terminals complete all as specified and directed. Note :- (i) Four runs of copper cable and one run of earth wire including conduit /PVC casing/caping shall be measured as one length. 60 RM
43 43 M & L in repair sub main wiring with 2 single core, 6 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FR cable 1100 Volts grade including 6 Sqmm PVC insulated unsheathed multi stranded copper conductor FR as continuous earth wire drawn through Casing caping and connecting to common earth terminals complete all as specified and directed. Note :- (i) Two runs of copper cable and one run of earth wire including conduit /PVC casing/caping shall be measured as one length. 70 RM
44 44 Bi-Annual charges for Vending Services (Per consumer Meter) 2 Each
45 45 Note: Amount of sch of credit of Rs.26,660/-will be deducted from total amount of BOQ.