| 1 | 1 | Taking down, strip opening, cleaning all parts and packing of ceiling fan of any make and size and greasing ball bearing with specified quality grease and re-assembling the ceiling fan as a one unit and refixing fan in original position including electric connection and testing complete all as specified. Note : Replacement of spare parts such as rewinding, painting, cable shaft, bush bearing for connection etc., to be measured and paid separately under relevant items as supply only. | | 1327 | Each |
|---|
| 2 | 2 | All as per srl No 01 here in before but of exhaust fan any make and any size complete all as specified and directed. | | 240 | Each |
|---|
| 3 | 3 | M&L for rewinding of ceiling fan of 1200 mm size complete with super enamelled insulated copper wire of suitable size/gauge and varnishing including oiling, greasing, and replacement of old unserviceable or weak capacitor of suitable capacity as per manufacturer and testing complete in MES store yard all as specified and directed.\nNote: The unserviceable retreaved copper winding wire shall be handed over to MES store and necessary RV obtained. | | 680 | Each |
|---|
| 4 | 4 | All as per item No. 4 above but for ceiling fan of 1400mm sweep. | | 54 | Each |
|---|
| 5 | 5 | M&L for rewinding of exhaust fan of upto 350mm sweep with super enamelled insulated copper wire of suitable size/gauge and varnishing including oiling, greasing, and replacement of old unsv or weak capacitor of suitable capacity as per manufacturer and testing complete in MES store yard all as specified and directed. \nNote: The unserviceable retreaved copper winding wire shall be handed over to MES store and necessary RV obtained. | | 58 | Each |
|---|
| 6 | 6 | All as per item No. 5 above here-in-after but for Exhaust fan of 380mm to 450mm sweep complete all as specified and directed. | | 26 | Each |
|---|
| 7 | 7 | M&L for rewinding of Wall/Cabin/Pedestal fans of upto 350mm sweep with super enamelled insulated copper wire of suitable size/gauge and varnishing including oiling, greasing, and replacement of old unserviceable capacitor of suitable capacity as per manufacturer and testing complete in MES store yard all as specified and directed. Opening and refixing of fan motor and refixing the same after necessary repair/rewinding to be done at MES store yard within quoted rate by the contractor all as specified and directed. \nNote: The unserviceable retreaved copper winding wire shall be handed over to MES store and necessary RV obtained.\n | | 23 | Each |
|---|
| 8 | 8 | All as per item No. 7 above here-in-after but for Wall/Cabin/Pedestal fans of 400mm to 500mm sweep complete all as specified and directed. | | 13 | Each |
|---|
| 9 | 9 | Supply only defective shaft of ceiling fans including matching work for any make as per sample. | | 104 | Each |
|---|
| 10 | 10 | Supply only defective shaft of Exhaust fans including matching work for any make as per sample. | | 30 | Each |
|---|
| 11 | 11 | Supply only M&L in replacement of gun metal bush for fans of any make, type and size all as per sample approved. | | 170 | Each |
|---|
| 12 | 12 | Supply only ball bearing No. 6200/6201/6202 for ceiling/exhaust/Wall/Cabin/ Pedestal fans of any size and makes all as directed of sample as approved. (Make:- NBC/SKF/HCH) | | 1010 | Each |
|---|
| 13 | 13 | Supply only ball bearing of Nos. 6203/6204 for exhaust/Pedestal fans. | | 84 | Each |
|---|
| 14 | 14 | M&L for cleaning and de-scaling/greasing of exhaust fan and louvers with necessary cleaning materials and including painting with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc as specified and directed upto connecting complete. \n Note:-Taking down and refixing of exhaust fan will be measured and paid separately. | | 42 | Each job |
|---|
| 15 | 15 | M & L in replacement of exhaust fan/Wall/Cabin/Pedestal fan blades heavy duty for exhaust fan of size upto 300mm sweep complete all as specified and directed. | | 20 | Set |
|---|
| 16 | 16 | All as per item No. 15 above but for Exhaust fan of size 350mm to 400mm sweep. | | 26 | Set |
|---|
| 17 | 17 | All as per item No. 15 above but for Exhaust fan of size 450mm sweep. | | 10 | Set |
|---|
| 18 | 18 | Supply & fixing in replacement ceiling fan blade set of three heavy duty suitable for 1200 mm sweep including provision of fixing of screws of suitable size complete all as specified and directed. | | 50 | Set |
|---|
| 19 | 19 | All as per item No. 18 above but for size of 1400mm sweep. | | 14 | Set |
|---|
| 20 | 20 | Supply & fixing in replacement of MS louvers suitable for exhaust fan of size upto 350mm sweep complete all as specified and directed. | | 36 | Each |
|---|
| 21 | 21 | All as per item No. 20 above but for Exhaust fan of size above 350mm and upto 450mm sweep. | | 12 | Each |
|---|
| 22 | 22 | Supply and Fixing in replacement of PVC canopy for ceiling fan 1200/1400mm sweep for existing make and model complete all as directed and as approved by Engr-in-Charge. | | 110 | Set of Two |
|---|
| 23 | 23 | Supply and fixing in replacement of rubber reel with nut, bolts, split pins etc of ceiling fan with rubber reel heavy duty for hanging fan. | | 796 | Each |
|---|
| 24 | 24 | Supply and fixing on replacement of Shakle assembly (hanging clamp set) suitable for hanging down rod of ceiling fan 1200/1400 mm sweep complete with nuts, bolts, washers and split pin complete all as specified and directed. | | 254 | Each |
|---|
| 25 | 25 | Supply and fixing in replacement of down rod with clamps etc of ceiling fan with down rod of 15mm bore medium grade GI pipe 0.30 metre long with clamps, bolts, nuts, split pins washers of suitable size of approved quality all as per specified and directed. | | 44 | Each |
|---|
| 26 | 26 | All as per item No. 25 above but of size 0.45m long. | | 44 | Each |
|---|
| 27 | 27 | Supply and fixing in replacement of connector block of ceiling fan of suitable size of approved quality. | | 880 | Each |
|---|
| 28 | 28 | Supply and fixing in replacement of capacitor suitable for ceiling fans with capacitor having capacity 2.5mfd, 240 Volts. | | 327 | Each |
|---|
| 29 | 29 | All as per srl item No 28 above but of capacity 3.15mfd. | | 148 | Each |
|---|
| 30 | 30 | All as per srl item No 28 above but of capacity 4mfd. | | 94 | Each |
|---|
| 31 | 31 | Supply and fixing PVC Round Sheathed, FR grade, Copper Conductor (flexible) industrial cable, 1100 Volts, of size 0.5 Sqmm 3 core, complete incl taking down old unsv cable and all as specified and directed. | | 510 | RM |
|---|
| 32 | 32 | All as per srl item No 31 above but of size of size 1.5 Sqmm 3 core | | 150 | RM |
|---|
| 33 | 33 | M&L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed. | | 120 | Each |
|---|
| 34 | 34 | All as per item No. 33 above but gray paint for Exhaust fan of any size and make complete all as specified and directed. | | 28 | Each |
|---|
| 35 | 35 | Taking down geyser 25/50 ltrs capacity of any make, opening up for inspection descalling by chemical treatment of internal tank, thermostat pipe, base plate assembly carrying out minor repairs including testing for water tightness and pressure and refixing in position including making electrical and water connection all as directed. | | 61 | Each |
|---|
| 36 | 36 | S & F heating element Triangle/Cup Type 1.5 KW in replacement for any make of geyser of 25 litres capacity as per site requirement and sample approved. (Make : Micron/Theetha/ Standard or ISI Marked as approved). | | 26 | Each |
|---|
| 37 | 37 | All as per srl item No 36 here-in-before but of 2.0 KW capacity (Make : Micron/Theetha/ Standard or ISI Marked as approved). | | 16 | Each |
|---|
| 38 | 38 | All as per srl item No 36 here-in-before but of 3.0 KW suitable for Instant Start Geyser of 3 Ltrs cap of any type. (Make : Micron/Theetha/ Standard or ISI Marked as approved). | | 18 | Each |
|---|
| 39 | 39 | S & F in replacement thermostat upto of size 9\" long, (25 ltrs capacity) auto cut/push button type all as specified. (Make : Micron/Theetha/ Standard or ISI Marked of approved make). | | 83 | Each |
|---|
| 40 | 40 | All as per srl item No 39 above but of size 11\" long, (50 ltrs capacity) auto cut/push button type all as specified. (Make : Micron/Theetha/ Standard or ISI Marked of approved make). | | 21 | Each |
|---|
| 41 | 41 | S & F indicating lamp round /flat type as required in replacement for geyser 25/ 50 litres capacity as per sample approved | | 98 | Each |
|---|
| 42 | 42 | S & F Non Return Valve ISI marked for geyser 25/50 litres capacity in replacement as per sample approved. | | 28 | Each |
|---|
| 43 | 43 | S & F safety plug/valve for geyser 25/50 litres capacity in replacement as per sample as per sample approved. | | 36 | Each |
|---|
| 44 | 44 | S & F 304 grade stainless steel re-inforced flexible connection pipe of size 15mm x 450 mm long complete with 2 Nos brass/CP nuts and washers etc in replacement suitable for geyser of any capacity as per sample and all as directed. (Make : SHAKTI/PRAYAG/ ISI Mark as approved) | | 56 | Each |
|---|
| 45 | 45 | S & F 304 grade stainless steel re-inforced flexible connection pipe of size 15mm x 300 mm long complete with 2 Nos brass/CP nuts and washers etc in replacement suitable for geyser of any capacity as per sample and all as directed. (Make : SHAKTI/PRAYAG/ ISI Mark as approved) | | 56 | Each |
|---|
| 46 | 46 | S & F base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket in replacement for any make of geyser of 25 litres cap as per sample. | | 16 | Each |
|---|
| 47 | 47 | S & F base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket in replacement for any make of geyser of 50 litres cap as per sample. | | 5 | Each |
|---|
| 48 | 48 | Supply and fixing in replacement 25 Ltr inner stainless steel tank suitable for 25 Ltr storage water heater complete and all as directed. | | 15 | Each |
|---|
| 49 | 49 | Supply and fixing in replacement 50 Ltr inner stainless steel tank suitable for 50 Ltr storage water heater complete and all as directed. | | 4 | Each |
|---|
| 50 | 50 | M&L for welding /brazing the inner shell made out of stainless steel /copper sheet for geyser 25/35/50 ltrs capacity of any make and make the shell water tight including testing all as Specified and Directed. Note:-Taking down, de-scaling, replacement of rubber gasket and any minor repair involved will be measured and paid separately. | | 12 | Each Job |
|---|
| 51 | 51 | S&F Rubber gasket for water heater storage type of any capacity fixed, in replacement and suitable as per the existing, complete all as specified and directed | | 38 | Each |
|---|
| 52 | 52 | S&F in replacement MS fastener bolt 8mm dia and upto 150mm long for fixing geyser/Exhaust fan with nut and washer complete. | | 86 | Each |
|---|
| 53 | 53 | M&L for replacement of outer body suitable for 25 Ltrs storage water storage heater made of MS Sheet complete with Top & Bottom Cover as per site requirement all as directed. | | 9 | Each |
|---|
| 54 | 54 | Supply and proper filling glass wool in between inner and outer tank of geyser complete all as specified and directed. | | 12 | Kgs |
|---|
| 55 | 55 | S&F PVC Round Sheathed, FR grade, Copper Conductor (flexible) industrial cable, 1100 Volts of size 2.5 Sqmm 3 core for connecting the geyser, complete incl taking down old unsv cable and all as specified and directed. | | 130 | RM |
|---|
| 56 | 56 | S & F in replacement of Metra clad Socket 240 V, 20 A, 2P + E, upto of 20Amps capacity of Ivory or blue cap colour. | | 18 | Each |
|---|
| 57 | 57 | S & F in replacement of Metra clad plug top 240 V, 20 A, 2P + E, upto of 20Amps capacity of Ivory or gray colour. | | 18 | Each |
|---|
| 58 | 58 | Supply and Fixing in replacement of MCB SP 6 to 32 Amps, 230 Volts, 50 Hz with 10 KA ,'C' series. | | 68 | Each |
|---|
| 59 | 59 | Supply and fixing in replacement of sheet metal enclosures with plug socket single pole and neutral with two pin and earth plug and with one MCB of 20 Amps (SP) complete all as specified . | | 20 | Each |
|---|
| 60 | 60 | Supply and fixing in replacement of switch piano flush button 5 Amp single pole one way 230 volts white finish for ceiling fan or exhaust fan as per site requirement and all as directed. | | 130 | Each |
|---|
| 61 | 61 | Supply and fixing in replacement of switch piano flush button 15 Amp single pole one way 230 volts white finish for hot water storage/geyser as per site requirement and all as directed. | | 33 | Each |
|---|
| 62 | 62 | Supply and fixing in replacement of switch socket combination flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/5pin 5 Amp plug top white/ivory finish for wall/cabin/pedestal fans all as specified & directed. | | 57 | Each |
|---|
| 63 | 63 | Supply and fixing in replacement of Switch socket combination 2 in 1, 3/5 pin, 5 and 15 Amp flush type multipurpose 230 volts all as specified & directed. | | 24 | Each |
|---|
| 64 | 64 | Supply and fixing in replacement of ceiling rose surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish for ceiling fan or exhaust fan connection complete as per site requirement and all as directed. | | 80 | Each |
|---|
| 65 | 65 | Supply & fixing in replacement of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd all as specified and directed. | | 152 | Each |
|---|
| 66 | 66 | M&L in replacement of submain wiring PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through existing surface, casing/caping, recessed steel/PVC conduct complete as per site requirement and all as directed. (Note:- Two runs of main cable and one run of earth cable all-together shall be considered as one length) | | 340 | RM |
|---|
| 67 | 67 | M&L in replacement submain wiring PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing existing surface, casing/caping, recessed steel/PVC conduct complete as per site requirement and all as directed. (Note:- Two runs of main cable and one run of earth cable all-together shall be considered as one length) | | 210 | RM |
|---|
| 68 | 68 | M&L in replacement submain wiring PVC insulated FRLS single core with stranded copper cable of size 10 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing existing surface, casing/caping, recessed steel/PVC conduct complete as per site requirement and all as directed. (Note:- Two runs of main cable and one run of earth cable all-together shall be considered as one length) | | 70 | RM |
|---|
| 69 | 69 | Replacement of plastic laminated sheet top cover 3mm thick of approx size 4\" x 4\" or 6\" x 4\" as per site requirement and fitted with MS galvanised screws and cup washer in repairs including cutting of sheet and shifting of all fixtures from the old switch board and connection complete, all as specified and directed by Engr-in-charge. | | 120 | Each |
|---|
| 70 | 70 | All as per item No 69 here in after but for plastic laminated sheet top cover 3mm thick of approx size 8\"x 5\". | | 70 | Each |
|---|
| 71 | 71 | All as per item No 69 here in after but for plastic laminated sheet top cover 3mm thick of approx size 11\"x 9\". (Make :- Anchor/ Hylum/Mayur). | | 60 | Each |
|---|
| 72 | 72 | Taking down hanging laminated sheet cover of any size and re-fixing the same in repairs by replacing rusted screws and cup washers etc., complete, all as directed. | | 240 | Each job |
|---|
| 73 | 73 | Supply and fixing in repairs for Circular Hylam Sheet upto 10 Cm dia of 3 mm thick including brass machine screws of suitable size as per site requirement (for using as Junction box Cover) all as directed. | | 320 | Each |
|---|
| 74 | 74 | All as per item No 73 above but for Circular Hylam Sheet of 15 Cm dia of 3 mm thick (for using at ceiling as Canopy Cover for ceiling fan) all as directed. | | 50 | Each |
|---|
| 75 | 75 | M&L for point wiring in repairs complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/MS conduit/Casing caping with replacement of unserviceable pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required colour with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly for One Fan/exhaust fan point controlled by one switch 5 Amps one way using cable 1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing complete all as per site requirement and as directed. | | 160 | Point |
|---|
| 76 | 76 | All as per item No 75 above but One 3 pin 5/6 Amps, socket outlet point, independent board, for Wall/Cabin/Pedestal fan etc with cables 1.5 sq. mm size with through existing concealed PVC/MS conduit. | | 60 | Point |
|---|
| 77 | 77 | Repairs to hanging old point wiring for ceiling fan/exhaust fan or Wall/Cabin/Pedestal fan etc on wall surface by replacing with heavy duty PVC casing caping upto 32mm or PVC conduit upto 25mm with all accessories with all accessories and including single core copper cable of suitable gauge in short lengths, MS boxes, sheet top covers, and fixed with cadmium platted steel screws, complete, all as specified and directed including testing and making full functional for that point after repair. (Note:- fitting and fixtures if replaced will be paid and measured separately). | | 120 | Each Point |
|---|
| 78 | 78 | Material & Labour for replacement of Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thickness burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl galvanised earth lead wire of 4.00mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25mm x 25mm, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion. | | 6 | Each Set |
|---|
| 79 | 79 | All as per item No.78 above but using with galvanised iron strip 25×4mm as earthing lead.\n | | 2 | Each Set |
|---|
| 80 | 80 | Supply & fixing rigid non-metallic PVC conduit, smoke free, fire retardant, and temp stable quality of size 20mm external dia including all fixing accessories such as couplers, lock nuts, saddles, pipe hooks for securing of electric wires/cables of any type and size as laid on roof/ceiling or on wall surface of ISI make as approved all as directed including taking down existing conduct. | | 140 | RM |
|---|
| 81 | 81 | All as per item No. 80 above of size 25mm external dia. | | 100 | RM |
|---|
| 82 | 82 | Supply & Fix in replacement PVC connecting pipe with two brass adaptors 450 mm long & fixing in position | | 5 | Each |
|---|
| 83 | 83 | Supply & Fix in replacement stop cock, CP ISI marked 20 mm dia & connecting up in position | | 5 | Each |
|---|
| 84 | 84 | Supply & Fix in replacement indicator lamp of existing geyser of cap 25/50 ltr complete all as specified and directed. | | 5 | Each |
|---|
| 85 | 85 | Supply & Fix GI pipe of 15 mm bore medium grade galvanised with all fittings and accessories fixed to walls and ceilings with necessary clamps for providing in let and out let connection to Geyser all as specified and directed including making hole to wall if necessary. | | 50 | RM |
|---|
| 86 | 86 | Supply & Fix gun metal gate valve of size 15mm with iron head wheel screwed both ends for iron pipe fixed in repairs with ISI mark. Make: Tata/Scud/Zoloto | | 5 | Each |
|---|
| 87 | 87 | Supply & Fix brass bib cock 15 mm size ISI mark all as specified and directed. | | 4 | Each |
|---|
| 88 | 88 | Supply & fix in repairs of exhaust fan with automatic back shutter louvers 250mm sweep, single phase 240 volts, AC, 50 HZ and connecting up complete including louvers and provision of cable 3 core of size0.75 Sqmm from ceiling rose to fan including writing of MES Number 2.0 cm height with synthetic enamel paint complete all as specified and as directed with following specification Sweep: 250mm, Power: 34W, Air Delivery: 810 CMH, RPM: 1100 Make: Bajaj Maxima DX 250mm Exhaust Fan (White) | | 5 | Each |
|---|
| 89 | 89 | Supply and fix round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. | | 28 | Each |
|---|
| 90 | 90 | NOTES :-\n1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.\n2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc., required for complete and proper execution of the work. Refer Schedule A notes for details.\n | | | |
|---|